16 to 100 A, 100 dB from 150 kHz Series/Type: B84299*B001/B84299*E001 Date: January 2004 EPCOS AG 2004. Reproduction, publication and dissemination of this data sheet, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry recommended by the ZVEI (German Electrical and Electronic Manufacturers' Associ- ation), unless otherwise agreed.
Standard filters for measuring cabins Single-stage Stopband attenuation 150 kHz to 40 GHz
Features
General-purpose use through design with separate lines without intercoupling Use of single chokes. Thus the insertion loss values are not reduced under all operating cur- rent conditions and not when operated with artificial mains networks (AMN) or other equipment with high leakage currents. Insertion loss to CISPR 17 Design The electrical components are incorporated in an RF-tight case of stainless steel. The cables enter through glands. The RF-tight termination of the openings is produced by specially shaped lids. The conductors and equipment grounding conductor are connected by threaded bolts. The sur- face around the fixing holes is left as bare metal (unpainted) to ensure good RF contact with met- al surfaces (chassis, ground). Protective measures (grounding) The high capacitances between the lines and ground require special protective measures. If there are no product-specific requirements, protection with a secondary ground wire (cross section min. 10 mm2) in accordance with EN 50178 is necessary. For this purpose the filter case have con- necting bolts at each end. Resistors are incorporated in the filter to discharge capacitors after turn-off. Scope of supply Filters are supplied complete with all parts required for RF-tight installation (fixing screws, flanges, RF gaskets, cable glands) and installation instructions. Installation No welding is needed on the shielding wall, so any subsequent installation is quite simple. Accessories and special versions RF-tight flexible connector fittings are available for installation spaced away from the shielding wall. Filters with an EMP protection add-on for surge currents up to 100 kA per line are available on request. To match requirements, filters can be supplied with different kinds of EMC or shield- ing cable glands. Tests All filters are 100% tested and the results are archived under a filter's serial number. If required, a test report can be generated for the serial number. Filters for power lines B84299*B001 16 to 100 A, 100 dB from 150 kHz B84299*E001
Filters for power lines B84299*B001 16 to 100 A, 100 dB from 150 kHz B84299*E001
Insertion lossα e (typical values at Z = 50 Ω ) Asymmetrical measurement circuit to MIL-STD-220A General technical data Rated voltage VR 250 V Line/line 2-line filters Line/case Rated voltage VR 440 V Line/line 4-line filters 250 V Line/case Rated frequency fR 50/60 Hz Rated current IR See characteristics Referred to +40 °C ambient temperature Maximum admissible overcurrent Iover 75 IR for 50 ms
10 IR for 1 s
2 IR for 1 min
1.4 IR for 15 min
Test voltage Vtest 1200 VDC, 2 s Line/line
1200 VDC, 2 s Line/case
Voltage drop/phase ΔV <1 % Of VR at 50 Hz and IR Maximum DC resistance Rmax See characteristics Per line Filters for power lines B84299*B001 16 to 100 A, 100 dB from 150 kHz B84299*E001
General technical data (continued) Power dissipation PD See characteristics At rated current IR Capacitive reactive current/line Ireactive See characteristics At 400/230 V and 50 Hz (typical value) Max. permissible harmonic distortion (THD) 8 % To EN 50160 Permissible ambient temperature TA 25/+40 °C Climatic category (EN 60068-1) 25/085/56 25 °C/+85 °C/56 days damp heat test Mechanical version C Cable glands at both ends or flexible connector fitting D Direct connection to shielding wall Characteristics and ordering codes IR A Mechanical version Rmax mΩ PD W Ireactive A Dimensional drawing Page Approx. weight kg Ordering code 2-line filters 16 C < 25 < 15 0.7 1 6 8 B84299C2160B001 16 D < 25 < 15 0.7 2 7 8 B84299D2160B001 32 C < 20 < 40 1.0 3 8 15 B84299C2320B001 32 D < 20 < 40 1.0 4 9 15 B84299D2320B001 63 C < 3.0 < 25 1.0 5 10 18 B84299C1630B001 63 D < 3.0 < 25 1.0 6 11 18 B84299D1630B001 100 C < 1.5 < 30 1.0 7 12 18 B84299C1101B001 100 D < 1.5 < 30 1.0 8 13 18 B84299D1101B001 4-line filters 16 C < 50 < 30 0.7 9 14 16 B84299C2160E001 16 D < 50 < 30 0.7 10 15 16 B84299D2160E001 32 C < 20 < 40 1.0 11 16 20 B84299C2320E001 32 D < 20 < 40 1.0 12 17 20 B84299D2320E001 63 C < 3.0 < 35 1.0 5 10 20 B84299C1630E001 63 D < 3.0 < 35 1.0 6 11 20 B84299D1630E001 100 C < 1.5 < 45 1.0 7 12 20 B84299C1101E001 100 D < 1.5 < 45 1.0 8 13 20 B84299D1101E001 Filters for power lines B84299*B001 16 to 100 A, 100 dB from 150 kHz B84299*E001
Dimensional drawing 1(cable glands at both ends) 2 x 16 A B84299C2160B001 ➀ Input end: Cable gland PG 21 (mounted) ➁ Shielded end: Cable gland PG 29/21 (cable gland PG 29, PG 21 and reducer ring in accessory bag) Paint color: RAL 7035 (light gray, semigloss) Fixing dimensions The cable glands (with cutout sealing ring) are suitable for the following overall cable diameter: PG 29 17 to 19 mm 20 to 22 mm 23 to 25 mm 26 to 28 mm PG 21 9 to 11 mm 12 to 14 mm 15 to 17 mm 18 to 20 mm RF-tight connection to shielding wall with connector fitting, see page 18. Filters for power lines B84299*B001 16 to 100 A, 100 dB from 150 kHz B84299*E001
Dimensional drawing 2(direct connection to shielding wall) 2 x 16 A B84299D2160B001 ➀ Input end: Cable gland PG 21 (mounted) ➁ Shielded end: Cable gland PG 29/21 (cable gland PG 29, PG 21 and reducer ring in accessory bag) Paint color: RAL 7035 (light gray, semigloss) Fixing dimensions The cable glands (with cutout sealing ring) are suitable for the following overall cable diameter: PG 29 17 to 19 mm 20 to 22 mm 23 to 25 mm 26 to 28 mm PG 21 9 to 11 mm 12 to 14 mm 15 to 17 mm 18 to 20 mm RF-tight connection to shielding wall, see page 18. Filters for power lines B84299*B001 16 to 100 A, 100 dB from 150 kHz B84299*E001
Dimensional drawing 3(cable glands at both ends) 2 x 32 A B84299C2320B001 ➀ Input end: Cable gland PG 21 (mounted) ➁ Shielded end: Cable gland PG 29/21 (cable gland PG 29, PG 21 and reducer ring in accessory bag) Paint color: RAL 7035 (light gray, semigloss) Fixing dimensions The cable glands (with cutout sealing ring) are suitable for the following overall cable diameter: PG 29 17 to 19 mm 20 to 22 mm 23 to 25 mm 26 to 28 mm PG 21 9 to 11 mm 12 to 14 mm 15 to 17 mm 18 to 20 mm RF-tight connection to shielding wall with connector fitting, see page 18. Filters for power lines B84299*B001 16 to 100 A, 100 dB from 150 kHz B84299*E001
Dimensional drawing 4(direct connection to shielding wall) 2 x 32 A B84299D2320B001 ➀ Input end: Cable gland PG 21 (mounted) ➁ Shielded end: Cable gland PG 29/21 (cable gland PG 29, PG 21 and reducer ring in accessory bag) Paint color: RAL 7035 (light gray, semigloss) Fixing dimensions The cable glands (with cutout sealing ring) are suitable for the following overall cable diameter: PG 29 17 to 19 mm 20 to 22 mm 23 to 25 mm 26 to 28 mm PG 21 9 to 11 mm 12 to 14 mm 15 to 17 mm 18 to 20 mm RF-tight connection to shielding wall, see page 18. Filters for power lines B84299*B001 16 to 100 A, 100 dB from 150 kHz B84299*E001
Dimensional drawing 5(cable glands at both ends) 2 x 63 A / 4 x 63 A B84299C1630B001, ...E001 ➀ Input end: Cable gland PG 29/21 (PG 29 mounted, PG 21 and reducer ring in accessory bag) ➁ Shielded end: Cable gland PG 29/21 (cable gland PG 29, PG 21 and reducer ring in accessory bag) Paint color: RAL 7035 (light gray, semigloss) Fixing dimensions The cable glands (with cutout sealing ring) are suitable for the following overall cable diameter: PG 29 17 to 19 mm 20 to 22 mm 23 to 25 mm 26 to 28 mm PG 21 9 to 11 mm 12 to 14 mm 15 to 17 mm 18 to 20 mm RF-tight connection to shielding wall with connector fitting, see page 18. Filters for power lines B84299*B001 16 to 100 A, 100 dB from 150 kHz B84299*E001
Dimensional drawing 6(direct connection to shielding wall) 2 x 63 A / 4 x 63 A B84299D1630B001, ...E001 ➀ Input end: Cable gland PG 29/21 (PG 29 mounted, PG 21 and reducer ring in accessory bag) ➁ Shielded end: Cable gland PG 29/21 (cable gland PG 29, PG 21 and reducer ring in accessory bag) Paint color: RAL 7035 (light gray, semigloss) Fixing dimensions The cable glands (with cutout sealing ring) are suitable for the following overall cable diameter: PG 29 17 to 19 mm 20 to 22 mm 23 to 25 mm 26 to 28 mm PG 21 9 to 11 mm 12 to 14 mm 15 to 17 mm 18 to 20 mm RF-tight connection to shielding wall, see page 18. Filters for power lines B84299*B001 16 to 100 A, 100 dB from 150 kHz B84299*E001
Dimensional drawing 7(cable glands at both ends) 2 x 100 A / 4 x 100 A B84299C1101B001, ...E001 ➀ Input end: Cable gland PG 42/29 (PG 42 mounted, PG 29 and reducer ring in accessory bag) ➁ Shielded end: Cable gland PG 42/29 (cable gland PG 42, PG 29 and reducer ring in accessory bag) Paint color: RAL 7035 (light gray, semigloss) Fixing dimensions The cable glands (with cutout sealing ring) are suitable for the following overall cable diameter: PG 42 29 to 31 mm 32 to 34 mm 35 to 37 mm 38 to 40 mm PG 29 17 to 19 mm 20 to 22 mm 23 to 25 mm 26 to 28 mm RF-tight connection to shielding wall with connector fitting, see page 18. Filters for power lines B84299*B001 16 to 100 A, 100 dB from 150 kHz B84299*E001
Dimensional drawing 8(direct connection to shielding wall) 2 x 100 A / 4 x 100 A B84299D1101B001, ...E001 ➀ Input end: Cable gland PG 42/29 (PG 42 mounted, PG 29 and reducer ring in accessory bag) ➁ Shielded end: Cable gland PG 42/29 (cable gland PG 42, PG 29 and reducer ring in accessory bag) Paint color: RAL 7035 (light gray, semigloss) Fixing dimensions The cable glands (with cutout sealing ring) are suitable for the following overall cable diameter: PG 42 29 to 31 mm 32 to 34 mm 35 to 37 mm 38 to 40 mm PG 29 17 to 19 mm 20 to 22 mm 23 to 25 mm 26 to 28 mm RF-tight connection to shielding wall, see page 18. Filters for power lines B84299*B001 16 to 100 A, 100 dB from 150 kHz B84299*E001
Dimensional drawing 9(cable glands at both ends) 4 x 16 A B84299C2160E001 ➀ Input end: Cable gland PG 21 (mounted) ➁ Shielded end: Cable gland PG 29/21 (cable gland PG 29, PG 21 and reducer ring in accessory bag) Paint color: RAL 7035 (light gray, semigloss) Fixing dimensions The cable glands (with cutout sealing ring) are suitable for the following overall cable diameter: PG 29 17 to 19 mm 20 to 22 mm 23 to 25 mm 26 to 28 mm PG 21 9 to 11 mm 12 to 14 mm 15 to 17 mm 18 to 20 mm RF-tight connection to shielding wall with connector fitting, see page 18. Filters for power lines B84299*B001 16 to 100 A, 100 dB from 150 kHz B84299*E001
Dimensional drawing 10(direct connection to shielding wall) 4 x 16 A B84299D2160E001 ➀ Input end: Cable gland PG 21 (mounted) ➁ Shielded end: Cable gland PG 29/21 (cable gland PG 29, PG 21 and reducer ring in accessory bag) Paint color: RAL 7035 (light gray, semigloss) Fixing dimensions The cable glands (with cutout sealing ring) are suitable for the following overall cable diameter: PG 29 17 to 19 mm 20 to 22 mm 23 to 25 mm 26 to 28 mm PG 21 9 to 11 mm 12 to 14 mm 15 to 17 mm 18 to 20 mm RF-tight connection to shielding wall, see page 18. Filters for power lines B84299*B001 16 to 100 A, 100 dB from 150 kHz B84299*E001
Dimensional drawing 11(cable glands at both ends) 4 x 32 A B84299C2320E001 ➀ Input end: Cable gland PG 21 (mounted) ➁ Shielded end: Cable gland PG 29/21 (cable gland PG 29, PG 21 and reducer ring in accessory bag) Paint color: RAL 7035 (light gray, semigloss) Fixing dimensions The cable glands (with cutout sealing ring) are suitable for the following overall cable diameter: PG 29 17 to 19 mm 20 to 22 mm 23 to 25 mm 26 to 28 mm PG 21 9 to 11 mm 12 to 14 mm 15 to 17 mm 18 to 20 mm RF-tight connection to shielding wall with connector fitting, see page 18. Filters for power lines B84299*B001 16 to 100 A, 100 dB from 150 kHz B84299*E001
Dimensional drawing 12(direct connection to shielding wall) 4 x 32 A B84299D2320E001 ➀ Input end: Cable gland PG 21 (mounted) ➁ Shielded end: Cable gland PG 29/21 (cable gland PG 29, PG 21 and reducer ring in accessory bag) Paint color: RAL 7035 (light gray, semigloss) Fixing dimensions The cable glands (with cutout sealing ring) are suitable for the following overall cable diameter: PG 29 17 to 19 mm 20 to 22 mm 23 to 25 mm 26 to 28 mm PG 21 9 to 11 mm 12 to 14 mm 15 to 17 mm 18 to 20 mm RF-tight connection to shielding wall, see page 18. Filters for power lines B84299*B001 16 to 100 A, 100 dB from 150 kHz B84299*E001
RF-tight connection to shielding wall with connector fitting (mechanical version C) Cable gland Connector fitting (must be ordered separately) Ordering code Hole in shielding wall Bare metal area on shielding wall PG 29 Nominal width 25 mm B84298A0042L* ∅ 37 +0.5 mm ∅ 55 +5 mm PG 42 Nominal width 40 mm B84298A0044L* ∅ 54 +0.5 mm ∅ 70 +5 mm (***: add required length in cm (see also chapter "Installation accessories"). RF-tight connection to shielding wall (mechanical version D) Cable gland Parts for RF-tight mounting (in accessory bag) Required hole in shielding wall Bare metal area on shielding wall PG 21 Suitable cable gland with ∅ 37 +0.5 mm ∅ 55 +5 mm PG 29 long thread, RF gasket PG 42 and check nut. ∅ 54 +0.5 mm ∅ 70 +5 mm Filters for power lines B84299*B001 16 to 100 A, 100 dB from 150 kHz B84299*E001