Carling Technologies, Inc.

60 Johnson Avenue • Plainville, CT 06062

Phone: (860) 793-9281 • Fax: (860) 793-9231 Email: sales@carlingtech.com • www.carlingtech.com The B-Series hydraulic/magnetic circuit breakers are compact and temperature stable designed for precision operation in OEM markets requiring general purpose as well as full load amp applications. These circuit breakers are designed specifically for world market applications requiring extra insulation and tongue & groove half- shell constructions. Actuators available include handle for 1- 6 poles, rocker for 1-3 poles, and Visi-Rocker for 1-3 poles construction. They are also offered with ratings from 0.02 to 50 amps and up to 277VAC or 80VDC, with choices of time delays, terminals, wide range of standard colors, imprinting. Additional Features: Š UL489 approvals available Š Extra insulation and tongue & groove half-shell constructions Applications: Š Power Supplies Š Medical Equipment Š Generator & Welder Markets Š Office Equipment Š Control Panels Š Marine Š Military Agency Certifications: Š UL Recognized – UL Standard 508, 1077, 1500 Š UL Listed – UL Standard 489, 489A Š CSA Accepted Š TUV Certified Š VDE Certified

1 POLE

2 POLE

60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231

Email: sales @carlingtech.com • www.carlingtech.com 2 | B-Series Circuit Breaker - General Specifications *Manufacturer reserves the right to change product specification without prior notice. Mechanical Physical Environmental Electrical Pulse Tolerance Curves Designed and tested in accordance with requirements of specification MIL-PRF-55629 & MIL-STD-202 as follows: RESISTANCE PER POLE VALUES from Line to Load Terminals (Values Based on Series Trip Circuit Breaker) Maximum Voltage 277VAC 50/60 Hz, 80VDC Current Ratings Standard current coils: 0.100, Other ratings available, see ordering scheme. Standard Voltage Coils DC - 6V, 12V; AC - 120V, other ratings available, see ordering scheme. Auxiliary Switch Rating SPDT; 10.1 AMPS - 250VAC,1.0A 65 VDC or 0.5A 80 VDC, 0.1 Amps - 125VAC (with gold contacts). VDE-1.0 Amp - 125VAC. Insulation Resistance Minimum of 100 Megohms at 500 VDC. Dielectric Strength UL, CSA-1500 V 50/60 Hz for one minute between all electrically isolated terminals. B-Series circuit breakers comply with the 8mm spacing and 3750V 50/60 Hz dielectric requirements from hazardous voltage to operator accessible surfaces, between adjacent poles and from main circuits to auxiliary circuits per Publications EN 60950 and VDE 0805. Resistance, Impedance Values from Line to Load Terminal - based on Series Trip Circuit Breaker. Endurance 10,000 ON-OFF operations @ 6 per minute; with rated Current and Voltage. Trip Free All B-Series Circuit Breakers will trip on overload, even when Handle is forcibly held in the ON position. Trip Indication The operating Handle moves positively to the OFF position when an overload causes the breaker to trip. Number of Poles 1 - 6 poles at 30 Amps or less. 1 and 2 poles at 31 Amps thru 50 Amps. Internal Circuit Config. Series, (with or without auxiliary switch), Shunt and Relay with current or voltage trip coils, Dual Coil, Switch Only (with or without auxiliary switch). Weight Approximately 65 grams/pole. (Approximately 2.32 ounces/pole.) Standard Colors Housing- Black; Actuator - See Ordering Scheme. Shock Withstands 100 Gs, 6ms, sawtooth while carrying rated current per Method 213, Test Condition “I”. Instantaneous and ultra-short curves tested @ 90% of rated current. Vibration Withstands 0.060” excursion from 10-55 Hz, and 10 Gs 55-500 Hz, at rated current per Method 204C, Test Condition A. Instantaneous and ultrashort curves tested at 90% of rated current. Moisture Resistance Method 106D, i.e., ten 24-hour cycles @ + 25°C to +65°C, 80-98% RH. Salt Spray Method 101, Condition A (90-95% RH @ 5% NaCl Solution, 96 hrs). Thermal Shock Method 107D, Condition A (Five cycles @ -55°C to +25°C to +85°C to +25°C). Operating Temperature -40° C to +85° C

Email: sales @carlingtech.com • www.carlingtech.com Email: sales @carlingtech.com • www.carlingtech.com | 3 B-Series Circuit Breaker - General Specifications Electrical Tables Table A: Lists UL Recognized & CSA Certified configurations and performance capabilities as a Component Supplementary Protector. Notes: 1 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (15A minimum) at no more than 4 times the rating of the protector. 2 Same as note 1, except that backup fuse is limited to 80A maximum. 3 2 pole protector required (with one pole per power line) for: 250/125 VAC, 125/250 VAC and 208Y/120 VAC Power Systems. 1 pole protector required for : 125 VAC, 1Ø Power System.

Email: sales @carlingtech.com • www.carlingtech.com 4 | B-Series Circuit Breaker - General Specifications Electrical Tables Table B: Lists UL Recognized, CSA, VDE & TUV Certified configurations & performance capabilities as a Component Supplementary Protector. Table C: Lists UL Recognized, CSA Certified configurations and performance capabilities as Protectors, Supplementary for Marine Marine in accordance with ISO 8846 (CCN/Guide UZMK, File MQ1515) as Marine Supplementary Protectors. Notes: 1 General Purpose Ratings for UL/CSA Only. 2 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (15A minimum) at no more than 4 times the rating of the protector. 3 Same as note 1, except that backup fuse is limited to 80 A maximum. Notes: 1 Available with special catalog number only (consult factory). 2 2 pole protector required (with one pole per power line) for: 250/125 VAC, 125/250 VAC and 208Y/120 VAC Power Systems. 1 pole protector required for : 125 VAC, 1Ø Power System.

Email: sales @carlingtech.com • www.carlingtech.com Email: sales @carlingtech.com • www.carlingtech.com | 5 B-Series Circuit Breaker - General Specifications Table D: Lists UL Listed configurations and performance capabilities as Circuit Breakers for use in Communications Equipment (CCN/ Guide DITT, File E189195), under UL489A Table E: Lists UL Listed (489) configuration and performance capabilities as a Molded Case Circuit Breaker. 120 50 / 60 1 0.10 - 30 5,000 1 Pole SERIES 120 / 240 50 / 60 1 0.10 - 30 5,000 2 Poles 120 / 240 50 / 60 1 0.10 - 30 5,000 2 or 3 Poles (1 Pole of a 3 Pole Unit is for Neutral Break) 120 50 / 60 1 0.10 - 30 5,000 1 Pole 120 / 240 50 / 60 1 0.10 - 30 5,000 2 Poles 120 / 240 50 / 60 1 0.10 - 30 5,000 2 or 3 Poles (1 Pole of a 3 Pole Unit is for Neutral Break) SHUNT TRIP DUAL COIL B SERIES TABLE E : UL489 LISTED BRANCH CIRCUIT BREAKERS VOLTAGE INTERRUPTING CAPACITY (AMPS) CONSTRUCTION NOTES MAX. RATING FREQUENCY PHASE WITHOUT BACKUP FUSE CIRCUIT CONFIGURATION FULL LOAD AMPS CURRENT RATING Notes:

1 Parallel Pole Construction

Component Recognition Program as Protectors Supplementary (Guide CCN/QVNU2, File E75596) Switches, Industrial Control (Guide CCN/NRNT2, File E148683) Protectors, Supplementary for Marine Electrical & Fuel Systems (Guide PEQZ2, File E75596) Ignition Protection Circuit Breakers, Molded Case, (Guide DIVQ, File E129899) Communications Equipment (Guide CCN/DITT, File E189195) Component Supplementary Protector under Class 3215 30, FIle 047848 0 000 CSA Standard C22.2 No. 235 EN60934, under License No. R72040875 EN60934, VDE 0642 under File No. 10537

Email: sales @carlingtech.com • www.carlingtech.com 6 | B-Series Handle UL Recognized – Ordering Scheme Series Actuator Poles Aux/Alarm Switch Frequency & Delay Current Rating Terminal Actuator Color Mounting/ Barriers Agency Approval Circuit B A B 1 13 0 B C10 450

1 SERIES

B

2 ACTUATOR

A Handle, one per pole B Handle, one per multipole unit S Mid-Trip Handle, one per pole T Mid-Trip Handle, one per pole & Alarm Switch

8 TERMINAL9

110 Push-On 0.250 Tab (Q.C.)

2 Screw 8-32 w/upturned lugs

311 Screw 8-32 (Bus Type)

4 Screw 10-32 w/upturned lugs

511 Screw 10-32 (Bus Type)

6 Screw 8-32 w/upturned lugs

and 30° bend

7 Screw 8-32 (Bus Type) and

30° bend

8 Screw 10-32 w/upturned lugs

and 30° bend

9 Screw 10-32 (Bus Type) and

30° bend B Screw M5 w/upturned lugs C Screw M4 w/upturned lugs E11 Screw M4 (Bus Type) F Screw M5 w/upturned lugs and 30° bend G Screw M5 (Bus Type) and 30° bend H Screw M5 (Bus Type) J Screw M5 Back Connect K Screw 10-32 Back Connect L12 0.250 Q.C./ Solder Lug M11 M6 Threaded Stud N Screw M4 Back Connect P13 Printed Circuit Board Terminals Q16 Push-In Stud R Screw M4 w/upturned lugs and 30° bend S15 Push-On 0.110 Tab (Q.C.) T Screw M4 (Bus Type) and 30° bend Y Screw 8-32 Back Connect

10 MOUNTING/BARRIERS

Threaded Insert, 2 per pole 1 6-32 x 0.195 inches no A 6-32 x 0.195 inches (multi-pole units only) yes

2 ISO M3 x 5mm no

Rectangular Adapter Plate with mounting centers of 2.062 inches [52.37mm] and Threaded insert, 2 per pole 314 6-32 x 0.225 inches no C14 6-32 X 0.225 inches (multi-pole units only) yes 414 ISO M3 x 6.5mm no D14 ISO M3 x 6.5mm yes Front panel Snap-In, 0.75” [19.05mm] wide bezel 5 without Handleguard no 6 without Handleguard (multipole only) yes Front panel Snap-In, 0.96” wide bezel 7 without Handleguard, 1-pole 0.96” wide; no multipole units have .105” bezel overhang on all sides 8 without Handleguard, 1-pole 0.96” wide; yes (multipole only) .105” bezel overhang on all sides

3 POLES

1 One

2 Two

3 Three

4 Four

5 Five

6 Six

5 AUXILIARY/ALARM SWITCH 5

(Gold Contacts) (Gold Contacts) (Gold Contacts)

6 FREQUENCY & DELAY

032 DC 50/60Hz, Switch Only

106 DC Instantaneous

11 DC Ultra Short

12 DC Short

14 DC Medium

16 DC Long

30 DC, 50/60Hz Instantaneous

31 DC, 50/60Hz Ultra Short

32 DC, 50/60Hz Short

34 DC, 50/60Hz Medium

36 DC, 50/60Hz Long

427 50/60Hz Short, Hi-Inrush 447 50/60Hz Medium, Hi-Inrush 467 50/60Hz Long, Hi-Inrush

527 DC, Short,Hi-Inrush

547 DC, Medium, Hi-Inrush

567 DC, Long, Hi-Inrush

7 CURRENT RATING (AMPERES)

OR VOLTAGE COIL (NORMAL RATED VOLTAGE)6 020 0.020 025 0.025 030 0.030 035 0.035 040 0.040 045 0.045 050 0.050 055 0.055 060 0.060 065 0.065 070 0.070 075 0.075 080 0.080 085 0.085 090 0.090 095 0.095 210 0.100 215 0.150 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 410 1.000 512 1.250 415 1.500 517 1.750 420 2.000 522 2.250 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 485 8.500 490 9.000 495 9.500 610 10.000 710 10.500 611 11.000 711 11.500 612 12.000 712 12.500 613 13.000 614 14.000 615 15.000 616 16.000 617 17.000 618 18.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 6358 35.000 6408 40.000 6458 45.000 6508 50.000 CODE AMPERES A06 6 DC A12 12 DC A18 18 DC A24 24 DC A32 32 DC A48 48 DC A65 65 DC J06 6 AC J12 12 AC J18 18 AC J24 24 AC J48 48 AC J65 65 AC K20 120 AC L40 240 AC

11 AGENCY APPROVAL

C UL Recognized & CSA Accepted D VDE Certified, UL Recognized & CSA Accepted E TUV Certified, UL Recognized & CSA Accepted I UL Rec. STD 1077, UL Rec. 1500 (ignition protected), & CSA Accepted

9 ACTUATOR COLOR & LEGEND

Actuator Color I-O ON-OFF Dual Legend Color White A B 1 Black Black C D 2 White Red F G 3 White Green H J 4 White Blue K L 5 White Yellow M N 6 Black Gray P Q 7 Black Orange R S 8 Black Notes:

1 Actuator Code:

A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units. B: Handle location as viewed from front of breaker: 2 pole - left pole 3 pole - center pole 4 pole - two handles at center poles 5 pole - three handles at center poles 6 pole - four handles at center poles S: Handle moves to mid-position only upon electrical trip of the breaker. Available with circuit codes B, C, D, E, F, G, H and K. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. Available with circuit codes B & C.

2 Switch Only circuits, rated up to 50 amps and 6 poles, and only available with VDE

Certification when tied to a protected pole (Circuit Code B, C, D or H.), For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. 3 Available with Terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum. 4 Consult factory for available Dual Coil options, as special catalog number is required. With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require 30VA minimum power to trip and are rated for intermittent duty only. 5 Auxiliary Switch breakers with Series Trip and Switch Only circuits. On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole. 6 Separate pole type voltage coils not rated for continuous duty. Available only with delay codes 10 and 20. 7 Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized and CSA Accepted to 50 amps. 8 VDE Certification available with single pole breakers with DC Delay only. UL Recognition and CSA Accepted available in one and two pole breakers. 9 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G, H, J, K, M and Q.

10 VDE Certification up to 25 amps and UL Recognition and CSA Acceptance up to 30 amps,

but not recommended over 20 amps.

11 Terminal Codes 3, 5 E and H (Bus Type) with VDE, are supplied with Lock Washers, and

Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only VDE Certified when the washers are used. 12 VDE Cert. available up to 12 amps. UL Rec. & CSA Acceptance available up to 30 amps.

13 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30

amps with VDE Certification and 50 amps with UL Recognition and CSA Acceptance, with Circuit Codes A, B and C. Two pole breakers with Terminal Code P (Printed Circuit Board) are available up to 40 amps with UL Recognition and CSA Acceptance with Circuit Codes A, B and C. 14 Available with Actuator Codes A, S and T. 15 Available with voltage coils only. 16 Terminal Code Q not available with VDE approvals.

4 CIRCUIT

A2 Switch Only (No Coil) B Series Trip (Current) C Series Trip (Voltage) D3 Shunt Trip (Current) E3 Shunt Trip (Voltage) F3 Relay Trip (Current) G3 Relay Trip (Voltage) H3,4 Dual Coil with Shunt Trip Voltage Coil H3,4 Dual Coil with Shunt Trip Voltage Coil (side terminal) K3,4 Dual Coil with Relay Trip Voltage Coil

Email: sales @carlingtech.com • www.carlingtech.com Email: sales @carlingtech.com • www.carlingtech.com | 7 B-Series Handle UL489A – Ordering Scheme Series Actuator Poles Aux/Alarm Switch Frequency & Delay Current Rating Terminal Actuator Color Mounting/ Barriers Max. Appl. Rating Agency Approval Circuit B A B 1 11 0 B M T14 450 B

2 ACTUATOR1

A Handle, one per pole B Handle, one per multipole unit S Mid-Trip Handle, one per pole T Mid-Trip Handle, one per pole & Alarm Switch

8 TERMINAL4

15 Push-On 0.250 Tab (Q.C.)

36 Screw 8-32 (Bus Type)

56 Screw 10-32 (Bus Type)

and 30° bend 30° bend and 30° bend 30° bend B Screw M5 w/upturned lugs F Screw M5 w/upturned lugs and 30° bend G Screw M5 (Bus Type) and 30° bend H Screw M5 (Bus Type) J Screw M5 Back Connect K Screw 10-32 Back Connect M6 M6 Threaded Stud N Screw M4 Back Connect P7 Printed Circuit Board Terminals Q8 Push-In Stud Y Screw 8-32 Back Connect

3 POLES2

5 AUXILIARY/ALARM SWITCH 2

(Gold Contacts)

6 FREQUENCY & DELAY4

52 DC, Short,Hi-Inrush

54 DC, Medium, Hi-Inrush

56 DC, Long, Hi-Inrush

210 0.100 215 0.150 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 410 1.000 512 1.250 415 1.500 517 1.750 420 2.000 522 2.250 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 485 8.500 490 9.000 495 9.500 610 10.000 710 10.500 611 11.000 711 11.500 612 12.000 712 12.500 613 13.000 614 14.000 615 15.000 616 16.000 617 17.000 618 18.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 6353 35.000 6403 40.000 6453 45.000 6503 50.000 CODE AMPERES

12 AGENCY APPROVAL

K UL489A LISTED, VDE CERTIFIED J UL489A LISTED, TUV CERTIFIED

11 MAXIMUM APPLICATION RATING

Actuator Color ON-OFF Dual Legend Color White B 1 Black Black D 2 White Red G 3 White Green J 4 White Blue L 5 White Yellow N 6 Black Gray Q 7 Black Orange S 8 Black Notes: A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units. S: Handle moves to mid-position only upon electrical trip of the breaker. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. 2 On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 3 VDE Certification available with single pole breakers only. UL489A Listing available with one and two pole breakers. 4 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G, H, J, K, M and Q.

5 Terminal Code 1 (Push-On) available up to 25 amps with TUV or VDE Certification and

30 amps with UL489A Listing, but is not recommended over 20 amps.

6 Terminal Codes 3, 5 and H (Bus Type) with TUV or VDE, are supplied with Lock Washers,

and Terminal Code M (M6 Threaded Stud) with TUV or VDE is supplied with Lock and Flat Washers. These breakers are only TUV or VDE Certified when the washers are used.

7 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30

amps with VDE Certification and 50 amps with UL489A Listing. 8 Terminal Code Q not available with VDE approvals. B Series Trip (Current) Threaded Insert, 2 per pole 1 6-32 x 0.195 inches no A 6-32 x 0.195 inches (multi-pole units only) yes Rectangular Adapter Plate with mounting centers of 2.062 inches [52.37mm] and Threaded insert, 2 per pole 3 6-32 x 0.225 inches no C 6-32 X 0.225 inches (multi-pole units only) yes 4 ISO M3 x 6.5mm no D ISO M3 x 6.5mm yes Front panel Snap-In, 0.75” [19.05mm] wide bezel 5 without Handleguard no 6 without Handleguard (multipole only) yes Front panel Snap-In, 0.96” wide bezel 7 without Handleguard, 1-pole 0.96” wide; no multipole units have .105” bezel overhang on all sides 8 without Handleguard, 1-pole 0.96” wide; yes (multipole only) .105” bezel overhang on all sides

Email: sales @carlingtech.com • www.carlingtech.com 8 | B-Series Handle UL489 Listed – Ordering Scheme Series Actuator Poles Aux/Alarm Switch Frequency & Delay Current Rating Terminal Actuator Color Mounting/ Barriers Max. Appl. Rating Agency Approval Circuit B A B 1 A1 0 B K G24 450 B A Handle, one per pole B Handle, one per multipole unit S Mid-Trip Handle, one per pole T Mid-Trip Handle, one per pole & Alarm Switch

8 TERMINAL5

1 Push-On 0.250 Tab (Q.C.)

3 Screw 8-32 (Bus Type)

5 Screw 10-32 (Bus Type)

and 30° bend 30° bend and 30° bend 30° bend A Load Terminal: #8 Screw/QC Combination. (Special Cat.#) B Screw M5 w/upturned lugs C Screw M4 w/upturned lugs E Screw M4 (Bus Type) F Screw M5 w/upturned lugs and 30° bend G Screw M5 (Bus Type) and 30° bend H Screw M5 (Bus Type) J Screw M5 Back Connect K Screw 10-32 Back Connect M M6 Threaded Stud N Screw M4 Back Connect Q Push-In Stud Y Screw 8-32 Back Connect

1 One 2 Two 33 Three

5 AUXILIARY/ALARM SWITCH 4

21 AC Ultra Short

22 AC Short

24 AC Medium

26 AC Long

42 AC, Short,Hi-Inrush

44 AC, Medium, Hi-Inrush

46 AC, Long, Hi-Inrush

210 0.100 215 0.150 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 410 1.000 512 1.250 415 1.500 517 1.750 420 2.000 522 2.250 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 485 8.500 490 9.000 495 9.500 610 10.000 710 10.500 611 11.000 711 11.500 612 12.000 712 12.500 613 13.000 614 14.000 615 15.000 616 16.000 617 17.000 618 18.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 CODE AMPERES

3 UL489 Listed, TUV Certified

9 ACTUATOR COLOR & LEGEND6

Actuator Color ON-OFF Dual Legend Color White B 1 Black Black D 2 White Red G 3 White Green J 4 White Blue L 5 White Yellow N 6 Black Gray Q 7 Black Orange S 8 Black Notes: A: Handle tie pin spacer(s) and retainers provided un-assembled with multi-pole units. B: Handle location as viewed from front of breaker: 2 pole - left pole 3 pole - center pole S: Handle moves to mid-position only upon electrical trip of the breaker. Available with circuit codes B, C, D, E, F, G, H and K. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. Available with circuit codes B & C. 2 All poles must be same polarity. 3 3 pole units available only when 1 of 3 poles is neutral. 4 Auxiliary/Alarm Switch circuit must be same polarity as the main circuit. On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole. 5 Screw Terminals are recommended on ratings greater than 20 amps. 6 Standard actuator colors are black and white. 7 Adapter plate with mounting centers of 2.082 inches. Available with Actuator Codes A, S and T. 8 Voltage Rating available with 2 and 3-pole breakers only. 9 Barriers supplied on multi-pole units only. B Series Trip (Current) Threaded Insert, 2 per pole A 6-32 x 0.195 inches (multi-pole units only) yes B ISO M3 x 5mm yes Rectangular Adapter Plate with mounting centers of 2.062 inches [52.37mm] and Threaded insert, 2 per pole7 C 6-32 X 0.225 inches (multi-pole units only) yes D ISO M3 x 6.5mm yes Front panel Snap-In, 0.75” [19.05mm] wide bezel 6 without Handleguard (multipole only) yes Front panel Snap-In, 0.96” wide bezel 8 without Handleguard, 1-pole 0.96” wide; yes (multipole only) .105” bezel overhang on all sides

Email: sales @carlingtech.com • www.carlingtech.com Email: sales @carlingtech.com • www.carlingtech.com | 9 B-Series Handle – Circuit & Terminal Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. A A D E F G CIRCUIT CODE C C ALARM SWITCH MODE C HANDLE POSITION VS. AUX/ALARM SWITCH MODE RELAY TRIP (4 TERM'S.) NOO 30° NC C O NONC NO NO ON NC ELECTRICAL TRIP 30° OOFF I ON 30° NC C NONC 90° MID TRIP 30° NCC ON I NO AUX. SWITCH MODE CIRCUIT BREAKER MODE OFF OFF HANDLE POSITION STANDARD C/B .390 [9.91] .780 [19.81] 30° OFF MID TRIP C/B HANDLE POSITION RELAY (RELAIS) I > LOAD (LAST) LOAD RELAY RELAY RELAY (RELAIS) (3)LINE (NETZ) LINE SERIES TRIP W AUX SWITCH (5 TERM'S.) SERIES TRIP (2 TERM'S.) SHUNT TRIP (3 TERM'S.) C C .390 [9.91] NO NC AUX. SWITCH TERM'S. RELAY TRIP LOAD (LAST)LOAD I > LOAD (LAST) SHUNT (NEBENSCHLUSS) LINE (NETZ) (3) NC LINE LOAD NO SHUNT TRIP SHUNT NC NO .520 [13.21] C 1.730 [43.94] MAIN TERM'S. (SEE TABLE A) SWITC H ONLY (NO COIL) WITH AUXILIARY SWITC H LINE (NETZ)LINE LOAD (LAST) IEC LINE (NETZ) LOAD ANSI LINE SWITC H ONLY (NO COIL) CIRCUIT SCHEMATIC O CNC NO MID TRIP 90° 30° ON I CNONC CNONC VOLTAGE COIL VOLTAGE COIL 30° AUX. SWITCH MODE (w/o ALARM SWITCH) OFF MID TRIP C/B HANDLE POSITION LINE (NETZ) VOLTAGE COIL LOAD (LAST) I > LINE LOAD K U > DUAL COIL; SERIES TRIP CURRENT COIL, RELAY TRIP VOLTAGE COIL VOLTAGE COIL LINE (NETZ) LOAD (LAST) ALARM SWITCH DUAL COIL; SERIES TRIP CURRENT COIL, SHUNT TRIP VOLTAGE COIL VOLTAGE COIL I > LOAD (LAST)LOAD NO NC I > LOAD ALARM SWITCH LINE U > NO B C H NC LOAD (LAST) LINE (3) (NETZ) LINE (NETZ) (3) STD. AUX. SWITCH SERIES TRIP WITH AUXILIARY / ALARM SWITC H CIRCUIT SCHEMATIC AUX SWITCH CODE LINE STD. AUX. SWITCH C SERIES TRIP IEC LINE LOAD ANSI I > O C B C O AUX SWITCH CODE CIRCUIT CODE

Email: sales @carlingtech.com • www.carlingtech.com 10 | B-Series Handle – Circuit & Terminal Diagrams

2 PLCS

30° 12-15 IN-LBS [1.4-1.7 NM] 15-20 IN-LBS [1.7-2.3 NM] 1.000 [25.40] .392 [9.97] TORQUE .154 [3.91] DIA 7-9 IN-LBS [0.8-1.0 NM] * AVAILABLE ON SERIES TRIP AND SWITCH ONLY CIRCUITS. WHEN CALLED FOR ON MULTI-POLE UNITS, ONLY ONE AUX. SWITCH IS NORMALLY SUPPLIED, AS SHOWN IN MULTI-POLE IDENTIFICATION SCHEME. TABLE A TIGHTENING TORQUE SPECIFICATIONS 1.560 [39.62] DEPTH BEHIND PANEL CENTERLINE OF PUSH-IN STUD CONTACT AREA SCREW TERMINAL WITH 30° BEND BARRIER FOR UL-489 MULTI-POLE BREAKERS BARRIER FOR UL-RECOGNIZED MULTI-POLE BREAKERS OFF O ON I MID TRIP 1.560 [39.62] TYP .220 [5.59] TYP TYP .032 [.81] LOAD (LAST) SEE TABLE-B DEPTH BEHIND PANEL LINE (NETZ) BACK CONNECT SCREW TERMINAL WITH RETAINER 1.250 [31.75] BACK CONNECT SCREW TERMINAL PUSH-IN STUD 1.936[49.17] M6 STUD 1.350 [34.29] .393 [9.96] REF .392[9.96] .093DIA [.76] .087 [2.20] .287 [7.29] 1.313 [33.35] TAB (Q.C.) .051 DIA[Ø1.29] AUXILIARY SWITCH TERMINAL DETAIL TERMINAL DIMENSIONAL DETAIL & RATING .161 DIA [Ø 4.10] PUSH-IN STUD MATING HOLE 2.230 [56.64] TYP .875 [22.23] REF LINE LOAD .069[1.75] DIA .360[9.14] TAB (Q.C.)

30 AMP

#8-32 30 AMP #10-32 30 AMP M5 30 AMP M4 30 AMP +.002 [+.05] -.000 [-.00] UPTURN LUG BUS #8-32 30 AMP #10-32 50 AMP .392[9.96] .070 DIA [Ø1.80] LINE LOAD 2.000 [50.80] .126 [3.20] .520 [13.21] SOLDER TYPE TERMINAL DESCRIPTION SHUNT, RELAY DUAL COIL AUX. SWITCH* MAIN SCREW #8-32 W/UPTURNED LUGS TAB (Q.C.) .110 x .020 TAB (Q.C.) SCREW TYPE SOLDER TYPE TAB (Q.C.) THREAD SIZE #6-32 & M3 MOUNTING HARDWARE #8-32 & M4 THREAD TERMINAL SCREW #10-32 & M5 THREAD TERMINAL SCREW TABLE B M6 STUD

50 AMP

#8-32 30 AMP #10-32 50 AMP M5 50 AMP M4 30 AMP QC SOLDER LUG .205 [5.21] .344[8.74] .405[10.29] .750 [19.05] .100 [2.54] PUSH-IN STUD .750[19.05] TYP 2.612 [66.35] 2.644 [67.16] 2.537 [64.44] 2.348 [59.64] 2.090 [53.09] 2.122 [53.90] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified.

Email: sales @carlingtech.com • www.carlingtech.com Email: sales @carlingtech.com • www.carlingtech.com | 11 B-Series Handle – Front Panel Snap-In Mounting Style 5 Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ± 0.20 [.51] unless otherwise specified.

Email: sales @carlingtech.com • www.carlingtech.com 12 | B-Series Handle – Form & Fit Drawings Notes: 1 All dimensions are in inches [millimeters]. 3 Tolerance ±.020 [.51] unless otherwise specified.

Email: sales @carlingtech.com • www.carlingtech.com Email: sales @carlingtech.com • www.carlingtech.com | 13 B-Series Handle – Form & Fit Drawings Notes: 1 All dimensions are in inches [millimeters]. 3 Tolerance ±.020 [.51] unless otherwise specified.

Email: sales @carlingtech.com • www.carlingtech.com 14 | B-Series Rocker UL489 Listed – Ordering Scheme Series Actuator Poles Aux/Alarm Switch Frequency & Delay Current Rating Terminal Actuator Color Mounting/ Barriers Max. Appl. Rating Agency Approval Circuit B F B 2 A1 0 3 K G24 630 B (Gold Contacts) 210 0.100 215 0.150 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 410 1.000 512 1.250 415 1.500 517 1.750 420 2.000 522 2.250 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 485 8.500 490 9.000 495 9.500 610 10.000 710 10.500 611 11.000 711 11.500 612 12.000 712 12.500 613 13.000 614 14.000 615 15.000 616 16.000 617 17.000 618 18.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 CODE AMPERES Notes: 1 Multi-pole breakers have all breakers identical except when specifying Aux. switch and/or mixed poles, and have one rocker per breaker. 2 All poles must be same polarity. 3 3 pole units available only when1 of 3 poles is neutral. 4 On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole. 5 Screw Terminals are recommended on ratings greater than 20 amps.

6 Terminal Code 1 (Push-On) available up to 30 amps, but are not recommended over

20 amps.

7 Dual legend = ON-OFF/I-O

8 Voltage Rating available with 2 and 3-pole breakers only. 9 Barriers supplied on multi-pole units only. B Series Trip (Current) Threaded Insert, 2 per pole A 6-32 x 0.195 inches (multi-pole units only) yes B ISO M3 x 5mm yes ROCKERGUARD BEZEL Threaded Insert, 2 per pole C 6-32 X 0.225 inches (multi-pole units only) yes D ISO M3 x 6.5mm yes C Indicate ON, vertical legend D Indicate ON, horizontal legend F Indicate OFF, vertical legend G Indicate OFF, horizontal legend Single color J Vertical legend K Horizontal legend

3 POLES1,2

Actuator or Marking: Marking Color Visi-Color7 I-O ON-OFF Dual7 Single Color Visi-Rocker White A B 1 Black White Black C D 2 White n/a Red F G 3 White Red Green H J 4 White Green Blue K L 5 White Blue Yellow M N 6 Black Yellow Gray P Q 7 Black Gray Orange R S 8 Black Orange 16 Push-On 0.250 Tab (Q.C.) and 30° bend 30° bend and 30° bend 30° bend B Screw M5 w/upturned lugs C Screw M4 w/upturned lugs F Screw M5 w/upturned lugs and 30° bend G Screw M5 (Bus Type) and 30° bend H Screw M5 (Bus Type) J Screw M5 Back Connect K Screw 10-32 Back Connect N Screw M4 Back Connect Y Screw 8-32 Back Connect

Email: sales @carlingtech.com • www.carlingtech.com Email: sales @carlingtech.com • www.carlingtech.com | 15 B-Series Flat Rocker UL489 Listed – Ordering Scheme Series Actuator Poles Aux/Alarm Switch Frequency & Delay Current Rating Terminal Actuator Color Mounting/ Barriers Max. Appl. Rating Agency Approval Circuit B 1 B 2 A1 0 3 K G24 630 B

8 TERMINAL6

17 Push-On 0.250 Tab (Q.C.) and 30° bend 30° bend and 30° bend 30° bend B Screw M5 w/upturned lugs C Screw M4 w/upturned lugs F Screw M5 w/upturned lugs and 30° bend G Screw M5 (Bus Type) and 30° bend H Screw M5 (Bus Type) J Screw M5 Back Connect K Screw 10-32 Back Connect N Screw M4 Back Connect Y Screw 8-32 Back Connect

3 POLES2,3

1 One 2 Two 34 Three

(Gold Contacts) 210 0.100 215 0.150 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 410 1.000 512 1.250 415 1.500 517 1.750 420 2.000 522 2.250 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 485 8.500 490 9.000 495 9.500 610 10.000 710 10.500 611 11.000 711 11.500 612 12.000 712 12.500 613 13.000 614 14.000 615 15.000 616 16.000 617 17.000 618 18.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 CODE AMPERES Notes: 1 Push-To-Reset actuators have OFF portion of rocker shrouded. 2 Multi-pole breakers have all breakers identical except when specifying Aux. switch and/or mixed poles, and have one rocker per breaker. 3 All poles must be same polarity. 4 3 pole units available only when1 of 3 poles is neutral. 5 On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole. 6 Screw Terminals are recommended on ratings greater than 20 amps.

7 Terminal Code 1 (Push-On) available up to 30 amps, but are not recommended over

20 amps. 8 Color shown is visi and legend with remainder of rocker black, Dual = ON-OFF/I-O legend. 9 Legend on Push-to-reset bezel/shroud is white with single color actuator codes 7 & 8. Legend on Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator codes 5 & 6. 10 Recessed “off-side” available with actuator codes 1, 2, 3 & 4. Legends on rocker are available in ink stamping only. 11 Voltage rating available with 2 & 3-pole breakers only. 12 Barriers supplied on multi-pole units only. B Series Trip (Current)

10 MOUNTING/BARRIERS9

STANDARD ROCKER BEZEL,Threaded Insert, 2 per pole BARRIERS12 FLAT ROCKER ACTUATOR A 6-32 x 0.195 inches (multi-pole units only) yes B ISO M3 x 5mm yes RECESSED OFF SIDE ROCKER ACTUATOR10 E 6-32 X 0.225 inches (multi-pole units only) yes F ISO M3 x 6.5mm yes PUSH-TO-RESET BEZEL,Threaded Insert, 2 per pole C 6-32 x 0.195 inches yes D ISO M3 x 5mm yes

1 Indicate OFF, vertical legend

2 Indicate OFF, horizontal legend

3 Vertical legend

4 Horizontal legend

Push-To-Reset, Visi-Rocker

5 Indicate OFF,

6 Indicate OFF,

Push-To-Reset , Single color

7 Vertical legend

8 Horizontal legend

Actuator or Marking: Marking Color Visi-Color8 I-O ON-OFF Dual8 Single Color Visi-Rocker White A B 1 Black White Black C D 2 White n/a Red F G 3 White Red Green H J 4 White Green Blue K L 5 White Blue Yellow M N 6 Black Yellow Gray P Q 7 Black Gray Orange R S 8 Black Orange

Email: sales @carlingtech.com • www.carlingtech.com 16 | B-Series Rocker UL489 Listed – Form & Fit Drawings Notes: 1 Dimensions apply to all variations shown. Notice that circuit breaker line & load terminal orientation on indicate “OFF” is opposite of indicate “ON”. 2 For pole orientation with horizontal legend, rotate front view clockwise 90°. 3 All dimensions are in inches [millimeters]. 4 Tolerance ±.020 [.51] unless otherwise specified.

Email: sales @carlingtech.com • www.carlingtech.com Email: sales @carlingtech.com • www.carlingtech.com | 17 B-Series Flat Rocker UL489 Listed – Form & Fit Drawings Notes: 1 All dimensions are in inches [millimeters]. 2 For pole orientation with horizontal legend, rotate front view clockwise 90°. 3 Tolerance ±.020 [.51] unless otherwise specified.

Email: sales @carlingtech.com • www.carlingtech.com 18 | B-Series PC Terminal Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 For pole orientation with horizontal legend, rotate front view clockwise 90°. 3 Tolerance ±.010 [.25] unless otherwise specified. REV_CB_B_04_2014