BL84 NORGREN | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 10

Technical content

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2017 - 9220c) © 2020 Norgren Ltd en 8.200.855.01 Technical features > Port size: 3/8” ... 3/4” (ISO G/PTF) > Unique Quikclamp connection system offers full modularity > 40 micron particle and high efficiency water removal (> 98%) > Double safety lock on bowl > Integrated gauge > Shut off valve, Regulator & Filter Regulator with tam- per resistance feature. > Light weight polycarbonate bowl > Metal bowl with prismatic liquid level indicator lens > High Corrosion resistance: Body and Metal bowl with electrophoretic paint finish > Easy to read flush mounted integrated pressure gauge as standard > All round (360°) visibility of sightdome for ease of drip rate setting Technical data BL84 - standard models Symbol Port size Shut off valve Drain Lubricator type Weight Model *1) (kg) G3/8 With Manual Microfog 1,65 BL84-321G G1/2 With Manual Microfog 1,65 BL84-421G G3/4 With Manual Microfog 1,65 BL84-621G G3/8 With Auto Microfog 1,65 BL84-301G G1/2 With Auto Microfog 1,65 BL84-401G G3/4 With Auto Microfog 1,65 BL84-601G G3/8 Without Manual Microfog 1,15 BL84-325G G1/2 Without Manual Microfog 1,15 BL84-425G G3/4 Without Manual Microfog 1,15 BL84-625G G3/8 Without Auto Microfog 1,15 BL84-305G G1/2 Without Auto Microfog 1,15 BL84-405G G3/4 Without Auto Microfog 1,15 BL84-605G *1) All models shown here are supplied with brackets and integrated gauge applicable for flow direction left to right. With flow direction right to left please use the online configurator www.norgren.com/air-preparation-configurator or contact Norgren Medium: Compressed air only Maximum supply pressure: Polycarbonate bowl: 10 bar (145 psi) Metal bowl: 20 bar (290 psi) Outlet pressure ranges: Filter element: 40 μm Port size: G3/8, G1/2, G3/4, 3/8 PTF, 1/2 PTF, 3/4 PTF Gauge: Integrated as standard Diaphragm Type: Relieving Drain: Manual or automatic Automatic drain operating conditions (float operated): Bowl pressure required to close drain: > 0,35 bar (5 psi) Bowl pressure required to open drain: ≤ 0,2 bar (2.9 psi) Minimum air flow required to close drain: 1 dm3/s (2 scfm) Ambient/Media temperature: Polycarbonate bowl: Metal bowl: Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F). Materials: Body: Die cast aluminium Body covers: ABS Bonnet: Acetal Valve: PP with Geolast seals Transparent Bowl : Polycar- bonate with Polyproplyene Guard. Metal Bowl: Die cast Aluminium with PA liquid level indicator lens Filter element: sintered PP Bowl ‘o’- ring: Chloroprene Elastomers: NBR BL84 -Filter/regulator - Lubricator Combination Units Excelon® Plus Modular System

BL84-˙˙˙˙ Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2017 - 9220c) © 2020 Norgren Ltden 8.200.855.02 Option selector *1) Port size Substitute 3/8” 3 1/2” 4 3/4” 6 Units Substitute Filter/Regulator w. auto drain, Micro fog lubricator, Polycar- bonate bowls Filter/Regulator w. auto drain, Oil fog lubricator, Polycarbonate bowls Filter/Regulator w. manual drain, Micro fog lubricator, Polycarbonate bowls Filter/Regulator w. manual drain, Oil fog lubricator, Polycar- bonate bowls Filter/Regulator w. auto drain, Micro fog lubricator, Metal bowls Filter/Regulator w. auto drain, Oil fog lubricator, Metal bowls Filter/Regulator w. manual drain, Micro fog lubricator, Metal bowls Filter/Regulator w. manual drain, Oil fog lubricator, Metal bowls *1) All models shown here are applicable for flow direction left to right. With flow direction right to left please use the online configurator www.norgren.com/air-preparation-configurator or contact Norgren Thread form Substitute PTF A ISO G parallel (standard) G Accessories Substitute Shutt-off valve & gauge & brackets Gauge & bracket 5 In addition to the standard box set units shown on this data sheet, further combinations can be configured using our online Air Preparation configurator: www.norgren.com/air-preparation-configurator

9.0 8.0 7.0 6.0 5.0 4.0 3.0 2.0 1.0 0.0 100 6020 7030 8040 9050 100 110 9.0 8.0 7.0 6.0 5.0 4.0 3.0 2.0 1.0 0.0 100 6020 7030 8040 9050 100 110 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2017 - 9220c) © 2020 Norgren Ltd en 8.200.855.03 Flow characteristicsOutlet pressure (bar) Air flow (dm3/s) Inlet pressure: 10 bar (145 psi) Port size: 1/2” , 40 µm element Inlet pressure: 10 bar (145 psi) Port size: 3/8” , 40 µm element Outlet pressure (bar) Air flow (dm3/s)

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2017 - 9220c) © 2020 Norgren Ltden 8.200.855.04 Quikclamp® Page 8 840014-51KIT Quikclamp® with bracket assembled Page 8 840014-52KIT Pressure sensing block 1/4 PTF Page 8 840016-50KIT Pressure sensing block G1/4 Page 8 840016-51KIT Full flow porting block 3/4” PTF Page 9 840028-50KIT Full flow porting block G3/4 Page 9 840028-53KIT Full flow porting block 3/4” PTF Page 9 840028-68KIT Full flow porting block G3/4 Page 9 840028-69KIT Port Adaptors Page 9 1/4 PTF 840015-01KIT 3/8 PTF 840015-02KIT 1/2 PTF 840015-03KIT 3/4 PTF 840015-04KIT G1/4 840015-09KIT G3/8 840015-10KIT G1/2 840015-11KIT G3/4 840015-12KIT Hybrid Quikclamp® *1 Page 8 840014-61 Hybrid Quikclamp® with bracket assembled *1 Page 8 840014-62 *1) To connect new Excelon Plus to old Excelon 74/73 units. Having the same hole centres as 74 series mounting bracket. A Quikclamp adds 13.6 mm to the overall width of a combination unit Electronic Pressure Sensor – stand alone version *3 Q84G IO-Link cables Connection cable M8x1 for integrated digital pressure switch Description Cable length (m) Model M8 female to M12 male 0,6 NC-084FS-124MS-A 1,0 NC-084FS-124MS-1 2,0 NC-084FS-124MS-2 5,0 NC-084FS-124MS-5 M8 female to free end 5,0 NC-084FS-00000-5 Pressure switch 18D (0,5 ... 8bar) *1 Page 9 0881300 Digital pressure switch Page 10 0860810 Pressure switch interface block (18D pressure switch) G1/4 Page 9 0337717000000000

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2017 - 9220c) © 2020 Norgren Ltd en 8.200.855.05 Lubricator sight dome kit Micro fog (red) 840055-50KIT Oil fog (green) 840055-51KIT Padlock Padlock 840055-01KIT Lockout device 840055-02KIT Silencer Porous plastic silencer *3) G1/4 M/S2 Plastic silencer *3) G1/4 0014600000000000 Sinter bronce silencer *3) 1/4 PTF MS002A *3) Max. pressure of silencers listed in this data sheet : 10bar. For pressure higher than 10bar please contact Norgren Maintenance/Service Filter cartridge 40 micron 840038-51KIT Auto drain kit with metal Nut - Imperial 6000-61KIT Auto drain kit with metal Nut - Metric 6000-60KIT Spare parts Filter Bowl (Guarded Poly bowl with auto drain 6 mm PIF) 840025-51KIT Filter Bowl (Guarded Poly bowl with manual drain) 840025-50KIT Filter Bowl (Metal with S/ Glass & auto drain, 6 mm PIF) 840003-51KIT Filter Bowl (Metal with S/ Glass & manual drain) 840003-50KIT Filter Bowl (Guarded Poly bowl with auto drain, 1/4 PIF) 840025-53KIT Filter Bowl (Metal with S/ Glass & auto drain, 1/4 PIF) 840003-56KIT R84 / B84 Elastomer Kit FRLB84-KIT Sinter bronce silencer *3) G1/4 T40C2800

Ø 49 Ø 62 140 210 119 135 71.5108 123 # 25 # 25 Ø 35 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2017 - 9220c) © 2020 Norgren Ltden 8.200.855.06 Dimensions Dimensions in mm Projection/First angle # Minimum clearance for bowl removal Shut-off valve, Filterregulator and Lubricator

Ø 49 140 Ø 42 71.5 # 25 162 # 25 Ø 35 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2017 - 9220c) © 2020 Norgren Ltd en 8.200.855.07 Dimensions Dimensions in mm Projection/First angleFilterregulator and Lubricator # Minimum clearance for bowl removal

11.5 119 54.3 102 6,5 90° ø 6,5 514 24,5 46 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2017 - 9220c) © 2020 Norgren Ltden 8.200.855.08 Dimensions in mm Projection/First angle Accessories Quikclamp®Quikclamp® with wall bracket Pressure sensing block Hybrid-Quikclamp® with wall bracket Hybrid-Quikclamp®

18 A/C

38.5 38.5 80 51 5746 G 1/4 G 1/8 300 6 5 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2017 - 9220c) © 2020 Norgren Ltd en 8.200.855.09 18D Pressure switchPorting block for 18D pressure switch 18D Porting block and 18D assembled Pipe adaptor Dimensions in mm Projection/First angle Full flow porting block horizontal Full flow porting block vertical

~300 31 G1/8 36,5 ~30 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2017 - 9220c) © 2020 Norgren Ltden 8.200.855.010 Dimensions in mm Projection/First angle Warning These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under »Technical features/ data«. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems or other applications not within published specifications, consult Norgren Ltd. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. EN - Englisch 51D Pressure switch - digital

1 Switch OUT 1, green LED

2 Switch OUT 2, red LED

3 Dustproof protector

4 Connector M12 x 1

5 Inlet port

6 Alternative inlet port G1/8 plugged

7 Thread for mounting screw