BSM100GB120DN2 EUPEC | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 11
Technical content
1 Oct-21-1997
- Half-bridge
- Including fast free-wheeling diodes
- Package with insulated metal base plate Type BSM 100 GB 120 DN2 1200V 150A HALF-BRIDGE 2 C67076-A2107-A70 Maximum Ratings Parameter Symbol Values Unit Collector-emitter voltage VCE 1200 V Collector-gate voltage R GE = 20 kΩ VCGR 1200 Gate-emitter voltage VGE ± 20 DC collector current TC = 25 °C TC = 80 °C IC 100 150 A Pulsed collector current, tp = 1 ms TC = 25 °C TC = 80 °C ICpuls 200 300 Power dissipation per IGBT TC = 25 °C Ptot 800 W Chip temperature Tj + 150 °C Storage temperature Tstg -40 ... + 125 Thermal resistance, chip case R thJC ≤ 0.16 K/W Diode thermal resistance, chip case R thJCD ≤ 0.3 Insulation test voltage, t = 1min. Vis 2500 Vac Creepage distance - 20 mm Clearance - 11 DIN humidity category, DIN 40 040 - F sec IEC climatic category, DIN IEC 68-1 - 40 / 125 / 56
2 Oct-21-1997
Electrical Characteristics, at Tj = 25 °C, unless otherwise specified Parameter Symbol Values Unit min. typ. max. Static Characteristics Gate threshold voltage VGE = VCE, IC = 4 mA VGE(th) 4.5 5.5 6.5 V Collector-emitter saturation voltage VGE = 15 V, IC = 100 A, Tj = 25 °C VGE = 15 V, IC = 100 A, Tj = 125 °C VCE(sat) 3.1 2.5 3.7 Zero gate voltage collector current VCE = 1200 V, VGE = 0 V, Tj = 25 °C VCE = 1200 V, VGE = 0 V, Tj = 125 °C ICES 1.5 mA Gate-emitter leakage current VGE = 20 V, VCE = 0 V IGES - - 200 nA AC Characteristics Transconductance VCE = 20 V, IC = 100 A gfs 54 - - S Input capacitance VCE = 25 V, VGE = 0 V, f = 1 MHz C iss - 6.5 - nF Output capacitance VCE = 25 V, VGE = 0 V, f = 1 MHz C oss - 1 - Reverse transfer capacitance VCE = 25 V, VGE = 0 V, f = 1 MHz C rss - 0.5 -
3 Oct-21-1997
Electrical Characteristics, at Tj = 25 °C, unless otherwise specified Parameter Symbol Values Unit min. typ. max. Switching Characteristics, Inductive Load at Tj = 125 °C Turn-on delay time VCC = 600 V, VGE = 15 V, IC = 100 A R Gon = 6.8 Ω td(on) - 130 260 ns Rise time VCC = 600 V, VGE = 15 V, IC = 100 A R Gon = 6.8 Ω tr - 80 160 Turn-off delay time VCC = 600 V, VGE = -15 V, IC = 100 A R Goff = 6.8 Ω td(off) - 400 600 Fall time VCC = 600 V, VGE = -15 V, IC = 100 A R Goff = 6.8 Ω tf - 70 100 Free-Wheel Diode Diode forward voltage IF = 100 A, VGE = 0 V, Tj = 25 °C IF = 100 A, VGE = 0 V, Tj = 125 °C VF 1.8 2.3 2.8 V Reverse recovery time IF = 100 A, VR = -600 V, VGE = 0 V diF/dt = -1000 A/µs, Tj = 25 °C trr - 0.3 - µs Reverse recovery charge IF = 100 A, VR = -600 V, VGE = 0 V diF/dt = -1000 A/µs Tj = 25 °C Tj = 125 °C Q rr µC
4 Oct-21-1997
Ptot = ƒ(TC) parameter: Tj ≤ 150 °C 0 20 40 60 80 100 120 °C 160 TC 100 200 300 400 500 600 700 W 900 Ptot Safe operating area IC = ƒ(VCE) parameter: D = 0, TC = 25°C , Tj ≤ 150 °C -1 10 0 10 1 10 2 10 3 10 A IC 10 0 10 1 10 2 10 3 V VCE DC 10 ms 1 ms 100 µs tp = 14.0µs Collector current IC = ƒ(TC) parameter: VGE ≥ 15 V , Tj ≤ 150 °C 0 20 40 60 80 100 120 °C 160 TC 100 120 A 160 IC Transient thermal impedance IGBT Zth JC = ƒ(tp) parameter: D = tp / T -4 10 -3 10 -2 10 -1 10 0 10 K/W ZthJC 10 -5 10 -4 10 -3 10 -2 10 -1 10 0 s tp single pulse 0.01 0.02 0.05 0.10 0.20 D = 0.50
5 Oct-21-1997
Typ. output characteristics IC = f (VCE ) parameter: tp = 80 µs, Tj = 25 °C 0 1 2 3 V 5 VCE 100 120 140 160 A 200 IC 17V 15V 13V 11V Typ. output characteristics IC = f (VCE ) parameter: tp = 80 µs, Tj = 125 °C 0 1 2 3 V 5 VCE 100 120 140 160 A 200 IC 17V 15V 13V 11V Typ. transfer characteristics IC = f (VGE ) parameter: tp = 80 µs, VCE = 20 V 0 2 4 6 8 10 V 14 VGE 100 120 140 160 A 200 IC
6 Oct-21-1997
Typ. gate charge VGE = ƒ(QGate) parameter: IC puls = 100 A 0 100 200 300 400 500 nC 650 QGate V VGE
800 V600 V
Typ. capacitances C = f (VCE ) parameter: VGE = 0 V, f = 1 MHz 0 5 10 15 20 25 30 V 40 VCE -1 10 0 10 1 10 2 10 nF C Ciss Coss Crss Reverse biased safe operating area ICpuls = f(VCE ) , Tj = 150°C parameter: VGE = 15 V 0 200 400 600 800 1000 1200 V 1600 VCE 0.0 0.5 1.0 1.5 2.5 ICpuls/IC Short circuit safe operating area ICsc = f(VCE ) , Tj = 150°C parameter: VGE = ± 15 V, tSC ≤ 10 µs, L < 25 nH 0 200 400 600 800 1000 1200 V 1600 VCE ICsc/IC
7 Oct-21-1997
Typ. switching time I = f (IC ) , inductive load , Tj = 125°C par.: VCE = 600 V, VGE = ± 15 V, RG = 6.8 Ω 0 50 100 150 A 250 IC 1 10 2 10 3 10 ns t tdon tr tdoff tf Typ. switching time t = f (RG ) , inductive load , Tj = 125°C par.: VCE = 600 V, VGE = ± 15 V, IC = 100 A 0 10 20 30 40 Ω 60 R G 1 10 2 10 3 10 4 10 ns t tdon tr tdoff tf Typ. switching losses E = f (IC ) , inductive load , Tj = 125°C par.: VCE = 600 V, VGE = ± 15 V, RG = 6.8 Ω 0 50 100 150 A 250 IC mWs E Eon Eoff Typ. switching losses E = f (RG ) , inductive load , Tj = 125°C par.: VCE = 600V, VGE = ± 15 V, IC = 100 A 0 10 20 30 40 Ω 60 R G mWs E Eon Eoff
8 Oct-21-1997
Forward characteristics of fast recovery reverse diode IF = f(VF) parameter: Tj VF 100 120 140 160 A 200 IF Tj=25°C=125°CjT Transient thermal impedance Diode Zth JC = ƒ(tp) parameter: D = tp / T -4 10 -3 10 -2 10 -1 10 0 10 K/W ZthJC 10 -5 10 -4 10 -3 10 -2 10 -1 10 0 s tp single pulse 0.01 0.02 0.05 0.10 0.20 D = 0.50
9 Oct-21-1997
Weight: 420 g
Technische Information / Technical Information IGBT-Module IGBT-Modules BSM100GB120DN2 typ. LsCE 20 nHModulinduktivität stray inductance module Anhang C-Serie Appendix C-series Gehäuse spezifische Werte Housing specific values Gehäusemaße C-Serie Package outline C-series Appendix C-series Appendix_C-Serie_BSM100GB120DN2.xls 2001-09-20
Die in diesem Produktdatenblatt enthaltenen Daten sind ausschließlich für technisch geschultes Fachpersonal bestimmt. Die Beurteilung der Geeignetheit dieses Produktes für die von Ihnen anvisierte Anwendung sowie die Beurteilung der Vollständigkeit der bereitgestellten Produktdaten für diese Anwendung obliegt Ihnen bzw. Ihren technischen Abteilungen. In diesem Produktdatenblatt werden diejenigen Merkmale beschrieben, für die wir eine liefervertragliche Gewährleistung übernehmen. Eine solche Gewährleistung richtet sich ausschließlich nach Maßgabe der im jeweiligen Liefervertrag enthaltenen Bestimmungen. Garantien jeglicher Art werden für das Produkt und dessen Eigenschaften keinesfalls übernommen. Sollten Sie von uns Produktinformationen benötigen, die über den Inhalt dieses Produktdatenblatts hinausgehen und insbesondere eine spezifische Verwendung und den Einsatz dieses Produktes betreffen, setzen Sie sich bitte mit dem für Sie zuständigen Vertriebsbüro in Verbindung (siehe www.eupec.com, Vertrieb&Kontakt). Für Interessenten halten wir Application Notes bereit. Aufgrund der technischen Anforderungen könnte unser Produkt gesundheitsgefährdende Substanzen enthalten. Bei Rückfragen zu den in diesem Produkt jeweils enthaltenen Substanzen setzen Sie sich bitte ebenfalls mit dem für Sie zuständigen Vertriebsbüro in Verbindung. Sollten Sie beabsichtigen, das Produkt in Anwendungen der Luftfahrt, in gesundheits- oder lebensgefährdenden oder lebenserhaltenden Anwendungsbereichen einzusetzen, bitten wir um Mitteilung. Wir weisen darauf hin, dass wir für diese Fälle - die gemeinsame Durchführung eines Risiko- und Qualitätsassessments; - den Abschluss von speziellen Qualitätssicherungsvereinbarungen; - die gemeinsame Einführung von Maßnahmen zu einer laufenden Produktbeobachtung dringend empfehlen und gegebenenfalls die Belieferung von der Umsetzung solcher Maßnahmen abhängig machen. Soweit erforderlich, bitten wir Sie, entsprechende Hinweise an Ihre Kunden zu geben. Inhaltliche Änderungen dieses Produktdatenblatts bleiben vorbehalten. Terms & Conditions of usage The data contained in this product data sheet is exclusively intended for technically trained staff. You and your technical departments will have to evaluate the suitability of the product for the intended application and the completeness of the product data with respect to such application. This product data sheet is describing the characteristics of this product for which a warranty is granted. Any such warranty is granted exclusively pursuant the terms and conditions of the supply agreement. There will be no guarantee of any kind for the product and its characteristics. Should you require product information in excess of the data given in this product data sheet or which concerns the specific application of our product, please contact the sales office, which is responsible for you (see www.eupec.com, sales&contact). For those that are specifically interested we may provide application notes. Due to technical requirements our product may contain dangerous substances. For information on the types in question please contact the sales office, which is responsible for you. Should you intend to use the Product in aviation applications, in health or live endangering or life support applications, please notify. Please note, that for any such applications we urgently recommend - to perform joint Risk and Quality Assessments; - the conclusion of Quality Agreements; - to establish joint measures of an ongoing product survey, and that we may make delivery depended on the realization of any such measures. If and to the extent necessary, please forward equivalent notices to your customers. Changes of this product data sheet are reserved.