Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 5

Technical content

Edition • 2023-07-21T16:15:39+02:00 BL67 electronic module 2 analog outputs for current BL67-2AO-I Type BL67-2AO-I ID 6827179 Number of channels 2 Supply voltage 24 VDC Nominal voltage Vi 24 VDC Nominal current from field supply ð 50 mA Nominal current from module bus ð 40 mA Max. sensor supply Isens 250 mA per port, electronic short-circuit limiting Power dissipation, typical ð 1 W Output connectivity M12 Outputs Output type 0/4…20 mA Load resistance, resistive < 0.45 kò Load resistance, inductive < 1 mH Transmission frequency < 200 Hz Basic fault limit at 23 °C < 0.2 % Repeatability 0.05 % Temperature coefficient < 150 ppm/°C of full scale Resolution 16 Bit Measured-value display 16 bit signed integer 12 bit full range left justified Number of parameter bytes 6 ■ Independent of the fieldbus and connection technology used ■ Protection class IP67 ■ LEDs indicate status and diagnostic ■ Electronics galvanically separated from the field level via optocouplers ■ 2 analog outputs ■ 0/4…20 mA Functional principle BL67 electronic modules are plugged on the purely passive base modules which in turn are connected to the field devices. The separa- tion of connection level and electronics sim- plifies maintenance considerably. Flexibility is enhanced because the user can choose be- tween base modules with different connection technologies. The electronic modules are completely inde- pendent of the higher level fieldbus through the use of gateways.

Edition • 2023-07-21T16:15:39+02:00 Dimensions (W x L x H) 32 x 91 x 59 mm Approvals CE, cULus Ambient temperature -40…+70 °C Storage temperature -40…+85 °C Relative humidity 5…95 % (internal), level RH-2, no condensation (when stored at 45 °C) Vibration test Acc. to EN 61131 - up to 5 g (at 10 to 150 Hz) for mounting on DIN rail no drilling according to EN 60715, with end bracket - up to 20 g (at 10 up to 150 Hz) for mounting on base plate or machinery Therefore every second module has to be mounted with two screws each. Shock test Acc. to IEC 60068-2-27 Drop and topple acc. to IEC 68-2-31 and free fall to IEC 68-2-32 Electromagnetic compatibility Acc. to EN 61131-2 Protection class IP67 Tightening torque fixing screw 0.9…1.2 Nm

Edition • 2023-07-21T16:15:39+02:00 Compatible base modules Dimension drawing Type Pin configuration BL67-B-2M12 6827186 2 x M12, 5-pole, female, a-coded Comments Matching connection cable (for example): RKC5.501T-2-RSC5.501T/TXL Ident-No. 6628831 Pin Assignment

Edition • 2023-07-21T16:15:39+02:00 LED display LED Color Status Meaning D OFF No error message or diagnostics active. RED ON Failure of module bus communication. Check if more than 2 adja- cent electronic modules are pulled. Relevant modules are located between gateway and this module. RED FLASHING (0.5 Hz) Upcoming module diagnostics AO channel Not connected

Edition • 2023-07-21T16:15:39+02:00 Data mapping DATA BYTE Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Output m AO 0 LSB m+1 AO 0 MSB m+2 AO 1 LSB m+3 AO 1 MSB n = Offset of input data; depending on extension of station and the corresponding fieldbus. m = Offset of output data; depending on extension of station and the corresponding fieldbus. With PROFIBUS, PROFINET and CANopen, the I/O data of this module is localized within the process data of the whole station via the hardware configuration tool of the fieldbus master. With DeviceNet™, EtherNet/IP™ and Modbus TCP a detailed mapping table can be created with the TURCK configuration tool I/O-ASSISTANT.