BML095Y BALLUFF | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

Magnetically Coded Sensors BML SF2-I211-GZZZ-ZZZ5-KA05 Order Code: BML095Y Internet www.balluff.com eCl@ss 9.1: 27-27-07-05 Subject to change without notice: 279060 ETIM 6.0: EC002544 BML095Y_0.46_2021-10-13 1) not included in scope of delivery, 2) Distance to tape, 3) Tape, 4) Cable length, 5) Active measurement surface, 6) LED function indicator Basic features Additional features 01 Reference signal, individually or fixed-periodic Additional features 02 Function indicator: LED red/green Additional features 03 Real-time capable Application linear/rotary motion Approval/Conformity TÜV CE cURus EAC WEEE Measuring principle incremental measuring system Series SF2 Display/Operation Function indicator Green LED LED red Electrical connection Bending radius min., fixed cable 7.5 x D Bending radius min., flexible cable 15 x D Cable length L 5 m, Drag chain compatible Conductor cross-section 0.08 mm² Connection Cable, 5 m, PUR Connection type Cable, 5 m, PUR Connection version axial Number of conductors 12 Polarity reversal protected yes Protection against device mix-ups yes Electrical data Current consumption max. at 5 V DC 50 mA Hysteresis H max. 4 µm Overvoltage protection no Periods 2 mm Voltage-proof up to (GND to housing) 500 V DC

Magnetically Coded Sensors BML SF2-I211-GZZZ-ZZZ5-KA05 Order Code: BML095Y Internet www.balluff.com eCl@ss 9.1: 27-27-07-05 Subject to change without notice: 279060 ETIM 6.0: EC002544 BML095Y_0.46_2021-10-13 Environmental conditions Altitude max. 2000 m Ambient temperature -20...80 °C Cable temperature, drag chain -25...85 °C Cable temperature, fixed routing -40...85 °C Cable temperature, flexible routing -25...85 °C EN 55016-2-3, Radiation Industrial areas EN 60068-2-27, Continuous shock 100 g, 2 ms EN 60068-2-27, Shock 100 g, 6 ms EN 60068-2-6, Vibration 12 g, 10…2000 Hz EN 61000-4-2, ESD Severity Level 4 EN 61000-4-3, RFI Severity Level 3 EN 61000-4-4, Burst Severity Level 4 EN 61000-4-5, Surge Severity Level 2 EN 61000-4-6, High-frequency fields Severity Level 3 EN 61000-4-8 Magnetic fields Severity Level 4 Ext. magnetic fields max., in operation 1 mT (no effect) IP rating IP67 Overall system temperature coefficient 10.5 ppm/K Relative humidity ≤ 90 %, non-condensing Storage temperature -30...85 °C Functional safety MTTFd 532 a Mission Time 20 a PFHd (EN 62061) 3 E-9 1/h Performance Level d SIL (IEC 61508) 2 SIL CL (EN 62061) 2 Safety category (EN ISO 13849-1) 3 Type of the subsystem (EN/IEC 61508-2) B Interface Differential signals yes Error signal no Interface Analog Sin/Cos (1 Vpp) Reference signal Individually or fixed-periodic Signal sequence A before B = rising Material Cable flame-resistant UL94 V0 and IEC 60332/2 Housing material Aluminum Material jacket PUR Mechanical data Dimension 12 x 13.1 x 35 mm Lateral offset (Y) ±0.5 mm Mounting part M4 thread Pitch max. ±1.0 ° Pole width 2 mm Procedure direction Lengthwise to tape Roll max. ±1.0 ° Weight 17 g (excluding cable) Yaw max. ± 1.0 ° Range/Distance Non-linearity of sensor head, max. ±4 µm Optimal read distance 0.2 mm Repeat accuracy ≤ 1 µm depending on controller Resolution (controller-dependent) Traverse speed max. 10 m/s Wiring Diagrams