BFD0003 BALLUFF | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 2

Technical content

Smart Automation and Monitoring System Ultrasonic Sensors BFD 3SAP-19N000-U01-LA2-CA2000 Order Code: BFD0003 Internet www.balluff.com eCl@ss 9.1: 27-27-28-03 Subject to change without notice: 289053 ETIM 6.0: EC001846 BFD0003_1.8_2024-11-18 1) Sealing ring Basic features Application Position monitoring in short stroke hydraulic cylinders Approval/Conformity CE UKCA cULus WEEE Basic standard IEC 60947-5-2 IEC 60947-5-7 Measuring principle Ultrasound Operating mode SIO Mode IO-Link Mode Secondary features for condition monitoring Internal temperature monitoring Series BFD Display/Operation Display 1x tricoloured - LED Function indicator yes Electrical connection Bending radius min., fixed cable 12 mm Bending radius min., flexible cable 12 mm Cable diameter D 3.4 mm ±0.1 mm Cable length L 2 m Conductor cross-section 0.14 mm² Connection type Cable, 2.0 m, TPU Number of conductors 4 Polarity reversal protected yes Short-circuit protection yes Electrical data Current draw max. 130 mA Load resistance RL max. (Analog I) 500 ohms Load resistance RL min. (Analog V) 2 kOhm No-load current Io max. at Ue 25 mA Operating voltage Ub 10...30 VDC Rated insulation voltage Ui 24 V DC Rated operating voltage Ue DC 24 V Ready delay tv max. 0.2 s Ripple max. (% of Ue) 10 % Ultrasonic Frequency 2000 kHz Environmental conditions Ambient temperature 0...85 °C EN 60068-2-27, Shock 30 g, 11 ms EN 60068-2-6, Vibration 30 g, 10…2000 Hz IP rating IP67 Relative humidity ≤ 90 %, non-condensing Storage temperature -20...85 °C Functional safety MTTF (40 °C) 308 a

Smart Automation and Monitoring System Ultrasonic Sensors BFD 3SAP-19N000-U01-LA2-CA2000 Order Code: BFD0003 Internet www.balluff.com eCl@ss 9.1: 27-27-28-03 Subject to change without notice: 289053 ETIM 6.0: EC001846 BFD0003_1.8_2024-11-18 Interface Analog output Analog, voltage/Analog, current selectable 4…20 mA/0…10 V Baud rate COM3 (230,4 kBaud) Interface IO-Link 1.1 Process data IN 6 bytes Process data OUT 0 bytes Process data cycle min. 1.4 ms Switching output Pin 2: PNP/NPN/push-pull NO/NC Pin 4: Push-pull NO/NC Material Gasket, material NBR Housing material 1.4104 stainless steel PBT Material jacket TPU Sealing ring, standard DIN 3869-18-NBR Mechanical data Burst pressure 455 bar Dimension Ø 30 x 30.9 mm Mounting connection M18x1 Pressure rating max. 350 bar Pressure rating, note oil pressure rated Sealing ring, size 20.9 × 15.7 × 1.5 mm Size Screw design Tightening torque max. 62 Nm Tightening torque min. 58 Nm Weight 98 g Range/Distance Measuring range 0...80 mm Measuring rate max. 500 Hz (digital)

1000 Hz (analog)

Non-linearity max. ±250 µm Repeat accuracy ± 50 µm Resolution ≤ 12 bits Resolution analog 12 Bit Resolution digital 1 µm Temperature drift max. 5 % Remarks For reliable operation, the sensor must have direct contact with the fluid. Ensure that the hydraulic circuit is free of air before operating the measuring system. For safe and reliable operation, prepare the mechanical connection of the hydraulic cylinder according to the instructions. The sensor is functional again after the overload has been eliminated. For additional information, refer to user's guide. For more information about MTTF and B10d see MTTF / B10d Certificate Indication of the MTTF- / B10d value does not represent a binding composition and/or life expectancy assurance; these are simply experiential values with no warranty implications. These declared values also do not extend the expiration period for defect claims or affect it in any way. Wiring Diagrams (Schematic)