Ultra-mini Particulate Matter Sensor – Datasheet Document revision 1.3 Document release date May 2025 Document number BST-BMV080-DS000-11 Sales part number(s) 0273.017.054-1NV Notes Data and descriptions in this document are subject to change without notice. Product photos and pictures are for illustration purposes only and may differ from the real product appearance.

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 2 | 53

1 Basic description

1.1 Introduction

The BMV080 particulate matter sensor is an ultra-mini opto-electronic sensor capable of measuring particulate matter mass concentration. It delivers real-time measurements for particulate matter with diameters equal to or smaller than 2.5 µm (PM2.5). The sensor also offers mass concentration of particulate matter with diameters equal to or smaller than 1 µm (PM1) and equal to or smaller than 10 µm (PM10), enabling a comprehensive understanding of air quality across various particulate size ranges. The BMV080 measures naturally and freely moving particulate matter by using the ambient airflow close to the sensor. Its novel measurement principle, revolutionary small size, and low power consumption enable its integration into ultra-compact Internet of Things (IoT) devices such as air quality monitors, smart thermostats, smart air purifiers, and wearables. The BMV080 has the following features: Ultra-compact form factor Precise particulate matter concentration measurement Innovative fanless design Noiseless device operation No inlets or channels needed – minimum industrial design impact on the host system Maintenance free Novel principle, measuring in free space Enables dust-proof or waterproof integration

1.2 Particulate matter and health

Air pollution is a major environmental risk to health. Studies and research on airborne particulate matter and its impact on public health consistently show evidence of adverse health effects at specific exposure levels. While the range of health effects is broad, the respiratory and cardiovascular systems are the most affected by exposure to particulate matter. Adverse health effects have been demonstrated even for relatively small increases in particulate concentration compared to clean air conditions. While particulate matter comes in a vast range of particle sizes, the biggest impact on human health is from particulates in the PM2.5 range, which comprises all particles smaller than or equal to 2.5 µm in diameter. Due to its small size, PM2.5 particulates can easily enter deep into the human respiratory system and provoke serious health problems. The World Health Organization (WHO) set different air quality guidelines to assess the health effects of air pollution and thresholds for health-harmful pollution levels. As exposure to PM2.5 can cause both short-term and long-term effects, the latest WHO recommended guidelines as of 2021 (WHO global air quality guidelines, Table 0.1) provide two threshold levels related to the annual and the 24-hour mean: 5 µg/m³ annual mean 15 µg/m³ 24-hour mean Different countries worldwide use different air quality standards, also known as Air Quality Indices (AQI), to communicate current and future air pollution levels to the public. PM2.5 concentration is one of the pollutants considered in the calculation of each AQI. For example, the United States Environmental Protection Agency (EPA) defined a standard to correlate exposure to PM2.5 to air quality. Table 1 shows PM2.5-specific AQI sub-indices and the relative cautionary statements. © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 3 | 53 Table 1: PM2.5 specific AQI and cautionary statements defined by the EPA PM2.5 breakpoints (µg/m³, 24-hour average) Air quality index (AQI) category Air quality index description 0.0 – 12.0 Good Air quality is satisfactory, and air pollution poses little or no risk. 12.1 – 35.4 Moderate Air quality is acceptable. However, there may be a risk for some people, particularly those who are unusually sensitive to air pollution. 35.5 – 55.4 Unhealthy for sensitive groups Members of sensitive groups may experience health effects. The general public is less likely to be affected. 55.5 – 150.4 Unhealthy Some members of the general public may experience health effects; members of sensitive groups may experience more serious health effects. 150.5 – 250.4 Very unhealthy Health alert: the risk of health effects is increased for everyone. > 250.4 Hazardous Health warnings of emergency conditions: everyone is more likely to be affected.

1.3 Operating principle

The BMV080 sensor uses a laser-based optical technology to measure particulate matter mass concentration based on particle counts and relative particle velocities in free space, as illustrated in Figure 1. The natural ambient airflow in the proximity of the sensor is utilized in the measurement. Figure 1 shows how light is scattered after colliding with particles in different directions. The light continues at the top of the particle to indicate the light path when there is no collision. Figure 1: BMV080 sensor operating principle The measurement procedure is as follows: Laser light is emitted from the sensor and focused by the sensor lens at approximately 5 mm from the top of the sensor’s lens surface. Particles traveling in free space due to the natural ambient airflow are detected when passing through the laser focal (sensitive) region. © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 5 | 53 Table of contents

1 Basic description 2

2 Technical specifications 9

3 Dimensional drawings 14

4 Hardware integration guidelines 18

5 Software integration guidelines (Sensor driver) 35

© Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 6 | 53

6 Traceability 48

7 Product compliance 49

8 Additional material 50

9 Legal disclaimer 51

10 Document history and modifications 52

© Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 8 | 53 List of tables © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 9 | 53

2 Technical specifications

2.1 Standard test conditions

Table 2 specifies the BMV080 sensor under the laboratory standard test conditions. Deviation from the standard test conditions may impact the sensor performance. Table 2: Standard test conditions Parameter Value Unit Ambient temperature 25 ± 2 ◦C Relative ambient humidity 50 ± 10 %rH Relative particle velocity 0.1 – 1.5 m/s Relative particle flow Laminar, plane parallel – Reference instrument Aerosol particle size spectrometer LAP 322 – Particle source Arizona Road Dust (ARD) Ultrafine A1, ISO 12103-1 – Integration time 10 s Vibration suppression Disabled – Measurement algorithm High precision 1 – To precisely estimate the particle mass concentration, the BMV080 must gather sufficient statistical data. To obtain best results in low PM2.5 concentration situations (i.e., < 12µg/m³) when few particles are present in ambient air, an integration time (IT) of 10 s has been used for standard test conditions. The sensor performance is specified using the following parameters: Precision ["]: linear regression residual (how much does PM2.5 fluctuate under standard test conditions when test is repeated)2 Linearity [R]: Pearson correlation coefficient (linearity of response to proportional changes) Figure 3 shows the correlation between a single BMV080 and the reference device under standard test conditions. 2.00 1.43 1.03 0.74 0.53 0.38 0.27 0.19 0.14 0.10 400 350 300 250 200 150 100 050 100 150 200 250 300 350 400 Data Linear regression Prediction band (95%) BMV080 PM2.5 (μg/m3) Relative Particle Velocity (m/s) Reference PM2.5 (μg/m3) Figure 3: BMV080 characteristics - correlation to the reference device 1Refer to Section 5.2.1.2. 2For more details refer to Technical Specification Statement (BST-BMV080-AN002). © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 10 | 53

2.2 Sensor technical specification

This section describes the technical specification of the BMV080 sensor. Table 3: BMV080 technical specification Parameter Symbol Typical Value PM2.5 measurement range 3 – 0 – 1000 µg/m³ PM2.5 output resolution 3 – 1 µg/m³ Minimum detectable particle size 3 – 0.5 µm Relative particle velocity 3 – 0.02 – 1.5 m/s Precision 3, 4 " ± 10 µg/m³ @ 0 – 100 µg/m³ ± 10 % @ 101 – 1000 µg/m³ Linearity 3 R ≥ 0.98 @ 0 – 400 µg/m³ ≥ 0.95 @ 401 – 1000 µg/m³ Measurement modes – Continuous measurement mode Duty cycling measurement mode Measurement algorithm 5 – High precision Balanced Fast response Maximum output data rate 6 ODR 0.97 Hz Interface – SPI, I²C Average total current 7 – <68 mA @ 0.97 Hz ODR Sleep current – <30 µA Start-up time 8 tstart-up 1.9 s – trigger mode: software polling 2.9 s – trigger mode: IRQ, i.e. hardware interrupt Operating lifetime (MTTF) 9 – 10 years Sensor dimensions 10 – 4.4 mm x 3.0 mm x 20.0 mm Sensor weight – 0.092 g Laser class – Class 1, according to IEC 60825-1 Table 4 shows the absolute minimum and maximum ratings of the sensor BMV080. Stress above limits, which are stated as “absolute maximum ratings” in Table 4, may cause permanent damage to the device. These are stress ratings only and functional operation of the device under those conditions or any conditions beyond those indicated as “recommended operating conditions” is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Hence, it is recommended to perform a qualification according to the intended use-case environment. 3Specified under the standard test conditions defined in Section 2.1. Deviation from standard test conditions may impact sensor performance. Tolerance intervals cover 99 % of the population (95 % confidence interval). 4Precision is defined as variation around average PM2.5 value during stable conditions within a 90 s window after a 30 s stabilization time. 5Algorithms “High precision” and “Balanced” are only available in continuous measurement mode. 6ODR is configurable, i.e., using duty cycling measurement mode. 7During active measurement. 9This applies for a sensor in integrated condition as defined in Section 4.1.3 of this datasheet and the Integration Guidelines (BST-BMV080-AN00), assuming continuous 24-hour daily operation under standard test conditions (see Table 2) for an indoor air quality application. Actual sensor lifetime may vary depending on operating conditions. 10Refer to Table 7. © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 11 | 53 Table 4: Absolute minimum and maximum ratings Parameter Minimum Maximum Supply voltages 11 ESD Human body model (HMB) -2 kV 2 kV Charged device model (CDM) -500 V 500 V Sensor operating temperature range 12 +15 ◦C +65 ◦C Operating humidity and condensation range 13 0 %rH 95 %rH

2.3 Storage conditions

Table 5 outlines the storage conditions for the BMV080 to ensure its specified lifetime and performance. Table 5: Storage conditions for BMV080 Packing status Storage conditions Remark Temperature (◦C) Humidity rH (%) Max Storage Time BMV080 drypack sealed (as delivered) -40 to +70 not relevant 2 years Regular storage BMV080 drypack opened under air +20 to +30 < 60 (Air) 1 week Handling before integrationEquivalent to MSL3 BMV080 integrated 14 and not operated +10 to +40 < 60 (non- condensing) 18 months Handling after integration BMV080 drypack opened in N2 cabinet +20 to +30 < 30 (N2) 6 months N2 flow rate: > 3 l/min 11Supply pins are described in Table 11. 12Given self heating during operation resulting in sensor internal temperature increase of ~15 K in continuous measurement mode with the Power Optimized Configuration (Chapter 4), BMV080 is capable to operate at ambient temperatures <15◦C depending on thermal integration design. For more details, refer to Section 3.3 on thermal integration best practices in BMV080 integration guideline (BST-BMV080-AN000). 13No condensation allowed on the sensor, especially on the lens and LGA substrate areas circled below. 14Built into the final product following the guidelines in this document. © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 12 | 53

2.4 Measurement modes

It is possible to implement different measurement modes using the BMV080 sensor driver presented in Section 5. Once turned ON, the BMV080 sensor can provide a PM reading every second. Taking this into consideration, the following measurement modes can be implemented to save power consumption and increase operating lifetime.

2.4.1 Continuous measurement mode

In this mode, BMV080 delivers particle concentrations with the maximum defined Output Data Rate of 0.97 Hz. Figure 4 shows the continuous measurement mode integration timing. Figure 4: Continuous measurement mode integration timing

2.4.2 Duty cycling measurement mode

In this mode, BMV080 reports a value periodically based on a configured ‘duty cycling period’. Figure 5 shows the duty cycling measurement mode integration timing. Figure 5: Duty cycling measurement mode integration timing Note: Precision target as defined in Table 3 does not apply in case of Duty Cycling Measurement mode. Duty Cycling Measurement mode only supports the fast response measurement algorithm. © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 13 | 53

2.5 Power consumption

Table 6 shows the typical power consumption for the different measurement modes. Table 6: Power Consumption Measurement mode Duty cycling period Power consumption (mW)15 Duty cycling mode 1 min 1 measurement in 1 min 30.4 5 min 1 measurement in 5 min 6.2 10 min 1 measurement in 10 min 3.1 60 min 1 measurement in 60 min 0.6 Continuous mode 1 measurement every 1 s Not applicable 181.9 © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 14 | 53

3 Dimensional drawings

3.1 Schematic

Figure 6 shows the BMV080 package. The sensor consists of the following components: LGA package Lens Flex-PCB Figure 6: BMV080 package overview Table 7 provides the BMV080 package dimensions and is further detailed in Figure 7. A 3D CAD model of the BMV080 design to support the integration in a host system is available on request, see Section 8. Table 7: BMV080 package dimensions Parameter Nominal dimension [mm] Flex PCB size Width 5.5 (with ears of ZIF connector) 4.4 (without ears) Length 20.0 Total height 3.005 Lens height 1.83 FPC thickness 0.38 © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 15 | 53 Figure 7: BMV080 dimensional drawings (dimensions in mm)

3.2 Flex PCB

Bending of the Flex-PCB is only allowed in the bending area highlighted with red rectangle shown in Figure 8 with maximum bending angle of 90◦ in clockwise direction and 180◦ in counterclockwise direction. Minimum bending radius is 0.5 mm, as shown in Figure 9. Figure 8: BMV080 flex PCB footprint © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 17 | 53 Figure 11: Comparison of pin numbering schemes for BMV080 and ZIF connectors © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 18 | 53

4 Hardware integration guidelines

The BMV080 has 4 hardware design interfaces, shown in Figure 12. Detailed requirements for each interface are specified in the following sections: Mechanical: contains environmental considerations as well as information about footprint, handling and mounting of the sensor into the host. In addition, important advice with respect to contamination is given. Thermal: thermal connection to the host for dissipating heat generated by the sensor. Optical: optical components added by the host to the sensor optical path, e.g., optical cover. Electrical & Communication: electrical connections for power and data communication between the sensor and host. Figure 12: BMV080 hardware design interfaces

4.1 Mechanical interface

4.1.1 Environmental considerations

The BMV080 measures particulate matter mass concentration in a probing region at approximately 5 mm above the sensor lens surface. To ensure the sensor’s functionality and performance, it is recommended to follow these requirements for sensor placement: Sensor location in the host system: place the BMV080 minimum 17 mm away from sharp edges to avoid turbulent air flows that could affect the sensor performance, see Figure 13. Objects in front of the sensor (obstruction): reflections caused by objects in the optical path can influence the sensor functionality. The BMV080 software detects these events as obstructions. While occasional obstruction (e.g., by waving hands) is filtered out in the BMV080 software and does not influence the sensor performance, static obstruction (i.e., a fixed object in the obstruction-sensitive region, see Figure 14) will influence the sensor functionality. When the BMV080 software detects a static obstruction, the PM2.5 calculation is not available, and an obstruction flag is returned. Therefore, static obstructions caused by the integration into the host shall be avoided. © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 20 | 53

4.1.2 BMV080 footprint

A detailed description of the BMV080 footprint, dimensions, used connectors, and drawings can be found in Chapter 3.

4.1.3 Mounting and assembly

The mounting and assembly concept must fulfill the following requirements to ensure functional integration of the BMV080 into a host system: Mechanically fix the BMV080 in the host system Protect the BMV080 (e.g., lens) from damage Correct positioning to ensure a clear optical path for the sensor optics Enable electrical connection to the host system Enable thermal connection to the host system The mounting position within host has to ensure that no humidity (for example coming from any condensation) covers the lens, optical cover inner surface or any other part of the integrated BMV080, no contamination is applied on the lens and the inner surface of the optical cover of the integrated BMV080 (this could be achieved, e.g., by using a clean room environment for the assembly process. Manufacturing and test of the sensor at Bosch Sensortec is performed in an ISO 7 clean room environment). The following sections describe two mounting and assembly concept examples. The BMV080 is placed inside a cavity formed into the housing structure of the host system that includes the optical cover, as shown in Figure 15. The cavity’s shape and dimensions define the sensor’s position inside the housing structure and ensure the required clearance between the BMV080 and the optical cover (Section 4.3). The BMV080 needs to be fixed in the cavity from the backside, and a thermal connection needs to be enabled (Section 4.2). This can be done, for example, with a plastic component (e.g., molded polymer) that includes a metal spring and is attached to the housing structure with a clip structure. This concept has the following options: Precise control of the clearance between the BMV080 lens and the optical cover Flexibility to place the PCB for the sensor position (side by side, stacked, etc. – see Figure 16).

4.1.3.1 Concept 1: Case mounting

Figure 15: Concept 1: Case mounting © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 21 | 53 Figure 16: Placement of PCB for the sensor position Figure 17 shows an example assembly process for Concept 1 – Case mounting. Figure 17: Process flow for concept 1 - Case mounting

4.1.3.2 Concept 2: PCB mounting

The BMV080 is mounted directly on the host PCB, working simultaneously as a mechanical fixation and thermal connection. For example, BMV080 can be fixed to the host PCB using a cage system (Figure 18). Different options can be used to fix the cage system to the host PCB, for example, screws. Clearance between the BMV080 lens and cover glass has to be ensured by the fixation of the PCB in the host housing (for info about clearance, refer to Section 4.3.1). © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 23 | 53

4.1.4 Handling and mounting guidelines

During the assembly process, the following handling guidelines must be considered to avoid any damage to the sensor: Maximum forces applied to the LGA package (Figure 20) Fmax, x = 5 N Fmax, y = 5 N Fmax, z = 3 N Avoid any force on the lens Avoid any contamination on the lens surface (e.g., fingerprints, dust) Figure 20: Maximum forces applied to the LGA package

4.2 Thermal interface

The BMV080 sensor needs to be connected to a cooling system to dissipate the heat generated by the sensor. Figure 21 shows a simplified overview of a thermal setup. The lower surface of the BMV080 Flex-PCB is attached to a cooling element (e.g., a heat sink) via a thermal contact (in this case a tape). The heat sink itself is part of the host system. Figure 21: Sketch of the thermal integration situation When designing the thermal interface from the BMV080 Flex-PCB to the host, the following parameters must be considered, see Table 8. © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 24 | 53 Table 8: Given parameters for the thermal setup Parameter Value Maximum sensor operating temperature 65◦C Maximum power (continuous measurement) (Pmax) 181.9 mW The maximum sensor operating temperature is 65 ◦C, the sensor internal temperature increase is 15 K due to power dissipation in the sensor (This value is based on continuous measurement mode). Please refer to Section 3.3 in BMV080 integration guideline for more details on thermal integration best practices.

4.3 Optical interface

In the host system, the BMV080 has to be integrated behind an optical cover to protect the lens from contamination (e.g., fingerprints, dust) and mechanical damage in the application. This section covers the mechanical and optical properties of the optical cover.

4.3.1 Mechanical properties

Optical cover thickness ( d) and clearance ( ff) between the lens and optical cover: the sensor-sensitive region is located approx. 5 mm above the lens surface. It must be ensured that the sensitive region is above the optical cover – outside the housing in free air. Optical window width (˘): the optical cover has to be wide enough to transmit the laser beams. Maximum tilt angle (¸) between the optical cover and the BMV080: the lens surface and the optical cover have to be almost parallel to avoid distortion of the optical signal. Figure 22 and Table 9 show the mechanical requirements of the optical interface. Figure 22: Sketch of the optical interface Table 9: Optical interface mechanical properties Parameter Symbol Value Unit Optical cover thickness d 0.3 ≤ d ≤ 0.8 mm Optical window width ˘ ≥ 1.4 mm Tilt angle ¸ ≤ 4 ◦ Clearance between the top of the BMV080 lens and the bottom of the optical cover ff 0.2 ± 0.1 mm © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 25 | 53 Scratches and damage on the optical cover can affect the sensor performance. A hard material like glass is recommended (e.g., Corningr Gorillar Glass 6). The optical cover must be kept free from fingerprints, dust, and other impurities and contamination.

4.3.2 Optical properties

Refractive index: this parameter influences the laser beam shape, and therefore it needs to be specified to avoid affecting the sensor performance Transmissivity: the cover glass must allow the transmission of the laser beams. A transmissivity below specifications will decrease the optical signal intensity, thus affecting the sensor functionality. Optical properties are specified in Table 10. Table 10: Properties of optical cover Parameter Typical value Refractive index 1.45 – 1.77 for –= 850 nm Transmissivity ≥ 90 % for an angle of incidence of 30◦, P-polarization, –= 850 nm Additional requirements to the optical cover: Optical surface roughness needed to avoid any beam distortion Avoid any polarization filter

4.4 Electrical and communication interface

The BMV080 is connected to the host system by the electrical interface for data communication and power supply.

4.4.1 Electrical interface

4.4.1.1 Pin configuration and function

Figure 23 shows a pin schematic of the BMV080. Figure 24 shows the BMV080 flex-PCB. Table 11 shows the functional description of each pin. Figure 23: BMV080 pin schematic © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 27 | 53 Table 11: BMV080 pin description Label Pin no. Type 16 Description VDDL 1 P Laser supply voltage. The laser supply voltage is 3.3 V and the supply pin should be decoupled from VSSA by >1 µF. VDDA 3 P ADC supply voltage. The ADC supply voltage is 2.5 V– 3.3 V which should be decoupled from VSSA by >1 µF. VDDD 10 P Digital supply voltage. The digital supply voltage is 2.5 V to 3.3 V which should be decoupled from VSSD by >1 µF. VDDIO 8 P Interface power supply. The interface power supply is from 1.2 V (min) to 3.3 V (max), with 1.8 V being the typical value. This pin is typically connected to the same supply of the host interface (e.g., application processor, microcontroller, or FPGA). PS 7 DI Protocol select. Logic input. This pin is used to configure the type of serial interface, SPI or I²C. The SPI protocol is selected if this pin is connected to a logic low (VSSD). If this pin is connected to a logic high (VDDIO), the I²C protocol is selected. Note: If this pin is not connected (not recommended), the I²C protocol is selected. The pin state is latched during power-up by the digital core. VSSA 2 GND Analog ground. This pin is the ground reference for all analog domains, namely VDDL and VDDA. Connecting VSSA and VSSD as close as possible to the BMV080 pin header is recommended. VSSD 9 GND Digital ground. This pin is the ground reference for all digital domains, namely VDDD and VDDIO. Connecting VSSA and VSSD as close as possible to the BMV080 pin header is recommended. SCK 6 DI Serial clock. Digital input. This pin functions as serial input for both serial interface protocols (SPI and I²C). MOSI 5 DI/DO SPI: This pin functions as Master Out Slave In (MOSI). I²C: This pin functions as a Serial Data line (SDA). MISO 11 DI/DO SPI: This pin functions as Master In Slave Out (MISO). I²C: This pin functions as I²C Address Bit 0 (IAB0). IAB0 allows adjusting the I²C Address Bit 0 of the slave by applying a logic low (VSSD) or logic high (VDDIO). CSB 4 DI SPI: This pin functions as not Slave Select (nSS). I²C: This pin functions as I²C Address Bit 1 (IAB1). IAB1 allows adjusting the I²C Address Bit 1 of the slave by applying a logic low (VSSD) or logic high (VDDIO). IRQ 12 DO Interrupt line. Digital out. Active low. Internal pull-up is enabled by default for IRQ pin. Do not connect 13 DO Keep pin floating. Do not connect to ground or apply voltage.

4.4.1.2 Proposal for filtering signal errors

Strong disturbing signals on the SCK pin may influence the measurement results of the BMV080. In an environment where strong disturbance signals are present, the SCK pin could be protected with a suitable low pass filter, which filters out the disturbance but allows normal communication. 16P = power supply, DI = digital in, DO = digital out, GND = ground. © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 28 | 53

4.4.1.3 Power domains

The BMV080 has four power domains, listed in Table 12. The passive components specific to the four BMV080 power domains are already included on the flex-PCB. Table 12: Power domains specification and current consumption Power Electrical specification Power supply Absolute Current consumption domain Min Max rejection ration maximum Sleep Measurement rating mode mode VDDIO17 1.2 V - 5 % 3.3 V + 5 % Ensure dynamically the listed min. and max. supply values 3.6 V <3 µA 0.8 mA VDDD 2.5 V - 5 % 3.3 V + 5 % Ensure dynamically the listed min. and max. supply values 3.6 V <15 µA 21.6 mA VDDL 3.3 V - 5 % 3.3 V + 5 % 100 mV VPP at any frequency 3.6 V <3 µA 18.29 mA VDDA 2.5 V - 5 % 3.3 V + 5 % 100 mV VPP at any frequency 3.6 V <3 µA 27.0 mA

4.4.1.4 Connection diagrams

The following connection diagrams are examples of how to electrically connect the BMV080 to a host system. Other configurations are possible. Common acronyms used in every connection diagram are Voltage Battery (VBAT) and Power Management Integrated Circuit (PMIC).

4.4.1.4.1 Single supply rail

Figure 26 illustrates the simplest connection diagram possible. All four power domains of the BMV080 sensor, i.e., VDDL, VDDA, VDDD, and VDDIO, are powered by the same rail (3.3 V). The power consumption of the BMV080 is the highest since VDDA and VDDD are supplied at the highest voltage possible. Figure 26: Power-supply configuration with a single supply rail 17Reduced SPI speed for VDDIO < 1.8 V. © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 29 | 53

4.4.1.4.2 Power optimized configuration

Figure 27 shows the connection diagram targeting lowest power consumption for each BMV080 power domain while keeping the full SPI speed. Therefore, each power domain is supplied at its lowest allowed voltage (See Section 4.4.1.3): VDDL is supplied at 3.3 V VDDA and VDDD are supplied at 2.5 V VDDIO is supplied by a second PMIC that also supplies the host (e.g., Application Processor, Microcontroller, or FPGA). Figure 27: Power-supply configuration with the lowest voltage level Since VDDD and VDDIO do not share the same power rail, a power-up sequence has to be implemented to ensure the latching of the right information during start-up (see Figure 28). For this purpose, it is possible to use a dedicated PMIC (PMIC #2) controlled by the host. The sequence is as follows: 1. PMIC #1 supplies the host and also provides VDDIO to BMV080 2. The host boots up. After the required period, a digital output (DO) of the host is used to enable the PMIC #2 3. PMIC #2 supplies the remaining domains of BMV080, i.e., VDDL, VDDA, and VDDD Whenever the BMV080 is not actively measuring, further energy consumption can be saved by turning completely off the BMV080 sensor instead of putting it into sleep mode; a possible realization of this strategy would consist of disabling PMIC #2 through an enable command generated by the host application processor/microcontroller/FPGA. © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 30 | 53 Figure 28: Power-up sequence diagram

4.4.1.4.3 Separated power supply for analog and digital domains

The separation of analog and digital power domains allows the selection of dedicated PMICs for noise and efficiency. While the low noise PMIC #2 supplies the analog domains VDDL and VDDA, the highly efficient PMIC #1 supplies the digital domains, including the host (See Figure 29). Also, the coupling of digital noise from the digital to the analog domain can be efficiently suppressed. Figure 29: Power-supply configuration with separated analog and digital domains

4.4.2 Communication interface

The sensor supports the I ²C and SPI digital interfaces, where it acts as a slave for both protocols. The I ²C interface supports the Standard, Fast and High Speed modes. The SPI interface supports both SPI mode 0 (CPOL = CPHA = ‘0’) and mode 3 (CPOL = CPHA = ‘1’) in 4-wire configuration.

4.4.2.1 Interface selection

Interface selection is done automatically based on PS (protocol select) status. If PS is connected to VDDIO, the I ²C interface is active. If PS is pulled down, the SPI interface is activated. After power-up, the level on PS is latched. Hence © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 31 | 53

4.4.2.2 Pin assignment

Table 13: Pin functions depending on selected protocol Pin no. BMV080 ZIF connector SPI I²C

6 Serial Clock (SCK) SCL (external pull-up only)

5 Master Out Slave In (MOSI) SDA (external pull-up only)

4 Chip Select (CSB), chip-select, low-active Selection LSB of device address

(see 4.4.2.4.1 I²C device address)

11 Master In Slave Out (MISO) Selection LSB of device address

(see 4.4.2.4.1 I²C device address)

7 Protocol Selection (PS)

high level = I²C low level = SPI Attention: The MOSI pin has specific usage during serial data communication, depending on the protocol: SPI, 4-wire: uni-directional master-out data SPI, I²C: bi-directional serial data (external pull-up only)

4.4.2.3 SPI protocol

The SPI interface is compatible with SPI mode 0 (CPOL = CPHA = ‘0’) and mode ‘3’ (CPOL = CPHA = ‘1’). The automatic selection between mode 0 and 3 is determined by the value of SCK after the CSB falling edge. Frequency 1 MHz – 10 MHz 18 4 wire connection

4.4.2.3.1 SPI 4-wire read mode 0

A read transfer consists of 16-bit header information clocked out on the MOSI line followed by reading an arbitrary number of 16-bit words from the MISO line. The Chip Select Signal (CSB) stays low during the whole transfer. CSB SCK MOSI header<15:0> MISO data<15:0> Slave to Master Master to Slave Header Payload: Read Data Figure 30: SPI 4-wire read mode 0

4.4.2.3.2 SPI 4-wire write mode 0

A write transfer consists of 16-bit header information followed by an arbitrary number of 16-bit words of payload. Header and payload are clocked out on the MOSI line. The Chip Select Signal (CSB) stays low during the whole transfer. 18reduced SPI speed for VDDIO < 1.8 V. © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 32 | 53 CSB SCK MOSI header<15:0> data<15:0> MISO Slave to Master Master to Slave Header Payload: Write Data Figure 31: SPI 4-wire write mode 0

4.4.2.4 I²C protocol

Standard-mode (100 kHz) Fast-mode (400 kHz) Fast-mode Plus (Fm+, 1 MHz, recommended) The protocol is compliant to the I2C specification UM10204 Rev. 3, with the following restrictions: 7-bit device addressing only No clock stretching

4.4.2.4.1 I²C address selection

The I²C device address can be selected depending on the unused CSB and MISO pin. These pins cannot be left floating; if left floating the I²C address will be undefined! This selection is latched after power-up and cannot be altered afterwards. Table 14: Host interface - I²C device address selection 1 0 1 0 1 CSB MISO Below are some other I²C address selection possibilities: CSB = 0, MISO = 0, address = 0x54 CSB = 0, MISO = 1, address = 0x55 CSB = 1, MISO = 0, address = 0x56 CSB = 1, MISO = 1, address = 0x57

4.4.2.4.2 I²C read

A read sequence consists of two consecutive I²C transfers: 16 bits of header followed by an arbitrary number of payload I2C Start Device address Ack Header MSB Ack Header LSB Ack Stop Start Device address Ack Payload MSB Ack Payload LSB Nack Stop Slave to Master Master to Slave Header Payload Figure 32: I²C read © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 33 | 53

4.4.2.4.3 Complete I²C write

A write sequence consists of two consecutive I²C transfers: 16 bits of header followed by an arbitrary number of payload I2C Start Device address Ack Header MSB Ack Header LSB Ack Payload MSB Ack Payload LSB Ack Stop Slave to Master Master to Slave Header Payload Figure 33: Complete I²C write

4.4.2.4.4 I²C header transfer

The header is transferred by sending the slave address in write mode (R/W= ’0’), resulting in slave address 10101XX0 (‘X’ is determined by the state of CSB and MISO pin). Then the master sends the 16 bits of header information MSB first. The reception of a byte is acknowledged by the slave. The transaction is ended by a stop condition. Figure 34 illustrates the header transmission. The device address is transferred first, followed by the R=W flag set to 0. Depending on the access type, the transfer is continued or followed by another one: Write transfer: with R/W flag set to 0, is the header transmission plus following payload data. Read transfer: with R/W flag set to 1, assumes a preceding single header transmission without payload data. It is up to the user to either follow-up with a new header transmission or another read access. SCL SDA devaddr<6:0> header<15:8> header<7:0> Slave to Master Master to Slave Start Ack Header (MSBs) Ack Header (LSBs) Ack Stop Figure 34: I²C header transfer

4.4.2.4.5 I²C data read

After the header is transferred, a read transfer can be issued by sending the slave address in read mode (R/ W = ‘1’), resulting in slave address 10101XX1 (‘X’ is determined by state of CSB and MISO pin). Then the master can read an arbitrary number of 16-bit words, MSB first. The master acknowledges the reception of every byte. Data is read until a NACK (issued by the slave) followed by a stop condition occurs. SCL SDA devaddr<6:0> Data 0 <15:8> Data 0 <7:0> Data 1 <15:8> Data N <7:0> Slave to Master Master to Slave Start Device Address R/W Ack Data 0 (MSBs) Ack Data 0 (LSBs) Ack Data 1 (MSB)s Data N (LSB)s Nack Stop Figure 35: I²C data read

4.5 Maintenance and service

Due to its unique measurement principle, the BMV080 particulate matter sensor does not comprise an air inlet or any for the user to perform regular maintenance or service tasks. © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 34 | 53 However, it is possible that dust, fingerprints, or other contamination accumulates on the outer surface of the optical cover of the host system. This might lead to a slight impact on the sensor performance. Hence, it can be beneficial to clean the optical cover surface using a wiping tissue from time to time. A suitable tissue shall be used to avoid scratches on the optical cover. © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 35 | 53

5 Software integration guidelines (Sensor driver)

The BMV080 sensor driver is the interface between the sensor and the user application on the host system. Bosch Sensortec provides sensor drivers to run on the host application processor. Figure 36: The sensor driver is the communication channel between the BMV080 and the user application The sensor driver includes a complete set of ready-to-use Application Programming Interfaces (APIs) to simplify the development of a host application. Section 5.2 describes these APIs in detail. These functions can be easily used to develop a user application specific to a determined use case.

5.1 Host requirements

Table 15 shows the technical requirements for the current version of the BMV080 sensor driver. Table 15: BMV080 sensor driver technical requirements for embedded systems Supported platforms Compiler ROM * RAM ARM Cortex-M4F arm-none-eabi-gcc 64 kB 17 kB 11 kB ARM Cortex-M4 arm-none-eabi-gcc 64 kB 17 kB 11 kB ARM Cortex-M33F arm-none-eabi-gcc 63 kB 17 kB 11 kB ARM Cortex-M0+ arm-none-eabi-gcc 66 kB 17 kB 11 kB ARM Cortex-M7F arm-none-eabi-gcc 62 kB 17 kB 11 kB ESP32 xtensa-esp32-elf-gcc 74 kB 17 kB 12 kB ESP32-S2 xtensa-esp32s2-elf-gcc 80 kB 17 kB 12 kB ESP32-S3 xtensa-esp32s3-elf-gcc 74 kB 17 kB 12 kB Raspberry Pi ARMv6 32Bit arm-linux-gnueabihf-gcc 89 kB 18 kB 18 kB Raspberry Pi ARMv8-A 32Bit arm-linux-gnueabihf-gcc 89 kB 18 kB 18 kB Raspberry Pi ARMv8-A 64Bit aarch64-linux-gnu-gcc 93 kB 18 kB 19 kB *excluding 20 kB (approx.) for the standard library dependencies for different platforms. Heap memory allocation is not used. The compilation has been done in release mode with an -Os optimization flag. The support for other platforms is being considered case-by-case. To request support for a particular embedded platform, please contact your Bosch Sensortec representative. © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 36 | 53

5.2 Application programming interface

5.2.1 Typedefs

5.2.1.1 Handles

5.2.1.1.1 bmv080_handle_t Typedef typedef void* bmv080_handle_t; Summary Unique handle for a sensor unit 5.2.1.1.2 bmv080_sercom_handle_t Typedef typedef void* bmv080_sercom_handle_t; Summary Unique handle for serial communication, i.e., the hardware connection to the sensor unit

5.2.1.2 Enumerations

5.2.1.2.1 bmv080_status_code_t Typedef typedef enum E_BMV080_OK = 0, [...] E_BMV080_WARNING_FIFO_FULL = 215, [...] E_BMV080_ERROR_NULLPTR = 100, [...] } bmv080_status_code_t; Summary Status codes of BMV080 sensor driver 5.2.1.2.2 bmv080_measurement_algorithm_t Typedef typedef enum E_BMV080_MEASUREMENT_ALGORITHM_FAST_RESPONSE = 1, E_BMV080_MEASUREMENT_ALGORITHM_BALANCED = 2, E_BMV080_MEASUREMENT_ALGORITHM_HIGH_PRECISION = 3 } bmv080_measurement_algorithm_t; Summary Possible measurement algorithms for BMV080 sensor driver seen as follows 1. Fast response, recommended for use-cases which require BMV080 measurements with best response time (low latency). 2. Balanced, recommended for use-cases which require BMV080 measurements with a good balance between precision & fast response time. 3. High precision, recommended for use-cases which require BMV080 measurements with optimum precision performance. © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 37 | 53

5.2.1.3 Structure definitions

5.2.1.3.1 bmv080_output_t Typedef typedef struct float runtime_in_sec; float pm2_5_mass_concentration; float pm1_mass_concentration; float pm10_mass_concentration; float pm2_5_number_concentration; float pm1_number_concentration; float pm10_number_concentration; bool is_obstructed; bool is_outside_measurement_range; float reserved_0; float reserved_1; float reserved_2; struct bmv080_extended_info_s *extended_info; } bmv080_output_t; Summary The output structure is updated by bmv080_serve_interrupt when sensor output is available. name unit description runtime_in_sec s Time passed since the start of the measurement cycle pm2_5_mass_concentration µg/m3 PM2.5 mass concentration pm1_mass_concentration µg/m3 PM1 mass concentration pm10_mass_concentration µg/m3 PM10 mass concentration pm2_5_number_concentration particles/cm3 PM2.5 number concentration pm1_number_concentration particles/cm3 PM1 number concentration pm10_number_concentration particles/cm3 PM10 number concentration is_obstructed N/A Flag to indicate whether the sensor is obstructed and cannot perform a valid measurement. is_outside_measurement_ range N/A Flag to indicate whether the PM2.5 concentration is outside the specified measurement range (0 – 1000 ug/m3) reserved_0 N/A For internal use only reserved_1 N/A For internal use only reserved_2 N/A For internal use only bmv080_extended_info_s N/A For internal use only © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 38 | 53

5.2.1.4 Callbacks

5.2.1.4.1 bmv080_callback_read_t Callback typedef int8_t(*bmv080_callback_read_t) bmv080_sercom_handle_t sercom_handle, uint16_t header, uint16_t* payload, uint16_t payload_length Summary Function pointer for reading an array of payload_length words of 16-bit payload All data, header, and payload are transferred as MSB first Precondition Both header and payload words are 16-bit and combined. A payload is only transferred on a complete transmission of 16 bits. Burst transfers, i.e., reading a header followed by several payload elements, must be supported. Postcondition N/A Arguments sercom_handle Handle for a serial communication interface to a specific sensor unit header Header information for the following payload * payload Payload to be read consisting of 16-bit words payload_length payload_length Number of payload elements to be read Return Value E_BMV080_OK if successful. Otherwise, the return value is a BMV080 status code. 5.2.1.4.2 bmv080_callback_write_t Callback typedef int8_t(*bmv080_callback_write_t) bmv080_sercom_handle_t sercom_handle, uint16_t header, const uint16_t* payload, uint16_t payload_length Summary Function pointer for writing an array of payload_length words of 16-bit payload All data, header, and payload are transferred as MSB first. Precondition Both header and payload words are 16-bit and combined. A payload is only transferred on a complete transmission of 16 bits. Burst transfers, i.e., reading a header followed by several payload elements, must be supported. Postcondition N/A Arguments sercom_handle Handle for a serial communication interface to a specific sensor unit header Header information for the following payload * payload Payload to be written consisting of 16-bit words payload_length Number of payload elements to be read Return Value E_BMV080_OK if successful. Otherwise, the return value is a BMV080 status code. © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 39 | 53 5.2.1.4.3 bmv080_callback_delay_t Callback typedef int8_t(*bmv080_callback_delay_t) uint32_t duration_in_ms Summary Function pointer for executing a software delay operation Precondition N/A Postcondition N/A Arguments duration_in_ms Duration of the delay in milliseconds Return Value E_BMV080_OK if successful. Otherwise, the return value is a BMV080 status code. 5.2.1.4.4 bmv080_callback_data_ready_t Callback typedef void(*bmv080_callback_data_ready_t) bmv080_output_t bmv080_output, void* callback_parameters Summary Function pointer for handling the sensor’s output information Precondition N/A Postcondition N/A Arguments bmv080_output Structure containing sensor output * callback_parameters are user-defined parameters to be passed to the callback function. Return Value E_BMV080_OK if successful. Otherwise, the return value is a BMV080 status code.

5.2.2 Driver version

5.2.2.1 bmv080_get_driver_version Function bmv080_status_code_t bmv080_get_driver_version uint16_t* major, uint16_t* minor, uint16_t* patch, char git_hash[12], int32_t num_commits_ahead Summary Get the version information of this sensor driver Precondition No preconditions apply, i.e., no connected sensor unit or sensor driver handle is required. Postcondition N/A Arguments * major Major version number * minor Minor version number * patch Patch version number git_hash[12] Git hash of the build num_commits_ahead Number of commits ahead from build Return Value E_BMV080_OK if successful. Otherwise, the return value is a BMV080 status code. © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 40 | 53

5.2.3 Sensor management

5.2.3.1 bmv080_open Function bmv080_status_code_t bmv080_open bmv080_handle_t* handle const bmv080_sercom_handle_t sercom_handle, const bmv080_callback_read_t read, const bmv080_callback_write_t write, const bmv080_callback_delay_t delay_ms Summary Open a sensor unit by initializing a new handle. The handle must be NULL initialized. Precondition Must be called first to create the handle required by other functions. Postcondition The handle must be destroyed via bmv080_close. Arguments * handle Unique handle for a sensor unit sercom_handle Unique handle for a serial communication interface read Function pointer for reading from an endpoint write Function pointer for writing to an endpoint delay_ms Function pointer for a delay in milliseconds Return Value E_BMV080_OK if successful. Otherwise, the return value is a BMV080 status code. 5.2.3.2 bmv080_reset Function bmv080_status_code_t bmv080_reset const bmv080_handle_t handle Summary Reset a sensor unit by performing a reset of the hardware and software. Precondition A valid handle generated by bmv080_open is required. Postcondition Any parameter changed through bmv080_set_parameter is reverted to its default. Arguments handle Unique handle for a sensor unit Return Value E_BMV080_OK if successful. Otherwise, the return value is a BMV080 status code. 5.2.3.3 bmv080_close Function bmv080_status_code_t bmv080_close bmv080_handle_t* handle Summary Close the sensor unit. Precondition Must be called last to destroy the handle created by bmv080_open. Postcondition N/A Arguments * handle Unique handle for a sensor unit Return Value E_BMV080_OK if successful. Otherwise, the return value is a BMV080 status code. © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 41 | 53

5.2.4 Sensor identification

5.2.4.1 bmv080_get_sensor_id Function bmv080_status_code_t bmv080_get_sensor_id const bmv080_handle_t handle, char id[13] Summary Get the sensor ID of a sensor unit. Precondition A valid handle generated by bmv080_open is required. The application must have allocated the char array id with a size of 13 elements. Postcondition N/A Arguments handle Unique handle for a sensor unit id Character array of 13 elements Return Value E_BMV080_OK if successful. Otherwise, the return value is a BMV080 status code.

5.2.5 Particulate matter measurement

5.2.5.1 User application flows

This section introduces two typical types of application flow by means of examples.

5.2.5.1.1 Continuous measurement

Figure 37 presents an activity diagram illustrating the process of conducting a continuous measurement, which is an unlimited duration measurement. The application is required to execute the sub-programs (highlighted in purple) from the BMV080 library. The measurement process begins by establishing a connection with the BMV080. Following this, measurement parameters can be set using the can be set using the bmv080_set_parameter() function. Initially, the sensor operates in sleep mode, drawing only standby current (as detailed in Table 12). A measurement is initiated by calling bmv080_start_continuous_measurement(), which activates the continuous measurement of particle density. The service function bmv080_serve_interrupt() fetches and processes data from the BMV080. Sensor output is provided through the callback function(), which is triggered every second and is implemented on application level. The bmv080_serve_interrupt() function can be invoked either at regular intervals (at least once per second) or event-driven, based on an external interrupt. The measurement process can be halted by calling bmv080_stop_measurement(). This action puts the BMV080 back into sleep mode, reducing the current consumption to standby levels. This setup allows for the implementation of various end-user applications. For instance, PM data can be logged into a database, displayed in real-time, or streamed directly to the cloud. © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 43 | 53 BMV080 Sleep Standby Active Host system Idle Init Measuring 1.9s (if using IRQ 2.9s) 1.03s System running BMV080 API If bmv080_serve_interrupt() is trigered by the IRQ line, the first measurement will be available after 2.9s. bmv080_serve_interrupt() should be called at least once per second. New measurements will be provided through bmv080_data_ready_callback() every 1.03s. bmv080_open() bmv080_set_parameter() bmv080_start_continuous_measurement() bmv080_serve_interrupt() bmv080_serve_interrupt() bmv080_data_ready_callback() bmv080_serve_interrupt() bmv080_data_ready_callback() Figure 38: Start-up sequence in case of Continuous Measurement Mode

5.2.5.1.2 Duty cycling measurement

Figure 39 is an activity diagram that shows how to perform a duty cycling measurement – repeating numerous measure- ments separated by a pause. The main difference from continuous measurement is the duty cycling measurement will pause before repeating the next measurement cycle. For duty cycling measurement, the service function bmv080_serve_interrupt() must be invoked at regular intervals, at least once per second. Note: the event-driven approach using an external interrupt is not compatible with duty cycling measurement. The period at which new data becomes available is determined by the duty_cycling_period parameter (refer to the bmv080_set_parameter() function for more details). During the sleep time of the duty cycling period, the sensor will be in sleep mode, limiting current consumption to standby levels. For more details, see Section 2.4.2. Data availability is signaled through the callback function bmv080_data_ready_callback(), which is triggered once every duty_cycling_period has elapsed. This setup allows for the implementation of various end-user applications. For instance, PM data can be logged into a database, displayed in real-time, or streamed directly to the cloud. Figure 39: Flow diagram of a duty cycling measurement © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 45 | 53 5.2.5.4 bmv080_serve_interrupt Function bmv080_status_code_t bmv080_serve_interrupt const bmv080_handle_t handle, bmv080_callback_data_ready_t data_ready, void* callback_parameters Summary Serve an interrupt using a callback function. Precondition A valid handle generated by bmv080_open is required with the sensor unit currently in measurement mode via bmv080_start_continuous_measurement or bmv080_start_duty_cycling_measurement. The application can call this function whenever the sensor or the application triggers an interrupt. This interrupt may be a software timeout (e.g., at least once per second) or a hardware interrupt (e.g., FIFO watermark exceeded). This function tolerates frequent, random, or rare calls to a certain extent. However, not calling bmv080_serve_interrupt over longer periods might impair the measurement mode since events could be missed. In continuous mode, new sensor output is available every second. Hence, data_ready is called once every second of the sensor unit uptime. For example, if bmv080_serve_interrupt was called 5 s after bmv080_start_continuous_measurement, the callback function data_ready would subsequently be called five times to report the collected sensor output of each period. In duty cycling mode, new sensor output is available every duty cycling period. Hence, data_ready is called at the end of the integration time, once every duty cycling period. In this case, bmv080_serve_interrupt must be called at least once every second. The recommendation is to call this function based on hardware interrupts. The caller application provides the callback function bmv080_callback_data_ready_t and the according callback_parameter. Postcondition The interrupt condition is served, e.g., FIFO is fetched, or the ASIC condition is solved. Arguments handle Unique handle for a sensor unit data_ready User-defined callback function, which is called when sensor output is available callback_parameters User-defined parameters to be passed to the callback function Return Value E_BMV080_OK if successful. Otherwise, the return value is a BMV080 status code. 5.2.5.5 bmv080_stop_measurement Function bmv080_status_code_t bmv080_stop_measurement const bmv080_handle_t handle Summary Stop particle measurement. Precondition valid handle generated by bmv080_open is required, and the sensor unit entered measurement mode via bmv080_start_continuous_measurement or bmv080_start_duty_cycling_measurement. Must be called at the end of a data acquisition cycle to ensure that the sensor unit is ready for the next measurement cycle. Postcondition The sensing mode reduces energy consumption. Arguments handle Unique handle for a sensor unit Return Value E_BMV080_OK if successful. Otherwise, the return value is a BMV080 status code. © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 46 | 53

5.2.6 Customization

5.2.6.1 bmv080_get_parameter Function bmv080_status_code_t bmv080_get_parameter const bmv080_handle_t handle, const char* key, void* value Summary Get a parameter. The table called "Parameters to get" lists the available parameters with their keys and the expected types. This function can be called multiple times and is optional. Precondition A valid handle generated by bmv080_open is required. Postcondition N/A Arguments handle Unique handle for a sensor unit key Key of the parameter to get value Value of the parameter cast as void-pointer Key Type Unit Description path char* N/A Path to directory where log files are written. The maximum allowed length is 256 characters, which must be pre-allocated. error_logging bool N/A Enable/disable logging of error frames reported by the sensor in a CSV file. The filename format is <yyyymmddTHHMMSS>_<SensorID>_- errorFramesOutput.csv. 19 meta_data_logging bool N/A Enable/disable logging of metadata reported by the sensorin a CSV file. The filename format is <yyyymmddTHHMMSS>_<SensorID>_- metaDataOutput.csv. 19 pm_logging bool N/A Enable/disable logging of PM data in a CSV file. The filename format is <yyyymmddTHHMMSS>_- <SensorID>_postProcessorOutput.csv. 19 integration_time float s Measurement window for computing PM value. In duty cycling mode, this also includes the sensor ON time. The default is 10 s. duty_cycling_period int s Duty cycling period (sum of integration time and sensor OFF / sleep time). Duty cycling period must be greater than integration time by at least 2 s. do_obstruction_- detection bool N/A Enable/disable obstruction notifier. do_vibration_- filtering bool N/A Enable/disable vibration filtering. measurement_- algorithm bmv080_ mea- surement_ al- gorithm_t N/A Selection of measurement algorithm based on the use case. Default value is E_BMV080_MEASUREMENT_- ALGORITHM_HIGH_PRECISION. For a duty cycling measurement, this parameter is fixed to E_BMV080_- MEASUREMENT_ ALGORITHM_FAST_RESPONSE. Return Value E_BMV080_OK if successful. Otherwise, the return value is a BMV080 status code. © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 47 | 53 5.2.6.2 bmv080_set_parameter Function bmv080_status_code_t bmv080_set_parameter const bmv080_handle_t handle, const char* key, void* value Summary Set a parameter. The table “Parameters to set” lists the available parameters with their keys and the expected types. This function can be called multiple times and is optional. Precondition valid handle generated by bmv080_open is required. This function must be called before bmv080_start_continuous_measurement or bmv080_start_duty_cycling_measurement in order to apply the parameter in the configuration of particle measurement. Postcondition N/A Arguments handle Unique handle for a sensor unit key Key of the parameter to set value Value of the parameter cast as void-pointer Key Type Unit Description path char* N/A Path to directory where log files are written. The maximum allowed length is 256 characters, which must be pre-allocated. error_logging bool N/A Enable/disable logging of error frames reported by the sensor in a CSV file. The filename format is <yyyymmddTHHMMSS>_<SensorID>_- errorFramesOutput.csv. 19 meta_data_logging bool N/A Enable/disable logging of metadata reported by the sensorin a CSV file. The filename format is <yyyymmddTHHMMSS>_<SensorID>_- metaDataOutput.csv. 19 pm_logging bool N/A Enable/disable logging of PM data in a CSV file. The filename format is <yyyymmddTHHMMSS>_- <SensorID>_postProcessorOutput.csv. 19 integration_time float s Measurement window for computing PM value. In duty cycling mode, this also includes the sensor ON time. The default is 10 seconds. duty_cycling_period int s Duty cycling period (sum of integration time and sensor OFF / sleep time). Duty cycling period must be greater than integration time by at least 2 seconds. The default is 30 seconds. do_obstruction_ detection bool N/A Enable/disable obstruction notifier. do_vibration_- filtering bool N/A Enable/disable vibration filtering. measurement_- algorithm bmv080_ mea- surement_ al- gorithm_t N/A Selection of measurement algorithm based on the use case. Default value is E_BMV080_MEASUREMENT_- ALGORITHM_HIGH_PRECISION. For a duty cycling measurement, this parameter is fixed to E_BMV080_- MEASUREMENT_ ALGORITHM_FAST_RESPONSE. Return Value E_BMV080_OK if successful. Otherwise, the return value is a BMV080 status code. 19File logging is available only for Windows x86/x64 and Raspberry Pi, but not for embedded platforms (e.g., ARM Cortex-M, Xtensa ESP32, etc). © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 48 | 53

6 Traceability

A laser marking (DMC and OCR code) on the sensor is used to identify the single parts and to enable traceability through the production and supply chain. Table 16: BMV080 marking convention General Marking method Laser (Direct part marking) Marking position Refer to drawing Information about DMC Marking type DMC, ECC 200 (ISO/IEC 16022) Module size 0.130 ± 0.01 mm Symbol size 14 x 14 (Row × column) nominal 1.82 mm × 1.82 mm Marking depth < 15 µm Marking quality (Grade) A-C (ISO/IEC TR 29158) Information capacity DMC 16 (Numeric) Digit 1, digit 2, ..., digit 16 Digits 1 – 7 Reserved Digit 8 0 = 2020 1 = 2021 ... 9 = 2029 Year DMC sequence Digits 9 – 10 01 ~ 53 Work week Digit 11 1 = Sun 2 = Mon ... 7 = Sat Day Digits 12 – 16 Reserved Information about marking text Font type Arial1 Symbol size 2.15 mm × 0.4 mm Information capacity marking text 6 (Numeric) Digit 1, digit 2, ..., digit 6 Marking text sequence Digit 1 0 = 2020 1 = 2021 ... 9 = 2029 Year Digits 2 – 3 01 ~ 53 Work Week Digit 4 1 = Sun 2 = Mon ... 7 = Sat Day Digits 5 – 6 Reserved © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 49 | 53

7 Product compliance

7.1 Environmental safety

7.1.1 RoHS

BMV080 is in compliance with the consolidated RoHS directive 2011/65/EU of the European Parliament and Council regarding the restriction of hazardous substances in electrical and electronic equipment.

7.1.2 Halogen content

BMV080 complies with the halogen-free definition of the industry standard IEC 61249 for materials utilized in printed boards and other interconnecting structures.

7.2 Laser safety

The design of the BMV080 limits the emitted optical output power to 0.5 mW. The BMV080 is laser class 1 compliant.

7.2.1 Conformity and classification

laser class 1 compliant according to norm: “Safety of laser products –Part 1: Equipment classification and require- ments”, IEC60825-1 Edition 3.0 (2014), respectively, EN 60825-1:2014/A11:2021. a consumer product according to norm “Safety of laser products – Particular Requirements for Consumer Laser Products”, EN 50689 (2021). compliant with FDA performance standards for laser products except for conformance with IEC 60825-1 Edition 3.0, as described in Laser Notice No. 56, dated May 8, 2019. This has independently been confirmed by Seibersdorf Laboratories (Test report LE-L176/23, 2024-02-28). The Laser Class 1 classification was achieved by using C-samples on EvalKits as application setup. Figure 41: Class 1 laser product © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 50 | 53

8 Additional material

Additional material related to the BMV080 includes the following design files and software packages: Sensor integration 3D CAD file of BMV080: BST-BMV080-CAD.stp Sensor software BMV080 Software Development Kit (including support for the BMV080 Shuttle Board 3.1 and Bosch Sensortec Application Board 3.1) : BST-BMV080-SDK © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 51 | 53

9 Legal disclaimer

9.1 Engineering samples

Engineering Samples are marked with an asterisk (*), (E) or (e). Samples may vary from the valid technical specifications of the product series contained in this data sheet. They are therefore not intended or fit for resale to third parties or for use in end products. Their sole purpose is internal client testing. The testing of an engineering sample may in no way replace the testing of a product series. Bosch Sensortec assumes no liability for the use of engineering samples. The Purchaser shall indemnify Bosch Sensortec from all claims arising from the use of engineering samples.

9.2 Product use

Bosch Sensortec products are developed for the consumer goods industry. They may only be used within the parameters of this product data sheet. They are not fit for use in life-sustaining or safety-critical systems. Safety-critical systems are those for which a malfunction is expected to lead to bodily harm, death or severe property damage. In addition, they shall not be used directly or indirectly for military purposes (including but not limited to nuclear, chemical or biological proliferation of weapons or development of missile technology), nuclear power, deep sea or air or space applications (including but not limited to satellite technology) or supercomputers. If customers would like to use Bosch Sensortec products in supercomputers, customers are obligated to get written permissions from Bosch Sensortec. Bosch Sensortec products are released on the basis of the legal and normative requirements relevant to the Bosch Sensortec product for use in the following geographical target market: BE, BG, DK, DE, EE, FI, FR, GR, IE, IT, HR, LV, LT, LU, MT, NL, AT, PL, PT, RO, SE, SK, SI, ES, CZ, HU, CY, US, CN, JP, KR, TW. If you need further information or have further requirements, please contact your local sales contact. The resale and/or use of Bosch Sensortec products are at the purchaser’s own risk and his own responsibility. The examination of fitness for the intended use is the sole responsibility of the purchaser. The purchaser shall indemnify Bosch Sensortec from all third party claims arising from any product use not covered by the parameters of this product data sheet or not approved by Bosch Sensortec and reimburse Bosch Sensortec for all costs in connection with such claims. The purchaser accepts the responsibility to monitor the market for the purchased products, particularly with regard to product safety, and to inform Bosch Sensortec without delay of all safety-critical incidents.

9.3 Application examples and hints

With respect to any examples or hints given herein, any typical values stated herein and/or any information regarding the application of the device, Bosch Sensortec hereby disclaims any and all warranties and liabilities of any kind, including without limitation warranties of non-infringement of intellectual property rights or copyrights of any third party. The information given in this document shall in no event be regarded as a guarantee of conditions or characteristics. They are provided for illustrative purposes only and no evaluation regarding infringement of intellectual property rights or copyrights or regarding functionality, performance or error has been made. © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

Bosch Sensortec | BMV080 Ultra-mini Particulate Matter Sensor – Datasheet 52 | 53

10 Document history and modifications

Rev. No. Chapter Description of modification/changes Date 1.0 all Initial release. Aug 2024 1.1 2.2 Updated technical specifications and lifetime. Dec 2024

3.2 Comparison of pin numbering schemes for BMV080 and ZIF connectors

added. 4.4.1.2 Proposal for filtering signal errors added. 4.4.2.4 Corrected image for complete I²C write. 5.1 Host requirements updated. 5.2 PM1 definition added. 6 Updated content of DMC and laser marking. 7.2 Updated information on laser class compliance. 1.2 1.1 Update with PM10 and PM1. Jan 25 5.1 Updated host requirements. 5.2.1.3 PM10 mass concentration definition added; PM2.5, PM1, PM10 number concentration definition added.

5.2.6 Update on error logging, meta data logging and PM logging in get and

set parameter definition. 1.3 all Editorial work. May 2025 2.1 Reference to Technical Specification Statement added. 2.2 Updated information on measurement algorithms. Recommendation for integration and use-case specific qualification by customer. Reference to Integration Guideline added. 2.3 Update on storage conditions. 3.1 LGA package height corrected. 3.2 Information added about min. bending radius and max. bending angles of Flex PCB. Bending area defined in drawing. 4.1.3.1 Update of mounting and assembly instruction: sealing of cavity added. 4.4.1.4.1 4.4.1.4.2 4.4.1.4.3 Update of figures, ground on pins VSSA, VSSD added. 4.4.2.1 Table for interface selection removed. 4.4.2.4 Section about I²C date write removed. 5.1 Host requirements for ARM Cortex-M7F added. 5.2.1.3 Correction of unit of PM particle concentration.

8 Information on BMV080 EvalKit removed, Update on Sensor Software

Development Kit. © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights Document number: BST-BMV080-DS000-11

72770 Reutlingen / Germany

contact@bosch-sensortec.com www.bosch-sensortec.com Modifications reserved Document number: BST-BMV080-DS000-11