Isolated 1W Regulated Single Output AC/DC Converters KAC_BAC1C.C01 Page 1 of 14 www.murata-ps.com For full details go to www.murata-ps.com/rohs www.murata.com SELECTION GUIDE Order Code Output Power Output Voltage Output Current Ripple & Noise Efficiency Isolation Capacitance MTTF1 WV A 115V & 230V 277V 115V 230V 277V pF MIL 217 mVp-p % kHrs BAC1S05SC 1 5 0.2 50 120 50 120 70 74 69 73 67 71 11 1613 38213 BAC1S12SC 1 12 0.083 60 120 60 130 70 74 69 73 68 72 11 2038 44328 BAC1S24SC 1 24 0.042 85 120 100 150 68 73 67 71 64 69 11 1816 40463 INPUT CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Voltage range All input types 85 115/230/277 305 VAC All input types 70 400 VDC Input frequency 47 50/60 63 Hz Switching frequency Nominal Vin = 115VAC 50 kHzNominal Vin = 115VAC 24Vin 35 Nominal Vin = 230VAC/277VAC 40 Nominal Vin = 230VAC/277VAC 24Vin 25 Input current Nominal Vin = 115VAC 25 mANominal Vin = 230VAC 17 Nominal Vin = 277VAC 16 Inrush current Nominal Vin = 115VAC 6 A Nominal Vin = 230VAC & 277VAC 9 Input leakage current 230VAC 1 μA Stand by power BAC1S05SC 115VAC 20 mW 230VAC 61 277VAC 85 BAC1S12SC 115VAC 58 230VAC 68 277VAC 92 BAC1S24SC 115VAC 26 230VAC 81 277VAC 117 ISOLATION CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Isolation test voltage Production tested for 1 seconds 4000 VACQualififcation tested for 1 minute 4000 Resistance Viso = 1000VDC 100 MΩ

FEATURES

„ UL62368-1 recognized „ EN62368-1 certified „IEC61558-1 certified „ ANSI/AAMI ES60601-1, 1 MOPP/2 MOOP’s recognition pending „Wide input voltage range 85-305VAC/ 70-400VDC „Operating temperature range –40°C to 85°C „4kVAC isolation ‘Hi Pot Test’ „5V, 12V & 24V single regulated outputs „Short circuit protection „No optocoupler „Low standby power PRODUCT OVERVIEW The BAC1 series is the first series release from the BAC family of board mount AC/DC converters. The BAC1 series operates over the wide industrial temperature range of -40°C to +85°C, supporting operation in still air for the most demanding environments. Models are capable of operation to 85°C, and operate from -40°C. The BAC1 has ultra low standby power consumption for demanding energy and cost saving applications. 1. Calculated using MIL-HDBK-217F FN2 and Telcordia SR-332 calculation model at TA=25°C with nominal input voltage at full load. All specifications typical at TA=25°C, nominal input voltage, rated output current and recommended components unless otherwise specified.

Isolated 1W Regulated Single Output AC/DC Converters KAC_BAC1C.C01 Page 2 of 14 www.murata.com TEMPERATURE CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Operation Sealed box with no air flow -40 85 °CStorage -40 125 Product temperature rise above ambient 16 ABSOLUTE MAXIMUM RATINGS Short-circuit protection Continuous Input voltage Vin 310VAC Wave solder Wave Solder profile not to exceed the profile recommended in IEC 61760-1 Section 6.1.3. Please refer to application notes for further information. Lead temperature 1.0mm from case for 7 seconds (to JEDEC JESD22-B106) 270°C OUTPUT CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Minimum load 5% Initial voltage accuracy 5V output types ±5 %All other output types ±4 Line regulation Low line to high line 5V output types ±0.3 ±1 %All other output types ±0.1 ±1 Load Regulation 5% total load to 100% total load ±0.2 ±1.5 % Total regulation Includes line, load, temperature and drift ±5 % Temperature coefficient 0.05 %/°C Transient Response Peak deviation - Single Output (50-75% & 75- 50% swing) BAC1S05SC ±4 %VoutBAC1S12SC ±3 BAC1S24SC ±2 Settling time (within 1% Vout Nom.) 24V output type 8 msAll other output types 6 Current limit inception Auto-recovery 115VAC & 230VAC 150 280 %277VAC 150 310 Hold up time From power fail 115VAC 50 ms230VAC 240 277VAC 380

Isolated 1W Regulated Single Output AC/DC Converters KAC_BAC1C.C01 Page 3 of 14 www.murata.com TECHNICAL NOTES ISOLATION VOLTAGE ‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage, applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. Murata Power Solutions BAC1 series of AC-DC converters are all 100% production tested at their stated isolation voltage. This is 4kVAC for 3 seconds. A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?” The BAC1 series has been recognized by Underwriters Laboratory to 277VAC for Reinforced Insulation. The BAC1 series has been certified by Demko to 277VAC for Reinforced Insulation. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage. SAFETY APPROVAL ANSI/AAMI ES60601-1 The BAC1 series is pending recognition by Underwriters Laboratory (UL) to ANSI/AAMI ES60601-1 and provides 2 MOOP (Means Of Operator Protection) and 1 MOPP (means of patient protection) based upon a working voltage of 277VAC max., between Primary and Secondary. File number E202895 applies. EN62368-1 The BAC1 series has been certified by Demko (D) to EN62368 for reinforced insulation to a working voltage of 277VAC. Certificate number D-07177 applies. UL62368-1 The BAC1 series has been recognized by Underwriters Laboratory (UL) to UL62368 for reinforced insulation to a working voltage of 277VAC. File number E151252 applies. Creepage 8.3mm and clearance 6.6mm Working altitude OVC II 5000m FUSING As stated in the application notes, to meet datasheet specifications it is required that a 1W 10Ω fusible resistor is fitted. IEC61558-1 The BAC1 series has been certified by TUV SUD to IEC61558-1. Input 100-240VAC, 50-60Hz; 0.03A; Output 5-24VDC; 0.2-0.042A; 1W. Maximum ambient of 70°C Working altitude OVC II 5000m Fuse: 100mA, Time-lag T RoHS COMPLIANCE INFORMATION This series is compatible with RoHS soldering systems with a peak wave solder temperature of 260ºC for 10 seconds based on IEC 61760-1. Please refer to application notes for further information. The pin termination finish on this product series is Hot Dipped over Matte Tin with Nickel Preplate. The series is backward compatible with Sn/Pb soldering systems. For further information, please visit www.murata-ps.com/rohs II Up to 5000m S

Isolated 1W Regulated Single Output AC/DC Converters KAC_BAC1C.C01 Page 4 of 14 www.murata.com ENVIRONMENTAL VALIDATION TESTING The following tests have been conducted on this product series, please contact Murata if further information about the tests is required. Test Standard Condition Temperature Cycling JEDEC JESD22-A104 200 cycles. -40°C to 105°C, 15 minutes hold at each extreme. HAST (Unbiased) JEDEC JESD22-A118 96Hrs +2/-0Hrs at 130°C ± 2°C, 85% ± 5% R.H. Storage Life JEDEC JESD22-A103, Condition A 125°C +10/-0°C for ≥1000 hours Vibration BS EN 61373 with respect to BS EN 60068-2-64 2008, Test Fh Category 1 Class B 5 – 150Hz. Level at each axis – Vertical, Traverse and Longitudinal: 5.72m/s2 rms. 5 hours in each axis. Crest factor: 3 Sigma. Device is secured via pins/leads. Shock BS EN 61373: 2010, Category 1 Class B Test is 30ms duration, 3 shocks in each sense of 3 mutually perpendicular axes (18 shocks total). Level at each axis as follows: Vertical, Traverse and Longitudinal: 50m/s2. Device is secured via pins/leads. Solderability IPC/ECA J-STD-002, Test A1 Parts are baked for 4 hours at a temperature off 155°C, within 72 hours they are dipped in flux for 10 seconds. Followed by dipping the parts in a solder pot at 255°C ±5°C for 5 seconds (96SC tin/silver/copper) Solvent cleaning Resistance to cleaning agents. Solvent – Novec 71IPA & Topklean EL-20A. Pulsed ultrasonic immersion 45°C- 65°C Solvent resistance MIL-STD-883, Method 2015 The parts and the bristle portion of the brush are immersed in Isopropanol for a minimum of 1 minute. The parts are brushed 3 times, after the third time the parts are blown dry and inspected. Solder Heat JEDEC JESD22-B106 The test sample is subjected to a molten solder bath at 270 ±5°C for 7 +2/-0 seconds (96SC tin/silver/copper). The leads are dipped in the solder bath to within 1mm of the device body. Solder Heat (Hand) MIL-STD 202, Method 210, Condition A The soldering iron is heated to 350°C ± 10°C and applied to the terminati ons for a duration of 4 to 5 seconds. Lead Integrity (Adhesion) MIL-STD 883, Method 2025 Leads are bent through 90º until a fracture occurs. Lead Integrity (Fatigue) MIL-STD 883, Method 2004, Condition The leads are bent to an angle of 15º. Each lead is subjected to 3 cycles. Lead Integrity (Tension/ Pull) MIL-STD 883, Method 2004, Condition A1 Pull of 0.227kg applied for 30 seconds. The force is then increased until the pins snap. EMC STANDARDS Conducted input noise EN55032, Class B with external X cap Radiated noise EN55032, Class B ESD immunity IEC/EN61000-4-2 level 3 perf criteria A Conducted transient immunity EN61000-4-6, 10 Vrms, perf criteria A Conducted surge immunity EN61000-4-5, Installation class 3, perf criteria A EFT/Burst EN61000-4-4, level 3, perf criteria A Radiated field immunity EN61000-4-3, 10 V/m, perf criteria A Dips and interruptions EN61000-4-11, 100% reduction for 20ms (A), 60% reduction for 200ms (A), 30% reduction for 500ms (A), 100% reduction for 5s (B) Magnetic fields EN61000-4-8 30A/m, perf criteria A PART NUMBER STRUCTURE BAC 1 S XX S C Series name Power rating Output type S - Single D - Dual RoHS compliant Package type S - SIP D - DIP M - Surface mount Z - ZIP Output voltage

Isolated 1W Regulated Single Output AC/DC Converters KAC_BAC1C.C01 Page 5 of 14 www.murata.com APPLICATION NOTES Components required to meet datasheet specifications - 5V output types Components required to meet datasheet specifications - 12V output types 3FUSE C2 C3 D1 L1 L2 12 +Vout -Vout AC (L) AC (N) MOV FUSE 1W 10Ω fusible resistor MOV Component fitted for compliance with EN61000-4-5, Installation class 3, perf criteria A L1 330μH C1 6.8μF 400V C2 68μF 20mΩ low ESR polymer L2 6.8μH 84682C C3 22μF D1 SMBJ7.0A transient voltage suppressor - component fitted for overshoot protection 3FUSE C2 D1 12 +Vout -Vout AC (L) AC (N) MOV FUSE 1W 10Ω fusible resistor MOV Component fitted for compliance with EN61000-4-5, Installation class 3, perf criteria A L1 330μH C1 6.8μF 400V C2 68μF 20mΩ low ESR polymer D1 SMBJ20A transient voltage suppressor - component fitted for overshoot protection

Isolated 1W Regulated Single Output AC/DC Converters KAC_BAC1C.C01 Page 6 of 14 www.murata.com APPLICATION NOTES (Continued) Components required to meet datasheet specifications - 24V output types Advisory Notes The BAC1 series is not hermetically sealed, customers should ensure that parts are fully dried before input power application. Output Capacitance and start-up times The recommended specified caps on page 4 and 5 can already meet datasheet specification, there is no need to add extra caps. However, if customers connects to load capacitance, the below load capacitance are max (additional to recommended specified caps) to ensure start up at minimum AC input. Minimum Load The minimum load to meet full datasheet specification is 5% of the full rated load across the specified input voltage range. 24V output type - minimum input voltage requirements At -40C the part is guaranteed to start into 100% load with a minimum input voltage of 115Vac; once the product is operating, the product will continue to operate at lower input voltages with higher output loading. The product will start at -40C with 80% or lower load with an input voltage of 100VAC; once the product is operating, the product will continue to operate at lower input voltages with higher output loading. 3FUSE C2 D1 12 +Vout -Vout AC (L) AC (N) MOV FUSE 1W 10Ω fusible resistor MOV Component fitted for compliance with EN61000-4-5, Installation class 3, perf criteria A L1 330μH C1 6.8μF 400V C2 47μF 25mΩ low ESR polymer D1 SMBJ30A transient voltage suppressor - component fitted for overshoot protection Part No. Maximum Load Capacitance (per output) Start-up times (AC input) Start-up times (DC input) μF s s BAC1S05SC 220 0.5 5 BAC1S12SC 100 1 5 BAC1S24SC 100 1 5

Isolated 1W Regulated Single Output AC/DC Converters KAC_BAC1C.C01 Page 7 of 14 www.murata.com Oscilloscope 10μF Load -Vout +Vout BAC1SXXSC Twisted wire: #20AWG-30cm CHARACTERISATION TEST METHODS Ripple & Noise Characterisation Method Ripple and noise measurements are performed with the following test configuration. C1 10μF electrolytic capacitor Differential Mode Noise Test Schematic EFFIECIENCY VS LOAD BAC1S05DC BAC1S12DC BAC1S24DC 0 1 02 03 04 05 06 07 08 09 0 1 0 0 Efficiency (%) Load (%) 85V 115V 230V 264V 277V 305V 0 1 02 03 04 05 06 07 08 09 0 1 0 0 Efficiency (%) Load (%) 85V 115V 230V 264V 277V 305V 0 1 02 03 04 05 06 07 08 09 0 1 0 0 Efficiency (%) Load (%) 85V 115V 230V 264V 277V 305V

Isolated 1W Regulated Single Output AC/DC Converters KAC_BAC1C.C01 Page 8 of 14 www.murata.com TEMPERATURE DERATING BAC1S05DC BAC1S12DC BAC1S24DC 100 - 4 0 - 3 0 - 2 0 - 1 00 1 02 03 04 05 06 07 08 0 Load (%) Temperature (°C) 85VAC 115VAC 230VAC 277VAC 305VAC 100 - 4 0 - 3 0 - 2 0 - 1 00 1 02 03 04 05 06 07 08 0 Load (%) Temperature (°C) 85VAC 115VAC 230VAC 277VAC 305VAC 100 - 4 0 - 3 0 - 2 0 - 1 00 1 02 03 04 05 06 07 08 0 Load (%) Temperature (°C) 85VAC 115VAC 230VAC 277VAC 305VAC

Isolated 1W Regulated Single Output AC/DC Converters KAC_BAC1C.C01 Page 9 of 14 www.murata.com EMC FILTERING AND SPECTRA FILTERING BAC1S05SC (110V) - Live BAC1S05SC (110V) - Neutral BAC1S12SC (110V) - Live BAC1S12SC (110V) - Neutral The following filter circuit and filter table shows the input filters typically required to meet EN55032 Quasi-Peak (green line) Curve B limit vs peak conducted emisions. L1* 12 +Vout -Vout AC (L) AC (N) 5V and 12V output types Component Description C1 68nF 305VAC L1 refer to “components required to match datasheet specifications” C2 100pF Y-cap Components marked with an asterisk are already fitted and should not be duplicated

Isolated 1W Regulated Single Output AC/DC Converters KAC_BAC1C.C01 Page 10 of 14 www.murata.com EMC FILTERING AND SPECTRA (Continued) BAC1S05SC (230V) - Live BAC1S05SC (230V) - Neutral BAC1S12SC (230V) - Live BAC1S12SC (230V) - Neutral

Isolated 1W Regulated Single Output AC/DC Converters KAC_BAC1C.C01 Page 11 of 14 www.murata.com EMC FILTERING AND SPECTRA (Continued) FILTERING BAC1S24SC (110V) - Live BAC1S24SC (110V) - Neutral BAC1S24SC (230V) - Live BAC1S24SC (230V) - Neutral L1* 12 +Vout -Vout AC (L) AC (N) L2C3* BAC1S24SC Component Description C1 68nF 305VAC L1 refer to “components required to match datasheet specifications” C2 100pF Y-cap C3 refer to “components required to match datasheet specifications” L2 DLW21SN261SQ2L Components marked with an asterisk are already fitted and should not be duplicated The following filter circuit and filter table shows the input filters typically required to meet EN55032 Quasi-Peak (green line) Curve B peak conducted emisions.

Isolated 1W Regulated Single Output AC/DC Converters KAC_BAC1C.C01 Page 12 of 14 www.murata.com PACKAGE SPECIFICATIONS MECHANICAL DIMENSIONS PIN CONNECTIONS Pin Output Pin Function

1 AC( N)

3 AC (L)

5 +Vin (DC) 7 -Vin (DC) 10 -Vout 12 +Vout RECOMMENDED FOOTPRINT DETAILS Weight:6.2g 1 357 1 0 1 2 All dimensions in mm (inches) Controlling dimension is mm. All pins on a 2.54 (0. l 00) pitch and within ±0. l (0.004) of true position from pin l at seating plane ‘S’ The isolation barrier shown must not have any copper traces even on internal layers. This is to avoid compromising the creepage and clearnace distance. PCB layouts must take into consideration the required clearance and creepage requirements to maintain the clearance and creepage of the isolation barrier. All dimensions in mm (inches).

Isolated 1W Regulated Single Output AC/DC Converters KAC_BAC1C.C01 Page 13 of 14 www.murata.com PACKAGING SPECIFICATIONS (Continued) TRAY OUTLINE DIMENSIONS EPE Tray/Lid Quantity: 35 All dimensions in mm (inches) Controlling dimension is mm. 12.992 ±0.039 330.0 ±1.0 330.0 ±1.0 12.992 ±0.039 35.0 ±2.0 1.378 ±0.079

Isolated 1W Regulated Single Output AC/DC Converters KAC_BAC1C.C01 Page 14 of 14 www.murata-ps.com/support Murata Power Solutions (Milton Keynes) Ltd. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2021 Murata Power Solutions (Milton Keynes) Ltd. This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: http://www.murata-ps.com/requirements/ DISCLAIMER Unless otherwise stated in the datasheet, all products are designed for standard commercial and industrial applications and NOT for safety-critical and/or life-critical applications. Particularly for safety-critical and/or life-critical applications, i.e. applications that may directly endanger or cause the loss of life, inflict bodily harm and/or loss or severe damage to equipment/property, and severely harm the environment, a prior explicit written approval from Murata is strictly required. Any use of Murata standard prod- ucts for any safety-critical, life-critical or any related applications without any prior explicit written approval from Murata shall be deemed unauthorised use. These applications include but are not limited to:

  • Aircraft equipment
  • Aerospace equipment
  • Undersea equipment
  • Power plant control equipment
  • Medical equipment
  • Transportation equipment ( automobiles, trains, ships, etc.)
  • Traffic signal equipment
  • Disaster prevention / crime prevention equipment
  • Data Processing equipment Murata makes no express or implied warranty, representation, or guarantee of suitability, fitness for any particular use/purpose and/or compatibility with any applica- tion or device of the buyer, nor does Murata assume any liability whatsoever arising out of unauthorised use of any Murata product for the application of the buyer. The suitability, fitness for any particular use/purpose and/or compatibility of Murata product with any application or device of the buyer remain to be the responsibility and liability of the buyer. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards that anticipate dangerous consequences of failures, moni- tor failures and their consequences, lessen the likelihood of failures that might cause harm, and take appropriate remedial actions. Buyer will fully indemnify and hold Murata, its affiliated companies, and its representatives harmless against any damages arising out of unauthorised use of any Murata products in any safety-critical and/ or life-critical applications. Remark: Murata in this section refers to Murata Manufacturing Company and its affiliated companies worldwide including, but not limited to, Murata Power Solutions.