BAS70 VISHAY | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 4

Technical content

Features

/C0068Low Turn–on Voltage /C0068Fast Switching /C0068PN Junction Guard Ring for Transient and ESD Protection

Applications

Fast switches in thick and thin film circuits 94 8550 Absolute Maximum Ratings Tj = 25/C0095C Parameter Test Conditions Symbol Value Unit Repetitive peak reverse voltage =Working peak reverse voltage =DC Blocking voltage VRRM =VRWM =VR 70 V Peak forward surge current tp<1s, on fiberglass substrateIFSM 600 mA Average forward current IFAV 100 mA Forward current on fiberglass substrate IF 200 mA Power dissipation on fiberglass substrate Pd 200 mW Junction and storage temperature range Tj=Tstg –55...+150 /C0176C Maximum Thermal Resistance Tj = 25/C0095C Parameter Test Conditions Symbol Value Unit Junction ambient on fiberglass substrate R thJA 625 K/W

BAS70/–04/–05/–06 Vishay Telefunken Rev. 1, 01-Apr-992 (4) Document Number 85507www.vishay.de • FaxBack +1-408-970-5600

Electrical Characteristics

Tj = 25/C0095C Parameter Test Conditions Symbol Min Typ Max Unit Forward voltage IF=1.0mA, tp<300/C0109s VF 410 mVg IF=15mA, tp<300/C0109s VF 1000 mV Reverse current VR =50V, tp<300/C0109s IR 20 100 nA Breakdown voltage IR =10/C0109A V(BR) 70 V Diode capacitance VR =0V, f=1MHz C D 1.5 2.0 pF Reverse recovery timeIF=IR =10mA to IR =1mA, RL=100/C0087 trr 5 ns Dimensions in mm 14384 Case: SOT23, molded plastic Polarity: see diagrams below Mounting position: any Approx. weight: 0.008 grams

BAS70/–04/–05/–06 Vishay Telefunken Rev. 1, 01-Apr-99 3 (4) www.vishay.de • FaxBack +1-408-970-5600Document Number 85507 14385 top view BAS70 14388 top view BAS70–04, connected in series 14387 top view BAS70–05, common cathode 14386 top view BAS70–06, common anode

BAS70/–04/–05/–06 Vishay Telefunken Rev. 1, 01-Apr-994 (4) Document Number 85507www.vishay.de • FaxBack +1-408-970-5600 Ozone Depleting Substances Policy Statement It is the policy of Vishay Semiconductor GmbH to 1. Meet all present and future national and international statutory requirements. 2. Regularly and continuously improve the performance of our products, processes, distribution and operating systems with respect to their impact on the health and safety of our employees and the public, as well as their impact on the environment. It is particular concern to control or eliminate releases of those substances into the atmosphere which are known as ozone depleting substances (ODSs). The Montreal Protocol (1987) and its London Amendments (1990) intend to severely restrict the use of ODSs and forbid their use within the next ten years. Various national and international initiatives are pressing for an earlier ban on these substances. Vishay Semiconductor GmbH has been able to use its policy of continuous improvements to eliminate the use of ODSs listed in the following documents. 1. Annex A, B and list of transitional substances of the Montreal Protocol and the London Amendments respectively 2. Class I and II ozone depleting substances in the Clean Air Act Amendments of 1990 by the Environmental Protection Agency (EPA) in the USA 3. Council Decision 88/540/EEC and 91/690/EEC Annex A, B and C (transitional substances) respectively. Vishay Semiconductor GmbH can certify that our semiconductors are not manufactured with ozone depleting substances and do not contain such substances. We reserve the right to make changes to improve technical design and may do so without further notice. Parameters can vary in different applications. All operating parameters must be validated for each customer application by the customer. Should the buyer use Vishay-Telefunken products for any unintended or unauthorized application, the buyer shall indemnify Vishay-Telefunken against all claims, costs, damages, and expenses, arising out of, directly or indirectly, any claim of personal damage, injury or death associated with such unintended or unauthorized use. Vishay Semiconductor GmbH, P.O.B. 3535, D-74025 Heilbronn, Germany Telephone: 49 (0)7131 67 2831, Fax number: 49 (0)7131 67 2423