Filters for Communication Lines Analog Systems and Control Lines Series/Type: B84312 Date: January 2004 EPCOS AG 2004. Reproduction, publication and dissemination of this data sheet, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry recommended by the ZVEI (German Electrical and Electronic Manufacturers' Associ- ation), unless otherwise agreed.
Stopband attenuation up to 40 GHz
Features
Use of coaxial feed-through capacitors on input and output Single or current-balanced chokes depending on requirement Insertion loss to CISPR 17 Also available with integrated EMP protection Installation Single filters are attached directly to the shielding wall. Larger numbers can be housed in filter cabinets or boxes. Various models and the matching flexible connector fittings are available. Mechanical design The electrical components are incorporated in an RF-tight case of tin-plated sheet steel. Filters are available for 2 or 20 lines and for upright or flat installation on shielding wall. Model Installation Filter selection B84312C Upright Space-saving solution for installing a number of different filters. B84312C*B (2-line) B84312C*H (20-line) B84312F Flat Low profile and thus advantage especially for just one or a few filters. B84312F*B (2-line) Filters for communication lines B84312 Analog systems and control lines
The following standard filters are designed for the most common applications; customized models can be produced for differing requirements. Passband kHz ZL Ω IR A Application Circuit diagram No. of lines Series B84312 +0020B* C0020H* requirements (stopband attenuation of 100 dB above 10 kHz ) 3 2 +0090B* C0090H* DC ... 50 600 0.1 Filters for telephone systems and modem cables, conditionally for control lines with critical signal rise times 1 2 +0040B* C0040H* DC ...120 150 0.1 Data signals with balanced signal transmission mode as used 2 2 +0050B* C0050H* DC ... 300 150 0.1 by modems or interfaces RS 485 up to 9600 Baud and/or RS 422 up to 19200 Baud 2 2 +0060B* C0060H* DC ... 120 100 2 Smoke detectors with serial data transmission in bus systems and remote power feeding, temperature switches,
24 V emergency lighting, DC motors
+0050B* C0050H* 3 24-V emergency lighting, DC motors, signal and control lines 2 2 +0050B* C0050H*
1 Universal filters for signal and control
+0030B* C0030H*
1 Control lines with up to 1 A and
enhanced attenuation requirements 3 2 +0100B* C0100H* +: C = upright installation, F = flat installation Filters for communication lines B84312 Analog systems and control lines
The diagrams each show a circuit of a 2-line filter. In the series of 20-line filters there are 10 of them in each case. Circuit diagram 1 Circuit diagram 2 Circuit diagram 3 Note on circuit diagrams 2 and 3: These filters are mounted with current-compensated chokes. Make sure that the forward and re- turn line are routed paired through one filter. Filters for communication lines B84312 Analog systems and control lines
1) Typical test pulse: rise time 10 ns, time to half value 1500 ns, charge voltage min. 50 kV, source impedance 90 Ω General technical data Rated voltage VR,AC 100 V Rated voltage VR,DC 100 V Rated frequency fR Pass bandwidth at ZL Rated current IR See characteristics TA = 40 °C Line impedance ZL See characteristics Test voltage Vtest 250 VDC, 2 s Line/line
250 VDC, 2 s Line/case
Maximum DC resistance Rmax See characteristics Per line Permissible ambient temperature TA 25/+40 °C Climatic category (EN 60068-1) 25/085/56 25 °C/+85 °C/56 days damp heat test Weight 560 g 2-line filters 4.5 kg 20-line filters Mechanical version C Upright for 2- and 20-line filters F Flat for 2-line filters Filters with EMP protection: Nominal DC spark-over voltage VsdcN <500 V Per line Surge response voltage <800 V At 1 kV/µs <800 V At 1 kV/ns Nominal surge current (8/20 µs) 5/10 kA Suppression condition I ≤ IR Maximum voltage on filter output for filters with EMP protection Series B84312 ...0020+1 ...0090+1 ...0030+1 ...0100+1 Pulse shape in symmetrical circuit dv/dt = 0.1 kV/µs 2 V 360 V 8 V 3 V 12 V dv/dt = 1 kV/µs 1 V 60 V 3 V 2 V 9 V dv/dt = 1 kV/ns1) 0.5 V 2 V 0.5 V 0.5 V 1.2 V Nominal surge current (8/20 µs) 5 V 290 V 12 V 10 V 12 V Pulse shape in unsymmetrical circuit dv/dt = 0.1 kV/µs 50 V 700 V 250 V 120 V 280 V dv/dt = 1 kV/µs 35 V 130 V 60 V 25 V 30 V dv/dt = 1 kV/ns1) 1 V 5 V 3 V 1 V 1 V Nominal surge current (8/20 µs) 20 V 200 V 110 V 25 V 50 V Filters for communication lines B84312 Analog systems and control lines
2) Control line filters, not matched 3) Not specified Characteristics and ordering codes IR A Pass bandwidth kHz ZL Ω Rmax Per line Ω Circuit diagram Number of lines Ordering code *: 0 = Standard filters 1 = Filters with EMP protection 1 2) 3) 0.4 1 2 B84312C0030B*03 1 2) 3) 0.4 1 2 B84312F0030B*03 1 2) 3) 0.4 1 20 B84312C0030H*03 2 DC ... 120 100 0.4 2 2 B84312C0050B*21 2 DC ... 120 100 0.4 2 2 B84312F0050B*21 2 DC ... 120 100 0.4 2 20 B84312C0050H*21 3 2) 3) 0.2 2 2 B84312C0050B*31 3 2) 3) 0.2 2 2 B84312F0050B*31 3 2) 3) 0.2 2 20 B84312C0050H*31 1 2) 3) 0.6 3 2 B84312C0100B*03 1 2) 3) 0.6 3 2 B84312F0100B*03 1 2) 3) 0.6 3 20 B84312C0100H*03 Filters for communication lines B84312 Analog systems and control lines
Insertion lossα e in passband(typical) Symmetrical measurement circuit with ZL = 600 Ω Symmetrical measurement circuit with ZL = 150 Ω Filters for communication lines B84312 Analog systems and control lines
Unsymmetrical measurement (common-mode-rejection) in passband Filter with ZL = 600 Ω CMR >40 dB in passband Filters for communication lines B84312 Analog systems and control lines
Insertion lossα e in stopband(typical) Unsymmetrical measurement circuit Asymmetrical measurement to MIL-STD-220A Filters for communication lines B84312 Analog systems and control lines
2-line filters, upright installation ➀ Line connections at both ends: 2 x tab connectors for receptacle 2.8 x 0.5 (in accessory bag) ➁ Strain relief with ground connection for cable diameter 4.5 ... 6 mm Hole for installation in shielding wall Filters for communication lines B84312 Analog systems and control lines
2-line filters, flat installation ➀ Line connections at both ends: 2 x tab connectors for receptacle 2.8 x 0.5 (in accessory bag) ➁ Strain relief with ground connection for cable diameter 4.5 ... 6 mm Hole for installation in shielding wall Filters for communication lines B84312 Analog systems and control lines
20-line filters, upright installation Hole for installation in shielding wall Adapter A bracket adapter is available for flat installation on the shielding wall. Ordering code: B84298M0012C004 Filters for communication lines B84312 Analog systems and control lines