Isolated 3W Regulated Single Output AC/DC Converters KAC_BAC3C.B01 Page 1 of 10 www.murata.com www.murata.com For full details go to https://www.murata.com/en- global/products/power/rohs SELECTION GUIDE Order Code Output Power Output Voltage Output Current Ripple & Noise Efficiency Isolation Capacitance MTTF1 115V 230V 115V 230V MIL 217 Telcordia mVp-p % kHrs BAC3S05DC 3 5 0.6 45 60 45 60 75 77 72 75 45 993 20443 BAC3S12DC 3 12 0.25 50 100 60 100 77 80 74.5 77 45 1021 22386 BAC3S24DC 3 24 0.125 120 200 150 200 78 81 76 78 45 1059 24680 INPUT CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Voltage range All input types 85 115/230 264 VAC All input types 120 370 VDC Input frequency 47 50/60 63 Hz Switching frequency 64 kHz Input current Nominal Vin = 115VAC 65 mA Nominal Vin = 230VAC 40 mA Inrush current Nominal Vin = 115VAC 11 A Nominal Vin = 230VAC 23 Input leakage current 250VAC 25 μA No load power consumption BAC3S05DC 115VAC 67 mW 230VAC 150 BAC3S12DC 115VAC 46 230VAC 129 BAC3S24DC 115VAC 101 230VAC 155 ISOLATION CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Isolation test voltage Production tested for 1 second 4700 VDCQualification tested for 1 minute 4700 Resistance Viso = 1000VDC 100 MΩ Safety standard UL62368-1 Reinforced Creepage and clearance 8.4mm 240 VrmsEN62368-1 240 ANSI/AAMI ES60601-1 2 1 MOPP & 2 MOOP 240 TEMPERATURE CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Operation Convection cooling 0.2m/s -40 85 °CStorage -40 85 Product temperature rise above ambient BAC3S24DC 15 All others 20
FEATURES
UL62368-1 recognised EN62368-1 certified IEC61558-1 & IEC61558-2-16 certified ANSI/AAMI ES60601-1, 1 MOPP/2 MOOP recognition pending Wide input voltage range 85-264VAC/ 120-370VDC Operating temperature range –40°C to 85°C 4.7kVDC isolation ‘Hi Pot Test’ 5V, 12V & 24V single regulated outputs Over current protection Short circuit protection Primary side regulation Meets EMC class B with no external components No external components required PRODUCT OVERVIEW The BAC3 series delivers an output power of 3 watts from -40°C to 65°C, operating up to 85°C with derating, from AC or DC input voltages. The BAC3 series small footprint is EMC class B compliant without the need of any external components. The BAC3 series is suited to medical applications with 1 MOPP and 2 MOOP . With high efficiency at low loads and low no load power consumption, the BAC3 supports standby mode operation for applications in industrial, medical, automation, IOT as well as household and home automation. 1. Calculated using MIL-HDBK-217F and Telcordia SR-332 calculation model at TA=25°C with nominal input voltage 115VAC at full load. ANSI/AAMI ES60601-1 recognition is currently pending. All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
Isolated 3W Regulated Single Output AC/DC Converters KAC_BAC3C.B01 Page 2 of 10 www.murata.com OUTPUT CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Minimum load 10 % Initial voltage accuracy All output types ±4 % Line regulation Low line to high line BAC3S24DC ±0.2 ±0.5 %All others ±0.05 ±0.5 Load regulation 10% total load to 100% total load 115VAC BAC3S05DC ±0.3 ±1 %All others ±0.1 ±1 230VAC BAC3S05DC ±0.2 ±1 All others ±0.1 ±1 Temperature coefficient 0.05 %/°C Transient response Peak deviation - 50-75% & 75-50% swing ±2 %Vout Settling time (within 1% Vout Nom.) 2 ms Current limit inception BAC3S05DC 160 %BAC3S12DC 150 BAC3S24DC 130 Hold up time 115VAC 25 ms230VAC 125 ABSOLUTE MAXIMUM RATINGS Short-circuit protection Continuous, automatic recovery Input voltage 277VAC Lead temperature 1.0mm from case for 7 +2/-0 seconds (to JEDEC JESD22-B106) 270±5°C Shelf life (1 year) Please refer to reconditioning application notes. Wave Solder Wave Solder profile not to exceed the profile recommended in IEC 61760-1 Section 6.1.3. Please refer to application notes for further information.
Isolated 3W Regulated Single Output AC/DC Converters KAC_BAC3C.B01 Page 3 of 10 www.murata.com TECHNICAL NOTES ISOLATION VOLTAGE ‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage, applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. Murata Power Solutions BAC3 series of AC/DC converters are all 100% production tested at their stated isolation voltage. This is 4.7kVDC for 1 second. The BAC3 has been recognised by Underwriters Laboratory to 240Vrms for Reinforced Insulation. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage. SAFETY APPROVAL ANSI/AAMI ES60601-1 The BAC3 series is pending recognition by Underwriters Laboratory (UL) to ANSI/AAMI ES60601-1 and provides 1 MOPP (Means Of Patient Protection) and 2 MOOP (Means Of Operator Protection) based upon a working voltage of 240Vrms max., between Primary and Secondary. File number E202895 applies. EN62368-1 The BAC3 series has been certified by Demko (D) to EN62368 for reinforced insulation to a working voltage of 240Vrms. File number D-07177 applies. UL62368-1 The BAC3 series has been recognised by Underwriters Laboratory (UL) to UL62368 for reinforced insulation to a working voltage of 240Vrms. File number E151252 applies. Creepage and clearance 8.4mm Working altitude OVC II 5000m IEC61558-1 & IEC61558-2-16 The BAC3 series has been certified by TUV SUD to IEC61558-1 & IEC61558-2-16. RoHS COMPLIANCE INFORMATION This series is compatible with RoHS soldering systems with a peak wave solder temperature of 260ºC for 10 seconds based on IEC 61760-1. Please refer to application notes for further information. The pin termination finish on this product series is Hot Dipped over Matte Tin with Nickel Preplate. The series is backward compatible with Sn/Pb soldering systems. For further information, please visit www.murata.com/en-global/ products/rohs
Isolated 3W Regulated Single Output AC/DC Converters KAC_BAC3C.B01 Page 4 of 10 www.murata.com EMC/ESD STANDARDS Conducted emissions EN55032/FCC class B Radiated emissions EN55032/FCC class B ESD immunity IEC/EN 61000-4-2, Level 1, criteria A Radiated, radio-frequency, electromagnetic field immunity IEC/EN61000-4-3, 10V/m perf criteria A 10V/m 80-1000MHz 3V/m 1.4-2.0GHz 1V/m 2.0-2.7GHz All 80% 1kHz am mod all perf criteria A EFT/burst IEC/EN61000-4-4, 2kV, perf criteria A Surge immunity IEC/EN61000-4-5, 1kV perf criteria A Conducted field immunity IEC/EN61000-4-6, 10 Vrms 0.15-80MHz 80% 1kHz am mod perf criteria A Power frequency magnetic field immunity IEC/EN61000-4-8, 50Hz/60Hz 30 A/m perf criteria A Harmonic current emissions IEC/EN61000-3-2 Voltage changes, voltage fluctuations and flicker IEC/EN61000-3-3 Voltage dips, short interruptions and variations IEC/EN61000-4-11, 100% for 20ms, 60% for 200ms, 30% for 500ms and 100% for 5s perf criteria A-A-A-C. ENVIRONMENTAL VALIDATION TESTING The following tests have been conducted on this product series, as part of our design verification process. The datasheet characteristics specify user operating conditions for this series, please contact Murata if further information about the tests is required. Test Standard Condition Temperature cycling JEDEC JESD22-A104 200 cycles. -40°C to 105°C, 15 minutes hold at each extreme including transitions. Humidity bias JEDEC JESD22-A101 85±2°C, 85±5% R.H. for 1000 (+168/-24) hours Storage life JEDEC JESD22-A103 105°C +10/-0°C for ≥1000 hours Vibration BS EN 61373 with respect to BS EN 60068-2-64, Test Fh Category 1 Class B. 5 – 150Hz. Level at each axis – Vertical, Traverse and Longitudinal: 5.72m/s2 rms. 5 hours in each axis. Crest factor: 3 Sigma. Device is secured via the pins. Shock BS EN 61373: Category 1 Class B Test is 30ms duration, 3 shocks in each sense of 3 mutually perpendicular axes (18 shocks total). Level at each axis as follows: Vertical, Traverse and Longitudinal: 50m/s2. Device is secured via pins. Solderability EIA/IPC/JEDEC J-STD-002 Test A1 Parts are baked for 4 hours at a temperature of 155°C, within 72 hours they are dipped in flux for 10 seconds. Followed by dipping the parts in a solder pot at 255°C ±5°C for 5 seconds (96SC tin/silver/copper) Solder Heat JEDEC JESD22-B106 The test sample is subjected to a molten solder bath at 270°C ±5°C for 7 +2/-0 seconds (96SC tin/silver/ copper). The leads are dipped in the solder bath to within 1mm of the device body. Solder Heat (Hand) MIL-STD-202 Method 210, Condition A The soldering iron is heated to 350°C ± 10°C and applied to the terminations for a duration of 4 to 5 seconds. Solvent cleaning Resistance to cleaning agents Solvent – Novec 71IPA & Topklean EL-20A. Pulsed ultrasonic immersion 45°C - 65°C Solvent Resistance MIL-STD-883 Method 2015 The parts and the bristle portion of the brush are immersed in Isopropanol for a minimum of 1 minute. The parts are brushed 3 times, after the third time the parts are blown dry and inspected. Lead Integrity (Adhesion) MIL-STD-883 Method 2025 Leads are bent through 90º until a fracture occurs. Lead Integrity (Fatigue) MIL-STD-883 Method 2004, Condition B 1 The leads are bent to an angle of 15º. Each lead is subjected to 3 cycles. Lead Integrity (Tension/ Pull) MIL-STD-883 Method 2004, Condition A1 Pull of 0.227kg applied for 30 seconds. The force is then increased until the pins snap.
Isolated 3W Regulated Single Output AC/DC Converters KAC_BAC3C.B01 Page 5 of 10 www.murata.com APPLICATION NOTES Output Capacitance and start-up times The BAC3 series does not require output capacitors to meet datasheet specification. To meet datasheet specification, output capacitance should not exceed: Part No. Maximum Load Capacitance Load capacitance to meet start-up Start-up times with maxi- mum load capacitance Start up times with 10μF μF μF ms ms BAC3S05DC 820 10 1800 510 BAC3S12DC 330 10 730 310 BAC3S24DC 180 10 730 300 When operational in an application will operate down to -40°C. For start-up below nominal input voltage ≤115VAC, at very low temperatures, please refer the temperature derating graphs. Oscilloscope 10μF Load Twisted wire: #20AWG-30cm -Vout +Vout CHARACTERISATION TEST METHODS Ripple & Noise Characterisation Method Ripple and noise measurements are performed with the following test configuration. C1 10μF electrolytic capacitor Differential Mode Noise Test Schematic PART NUMBER STRUCTURE BAC 3 S XX D C Series name Power rating Output type S - Single D - Dual RoHS compliant Package type S - SIP D - DIP M - Surface mount Z - ZIP Output voltage
Isolated 3W Regulated Single Output AC/DC Converters KAC_BAC3C.B01 Page 6 of 10 www.murata.com EFFIECIENCY VS LOAD BAC3S05DC BAC3S12DC BAC3S24DC 0 1 02 03 04 05 06 07 08 09 0 1 0 0 Efficiency (%) Load (%) 85V 115V 230V 264V 0 1 02 03 04 05 06 07 08 09 0 1 0 0 Efficiency (%) Load (%) 85V 115V 230V 264V 0 1 02 03 04 05 06 07 08 09 0 1 0 0 Efficiency (%) Load (%) 85V 115V 230V 264V APPLICATION NOTES (Continued) Minimum Load The minimum load to meet full datasheet specification is 10% of the full rated load across the specified input voltage range. Reconditioning This series contains electrolytic capacitors, which require reconditioning if the product is stored non-powered for more than 2 years from the date of manufacture. To recondi- tion the capacitors, an AC input voltage should be applied with output loading for 10 minutes. For further information please contact Murata.
Isolated 3W Regulated Single Output AC/DC Converters KAC_BAC3C.B01 Page 7 of 10 www.murata.com TEMPERATURE DERATING - PART OPERATIONAL BAC3S05DC BAC3S12DC BAC3S24DC 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% - 4 0 - 3 0 - 2 0 - 1 00 1 02 03 04 05 06 07 08 09 0 1 0 0 Load (%) Temperature (°C) 85VAC 115Vac 230VAC 264VAC 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% - 4 0 - 3 0 - 2 0 - 1 00 1 02 03 04 05 06 07 08 09 0 1 0 0 Load (%) Temperature (°C) 85VAC 115VAC 230VAC 264VAC 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% - 4 0 - 3 0 - 2 0 - 1 00 1 02 03 04 05 06 07 08 09 0 1 0 0 Load (%) Temperature (°C) 85VAC 115VAC 230VAC 264VAC
Isolated 3W Regulated Single Output AC/DC Converters KAC_BAC3C.B01 Page 8 of 10 www.murata.com TEMPERATURE DERATING - COLD STARTUP BAC3S05DC BAC3S12DC BAC3S24DC 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% - 4 0 - 3 0 - 2 0 - 1 00 1 02 03 04 05 06 07 08 09 0 1 0 0 Load (%) Temperature (°C) 85VAC 115VAC 230VAC 264VAC 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% - 4 0 - 3 0 - 2 0 - 1 00 1 02 03 04 05 06 07 08 09 0 1 0 0 Load (%) Temperature (°C) 85VAC 115VAC 230VAC 264VAC 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% - 4 0 - 3 0 - 2 0 - 1 00 1 02 03 04 05 06 07 08 09 0 1 0 0 Load (%) Temperature (°C) 85VAC 115VAC 230VAC 264VAC
Isolated 3W Regulated Single Output AC/DC Converters KAC_BAC3C.B01 Page 9 of 10 www.murata.com PACKAGE SPECIFICATIONS MECHANICAL DIMENSIONS PIN CONNECTIONS Pin Function
1 AC(N)
2 AC(L)
TUBE OUTLINE DIMENSIONS RECOMMENDED FOOTPRINT DETAILS Weight: 18g Unless otherwise specified all dimensions in mm. Tube Length : 550mm±2.0. Tube Quantity : 20 All dimensions in mm. Unless otherwise specified all pins within ±0.30 of true position. The isolation barrier shown must not have any copper traces even on internal layers. This is to avoid compromising the creepage and clearance distance. PCB layouts must take into consideration the required clearance and creepage requirements to maintain the clearance and creepage of the isolation barrier. All dimensions in mm.
Isolated 3W Regulated Single Output AC/DC Converters KAC_BAC3C.B01 Page 10 of 10 Murata Power Solutions (Milton Keynes) Ltd. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2023 Murata Power Solutions (Milton Keynes) Ltd. This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: https://www.murata.com/en-eu/products/power/requirements www.murata.com DISCLAIMER Unless otherwise stated in the datasheet, all products are designed for standard commercial and industrial applications and NOT for safety-critical and/or life-critical applications. Particularly for safety-critical and/or life-critical applications, i.e. applications that may directly endanger or cause the loss of life, inflict bodily harm and/or loss or severe damage to equipment/property, and severely harm the environment, a prior explicit written approval from Murata is strictly required. Any use of Murata standard prod- ucts for any safety-critical, life-critical or any related applications without any prior explicit written approval from Murata shall be deemed unauthorised use. These applications include but are not limited to:
- Aircraft equipment
- Aerospace equipment
- Undersea equipment
- Power plant control equipment
- Medical equipment
- Transportation equipment ( automobiles, trains, ships, etc.)
- Traffic signal equipment
- Disaster prevention / crime prevention equipment
- Data Processing equipment Murata makes no express or implied warranty, representation, or guarantee of suitability, fitness for any particular use/purpose and/or compatibility with any applica- tion or device of the buyer, nor does Murata assume any liability whatsoever arising out of unauthorised use of any Murata product for the application of the buyer. The suitability, fitness for any particular use/purpose and/or compatibility of Murata product with any application or device of the buyer remain to be the responsibility and liability of the buyer. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards that anticipate dangerous consequences of failures, moni- tor failures and their consequences, lessen the likelihood of failures that might cause harm, and take appropriate remedial actions. Buyer will fully indemnify and hold Murata, its affiliated companies, and its representatives harmless against any damages arising out of unauthorised use of any Murata products in any safety-critical and/ or life-critical applications. Remark: Murata in this section refers to Murata Manufacturing Company and its affiliated companies worldwide including, but not limited to, Murata Power Solutions.