BD540YT PANJIT | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
PAGE . 1May 14.2010-REV.01 BD540YT~BD5200YT PRELIMINARY SURFACE MOUNT SCHOTTKY BARRIER RECTIFIERS .098(2.5) .032(0.8) .264(6.7) .09 .09 .216(5.5) .024(0.6) .071(1.8) .02(0.5) .225(5.7) .307(7.8) .063(1.6) .082(2.1) .012(0.3) .248(6.3) (2.3) (2.3) .200(5.1) .016(0.4) .051(1.3) .209(5.3) .283(7.2) .047(1.2) TO-251AB U n i t:i n c h( m m )VOLTAGE 40 to 200 Volts 5 AmperesCURRENT
FEATURES
- Plastic package has Underwriters Laboratory Flammability Classification 94V-O
- For surface mounted applications
- Low profile package
- Built-in strain relief
- Low power loss, High efficiency
- High surge capacity
- For use in low voltage high frequency inverters, free wheeling, and polarity protection applications
- In compliance with EU RoHS 2002/95/EC directives MECHANCAL DATA
- Case: TO-251AB molded plastic
- Terminals: Solder plated, solderable per MIL-STD-750,Method 2026
- Polarity: As marking
- Weight: 0.0104 ounces, 0.297 grams. MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS Ratings at 25°C ambient temperature unless otherwise specified. Resistive or inductive load. PARAMETER SYMBOL BD540YT BD545YT BD550YT BD560YT BD580YT BD590YT BD5100YT BD5150YT BD5200YT UNITS Maximum Recurrent Peak Reverse Voltage V RRM 40 45 50 60 80 90 100 150 200 V Maximum RMS Voltage V RMS 28 31.5 35 42 56 63 70 105 140 V Maximum DC Blocking Voltage V DC 40 45 50 60 80 90 100 150 200 V Average Rectified Output Current (See Figure 1) I F(AV) 5.0 A Non-Repetitive Peak Forward Surge Current : 8.3ms single half sine-wave superimposed on rated load IFSM 100 A Peak Reverse Current T J=25 OC at Rated DC Blocking Voltage T J =100 OC IR 0.05 20 mA Typical Thermal Resistance(Note 2) R θJC 5.0 OC / W Operating Junction and Storage T emperature Range T J,T STG -55 to +150 -65 to +175 OC
PAGE . 2May 14.2010-REV.01 BD540YT~BD5200YT PRELIMINARY RATING AND CHARACTERISTIC CURVES Fig.1- FORWARD CURRENT DERATING CURVE Fig.2 -MAXIMUM NON-REPETITIVE SURGE CURRENT PEAK FORWARD SURGE CURRENT AMPERES NO. OF CYCLE AT 60H Z Fig.3-TYPICAL REVERSE CHARACTERISTIC 11 0 1 0 100 Fig.4- TYPICAL INSTANTANEOUS FORWARD CHARACTERISTIC 0.1 1.0 0.4 0.6 0.8 1.0 T= 2 5CA O 40V-45V 50V-60V 80V-100V FORWARD CURRENT, AMPERES FORWARD VOLTAGE, VOLTS 150-200V INSTANTANEOUS REVERSE CURRENT ,m A PERCENT OF INSTANTANEOUS REVERSE VOLTAGE,(%) 120 140 1.0 0.1 .01 .001 02 04 06 08 0 1 0 0 T =100 CJ O T=J 75 C O T=J 25 C O 5.0 4.0 2.0 RESISTIVE OR INDUCTIVE LOAD 1.0 3.0 0 20 40 60 80 100 120 140 160 180 AVERAGE FORWARD RECTIFIED CURRENT AMPERES =4 0 V = 45-200V CASE TEMPERATURE, C O 1.2