Features

 Piezo-resistive pressure sensor  Pressure range is from 300hPa to 1300hPa  Built-in temperature compensation function.  I2C bus interface (f/s mode support)  Built-in FIFO  Small package

Applications

 Smartphone, Healthcare, mobile device (e.g. game). Key Specifications  Pressure Range: 300hPa to 1300hPa  Relative Pressure Accuracy: ±0.12hPa(Typ)  Absolute Pressure Accuracy: ±1hPa(Typ)  Operating Temperature Range: -40°C to +85°C Package W(Typ) x D(Typ) x H(Max) CLGA10V020A 2.0mm x 2.0mm x 1.0mm Typical Application Circuit ADC Temperature Sensor Mux signal processing I2C SCL SDA TEST2 TEST3 Pressure Sensor Memory Clock VSS VDD VREG HOST BM1386GLV DRI TEST1 TEST0 Regulator (internal) Datasheet

TSZ02201-0M1M0FZ17010-1-2 © 2017 ROHM Co., Ltd. All rights reserved. 14.Nov.2017 Rev.002 www.rohm.co.jp TSZ22111 • 15 • 001 BM1386GLV

Contents

TSZ02201-0M1M0FZ17010-1-2 © 2017 ROHM Co., Ltd. All rights reserved. 14.Nov.2017 Rev.002 www.rohm.co.jp TSZ22111 • 15 • 001 BM1386GLV Pin Configuration 6 7 VREGSCL TEST3 DRI TEST1 VSS VDD TEST0 SDA TEST2 Pin Description Pin No. Pin Name Function

1 VREG Internal power supply pin(Note 1)

2 SCL I2C serial bus colck pin

3 TEST0 Test pin (connect to VSS)

4 SDA I2C serial bus data pin

5 TEST2 Test pin (open)

6 TEST3 Test pin (connect to VDD)

7 DRI Interrupt notice output pin

8 TEST1 Test pin (connect to VSS)

9 VSS Ground pin

10 VDD power voltage pin(Note 2)

(Note 1) Dispose a bypass capacitor as close as possible to the IC. Please set a bypass capacitor of 0.22µF between DREG and VSS. Please do not use this pin for external power source. (Note 2) Dispose a bypass capacitor as close as possible to the IC. Top View (pads not visible)

TSZ02201-0M1M0FZ17010-1-2 © 2017 ROHM Co., Ltd. All rights reserved. 14.Nov.2017 Rev.002 www.rohm.co.jp TSZ22111 • 15 • 001 BM1386GLV Block Diagram ADC Temperature Sensor Mux signal processing I2C SCL SDA TEST2 TEST3 Pressure Sensor Memory Clock VSS VDD VREGBM1386GLV DRI TEST1 TEST0 Regulator (internal)

TSZ02201-0M1M0FZ17010-1-2 © 2017 ROHM Co., Ltd. All rights reserved. 14.Nov.2017 Rev.002 www.rohm.co.jp TSZ22111 • 15 • 001 BM1386GLV Absolute Maximum Ratings (Ta = 25°C) Parameter Symbol Rating Unit Power Supply VDD_MR 4.5 V Input Voltage1(Note 1) VIN1MR -0.3 to +4.5 V Input Voltage2(Note 2) VIN2MR -0.3 to (VDD+0.3) or +4.5 whichever is less V Storage Temperature Tstg -40 to +125 °C Maximum Junction Temperature Tjmax 125 °C Pressure Povr 20000 hPa (Note 1) DRI, SCL, SDA pin (Note 2) except DRI, SCL, SDA pin Caution 1: Operating the IC over the absolute maximum ratings may damage the IC. The damage can either be a short circuit between pins o r an open circuit between pins and the internal circuitry. Therefore, it is import ant to consider circuit protection measures, such as adding a fuse, in case the IC is operated over the absolute maximum ratings. Caution 2: Should by any chance the maximum junction temperature rating be exceeded the rise in temperature of the chip may re sult in deterioration of the properties of the chip. In case of exceeding this absolute maximum rating, increase the board size and copper area to prevent exceeding the maximum junction temperature rating. Thermal Resistance(Note 1) Parameter Symbol Thermal Resistance (Typ) Unit 1s(Note 3) 2s2p(Note 4) CLGA10V020A Junction to Ambient θJA 339.7 217.5 °C/W Junction to Top Characterization Parameter(Note 2) ΨJT 154 140 °C/W (Note 1)Based on JESD51-2A(Still-Air) (Note 2)The thermal characterization pa rameter to report the difference between junction temperature and the temperature at the top center of the outside surface of the component package. (Note 3)Using a PCB board based on JESD51-3. Layer Number of Measurement Board Material Board Size Single FR-4 114.3mm x 76.2mm x 1.57mmt Top Copper Pattern Thickness Footprints and Traces 70μm (Note 4)Using a PCB board based on JESD51-7. Layer Number of Measurement Board Material Board Size 4 Layers FR-4 114.3mm x 76.2mm x 1.6mmt Top 2 Internal Layers Bottom Copper Pattern Thickness Copper Pattern Thickness Copper Pattern Thickness Footprints and Traces 70μm 74.2mm x 74.2mm 35μm 74.2mm x 74.2mm 70μm Recommended Operating Conditions Parameter Symbol Min Typ Max Unit Power Supply VDD 1.7 1.8 3.6 V Input Voltage1(Note 1) VIN1 0.0 - 3.6 V I2C clock Input Frequency fSCL - - 400 kHz Operating Temperature Topr -40 +25 +85 °C (Note 1) DRI, SCL, SDA pin

TSZ02201-0M1M0FZ17010-1-2 © 2017 ROHM Co., Ltd. All rights reserved. 14.Nov.2017 Rev.002 www.rohm.co.jp TSZ22111 • 15 • 001 BM1386GLV Electrical Characteristics (Unless otherwise specified VDD=1.8V Ta=25°C) Parameter Symbol Min Typ Max Unit Conditions Current Consumption Power Down Mode Current ISS - 1 5 µA PWR_DOWN=0, RSTB=0 Logic L Input Voltage(Note 1) VIL - - 0.3 * VDD V H Input Voltage(Note 1) VIH 0.7 * VDD - - V L Input Current(Note 1) IIL -10 - - μA VIL = GND H Input Current(Note 1) IIH - - 10 μA VIH = VDD L Output Voltage 1(Note 2) VOL1 - - 0.2 * VDD V IL = -0.3mA L Output Voltage 2(Note 3) VOL2 - - 0.2 * VDD V IL = -3mA Pressure characteristics Pressure Detection Range PR 300 - 1300 hPa 0°C to 65°C Relative Pressure Accuracy(Note 4) Prel - ±0.12 - hPa 950hPa to 1050hPa Absolute Pressure Accuracy Pabs - ±1 - hPa 1000hPa Temperature Accuracy Tabs - ±2 - °C 25°C to 85°C Measurement Time(Note 5) Tm - - 6 msec AVE_NUM=000 (Note 1) SDA, SCL pin (Note 2) DRI pin (Note 3) SDA pin (Note 4) Target values (Note 5) Measurement time is changed by average number of measurement data. It is written in Measurement time more detail.

TSZ02201-0M1M0FZ17010-1-2 © 2017 ROHM Co., Ltd. All rights reserved. 14.Nov.2017 Rev.002 www.rohm.co.jp TSZ22111 • 15 • 001 BM1386GLV I2C Bus Timing Characteristics (Unless otherwise specified VDD=1.8V, Ta=25°C) Parameter Symbol Min Typ Max Unit Conditions SCL Clock frequency fSCL 0 - 400 kHz ‘L’ Period of the SCL Clock tLOW 1.3 - - µs ‘H’ Period of the SCL Clock tHIGH 0.6 - - µs Setup Time for Repeated START tSU;STA 0.6 - - µs Hold Time for START tHD;STA 0.6 - - µs Data Setup Time tSU;DAT 100 - - ns Data Hold Time tHD;DAT 0 - - µs Setup Time for STOP tSU;STO 0.6 - - µs Bus Free Time between STOP and START tBUF 1.3 - - µs I2C Bus Communication 1. Write Format (1) Indicate register address S Slave Address W

0 ACK Register Address ACK P

(2) Write data after indicating register address S Slave Address W

0 ACK Register Address ACK

Data specified at register address field ACK ・・・ ACK Data specified at register address field + N ACK P 2. Read Format (1) Read data after indicating register address S Slave Address W

1 ACK Data specified at register

Data specified at register address field + 1 ACK ・・・ ACK Data specified at register address field + N NACK P (2) Read data from the specified register S Slave Address R Data specified at register address field + 1 ACK ・・・ ACK Data specified at register address field + N NACK P from master to slave from slave to master SDA SCL tHD;STA tLOW tHD;DAT tSU;DAT tHIGH tSU;STA tHD;STA tSU;STO tBUF VIL VIL VIL VIH VIH VIL VIH VIH VIH VIH VIH VIH VIH VIL VIL VIL VIH S : START S : START P : STOP S : Repeated START

TSZ02201-0M1M0FZ17010-1-2 © 2017 ROHM Co., Ltd. All rights reserved. 14.Nov.2017 Rev.002 www.rohm.co.jp TSZ22111 • 15 • 001 BM1386GLV I2C bus Slave Address The slave address is “1011101”. Register Map(Note 1) (Note 1)Do not write any commands to other addresses except above. Do not write ‘1’ to the fields in which value is ‘0’ in above table. Address from 0x14 to 0x1E registers can be accessed only when PWR_DOWN=1 and RSTB=1. (In other case Write: Ignored, Read: 0xXX) Register Address Register Name R/W D7 D6 D5 D4 D3 D2 D1 D0 0x0F MANUFACTURER ID R MANUFACTURER ID [7:0] 0x10 PART ID R PART ID [7:0] 0x12 POWER_DOWN RW 0 0 0 0 0 0 0 PWR_ DOWN 0x13 RESET RW 0 0 0 0 0 0 0 RSTB 0x14 MODE_CONTROL RW AVE_NUM[2:0] DR_EN FULL _EN WTM _EN MODE[1:0] 0x15 IIR, FIFO CONTROL RW FIFO_ EN WTM_ LEVEL 0 0 0 0 IIR_MODE[1:0] 0x18 FIFO data R 0 0 FIFO_LEV[5:0] 0x19 STATUS R 0 0 0 0 0 RD_ FULL RD_ WTM RD_ DRDY 0x1A PRESSURE R PRESS_OUT[15:8] 0x1B R PRESS_OUT[7:0] 0x1C R PRESS_OUT_XL[5:0] 0 0 0x1D TEMPERATURE R TEMP_OUT[15:8] 0x1E R TEMP_OUT[7:0]

TSZ02201-0M1M0FZ17010-1-2 © 2017 ROHM Co., Ltd. All rights reserved. 14.Nov.2017 Rev.002 www.rohm.co.jp TSZ22111 • 15 • 001 BM1386GLV ( 0x0F ) MANUFACTURER ID Fields Function MANUFACTURER ID [7:0] Manufacturer ID : 0xE0 ( 0x10 ) PART ID Fields Function PART ID [7:0] Part ID : 0x33 ( 0x12 ) POWER_DOWN Fields Function PWR_DOWN 0: power down 1: active default value 0x00 ( 0x13 ) RESET Fields Function RSTB 0: Measurement control block is reset 1: Measurement control block is active default value 0x00

TSZ02201-0M1M0FZ17010-1-2 © 2017 ROHM Co., Ltd. All rights reserved. 14.Nov.2017 Rev.002 www.rohm.co.jp TSZ22111 • 15 • 001 BM1386GLV ( 0x14 ) MODE_CONTROL Fields Function AVE_NUM[2:0] Seting of the averaging number of measurement data 000: single, 001: 2 times, 010: 4 times, 011: 8 times, 100: 16 times, 101: 32 times, 110: 64 times, 111: Prohibited DR_EN DRI pin Enable for Data Ready Details are written in Interrupt. 0 : DRI pin Disable, 1 : DRI pin Enable FULL_EN DRI pin Enable for FULL Details are written in Interrupt. 0 : DRI pin Disable, 1 : DRI pin Enable WTM_EN DRI pin Enable for Water Mark Details are written in Interrupt. 0 : DRI pin Disable, 1 : DRI pin Enable MODE[1:0] Measurement mode setting (Pressure and Temperature are measured at one rate) 00 : Stand by, 01 : One shot, 10 : Continuous, 11 : Prohibited default value 0x00 Measurement time and RMS noise against number of average AVE_NUM Measurement time Tm max[ms] Measurement cycle Ti max[ms] RMS noise [hPa] 000 6 60 0.090 001 9 60 0.063 010 16 60 0.045 011 30 60 0.032 100 60 60 0.023 101 120 120 0.016 110 240 240 0.011 RMS noise is calculated as standard deviation of 32 data points (1σ). RMS noise is a reference value and it’s not the value with guarantee. Condition VDD=1.8V, Ta=25°C, IIR_MODE=00 Measurement time One shot mode perform one measurement. Measurement data is updated when measurement completed, so it should be read more than Tm after measurement start. Continuous mode repeat measurement in every measurement cycle T i. The latest measurement data which is completed is read. Measurement time Tm and measurement cycle Ti is determined by number of average. <One shot mode> <Continuous mode> First Measurement Measurement time Tm Measurement cycle Ti Second measurement Start of measurement Measurement time Tm Start of measurement Start of measurement Measurement Measurement Pressure data of first time measurement is read.

TSZ02201-0M1M0FZ17010-1-2 © 2017 ROHM Co., Ltd. All rights reserved. 14.Nov.2017 Rev.002 www.rohm.co.jp TSZ22111 • 15 • 001 BM1386GLV Operation mode transition Please refer to the below figure of operation mode transition. Power down mode is the smallest current consumption mode due to circuit is OFF. Please set this mode when reducing current consumption. Measurement is not available in this mode, so the measurement is performed after switching to standby mode. In reset mode, regulator for internal blocks is active and measurement control block is reset. Register is initialized in Reset mode. Measurement command is acceptable when “1” is written in “RSTB” There are 2 measurement modes. One shot mode and Continuous mode. They are transferred from stand by mode. Then, please set “AVE_NUM” register at the same time. Please write “0x1400” when transferring to standby mode again. In one shot mode, a single measurement is performed when “01” is written in “MODE”. After the measurement completes, it is transferred to standby mode automatically. When “0x1400” is written before end of measurement, mode is switched to standby immediately but pressure value is not updated. Transition to the other measurement mode during measurement in one shot mode is forbidden. In Continuous mode, when “10” is written in “MODE”, measurement starts and it continues until “0x1400” is written. Transition to the other measurement mode from Continuous mode is forbidden. 0x14X1 After measurement time Tm or 0x1400 0x14X2 0x1400 One Shot Continuous Stand by Reset 0x1301 0x1300 Power Down 0x1201 0x1200 0x1400 0x14X2 → Prohibited Prohibition Regulator:OFF Processing:OFF Regulator:ON Processing:OFF Regulator:ON Processing:ON 0x14X1 → Prohibited 0xYYZZ (send command) YY:Address ZZ:Data

TSZ02201-0M1M0FZ17010-1-2 © 2017 ROHM Co., Ltd. All rights reserved. 14.Nov.2017 Rev.002 www.rohm.co.jp TSZ22111 • 15 • 001 BM1386GLV ( 0x15 ) IIR, FIFO CONTROL Fields Function FIFO_EN FIFO mode setting Details are written in FIFO. 0: Bypass mode, 1: FIFO mode WTM_LEVEL Water Mark level setting Details are written in FIFO. 0: Water Mark interrupt occur when FIFO memory is 24 or above. 1: Water Mark interrupt occur when FIFO memory is 28 or above. IIR_MODE[1:0] IIR filter enable and coefficient setting 00 : IIR OFF, 01 : IIR ON (weak) 10 : IIR ON (middle), 11 : IIR ON (strong) default value 0x00 ( 0x18 ) FIFO data Fields Function FIFO_LEV[5:0] Number of sample in FIFO default value 0x00 FIFO_LEV[5:0] D5 D4 D3 D2 D1 D0 Description 0 0 0 0 0 0 FIFO empty 0 0 0 0 0 1 Number of sample in FIFO =1 : : : : : : 1 0 0 0 0 0 FIFO FULL ( 0x19 ) STATUS Fields Function RD_FULL FIFO overrun (FULL) status This register is cleared when this is read. RD_FULL is not updated unless data are read. 0: FIFO is not full; 1: FIFO is full. RD_WTM FIFO threshold (Water Mark) status This register is cleared when FIFO memory become less than threshold level. 0: Number of sample in FIFO is lower than threshold level. 1: Number of sample in FIFO is equal or higher than threshold level. RD_DRDY Pressure and temperature measurement data ready bit This register is cleared when ‘1’ is read. Do not care RD_DRDY in FIFO mode (FIFO_EN=1). 0: data is not updated 1: data is updated default value 0x00

TSZ02201-0M1M0FZ17010-1-2 © 2017 ROHM Co., Ltd. All rights reserved. 14.Nov.2017 Rev.002 www.rohm.co.jp TSZ22111 • 15 • 001 BM1386GLV ( 0x1A / 0x1B / 0x1C ) PRESSURE Fields Function PRESS_OUT[15:0] PRESS_OUT_XL[5:0] pressure data default value 0x000000 Conversion to pressure value is below. Pressure counts = PRESS_OUT[15:8] x 214 + PRESS_OUT[7:0] x 26 + PRESS_OUT_XL[5:0] [counts] (dec) Pressure value [hPa] = Pressure counts [counts] / 2048 [counts/hPa] Data registers (0x1A, 0x1B, 0x1C) should be read by burst read. Data is updated at the timing of measurement completion. If they are not read by burst read, data might be mixed up with the data of different measurement. ( 0x1D / 0x1E ) TEMPERATURE Fields Function TEMP_OUT[15:0] temperature data default value 0x0000 Conversion to temperature value is below. Please note that TEMP_OUT is data with sign (two’s complement). Temp counts = TEMP_OUT[15:8] x 28 +TEMP_OUT[7:0] [counts] (dec) Temperature value [°C] = Temp counts [counts] / 32 [counts/°C] (in case of positive number) Data registers (0x1D,0x1E) should be read by burst read. Data is updated at the timing of measurement completion. If they are not read by burst read, data might be mixed up with the data of different measurement.

TSZ02201-0M1M0FZ17010-1-2 © 2017 ROHM Co., Ltd. All rights reserved. 14.Nov.2017 Rev.002 www.rohm.co.jp TSZ22111 • 15 • 001 BM1386GLV FIFO This IC embeds a 32-slot FIFO to store the pressure and temperature output values. FIFO has Bypass mode (FIFO_EN=0) and FIFO mode (FIFO_EN=1). In FIFO mode, the pressure and temperature output values are stored in FIFO when measurement is completed. The data is read from oldest data. Interrupt for WTM and FULL is available in FIFO mode. WTM interrupt is enable when WTM_EN is set to ‘1’. In this mode, when FIFO memory reach the number set in WTM_LEVEL, RD_WTM goes to ‘1’. FULL interrupt is enable when FULL_EN is set to ‘1’. In this mode, when 32 data are stored in FIFO, RD_FULL goes to ‘1’. FIFO_LEV is the number of sample in FIFO. FIFO is only available in Continuous mode. <Bypass mode> FIFO is not operational in Bypass mode (FIFO_EN=0). New data is overwritten to old data due to only the first slot of FIFO is in use. FIFO and FIFO_LEV are initialized in Bypass mode. Pressure data 0 Temerature data 0 Pressure data 1 Temerature data 1 Pressure data 2 Temerature data 2 : : Pressure data 23 Temerature data 23 Pressure data 24 Temerature data 24 : : Pressure data 31 Temerature data 31 FIFO <FIFO mode> FIFO is operational in FIFO mode (FIFO_EN= 1). Pressure data is read from the address 0x1A, 0x1B and 0x1C and temperature data is read from the address 0x1D and 0x1E. The data is read from oldest data. FIFO stops storing data when FIFO is FULL. Pressure data 0 Temerature data 0 Pressure data 1 Temerature data 1 Pressure data 2 Temerature data 2 : : Pressure data 23 Temerature data 23 Pressure data 24 Temerature data 24 : : Pressure data 31 Temerature data 31 FIFO

TSZ02201-0M1M0FZ17010-1-2 © 2017 ROHM Co., Ltd. All rights reserved. 14.Nov.2017 Rev.002 www.rohm.co.jp TSZ22111 • 15 • 001 BM1386GLV Water Mark interrupt Water Mark interrupt occur when stored data in FIFO is equal to or more than the number set in WTM_LEVEL. Water Mark level is selectable from 24 (WTM_LEVEL=0) and 28 (WTM_LEVEL=1). RD_WTM goes to ‘1’ when Water Mark interrupt occur Water Mark interrupt keep active state while FIFO_LEV is equal to or more than WTM_LEVEL. And it i s released, when FIFO_LEV go below WTM_LEVEL. DRI pin status is determined by Water Mark interrupt, when WTM_EN is ‘1’. Case of Water Mark occurs at 24 of Water Mark level Pressure data 0 Temerature data 0 Pressure data 1 Temerature data 1 Pressure data 2 Temerature data 2 : : Pressure data 23 Temerature data 23 Pressure data 24 Temerature data 24 : : Pressure data 31 Temerature data 31 FIFO FULL interrupt FULL interrupt occur when stored data in FIFO is 32. RD_FULL goes ‘1’. RD_FULL goes ‘0’ when RD_FULL is read. FIFO and RD_FULL are not updated by measurement after FULL interrupt occur. Then FIFO_LEV is fixed to 32. DRI pin status is determined by FULL interrupt, when FULL_EN is ‘1’. Case of FULL occurs Pressure data 0 Temerature data 0 Pressure data 1 Temerature data 1 Pressure data 2 Temerature data 2 : : Pressure data 23 Temerature data 23 Pressure data 24 Temerature data 24 : : Pressure data 31 Temerature data 31 FIFO

TSZ02201-0M1M0FZ17010-1-2 © 2017 ROHM Co., Ltd. All rights reserved. 14.Nov.2017 Rev.002 www.rohm.co.jp TSZ22111 • 15 • 001 BM1386GLV Interrupt function Interrupt factor is Data Ready, FIFO FULL and FIFO WTM. The condition is listed below. The status register is always operational. The status register goes ‘1’ when interrupt occur. When the DRI pin enable register for each factor is ‘1’, DRI pin status is determined by the interrupt state of factor. When interrupt occur, DRI pin output ‘L’. The status register and DRI pin keeps the state until the interrupt is cleared. FIFO FULL and FIFO WTM are not available in Bypass mode (FIFO_EN=0) Do not care Data Ready in FIFO mode (FIFO_EN=1). Interrupt factor Factor Status register Interrupt condition Interrupt Clear condition Data Ready RD_DRDY Measurement completion Read RD_RDRY FIFO FULL RD_FULL FIFO is Full Read RD_FULL FIFO WTM RD_WTM FIFO_LEV≧WTM level FIFO_LEV<WTM level Relation between factor and DRI pin enable Factor DRI pin enable Data Ready DR_EN FIFO FULL FULL_EN FIFO WTM WTM_EN DRI pin is Nch open drain so this terminal should be pull-up to voltage source by an external resister. DRI pin is high impedance just after VDD is supplied. DRI pin becomes inactive (High impedance) by reading RD_DRDY register or setting reset mode. VDD current (approximately 6µA at VDD=1.8V) is consumed during DRI is active. When disabling interrupt function, please disable after clearing interrupt. <Example of Data Ready interrupt :1shot mode> Stand by One shot High Low DRI pin Stand by data is ready Read 0x19 One shot Stand by One shot Stand by Read 0x19 Operation mode data is ready data is ready Write MODE=01 Write MODE=01 Write MODE=01

TSZ02201-0M1M0FZ17010-1-2 © 2017 ROHM Co., Ltd. All rights reserved. 14.Nov.2017 Rev.002 www.rohm.com TSZ22111 • 15 • 001 BM1386GLV Control sequence 1. Power-on sequence Parameter Symbol Min Typ Max Unit Conditions Command input time after power-on tPSC 100 - - µs Reset cancel wait time tSC1 1 - - ms VREG:0.22µF tPSC after VDD power-on, command can be input. Please send reset cancel command (RSTB=1) more than tsc1 after regulator for internal blocks become active (PWR_DOWN=1) 2. Power-off sequence Parameter Symbol Min Typ Max Unit Conditions Wait time from power down command tCPS 0 - - µs Power supply OFF time tPSL 1 - - ms Please send reset command (RSTB=0) to turn regulator for internal blocks off (PWR_DOWN=0) tCPS before the VDD power-off. Please keep VDD Low (VDD<0.4V) more than tPSL before VDD power-on tLOW tHD;DAT tHIGH tSU;STA 0.4V VDD tPSC Command Acceptable VDD(Min) 0.4V tPSL 0.4V VDD(Min) tCPS I2C Command POWER_DOWN 0x1201 Command RESET 0x1301 tSC1 tLOW tHD;DAT tHIGH tSU;STA Command POWER_DOWN 0x1200 VDD I2C Command RESET 0x1300

TSZ02201-0M1M0FZ17010-1-2 © 2017 ROHM Co., Ltd. All rights reserved. 14.Nov.2017 Rev.002 www.rohm.com TSZ22111 • 15 • 001 BM1386GLV 3. Starting sequence 4. Measurement sequence: One Shot Mode Starting sequence MODE_CONTROL setting Write : 0x14XX (DR_EN=1, MODE=01) DRI terminal L H read PRESSURE Read : 0x1A to 0x1C(Note 1) Measurement complestion measurement mode setting. it starts temperature and pressure measurement.: wait interrupt(DRI='L') or measurement end: Enable DRI? noyes MODE_CONTROL setting Write : 0x14XX (DR_EN=0, MODE=01) wait for the end of measurement no yes read STATUS Read : 0x19 check interrupt status DRI terminal is set to 'H' by reading.: (Note 1) Data registers (0x1A, 0x1B, 0x1C) should be read by burst read. power supply POWER_DOWN setting Write : 0x1201 RESET setting Write : 0x1301 Completion of starting sequence release Power down release Reset mode wait for more than 1ms wait for more than 0.1ms Completion of operation preparation:

TSZ02201-0M1M0FZ17010-1-2 © 2017 ROHM Co., Ltd. All rights reserved. 14.Nov.2017 Rev.002 www.rohm.com TSZ22111 • 15 • 001 BM1386GLV 5. Measurement sequence: Continuous Mode (50ms/100ms/200ms) (Note 1) Data registers (0x1A, 0x1B, 0x1C) should be read by burst read. Starting sequence DRI terminal L H read PRESSURE Read : 0x1A to 0x1C(Note 1) Measurement complestion measurement mode setting. it starts temperature and pressure measurement.: wait interrupt(DRI='L') or measurement end: read Pressure data: Enable DRI? noyes wait for the end of measurement no yes read STATUS Read : 0x19 : MODE_CONTROL setting Write : 0x1400 shift to Stand-by mode. At the timing of setting the command it stops measurement and shifts to Stand-by mode. yes no measurement stop? Enable DRI? noyes end judgement of Continuous mode: check interrupt status DRI terminal is set to 'H' by reading. MODE_CONTROL setting Write : 0x14XX (DR_EN=1,MODE=10) MODE_CONTROL setting Write : 0x14XX (DR_EN=0,MODE=10)

TSZ02201-0M1M0FZ17010-1-2 © 2017 ROHM Co., Ltd. All rights reserved. 14.Nov.2017 Rev.002 www.rohm.com TSZ22111 • 15 • 001 BM1386GLV 6. Measurement sequence: Use case of FIFO (Note 1) Data registers (0x1A, 0x1B, 0x1C, 0x1D, 0x1E) should be read by burst read. (Note 2) During a period form a start of FIFO reading (write to address 0x1A) to FIFO_LEV reading (write to address 0x18), do not comm unicate with this device. When communicating with this device during FIFO reading, read FIFO_LEV and finish FIFO read sequence before other communication. If don't read FIFO_LEV before other communication, there is a possibility to lose FIFO data. Starting sequence DRI terminalH Measurement complestion measurement mode setting. it starts temperature and pressure measurement.: wait interrupt(DRI='L') or certain time: Enable DRI? noyes wait for certain time no read data Read : 0x1A to 0x1E(Note 1) : MODE_CONTROL setting Write : 0x1400 : yes no measurement stop? Enable DRI? noyes end judgement of Continuous mode: read measurement data MODE_CONTROL setting Write : 0x14XX (WTM_EN=1,MODE=10) MODE_CONTROL setting Write : 0x14XX (WTM_EN=0,MODE=10) FIFO setting Write : 0x15XX (FIFO_EN=1) yesL read FIFO_LEV Read : 0x18 read stop? no yes check number of sample in FIFO: (Note 2) shift to Stand-by mode. At the timing of setting the command it stops measurement and shifts to Stand-by mode.

TSZ02201-0M1M0FZ17010-1-2 © 2017 ROHM Co., Ltd. All rights reserved. 14.Nov.2017 Rev.002 www.rohm.com TSZ22111 • 15 • 001 BM1386GLV 7. Ending sequence Measurement complestion RESET setting Write : 0x1300 POWER_DOWN setting Write : 0x1200 VDD OFF Reset: power down:

TSZ02201-0M1M0FZ17010-1-2 © 2017 ROHM Co., Ltd. All rights reserved. 14.Nov.2017 Rev.002 www.rohm.com TSZ22111 • 15 • 001 BM1386GLV Application Example ADC Temperature Sensor Mux signal processing I2C SCL SDA TEST2 TEST3 Pressure Sensor Memory Clock VSS VDD VREG BM1386GLV DRI TEST1 TEST0 Regulator (internal) 0.22µF 0.1µF

TSZ02201-0M1M0FZ17010-1-2 © 2017 ROHM Co., Ltd. All rights reserved. 14.Nov.2017 Rev.002 www.rohm.com TSZ22111 • 15 • 001 BM1386GLV I/O Equivalent Circuits Pin Name Equivalent Circuit Pin Name Equivalent Circuit SCL SDA TEST3 VREG TEST2 TEST0 TEST1 DRI VDD VDD VDD VDD VDD VDD VDD VDD VDD VDD VDD

TSZ02201-0M1M0FZ17010-1-2 © 2017 ROHM Co., Ltd. All rights reserved. 14.Nov.2017 Rev.002 www.rohm.com TSZ22111 • 15 • 001 BM1386GLV Operational Notes 1. Reverse Connection of Power Supply Connecting the power supply in reverse polarity can damage the IC. Take precautions against reverse polarity when connecting the power supply , such as mounting an external diode between the power supply and the IC ’s power supply pins. 2. Power Supply Lines Design the PCB layout pattern to provide low impedance supply lines. Furthermore, connect a capacitor to ground at all power supply pins. Consider the effect of temperature and aging on the capacitance value when using electrolytic capacitors. 3. Ground Voltage Ensure that no pins are at a voltage below that of the ground pin at any time, even during transient condition. 4. Ground Wiring Pattern When using both small-signal and large-current ground traces, the two ground traces should be routed separately but connected to a single ground at the reference point of the application board to avoid fluctuations in the small -signal ground caused by large currents. Also ensure that the ground traces of external components do not cause variations on the ground voltage. The ground lines must be as short and thick as possible to reduce line impedance. 5. Recommended Operating Conditions The function and operation of the IC are guaranteed within the range specified by the recommended operating conditions. The characteristic values are guaranteed only under the conditions of each item specified by the electrical characteristics. 6. Inrush Current When power is first supplied to the IC, it is possible that the internal logic may be unstable and inrush current may flow instantaneously due to the internal powering sequence and delays, especially if the IC has more than one power supply. Therefore, give special consideration to power coupling capacitance, power wiring, width of ground wiring, and routing of connections. 7. Operation Under Strong Electromagnetic Field Operating the IC in the presence of a strong electromagnetic field may cause the IC to malfunction. 8. Testing on Application Boards When testing the IC on an application board, connecting a capacitor dir ectly to a low -impedance output pin may subject the IC to stress. Always discharge capacitors completely after each process or step. The IC’s power supply should always be turned off completely before connecting or removing it from the test setup during th e inspection process. To prevent damage from static discharge, ground the IC during assembly and use similar precautions during transport and storage. 9. Inter-pin Short and Mounting Errors Ensure that the direction and position are correct when mounting the IC on the PCB. Incorrect mounting may result in damaging the IC. Avoid nearby pins being shorted to each other especially to ground , power supply and output pin . Inter-pin shorts could be due to many reasons such as metal particles, water droplets (in ver y humid environment) and unintentional solder bridge deposited in between pins during assembly to name a few. 10. Unused Input Pins Input pins of an IC are often connected to the gate of a MOS transistor. The gate has extremely high impedance and extremely lo w capacitance. If left unconnected, the electric field from the outside can easily charge it. The small charge acquired in this way is enough to produce a significant effect on the conduction through the transistor and cause unexpected operation of the IC. So unless otherwise specified, unused input pins should be connected to the power supply or ground line.

TSZ02201-0M1M0FZ17010-1-2 © 2017 ROHM Co., Ltd. All rights reserved. 14.Nov.2017 Rev.002 www.rohm.com TSZ22111 • 15 • 001 BM1386GLV Operational Notes – continued 11. Regarding the Input Pin of the IC In the construction of this IC, P -N junctions are inevitably formed creating parasit ic diodes or transistors. The operation of these parasitic elements can result in mutual interference among circuits, operational faults, or physical damage. Therefore, conditions which cause these parasitic elements to operate, such as applying a voltage to an input pin lower than the ground voltage should be avoided. Furthermore, do not apply a voltage to the input pins when no power supply voltage is applied to the IC. Ev en if the power supply voltage is applied, make sure that the input pins have voltages within the values specified in the electrical characteristics of this IC. 12. Ceramic Capacitor When using a ceramic capacitor, determine the dielectric constant considerin g the change of capacitance with temperature and the decrease in nominal capacitance due to DC bias and others. 13. Disturbance light In a device where a portion of silicon is exposed to light such as in a WL-CSP , IC characteristics may be affected due to photoelectric effect. For this reason, it is recommended to come up with countermeasures that will prevent the chip from being exposed to light.

TSZ02201-0M1M0FZ17010-1-2 © 2017 ROHM Co., Ltd. All rights reserved. 14.Nov.2017 Rev.002 www.rohm.com TSZ22111 • 15 • 001 BM1386GLV

Ordering Information

GLV: CLGA10V020A Packaging and forming specification TR: Embossed tape and reel Marking Diagrams CLGA10V020A (TOP VIEW) LOT Number 1PIN MARK Part Number Marking

TSZ02201-0M1M0FZ17010-1-2 © 2017 ROHM Co., Ltd. All rights reserved. 14.Nov.2017 Rev.002 www.rohm.com TSZ22111 • 15 • 001 BM1386GLV Physical Dimension, Tape and Reel Information

TSZ02201-0M1M0FZ17010-1-2 © 2017 ROHM Co., Ltd. All rights reserved. 14.Nov.2017 Rev.002 www.rohm.com TSZ22111 • 15 • 001 BM1386GLV

Revision History

18.Aug.2017 001 New Release 14.Nov.2017 002 P7,10, 14,15 and 16 Correction of errors P19 Modify Measurement sequence: One Shot Mode, Correction of errors P20 Modify Measurement sequence: Continuous Mode, Correction of errors P21 Add Measurement sequence: Use case of FIFO, Correction of errors

Notice-PGA-E Rev.003 © 2015 ROHM Co., Ltd. All rights reserved. Notice Precaution on using ROHM Products 1. Our Products are designed and manufactured for application in ordinary electronic equipment (such as AV equipment, OA equipment, telecommunication equipment, home electronic appliances, amusement equipment, etc.). If you intend to use our Products in devices requiring extremely high reliability (such as medical equipment (Note 1), transport equipment, traffic equipment, aircraft/spacecraft, nuclear power controllers, fuel controllers, car equipment including car accessories, safety devices, etc.) and whose malfunction or failure may cause loss of human life, bodily injury or serious damage to property ( “Specific Applications”), please consult with the ROHM sales representative in advance. Unless otherwise agreed in writing by ROHM in advance, ROHM shall not be in any way responsible or liable for any damages, expenses or losses incurred by you or third parties arising from the use of any ROHM’s Products for Specific Applications. (Note1) Medical Equipment Classification of the Specific Applications JAPAN USA EU CHINA CLASSⅢ CLASSⅢ CLASSⅡb CLASSⅢ CLASSⅣ CLASSⅢ 2. ROHM designs and manufactures its Products subject to strict quality control system. However, semiconductor products can fail or malfunction at a certain rate. Please be sure to implement, at your own responsibilities, adequate safety measures including but not limited to fail-safe design against the physical injury, damage to any property, which a failure or malfunction of our Products may cause. The following are examples of safety measures: [a] Installation of protection circuits or other protective devices to improve system safety [b] Installation of redundant circuits to reduce the impact of single or multiple circuit failure 3. Our Products are designed and manufactured for use under standard conditions and not under any special or extraordinary environments or conditions, as exemplified below. Accordingly, ROHM shall not be in any way responsible or liable for any damages, expenses or losses arising from the use of any ROHM’s Products under any special or extraordinary environments or conditions. If you intend to use our Products under any special or extraordinary environments or conditions (as exemplified below), your independent verification and confirmation of product performance, reliability, etc, prior to use, must be necessary: [a] Use of our Products in any types of liquid, including water, oils, chemicals, and organic solvents [b] Use of our Products outdoors or in places where the Products are exposed to direct sunlight or dust [c] Use of our Products in places where the Products are exposed to sea wind or corrosive gases, including Cl2, H2S, NH3, SO2, and NO2 [d] Use of our Products in places where the Products are exposed to static electricity or electromagnetic waves [e] Use of our Products in proximity to heat-producing components, plastic cords, or other flammable items [f] Sealing or coating our Products with resin or other coating materials [g] Use of our Products without cleaning residue of flux (even if you use no-clean type fluxes, cleaning residue of flux is recommended); or Washing our Products by using water or water-soluble cleaning agents for cleaning residue after soldering [h] Use of the Products in places subject to dew condensation 4. The Products are not subject to radiation-proof design. 5. Please verify and confirm characteristics of the final or mounted products in using the Products. 6. In particular, if a transient load (a large amount of load applied in a short period of time, such as pulse. is applied, confirmation of performance characteristics after on-board mounting is strongly recommended. Avoid applying power exceeding normal rated power; exceeding the power rating under steady-state loading condition may negatively affect product performance and reliability. 7. De-rate Power Dissipation depending on ambient temperature. When used in sealed area, confirm that it is the use in the range that does not exceed the maximum junction temperature. 8. Confirm that operation temperature is within the specified range described in the product specification. 9. ROHM shall not be in any way responsible or liable for failure induced under deviant condition from what is defined in this document. Precaution for Mounting / Circuit board design 1. When a highly active halogenous (chlorine, bromine, etc.) flux is used, the residue of flux may negatively affect product performance and reliability. 2. In principle, the reflow soldering method must be used on a surface-mount products, the flow soldering method must be used on a through hole mount products. I f the flow soldering method is preferred on a surface-mount products , please consult with the ROHM representative in advance. For details, please refer to ROHM Mounting specification

Notice-PGA-E Rev.003 © 2015 ROHM Co., Ltd. All rights reserved. Precautions Regarding Application Examples and External Circuits 1. If change is made to the constant of an external circuit, please allow a sufficient margin considering variations of the characteristics of the Products and external components, including transient characteristics, as well as static characteristics. 2. You agree that application notes, reference designs, and associated data and information contained in this document are presented only as guidance for Products use . Therefore, in case you use such information, you are solely responsible for it and you must exercise your own independent verification and judgment in the use of such information contained in this document. ROHM shall not be in any way responsible or liable for any damages, expenses or losses incurred by you or third parties arising from the use of such information. Precaution for Electrostatic This Product is electrostatic sensitive product, which may be damaged due to electrostatic discharge. Please take proper caution in your manufacturing process and stor age so that voltage exceeding the Products maximum rating will not be applied to Products. Please take special care under dry condition (e .g. Grounding of human body / equipment / solder iron, isolation from charged objects, setting of Ionizer, friction prevention and temperature / humidity control). Precaution for Storage / Transportation 1. Product performance and soldered connections may deteriorate if the Products are stored in the places where: [a] the Products are exposed to sea winds or corrosive gases, including Cl2, H2S, NH3, SO2, and NO2 [b] the temperature or humidity exceeds those recommended by ROHM [c] the Products are exposed to direct sunshine or condensation [d] the Products are exposed to high Electrostatic 2. Even under ROHM recommended storage condition, solderability of products out of recommended storage time period may be degraded. It is strongly recommended to confirm solderability before using Products of which storage time is exceeding the recommended storage time period. 3. Store / transport cartons in the correct direction, which is indicated on a carton with a symbol. Otherwise bent leads may occur due to excessive stress applied when dropping of a carton. 4. Use Products within the specified time after opening a humidity barrier bag. Baking is required before using Products of which storage time is exceeding the recommended storage time period. Precaution for Product Label A two-dimensional barcode printed on ROHM Products label is for ROHM’s internal use only. Precaution for Disposition When disposing Products please dispose them properly using an authorized industry waste company. Precaution for Foreign Exchange and Foreign Trade act Since concerned goods might be fallen under listed items of export control prescribed by Foreign exchange and Foreign trade act, please consult with ROHM in case of export. Precaution Regarding Intellectual Property Rights 1. All information an d data including but not limited to application example contained in this document is for reference only. ROHM does not warrant that foregoing information or data will not infringe any intellectual property rights or any other rights of any third party regarding such information or data. 2. ROHM shall not have any obligations where the claims, actions or demands arising from the combination of the Products with other articles such as components, circuits, systems or external equipment (including software). 3. No license, expressly or implied, is granted hereby under any intellectual property rights or other rights of ROHM or any third parties with respect to the Products or the information contained in this document. Provided, however, that ROHM will not assert its intellectual property rights or other rights against you or your customers to the extent necessary to manufacture or sell products containing the Products, subject to the terms and conditions herein. Other Precaution 1. This document may not be reprinted or reproduced, in whole or in part, without prior written consent of ROHM. 2. The Products may not be disassembled, converted, modified, reproduced or otherwise changed without prior written consent of ROHM. 3. In no event shall you use in any way whatso ever the Products and the related technical information contained in the Products or this document for any military purposes, including but not limited to, the development of mass-destruction weapons. 4. The proper names of companies or products described in this document are trademarks or registered trademarks of ROHM, its affiliated companies or third parties.

Notice – WE Rev.001 © 2015 ROHM Co., Ltd. All rights reserved. General Precaution 1. Before you use our Products, you are requested to caref ully read this document and fully understand its contents. ROHM shall not be in any way responsible or liable for failure, malfunction or accident arising from the use of an y ROHM’s Products against warning, caution or note contained in this document. 2. All information contained in this documen t is current as of the issuing date and subject to change without any prior notice. Before purchasing or using ROHM’s Products, please confirm the latest information with a ROHM sales representative. 3. The information contained in this document is provided on an “as is” basis and ROHM does not warrant that all information contained in this document is accurate and/or error-free. ROHM shall not be in any way responsible or liable for any damages, expenses or losses incurred by you or third parties resulting from inaccura cy or errors of or concerning such information.

Minimum Package Quantity 3000 Packing Type Taping Constitution Materials List inquiry RoHS Yes BM1386GLV - Web Page Distribution Inventory