MODEL: BX-16G BX-16G SPECIFICATIONS ES-3832 Rev.2 Page 1/4 http://www.m-system.co.jp/ STANDARD RACK MOUNTING FRAME Functions & Features

  • Standard Rack Mounting Frame for mounting individual housing-stored Space-saving Rack-mounted Signal Conditioners (M-RACK, H-RACK, W-RACK, B-RACK, A-RACK)
  • Convenient for power supply wiring in instrumentation panels
  • Can be inserted into JIS and EIA standard racks
  • Also available with power distributor
  • Power distributor has an alarm fuse in each loop
  • Capable of alarm contact output for blown fuses MODEL: BX–16G–[1]

ORDERING INFORMATION

  • Code number: BX-16G-[1] Specify a code from below for [1]. (e.g. BS-16G-B) [1] Power distributor 1: Without 2: With (single-pole fuse) B: With (double-pole fuse) GENERAL SPECIFICATIONS Construction: Rack-mounted Capacity: 16 positions (H-RACK, B-RACK) 8 positions (M-RACK, W-RACK, A-RACK) Terminal screw material: Nickel-plated iron, torque: 0.8 N·m (with power distributor) Material: SPCC Coating: Melamine baked coating Isolation: Power to alarm (when power distributor is attached) Power distributor circuit: with alarm fuse for each single loop Alarm: dry contact output at blown fuse Fuse rating: 0.5 A INSTALLATION ■ Power distributor Power input: Operational voltage range 24 V DC ± 10% Operating temperature: -5 to +55°C (23 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Rack mounting Weight: Mounting frame approx. 800 g (1.8 lb), mounting frame + with power distributor approx. 2 kg (4.4 lb) PERFORMANCE Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength:

1500 V AC @1 minute (power supply or alarm terminal to

ground)

500 V AC @1 minute (power supply to alarm terminal)

(BX-16G-2, B only)

MODEL: BX-16G BX-16G SPECIFICATIONS ES-3832 Rev.2 Page 2/4 http://www.m-system.co.jp/ CONNECTION DIAGRAM ■ WITH POWER DISTRIBUTOR Single-pole fuse 1 2 + − + − + − + −+ −+ − 1 2 16 24V DC OUTPUT 24V DC OUTPUT 24V DC OUTPUT POWER 24V DC POWER 24V DC BLOWN FUSE ALARM ■ WITH POWER DISTRIBUTOR Double-pole fuse + − + − + − + −+ − + − 1 2 16 24V DC OUTPUT 24V DC OUTPUT 24V DC OUTPUT POWER 24V DC POWER 24V DC BLOWN FUSE ALARM EXTERNAL DIMENSIONS unit: mm (inch) ■ WITHOUT POWER DISTRIBUTOR A 465 (18.31) 16.3 (.64) 99 (3.90) 50 (1.97) 2.3 (.91) (1.69) 480 (18.90) 431 (16.97)

MODEL: BX-16G BX-16G SPECIFICATIONS ES-3832 Rev.2 Page 3/4 http://www.m-system.co.jp/ ■ WITH POWER DISTRIBUTOR Single-pole fuse A 465 (18.31) 16.3 (.64) 149 (5.87) 101.6 (4) 2.3 (.91) (1.69) 480 (18.90) 431 (16.97) ALARM POWER + − POWER + − COVER ■ WITH POWER DISTRIBUTOR Double-pole fuse A 465 (18.31) 16.3 (.64) 149 (5.87) 101.6 (4) 2.3 (.91) 43 (1.69) 480 (18.90) 431 (16.97) ALARM POWER + − + − COVER SERIES DIMENSIONS A *1. Dimensions in parentheses are for 7SN, 7LM, 7LMS *2. Dimensions in parentheses are for VMS, VFX, JX Series 139 (5.47) [163 (6.42)] M-RACK H-RACK B-RACK W-RACK A-RACK

MODEL: BX-16G BX-16G SPECIFICATIONS ES-3832 Rev.2 Page 4/4 http://www.m-system.co.jp/ MOUNTING REQUIREMENTS unit: mm (inch) ■ WITHOUT POWER DISTRIBUTOR 450 (17.72) 4−M5 465 (18.31) 50 (1.97) (JIS) Mounting Angle Note: Leave an appropriate amount of space below for wiring. 57.2 (2.25) (EIA) 15 (.59) ■ WITH POWER DISTRIBUTOR 101.6 (4) [100 (3.94)] * 450 (17.72) 465 (18.31) 4−M5 Mounting Angle Note: Leave an appropriate amount of space below for wiring. *Numbers in parentheses are JIS standards Specifications are subject to change without notice.