Business-Critical Continuity BXB100 Series Single output Special Features

  • Industry standard footprint
  • High power density (36.5 W/in3)
  • MTBF >1.4 million hours (Bellcore 332)
  • Input voltage to ETS300-132-2
  • Adjustable output voltage
  • No minimum load required
  • Separate case ground pin
  • Undervoltage lockout (UVLO)
  • UL, VDE and CSA safety approvals
  • 2 year warranty Total Power: 66 - 100 W Input Voltage: 18 - 36 V 36 - 75 V # of Outputs: Single Safety VDE0805/EN60950/IEC950 UL1950 CSA C22.2 No. 950 Rev.10.16.08_121 BXB100 Series 1 of 3 Output Voltage adjustability: 60% to 110% Setpoint accuracy: ±1.0% Line regulation: Low line to high line ±0.05% Load regulation: Full load to min. load ±0.10% Minimum load: 0 % Overshoot: At turn on and turn-off None Undershoot: None Ripple and noise:

5 Hz - 20 MHz (see note 1)

3.3 V and 5 V 75 mV pk-pk,

12V and 15 V 100 mV pk-pk, 30 mV rms Electrical Specifications Input Input voltage range: 24 Vin nominal 18 - 36 Vdc

48 Vin nominal 36 - 75 Vdc

Input current: No load 100 mA max. Remote OFF 20 mA max. Input current (max.): (See note 4) 48 V models 4 A max. @ lo max. and Vin = 0 to 75 V Input reflected ripple: (See note 6) 5 mA pk-pk Active low remote ON/OFF: Logic compatiblity: ON: OFF: (See note 7) Open collector ref to -input 1.2 Vdc max. Open circuit Undervoltage lockout: 24 Vin: power-up 17 V

24 Vin: power-down 16 V

48 Vin: power-up 34 V

48 Vin: power-down 32.5 V Start-up time: (see note 8) Power up 20 ms Remote ON/OFF 20 ms

Rev.10.16.08_121 BXB100 Series 2 of 3 Embedded Power for Business-Critical Continuity 313 process yellow 3405 1797 1375 116 2607 652 242 2985 375 240 Output Continued Ripple and noise: 12V and 15 V 100 mV pk-pk, 30 mV rms Temperature coefficient: ±0.01% / ºC Transient response: (see note 2) ±2.0% max. deviation 170 µs recovery to within ±1.0% Remote Sense: 0.5 Vds transmission line drop compensation Thermal performance: Operating case temp. -40 ºC to +100 ºC Non-operating -55 ºC to +125 ºC Altitude: Operating 10,000 feet max. Non-operating 40,000 feet max. Vibration: 5 - 500 Hz 2.4 G rms (approx.) Environmental Specifications General Specifications Efficiency: See table Isolation voltage: Input/case 1500 Vdc Input/output 1500 Vdc Output/case 1500 Vdc Switching frequency: Fixed 500 kHz typ. Approvals and standards: (see note 5) VDE0805, EN60950, IEC950 UL1950, CSA C22.2 No. 950 Case material: Aluminum baseplate with plastic case Material flammability: UL94V-0 Weight: 110 g (3.88 oz) MTBF: Bellcore 332 1,400,000 hours MIL-HDBK-217F 580,000 hours min. @ 40 °C, 100% load EMC Charateristics Conducted emissions: (see note 3) EN55022 (See note 3) Level A FCC part 15 Level A EN55022, CISPR22 Level A Protection Short-circuit: Continuous, automatic recovery Overvoltage: Non-latching Undervoltage: Non-latching Thermal: 110 °C baseplate, automatic recovery Telecom Specifications Central office interface A: ETS300-132-2

Business-Critical Continuity Rev.10.16.08_121 BXB100 Series 3 of 3 ALL DIMENSIONS IN INCHES (mm) Tolerance : x.xx 0.02in. (0.51mm) x.xxx 0.010in. (0.254mm) VIEW SHOWN PIN SIDE UP 1.90 4 x M3 x 0.5 Through 2.28 (57.91) Max. 0.700 (17.77) 1.000 (25.40) 1.400 (35.56) 2.000 (50.80) 0.400 (10.16) 0.400 (10.16) 1.000 (25.40) 1.400 (35.56) Vo(+) +SEN TRIM -SEN Vo (-) VI(+) ON/OFF CASE VI (-) 0.200 (5.08) Min. Length for all Input and Output Pins 0.500 (12.70) 2.40 (60.96) Max. External Output Trimming Output can be externally trimmed by using the method shown. 10K TRIMPOT TRIM UP TRIM DOWN RT1 OR RT2

Ordering Information

(Max.) Input Voltage OVP Output Voltage Output Current (Min.) Output Current (Max.) Efficiency (Typ.) Regulation Model Number Line Load 100 W 18 - 36 Vdc 14.5 Vdc 12 V 0 A 8.33 A 85% ±0.05% ±0.1% BXB100-24S12FLTJ 100 W 36 - 75 Vdc 6.5 Vdc 5 V 0 A 20 A 83% ±0.05% ±0.1% BXB100-48S05FLTJ 100 W 36 - 75 Vdc 14.5 Vdc 12 V 0 A 8.33 A 86% ±0.05% ±0.1% BXB100-48S12FLTJ Pin Connections Pin Number Function 1 +Vin

2 Remote ON/OFF

3 Case

7 Trim

1 Measured with 10 µF tantalum capacitor and 1 µF ceramic capacitor

across output. 2 di/dt = 0.1 A/1 µs, Vin = 48 Vdc, Tc = 25 °C, load change = 0.5 lo max. to 3 Units should be characterised within systems. External components required.

4 Input fusing is recommended based on surge current and maximum

input current.

5 This product is only for inclusion by professional installers within other

equipment and must not be operated as a stand alone product. 6 Simulated source impedance of 12 µH. 12 µH inductor in series with +Vin.

7 Active high remote on/off option is available (standard product is active

low), designate with the suffix ‘FHT’ e.g. BXB100-48S05FHTJ. Consult factory for further details and options. 8 Start-up into resistive load. 9 “J” suffix designation for RoHS 6/6. Americas

5810 Van Allen Way

Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 Europe (UK) Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 Asia (HK) 14/F, Lu Plaza

2 Wing Yip Street

Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888 For global contact, visit: www.powerconversion.com techsupport.embeddedpower @emerson.com While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. EmersonNetworkPower.com Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2008 Emerson Electric Co.