Switching Spark Gap CAS04XG Ordering code: B88069X1200T502 Preliminary data AB E / AB PM Issue 03, 30.04.2002 Page 1 of 2 DC spark-over voltage 1) 2) 350 ... 550 V Impulse spark-over voltage at 100 V/µs - for 99 % of measured values - typical values of distribution at 1 kV/µs - for 99 % of measured values - typical values of distribution < 900 < 800 < 1200 < 1100 V V V V Insulation resistance at 300 Vdc > 1 GΩ Capacitance at 1 MHz < 1 pF Service life in customer circuit Unit must meet Insulation resistance DC spark-over voltage after 250, 500, 750 and 1000 h 1000 > 1 270 ... 650 h G Ω V Arc voltage at 1 A Glow to arc transition current Glow voltage ~ 10 < 100 ~ 60 V A V Weight ~ 1.5 g Operation and storage temperature -40 ... +90 °C Climatic category (IEC 60068-1) 40/ 90/ 21 Marking, red

400 YYMM O

1) At delivery AQL 0.65 level II, DIN ISO 2859 2) In ionized mode Terms in accordance with ITU-T Rec. K.12 and DIN 57845/VDE0845

Switching Spark Gap CAS04XG Ordering code: B88069X1200T502 Preliminary data  EPCOS AG 2002. Reproduction, publication and dissemination of this data sheet, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry recommended by the ZVEI (German Electrical and Electronic Manufacturers' Association), unless otherwise agreed. AB E / AB PM Issue 03, 30.04.2002 Page 2 of 2 Not to scale Dimensions in mm Non controlled document