BXC60 BOTHHAND | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
Features
/circle6Wide 4 : 1 Input Voltage Range /circle6High Power Density /circle6High Efficiency /circle6Operating Temperature Range: -40°C to +85°C /circle6Output Short Circuit Protection: Hi ccup, continuous & Auto Recovery /circle6Output Over Voltage Protection: /circle6Over Temperature Protection /circle6Fixed Switching Frequency /circle6Input/ Output Isolation 1.5 kVdc /circle6Shielded Metal Case with Insulated Baseplate /circle6Lead Free Design, RoHS Compliant /circle6Industry Standard Pinout /circle6Adjustable Output Voltage Input Specifications Input voltage range 9~36Vdc Under voltage shutdown Full Load 8Vdc (typical) Input current Vin=24Vdc and no Load 100mA (typical) Input current Vin=24Vdc and full Load 2976mA (typical) Input current Vin=24Vdc and output shorted 10mA (typical) Converter: ON Open or 3.5V<Vr<12V Remote ON/OFF Converter: OFF Short(2) or 0V<Vr<0 .7V Sourcing current of remote control pin Nominal Vin <0.2mA Idle input current (at Remote OFF state) Nominal Vin <12mA Output Specifications Output voltage 12 Vdc Output voltage accuracy Vout=11.88 ~ 12.12Vdc ±1% Maximum Load 5A Minimum Load 0A Maximum capacitive load 4700uF (maximum) Efficiency Vin=24Vdc and full load 88% (typical) Ripple / Noise 20MHz bandwidth. 80mVp-p (maximum) Temperature coefficient ±0.02%/℃ (maximum) Output short circuit protection Automatic recovery Hiccup, Continuous Output over voltage protection 15V (typical)
Applications
/circle6Distributed power system /circle6Telecommunication application /circle6Battery powered equipment /circle6Industrial application /circle6Process control equipment /circle6Transportation equipment
Ambient Temp.TA (℃) E-mail: sales@bothhandusa.com http://www.bothhandusa.com Rev:20110610A Page 2 of 4 Isolated DC-DC Converters BXC60-24S2WHS Line regulation LL to HL at full load ±0.5% (maximum) Load regulation 25% load to full load ±0.5% (maximum) Dynamic Characteristics Transient response over shoot di/dt=0.8A/µs ≤ ±5% of Vo Transient response settling time 50% load step change 180µs (typical) Start-up time Nominal Vin and full load 60msec (typical) Switching frequency 300kHz (typical). General Specifications Reliability, calculated MTBF ≧8.88×105 hours Operating ambient temperature With derating -40℃~+85℃ Maximum case surface temperature 100℃ Storage temperature range -55℃~+125 ℃ Relative humidity 95% RH (maximum) Isolation voltage Input to output 1500Vdc Isolation capacitance Input to output 1200pF (typical) Isolation resistance Input to output (500Vdc) 109Ω (minimum) Cooling Free air convection Physical Specifications Case material Nickel-coated copper Base material FR4 PCB Potting material Silicon rubber (UL94V-0) 2.00 × 2.00 × 0.50 Inch Dimensions Weight 103g (3.63oz) (typical) Soldering temperature Lead-free wave soldering 260 ℃/10Sec (maximum) Absolute Maximum Ratings Input surge voltage 100msec. 50Vdc Performance Curves Pow er Derating Curve (Without Heatsink) Power Derating Curve (With Heatsink) Ambient Temp.TA (℃℃ ℃℃) Output Power (%) 100 120 -40 -20 0 20 40 60 80 100 120 44 0 100 120 -40 -20 0 20 40 60 80 100 12033
E-mail: sales@bothhandusa.com http://www.bothhandusa.com Rev:20110610A Page 3 of 4 Isolated DC-DC Converters BXC60-24S2WHS Input voltage vs. Efficiency Output Current vs. Efficiency Input voltage (V) Output Current (A) Note . Typical value, tested at nominal input and full load. 2. Short to -Vin (Pin 2). Mechanical Dimensions Pin Assignment Pin Single 1 +Vin 2 -Vin
3 Remote On/Off
8 Trim
9 12 15 18 21 24 27 30 33 36 Efficiency % 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Efficiency % Unit: mm [inch] Tolerance:±0.5[±0.02]
E-mail: sales@bothhandusa.com http://www.bothhandusa.com Rev:20110610A Page 4 of 4 Isolated DC-DC Converters BXC60-24S2WHS Heat-sink Material: Aluminum Weight: 19g (0.67oz) (without converter)