Switching Spark Gap FS08X-1GH Ordering code: B88069X0340xxxx a) KB AB E / KB AB PM Issue 07, 16.06.2004 Page 1 of 2 Nominal breakdown voltage VN 800 V Initial values 2) Static breakdown voltage V S 1) First ignition value V S, FTE after 24 hours in darkness Following ignition values V S, FIV ≤ 950 704 ... 896 V V Electrical life time 3) Breakdown voltage V B up to 100 000 Ignitions First ignition value V B, FTE after 24 hours in darkness Ignition time t I at V0 during life Following ignition values V B, FIV at 50 000 Ignitions Following ignition values V B, FIV ≤ 1000 ≤ 60 704 ... 920 680 ... 920 V ms V V Switching operations in total at – 40; +150 °C, each at + 25; +125 °C, each 100 000 10 000 40 000 Ignitions Ignitions Ignitions Test circuit parameters Open circuit voltage V Loading resistance R Discharge capacitance C Inductance L Discharge peak current I P 1000 114 0.13 ~ 660 V kΩ nF µH A General technical data Insulation resistance at 100 V Early ignition values between 530 ... 680 V Breakdown time Maximum loading current Weight > 100 ≤ 1 ≤ 50 ~ 2 MΩ ns mA g Marking, blue

800 WWY O

WW - Calendar week of production Y - Year of production O - Non radioactive a) xxxx = T502 (taped and reeled with 500 pcs.) = T103 (taped and reeled with 1000 pcs.) 1) At delivery AQL 0,65 level II, DIN ISO 2859 2) Page 2, Fig. 1 and 2 3) Page 2, Fig. 3 and 4

Switching Spark Gap FS08X-1GH Ordering code: B88069X0340xxxx a)  EPCOS AG 2002. Reproduction, publication and dissemination of this data sheet, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry recommended by the ZVEI (German Electrical and Electronic Manufacturers' Association), unless otherwise agreed. KB AB E / KB AB PM Issue 07, 16.06.2004 Page 2 of 2 Not to scale Dimensions in mm Non controlled document Fig. 4: Explanation of measurands Fig. 3: QC- test circuit (sampling inspection at 25 °C) DUT L C VO R VB VN 10 s 1 s tI Early ignition VB, FTE VB, FTE Range of VB, FIV VB t Fig. 1: QC- test circuit (100% outgoing inspection) Fig. 2: Explanation of measurands DUT ICU 0,22µF 51kΩ I = const VS DUT device under test ICU ignition control unit (sensitivity 10 .. 30 µA) Discharge current 10 – 20 mA VS, FTE VS VN -V N VS, FIV dVS/dt ~ dV N/dt t