en 8.240.805.01 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (1997 - 8085d) © 2015 IMI International s.r.o. BL64 - Olympian Plus plug-in system Filter/regulators and lubricators > Port size: 1/4“ ... 3/4“ (ISO G/PTF) > Complete air processing units pre-assembled, ready to install Medium: Compressed air only Maximum operating pressure: 17 bar (246 psi) Pressure range: Port sizes: G1/4, G3/8, G1/2 or G3/4 Gauge ports: Rc 1/8 Relieving: Standard Element: 40 μm Drain: Manual or automatic Automatic drain conditions: Pressure to close drain: > 0,3 bar (4.3 psi) Pressure to open drain: < 0,2 bar (2.9 psi) Minimum air flow to close drain: 0,6 dm3/s (1.3 scfm) Bowl size (lubricator): 0,2 litre (7 fluid oz) Ambient/Media temperature: Version with gauge: Air supply must be dry enough to avoid ice formation at tempera- tures below +2°C (+35°F). Materials: Body and yoke: Zinc alloy Connection piece: Aluminium Metal bowl: Aluminium Prismatic liquid level indicator: Grilamid Sight dome: transparent PA Element: Sintered bronze or plastic Elastomers: NBR Technical features Technical data BL64 - standard models; automatic drain Symbol Port size Size Pressure range (bar) Element (µm) Drain Lubricator Mounting Gauge Shut-off valve Model G1/4 — 0,3 ... 10 40 Automatic Micro fog Bracket With With BL64-201 G3/8 — 0,3 ... 10 40 Automatic Micro fog Bracket With With BL64-301 G1/2 Basic 0,3 ... 10 40 Automatic Micro fog Bracket With With BL64-401 G3/4 — 0,3 ... 10 40 Automatic Micro fog Bracket With With BL64-601 G1/4 — 0,3 ... 10 40 Automatic Oil fog Bracket With With BL64-211 G3/8 — 0,3 ... 10 40 Automatic Oil fog Bracket With With BL64-311 G1/2 Basic 0,3 ... 10 40 Automatic Oil fog Bracket With With BL64-411 G3/4 — 0,3 ... 10 40 Automatic Oil fog Bracket With With BL64-611 G1/4 — 0,3 ... 10 40 Automatic Micro fog — With With BL64-202 G3/8 — 0,3 ... 10 40 Automatic Micro fog — With With BL64-302 G1/2 Basic 0,3 ... 10 40 Automatic Micro fog — With With BL64-402 G3/4 — 0,3 ... 10 40 Automatic Micro fog — With With BL64-602 G1/4 — 0,3 ... 10 40 Automatic Oil fog — With With BL64-212 G3/8 — 0,3 ... 10 40 Automatic Oil fog — With With BL64-312 G1/2 Basic 0,3 ... 10 40 Automatic Oil fog — With With BL64-412 G3/4 — 0,3 ... 10 40 Automatic Oil fog — With With BL64-612 Pressure range: Port size: 1/4 PTF, 3/8 PTF, 1/2 PTF, 3/4 PTF Element: 5 μm Bowl size (lubricator): 1 litre Please contact IMI Norgren for following options:
Our policy is one of continued research and development. We therefore reserve the right to amend, Technical data BL64 - standard models, manual drain Symbol Port size Size Pressure range (bar) Element (µm) Drain Lubricator Mounting Gauge Shut-off valve Model G1/4 — 0,3 ... 10 40 Manual Micro fog Bracket With With BL64-221 G3/8 — 0,3 ... 10 40 Manual Micro fog Bracket With With BL64-321 G1/2 Basic 0,3 ... 10 40 Manual Micro fog Bracket With With BL64-421 G3/4 — 0,3 ... 10 40 Manual Micro fog Bracket With With BL64-621 G1/4 — 0,3 ... 10 40 Manual Oil fog Bracket With With BL64-231 G3/8 — 0,3 ... 10 40 Manual Oil fog Bracket With With BL64-331 G1/2 Basic 0,3 ... 10 40 Manual Oil fog Bracket With With BL64-431 G3/4 — 0,3 ... 10 40 Manual Oil fog Bracket With With BL64-631 G1/4 — 0,3 ... 10 40 Manual Micro fog — With With BL64-222 G3/8 — 0,3 ... 10 40 Manual Micro fog — With With BL64-322 G1/2 Basic 0,3 ... 10 40 Manual Micro fog — With With BL64-422 G3/4 — 0,3 ... 10 40 Manual Micro fog — With With BL64-622 G1/4 — 0,3 ... 10 40 Manual Oil fog — With With BL64-232 G3/8 — 0,3 ... 10 40 Manual Oil fog — With With BL64-332 G1/2 Basic 0,3 ... 10 40 Manual Oil fog — With With BL64-432 G3/4 — 0,3 ... 10 40 Manual Oil fog — With With BL64-632 Accessories Thread 3/2 Shut-off valve Threaded inlet only Threaded outlet only End connector kit Rear entry bracket kit G1/4 T64T-2GB-P1N T64T-2GC-P1N — — G3/8 T64T-3GB-P1N T64T-3GC-P1N — — G1/2 T64T-4GB-P1N T64T-4GC-P1N 74505-50 — G3/4 T64T-6GB-P1N T64T-6GC-P1N 74505-53 18-026-981 1/4 PTF T64T-2AB-P1N T64T-2AC-P1N — — 3/8 PTF T64T-3AB-P1N T64T-3AC-P1N — — 1/2 PTF T64T-4AB-P1N T64T-4AC-P1N 74505-52 — 3/4 PTF T64T-6AB-P1N T64T-6AC-P1N 74505-55 — Quick fill device Tamper resistant cap & seal wire Yoke connector kit Porting block Padlock with two keys 18-011-024 4355-51 74503-51 74507-50 0613633 (brass)
Our policy is one of continued research and development. We therefore reserve the right to amend, 185 237 ø 47 125 146 225 # ø 50 ø 6 33,5 186 239 # 171 224 # ø33 3 Basic dimensions Dimensions in mm Projection/First angle # Minimum clearance required to remove bowl
1 Main ports 1/4” , 3/8” , 1/2” or 3/4”
2 Quick fill device
3 For main ports 3/4” only
4 Sight glass
5 Reduces by 4 mm with knob in locked position
Our policy is one of continued research and development. We therefore reserve the right to amend, Rear entry bracket 18-026-981 AA A-A 54,5 83,5 7,5 41,5 20,5 G 3/4 29,5 35,8 68,5 +0,2 1 ‘O’-ring (included in scope of supply of bracket) G3/8 41,5 ø 22 G1/4 Porting block 74507-50
7 Padlock hole ø7,5 mm
27,517 13,5 ø C A Rc 1/8 3/2 Shut-off valve Symbol A B ø C Model 1 3 G1/4 48 27 T64T-2G*-P1N G3/8 48 27 T64T-3G*-P1N G1/2 48 27 T64T-4G*-P1N G3/4 51 33 T64T-6G*-P1N * B = Threaded inlet only, C = Threaded outlet only Dimensions in mm Projection/First angle These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under »Technical features/data«. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems or other applications not within published specifications, consult IMI Precision Engineering. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. Warning