Series/Type: B85321 Date: January 2006  EPCOS AG 2006. Repr oduction, publicat ion and dissem ination of t his dat a sheet and t he information contained therein without EPCOS’ prior express consent is prohibited.

Overview of available types Type Dia­ meter mm New Rated current (A) Rated voltage (VAC) Rated capacitance (µF) Terminal type Insertion loss in the frequeny range (Hz) Page 105 106 107 Feedthrough filters 5 B85321A*+160 16 ● 16 250 2 × 0.0025 6 B85321A*+160 20 ● 25 250, 500 2 × 0.0025 8 B85321A*A250 B85321A*A750 30 ● 25, 250 2 × 0.1 … 2 × 1.0 B85321A*A630, A101 … A501 55 ● 63 … 500 250 2 × 0.5 … 2 × 4.7 Legend Terminal type: Tab connectors Axial leads Soldering tags Threaded studs Please read Cautions and warnings and Important notes at the end of this document. 01/06

Feedthrough components from EPCOS are used f or EMI suppression of all electrical installations and equipment. This new type series is also outstandingly well suited for telephone exchanges and base stations. Thanks to broadband EMI suppression up to the GHz range, it prevents external in­ terference pulses being transmitted to the inside of the equipment via the supply network and vice­ versa. The essential features of this new type series are its modular design and the solder-free contacting technology developed by EPCOS with the aid of mesh contact. Mesh contact technology permits uniform concentric contacting of the MKP capacitor winding and avoids the thermal stress associated with soldering. The result is an e ven higher insertion loss, a high insulation resistance and a particularly compact case. The modular system used in this new technology for feedthrough capacitors and filters allows the cost-effective implementation of a wide range of standard types. Other capacitance values can also be supplied for special applications upon request. Feedthrough components fitted into a shielding wall. In feedthrough capacitors, the conductor carrying the operating current is connected concentrically to one electrode and is run centrally through the capacitor. The other electrode is contacted con­ centrically to the capacitor case. Feedthrough capacitors are dimensioned so that they perform well from low frequencies to far above 300 MHz. T he capacit or elem ent wit h low induct ance con tacted sec urely on t he f ace side is incorporated in a metal case provided with a screw thread. The f eedthrough f ilters are constructed i n a π-circuit. They c onsist of two ident ical capacitative transverse elements and an inductive longitudinal element. The concentric layout of the compon­ ents allows high insertion loss values to be attained in a frequency range to above 1 GHz. Safety note Feedthrough components with high capacitances require the implementation of safety measures in line with the applicable specifications! (See also Chapter “Mounting instructions”.) Please read Cautions and warnings and Important notes at the end of this document. 01/06

To fully utilize their RF properties, the feedthrough components must be mounted directly into shiel­ ding walls. The case must be contacted seamlessly (sealed agains t RF signals) t o the shielding wall. This can be best done by screwing it into a threaded hole or bushing so that contact is made via the threads. Alternatively, the feedthrough components may be screwed into feed-through holes on the shielding wall by means of attachment nuts. The contact between case and the shielding wall is then set up via the contact surface of the thread. Caution Contacts with rigid copper busbars are not permitted in view of mechanical stresses of the bushings due to impacts and vibrations. For types with screw connections, the connecting cable must be secured between two nuts to exclude a torque on the feedthrough pins. The use of two flat wrenches is recommended. Recommended tightening torques for feedthrough components (capacitors, filters) Thread dimensions Tightening torque (Nm) Tolerance (Nm) Terminal Thread base attachment M2 0.2 +0.05 × M3 0.6 +0.1 × M4 1.2 +0.1 × M5 2 +0.5 × M6 3 +0.5 × M8 5 +0.5 × M10 8 +2 × M12 12 +2 × M16 28 +2 × M18 35 +2 × M20 × 1 0 +1 × M27 × 1.5 16 +2 × Please read Cautions and warnings and Important notes at the end of this document. 01/06

Rated capacitance 2 × 0.0025 to 2 × 4.7 µF Construction ■ Building-block system ■ MKP technology (dry, self-healing) Dielectric: polypropylene, metallized ■ Metal case, polyurethane potting (UL 94 V-0) ■ For central screw fixing

Features

■ Compact dimensions ■ Versions with rated voltage 440 V AC available on request ■ High insertion loss ■ Easy to install ■ High contact reliability thanks to central screw fixing ■ Comply with EN 133200 ■ UL approval

Applications

Broadband interference suppression for AC/DC supply lines, e.g. in ■ shielded rooms ■ telephone exchanges, base stations ■ electrical machines and systems ■ power supplies Terminals ■ Threaded studs ■ Axial leads ■ Soldering tag ■ Tab connector Marking Manufacturer, ordering code, rated capacitance, rated voltage, rated current, climatic category, circuit diagram, date of manufacture (MM.YY), approvals Circuit diagram SSB1274-B Please read Cautions and warnings and Important notes at the end of this document. 01/06

1-line filters B85321A*+160 Feedthrough filters ∅ 16 mm, 16 A Feedthrough filters ∅ 16 mm Technical data and measuring conditions Rated voltage VR 250 V AC, 50/60 Hz

600 V DC

Rated current IR Referred to 40 °C ambient temperature Reduced current values at 400 Hz Capacitance tolerance ± 20% Climatic category (IEC 60068-1) 40/085/56 (–40 °C/+85 °C/56 days damp heat test) Screw cap fixing M10 × 0.75 Approvals UL 1283, 250 V Characteristics and ordering codes I R A CR µF VR V AC VR V DC Vtest V DC Terminal Fig. Ordering code Approvals 16 2 × 0.0025 250 600 2700 M2 1 B85321A2502X160 × 2 × 0.0025 250 600 2700 Soldering tag 2 B85321A2502Y160 × 2 × 0.0025 250 600 2700 Leads ∅ 2 mm 3 B85321A2502Z160 × 2 × 0.0025 250 600 2700 Tab connector 6.3 mm

4 B85321A2502W160 ×

× = approval granted Insertion loss (dB); typical values at 50 Ω CR (µF) 10 kHz 100 kHz 1 MHz 10 MHz 100 MHz 1 GHz Dimensional drawings Figure 1, B85321A2502X160 1...3 SSB2018-T 45+2 80+2 60+2 10 4_ ø10.5+0.3 Marking Thread Tightening torque M2 0.2 +0.05 Nm M10 × 0.75 3 +0.5 Nm ø16 M10 x 0.75 Please read Cautions and warnings and Important notes at the end of this document. 01/06

1-line filters B85321A*+160 Feedthrough filters ∅ 20 mm, 25 A Feedthrough filters ∅ 20 mm Technical data and measuring conditions Rated voltage VR 250 and 500 V AC, 50/60 Hz 600 and 700 V DC Rated current IR Referred to 40 °C ambient temperature Reduced current values at 400 Hz Capacitance tolerance ± 20% Climatic category (IEC 60068-1) 40/085/56 (–40 °C/+85 °C/56 days damp heat test) Screw cap fixing M12 × 0.75 Approvals UL 1283, 250 V Characteristics and ordering codes I R A CR µF VR V AC VR V DC Vtest V DC Terminal Figure Ordering code Approvals 25 2 × 0.0025 250 600 2700 M4 1 B85321A2502A160 × 2 × 0.0025 250 600 2700 Leads ∅ 2 mm

2 B85321A2502B160 ×

2 × 0.0025 500 700 3000 B85321A4502C160 × × = approval granted Insertion loss (dB); typical values at 50 Ω CR (µF) 10 kHz 100 kHz 1 MHz 10 MHz 100 MHz 1 GHz Please read Cautions and warnings and Important notes at the end of this document. 01/06

1-line filters B85321A*A250, A750 Feedthrough filters ∅ 30 mm, 25 A, 75 A Feedthrough filters ∅ 30 mm Technical data and measuring conditions Rated voltage VR 250 V AC, 50/60 Hz 500 and 600 V DC Rated current IR Referred to 40 °C ambient temperature Reduced current values at 400 Hz Capacitance tolerance ± 20% Climatic category (IEC 60068-1) 40/085/56 (–40 °C/+85 °C/56 days damp heat test) Screw cap fixing M20 × 1 Approvals UL 1283, 250 V Characteristics and ordering codes I R A CR µF VR V AC VR V DC Vtest V DC Terminal Ordering code Approvals 25 × 0.1 250 600 3000 M6 B85321A2204A250 × 2 × 0.5 250 600 2000 M6 B85321A2105A250 × 2 × 1.0 250 500 1700 M6 B85321A2205A250 × 75 × 0.1 250 600 3000 M6 B85321A2204A750 × 2 × 0.5 250 600 2000 M6 B85321A2105A750 – 2 × 1.0 250 500 1700 M6 B85321A2205A750 × × = approval granted Insertion loss (dB); typical values at 50 Ω CR (µF) 10 kHz 100 kHz 1 MHz 10 MHz 100 MHz 1 GHz 2 × 0.1 2 10 25 70 > 100 > 100 2 × 0.5 5 25 45 80 > 100 > 100 2 × 1.0 10 30 60 90 > 100 > 100 Dimensional drawing M20 x 1 SSB2085-J ø30 Marking 81+1 130 1_ Thread Tightening torque M6 3 +0.5 Nm M20 × 1 10 +1 Nm Please read Cautions and warnings and Important notes at the end of this document. 01/06

1-line filters B85321A*A630, A101 … A501 Feedthrough filters ∅ 55 mm, 63 … 500 A Feedthrough filters ∅ 55 mm Technical data and measuring conditions Rated voltage VR 250 V AC, 50/60 Hz 350 and 600 V DC Rated current IR Referred to 40 °C ambient temperature Reduced current values at 400 Hz Capacitance tolerance ±20% Climatic category (IEC 60068-1) 40/085/56 (–40 °C/+85 °C/56 days damp heat test) Screw cap fixing Standard M32 × 1.5 Special fixing M27 × 1.5 for filters up to 300 A on request Approvals UL 1283, 250 V Characteristics and ordering codes I R A CR µF VR V AC VR V DC Vtest V DC Terminal Dimensions (mm) Ordering code Approvals l +1 l1 –1 l2 –3 63 2 × 0.5 250 600 3000 M6 100 166 45 B85321A2105A630 × 2 × 1.0 250 600 2500 M6 100 166 45 B85321A2205A630 × 2 × 2.0 250 600 2500 M6 100 166 45 B85321A2405A630 × 2 × 4.7 250 350 1700 M6 100 166 45 B85321A2945A630 × 100 2 × 0.5 250 600 3000 M8 100 180 52 B85321A2105A101 × 2 × 1.0 250 600 2500 M8 100 180 52 B85321A2205A101 × 2 × 2.0 250 600 2500 M8 100 180 52 B85321A2405A101 × 2 × 4.7 250 350 1700 M8 100 180 52 B85321A2945A101 × 200 2 × 0.5 250 600 3000 M10 100 185 55 B85321A2105A201 × 2 × 1.0 250 600 2500 M10 100 185 55 B85321A2205A201 × 2 × 2.0 250 600 2500 M10 100 185 55 B85321A2405A201 × 2 × 4.7 250 350 1700 M10 100 185 55 B85321A2945A201 × 300 2 × 0.5 250 600 3000 M12 100 195 60 B85321A2105A301 × 2 × 1.0 250 600 2500 M12 100 195 60 B85321A2205A301 × 2 × 2.0 250 600 2500 M12 100 195 60 B85321A2405A301 – 2 × 4.7 250 350 1700 M12 100 195 60 B85321A2945A301 × 400 2 × 0.5 250 600 3000 M16 130 245 72 B85321A2105A401 – 2 × 1.0 250 600 2500 M16 130 245 72 B85321A2205A401 – 2 × 2.0 250 600 2500 M16 130 245 72 B85321A2405A401 – 2 × 4.7 250 350 1650 M16 130 245 72 B85321A2945A401 – × = approval granted Please read Cautions and warnings and Important notes at the end of this document. 01/06

1-line filters B85321A*A Feedthrough filters ∅ 55 mm, 63 … 500 A Characteristics and ordering codes I R A CR µF VR V AC VR V DC Vtest V DC Terminal Dimensions (mm) Ordering code Approvals l +1 l1 –1 l2 –3 500 2 × 0.5 250 600 3000 M18 130 250 75 B85321A2105A501 – 2 × 1.0 250 600 2500 M18 130 250 75 B85321A2205A501 – 2 × 2.0 250 600 2500 M18 130 250 75 B85321A2405A501 – 2 × 4.7 250 350 1650 M18 130 250 75 B85321A2945A501 – × = approval granted Insertion loss (dB); typical values at 50 Ω CR (µF) 10 kHz 100 kHz 1 MHz 10 MHz 100 MHz 1 GHz 2 × 0.5 5 25 45 80 > 100 > 100 2 × 1.0 10 30 60 > 100 > 100 > 100 2 × 2.0 15 35 70 > 100 > 100 > 100 2 × 4.7 25 40 90 > 100 > 100 > 100 Dimensional drawing A/F 41 55±1 A/F 10 15+1 M Marking M32 x 1.5 SSB1273-3-E Thread Tightening torque M6 3 +0.5 Nm M8 5 +0.5 Nm M10 8 +2 Nm M12 12 +2 Nm M16 28 +2 Nm M18 35 +2 Nm Thread Tightening torque M27 × 1.5 16 +2 Nm M32 × 1.5 24 +2.5 Nm Please read Cautions and warnings and Important notes at the end of this document. 01/06

Please read all safety and warning notes carefully before installing the EMC filter and putting it into operation (see ). The same applies to the warning signs on the filter. Please ensure that the signs are not removed nor their legibility impaired by external influences. Death, serious bodily injury and substantial material damage to equipment may occur if the appro­ priate safety measures are not carried out or the warnings in the text are not observed. Using according to the terms The EMC filters may be used only for their intended application within the specified values in low­ voltage networks in compliance with the instructions given in the data sheets and the data book. The conditions at the place of application must comply with all specifications for the filter used. Warnings ■ It shall be ensured that only qualified persons (electricity specialists) are engaged on work such as planning, assembly, installation, operation, repair and maintenance. They must be provided with the corresponding documentation. ■ Danger of electric shock. EMC filters contain components that store an electric charge. Danger­ ous voltages can continue to exist at the filter terminals for longer than five minutes even after the power has been switched off. ■ The protective earth connections shall be the first to be made when the EMC filter is installed and the last to be disconnected. Depending on the magnitude of the leakage currents, the particular specifications for making the protective-earth connection must be observed. ■ Impermissible overloading of the EMC filter, such as impermissible voltages at higher frequen­ cies that may cause resonances etc. can lead to destruction of the filter housing. ■ EMC filters must be prot ected in the application against impermissible excee ding of the rated currents by suitable overcurrent protective. 13 01/06

The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas o f a pplication. T hese statements are bas ed on o ur know ledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expres sly point out that su ch st atements can not b e reg arded as b inding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons , it is always ultimately incum bent on t he customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of passive electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of a passive electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of t he c ustomer a pplication or ot her ac tion t aken by t he cu stomer (e. g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of a passive electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirem ents, some of t he products describ ed in t his publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as “hazardous”). Useful information on this will be found in our Material Data Sheets on the Internet (www. epcos.com/material). Should you hav e any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may ch ange from time to time. The same is t rue of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We a lso reserve the ri ght t o discontinue p roduction a nd d elivery of p roducts. Consequently, we cannot guarantee that all pr oducts named in this publication will always be available. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the “General Terms of Delivery for Products and Services in the Electrical Industry” published by the German Electrical and Electronics Industry Association (ZVEI). 7. The t rade nam es EPCOS, EPCOS-Jones, Baoke, C eraDiode, CSSP, ML SC, Phas eCap, PhaseMod, SIFI, SIKOREL, SilverCap, SIMID, SIOV, SIP5D, SIP5K, UltraCap, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks. 14 01/06