Technical content
Series/Type: FS08X-1GH Ordering code: B88069X0340xxxx a) Version/Date: Issue 08 / 2006-08-30 Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the table and then change the color to "white" (or invisible). This ensures that the table disappears for the customer PDF. To update the data sheet, click on the symbol "Preview" and then "Close". Please do not alter the header or footer when copying the content. Identification/Classification 1: (header 1 + top left header bar) Switching spark gap Identification/Classification 2: (header 2 + bottom left header bar) SSG with lead wires Ordering code: (top right header bar) B88069X0340xxxx Series/Type: (top right header bar) FS08X-1GH Preliminary data (optional): (if necessary) Department: KB AB E / KB AB PM Date: Issue 08 / 2006-08-30 EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. EPCOS AG is a TDK Group Company.
Switching spark gap B88069X0340xxxx a) SSG with lead wires FS08X-1GH KB AB E / KB AB PM Issue 08 / 2006-08-30 Please read Cautions and warnings and Page 2 of 5 Important notes at the end of this document. Features Applications Extremely long life time Stable performance over life Insensitive performance against variations in temperature Very low switching losses Very short breakdown time High reliability by robust design RoHS compatibility Ignition of HID lamps Electrical specifications Nominal breakdown voltage VN 800 V Initial values 2) Static breakdown voltage V S 1) First ignition value V S, FTE after 24 hours in darkness Following ignition values V S, FIV 950 704 ... 896 V V Electrical life time 3) Breakdown voltage V B up to 100 000 Ignitions First ignition value V B, FTE after 24 hours in darkness Ignition time t I at V0 during life Following ignition values V B, FIV at 50 000 Ignitions Following ignition values V B, FIV 1000 60 704 ... 920 680 ... 920 V ms V V Switching operations in total at – 40; +150 °C, each at + 25; +125 °C, each 100 000 10 000 40 000 Ignitions Ignitions Ignitions Test circuit parameters Open circuit voltage V 0 Loading resistance R Discharge capacitance C Inductance L Discharge peak current I P 1000 114 0.13 ~ 660 V nF µH A General technical data Insulation resistance at 100 V Early ignition values between 530 ... 680 V Breakdown time Maximum loading current Weight > 100 1 50 ~ 2 ns mA g Marking, blue positive
800 WWY O
WW - Calendar week of production Y - Year of production O - Non radioactive
Switching spark gap B88069X0340xxxx a) SSG with lead wires FS08X-1GH KB AB E / KB AB PM Issue 08 / 2006-08-30 Please read Cautions and warnings and Page 3 of 5 Important notes at the end of this document. a) xxxx = T502 (taped and reeled with 500 pcs.) = T103 (taped and reeled with 1000 pcs.) 1) At delivery AQL 0,65 level II, DIN ISO 2859 2) Page 2, Fig. 1 and 2 3) Page 2, Fig. 3 and 4 Figures Fig. 4: Explanation of measurands Fig. 3: QC- test circuit (sampling inspection at 25 °C) DUT L C VO R VB VN 10 s 1 s tI Early ignition VB, FTE VB, FTE Range of VB, FIV VB t Fig. 1: QC- test circuit (100% outgoing inspection) Fig. 2: Explanation of measurands DUT ICU 0,22 F 51k I = const VS DUT device under test ICU ignition control unit (sensitivity 10 ... 30 A) Discharge current 10 – 20 mA VS, FTE VS VN -V N VS, FIV dVS/dt ~ dV N/dt
Switching spark gap B88069X0340xxxx a) SSG with lead wires FS08X-1GH KB AB E / KB AB PM Issue 08 / 2006-08-30 Please read Cautions and warnings and Page 4 of 5 Important notes at the end of this document. Dimensional Drawing Cautions and warnings Switching spark gaps may be used only within their specified values. Damaged switching spark gaps must not be re-used. Not to scale Dimensions in mm Non controlled document
The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application . These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons , it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of passive electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of a passive electronic component could endanger human life or health (e.g. in accident prevention or life-saving system s), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of a passive electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as “hazardous”) . Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time . The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products . Consequently, we cannot guarantee that all products named in this publication will always be available. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the “General Terms of Delivery for Products and Services in the Electrical Industry” published by the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, EPCOS-JONES, B aoke, CeraDiode, CSSP, MLSC, PhaseCap, PhaseMod, SIFI, SIKOREL, SilverCap, SIMID, SIOV, SIP5D, SIP5K, UltraCap, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks.