With extended temperature range BI10-EG30-Y1X/S100 7M Edition • 2019-02-08T07:50:53+01:00 1 / 4 TURCK Inc. ñ 3000 Campus Drive Minneapolis, MN 55441-2656 ñ Phone: 763-553-7300 ñ Application Support: 1-800-544-7769 ñ Fax 763-553-0708 ñ www.turck.com Type designation BI10-EG30-Y1X/S100 7M Ident-No. 4012005 Rated switching distance Sn 10 mm Mounting conditions Flush Secured operating distance ð (0,81 x Sn) mm Correction factors St37 = 1; Al = 0.3; stainless steel = 0.7; Ms = 0.4 Repeat accuracy ð 2 % of full scale Temperature drift ð ± 10 % ð ± 20 %, ï +70 °C Hysteresis 1…10 % Ambient temperature -25…+100 °C For explosion hazardous areas see instruction leaflet Output function 2-wire, NAMUR Switching frequency 0.5 kHz Voltage Nom. 8.2 VDC Non-actuated current consumption ï 2.1 mA Actuated current consumption ð 1.2 mA Approval acc. to KEMA 02 ATEX 1090X Design Threaded barrel,M30 × 1.5 Dimensions 44 mm Housing material Stainless steel, V2A (1.4301) Active area material Plastic, PA12-GF30 End cap Plastic, EPTR Max. tightening torque housing nut 75 Nm Electrical connection Cables Cable quality 5.2mm, LifYY-T105, PVC, 7 Cable cross section 2 x 0.5 mm Vibration resistance 55 Hz (1 mm) Shock resistance 30 g (11 ms) Protection class IP67 MTTF 6198 years acc. to SN 29500 (Ed. 99) 40 °C Packaging unit 1 Switching state LED, Yellow ■ ATEX category II 1 G, Ex-zone 0 for tem- peratures up to +80 °C ■ ATEX category II 2 G. Ex-zone 1 ■ ATEX category II 1 D, Ex-zone 20 for temperatures up to +70 °C ■ SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 ■ SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1 with re- dundant configuration HTF1 ■ Threaded barrel, M30 x 1.5 ■ Stainless steel, 1.4301 ■ Temperatures up to +100 °C ■ DC 2-wire, nom. 8.2 VDC ■ Output acc. to DIN EN 60947-5-6 (NA- MUR) ■ Cable connection Wiring Diagram Functional principle Inductive sensors detect metal objects con- tactless and wear-free. For this purpose they use a high-frequency electromagnetic AC field that interacts with the target. The sensors hosting a ferrite core coil generate the AC field through an LC resonant circuit. Special versions are available for ambient temperatures between -60°C and +250°C.
With extended temperature range BI10-EG30-Y1X/S100 7M Edition • 2019-02-08T07:50:53+01:00 2 / 4 TURCK Inc. ñ 3000 Campus Drive Minneapolis, MN 55441-2656 ñ Phone: 763-553-7300 ñ Application Support: 1-800-544-7769 ñ Fax 763-553-0708 ñ www.turck.com Distance D 2 x B Distance W 3 x Sn Distance T 3 x B Distance S 1.5 x B Distance G 6 x Sn Diameter active area B Ø 30 mm
With extended temperature range BI10-EG30-Y1X/S100 7M Edition • 2019-02-08T07:50:53+01:00 3 / 4 TURCK Inc. ñ 3000 Campus Drive Minneapolis, MN 55441-2656 ñ Phone: 763-553-7300 ñ Application Support: 1-800-544-7769 ñ Fax 763-553-0708 ñ www.turck.com Accessories Type code Ident-No. Description QM-30 6945103 Quick-mount bracket with dead-stop; material: Chrome-plat- ed brass Male thread M36 x 1.5. Note: The switching dis- tance of proximity switches can be reduced by the use of quick-mount brackets. BST-30B 6947216 Fixing clamp for threaded barrel devices, with dead-stop; ma- terial: PA6 MW-30 6945005 Mounting bracket for threaded barrel devices; material: Stain- less steel A2 1.4301 (AISI 304) BSS-30 6901319 Mounting bracket for smooth and threaded barrel devices; material: Polypropylene IMX12-DI01-2S-2T-0/ 24VDC 7580020 Isolating switching amplifier, 2-channel; SIL2 acc. to IEC 61508; Ex-proof version; 2 transistor outputs; input Namur signal; ON/OFF switchable monitoring of wire-break and short-circuit; toggle between NO/NC mode; signal doubling; removable screw terminals; 12.5 mm wide; 24 VDC power supply
With extended temperature range BI10-EG30-Y1X/S100 7M Edition • 2019-02-08T07:50:53+01:00 4 / 4 TURCK Inc. ñ 3000 Campus Drive Minneapolis, MN 55441-2656 ñ Phone: 763-553-7300 ñ Application Support: 1-800-544-7769 ñ Fax 763-553-0708 ñ www.turck.com Operating manual Intended use This device fulfills the directive 2014/34/EC and is suited for use in explosion hazardous areas according to EN 60079-0:2012 + A11 and EN 60079-11:2012. Further it is suited for use in safety-related systems, including SIL2 as per IEC 61508. In order to ensure correct operation to the intended purpose it is required to observe the national regulations and directives. For use in explosion hazardous areas conform to classification II 1 G and II 1 D (Group II, Category 1 G, electrical equipment for gaseous atmospheres and category 1 D, electrical equipment for dust atmo- spheres). Marking (see device or technical data sheet) É II 1 G and Ex ia IIC T6 Ga acc. to EN60079-0 and -26 and É II 1 D Ex ia IIIC T115°C Da acc. to EN60079-0 Local admissible ambient temperature ATEX category II 2 G electrical equipment -25…+100 °C, category II 1 G -25…+70 °C and category II 1 D -25…+70 °C. The corresponding tem- perature classes are provided in the ATEX type-examination certificate. Installation/Commissioning These devices may only be installed, connected and operated by trained and qualified staff. Qualified staff must have knowledge of protection classes, directives and regulations concerning electrical equipment designed for use in explosion hazardous areas. Please verify that the classification and the marking on the device comply with the actual application conditions. This device is only suited for connection to approved Exi circuits according to EN 60079-0 and EN 60079-11. Please observe the maximum ad- missible electrical values. After connection to other circuits the sensor may no longer be used in Exi installations. When interconnected to (associated) electrical equip- ment, it is required to perform the "Proof of intrinsic safety" (EN60079-14). Attention! When used in safety systems, all content of the security manual must be observed. Installation and mounting instructions Avoid static charging of cables and plastic devices. Please only clean the device with a damp cloth. Do not install the device in a dust flow and avoid build-up of dust deposits on the device. If the devices and the cable could be subject to mechanical damage, they must be protected accordingly. They must also be shielded against strong electro-magnetic fields. The pin configuration and the electrical specifications can be taken from the device marking or the technical data sheet. Service/Maintenance Repairs are not possible. The approval expires if the device is repaired or modified by a person other than the manufacturer. The most important data from the approval are listed.