- Super miniature long-distance diffuse reflective sensor that can be installed anywhere
- Designed to be immune to ambient light
- Screws can be mounted from 4 directions Model Type (Consult your trading company for the prices.) ■ Device [Dimensions P.4] *1. In case of light-ON, control output is turned ON when a sensing object is detected. Accessories (order separately) ■ Connector with cable As it is not supplied with the sensor, order as needed. Refer to “Safety Precautions” on page 5. Sensing method Appearance Size Connecting method Output type Sensing distance Operation mode Model Minimum number of deliverable units (Unit: piece) Diffuse reflective Super miniature Connector NPN open collector 550 mm Light-ON *1 B5W-DB1452-1 1 B5W-DB1452-2 1500 Appearance Cord length Model Applicable model 1 m EE-5002 1 M B5W-DB1452-1 B5W-DB1452-2 B5W-DB - (5)(1) (2) (3) (4) (1) Size (2) Sensing distance (3) Output (4) Degree of protection (5) Minimum number of deliverable units 1: Super miniature 4: 550 mm 5: NPN/Light-ON 2: Supported 1: 1 piece 2: 1,500 pieces
Ratings and Specifications ■ Digital output models *1. In case of light-ON, control output is turned ON when a sensing object is detected. I/O Circuit Diagrams ■ NPN output *1. “Incident light” means there is a sensing object. “No incident light” means there is no sensing object. Sensing method Diffuse reflective Item Model B5W-DB1452-1, B5W-DB1452-2 Sensing distance (white paper) 550 mm Hysteresis 30% max. Light source (wavelength) Infrared LED (850 nm) Power supply voltage 12 VDC±10% including 10% ripple (p-p) Current consumption 20 mA max. (at 13.2 VDC) Operating mode Light-ON *1 Control output Load power supply voltage: 13.2 VDC, Load current: 50 mA max., Residual voltage: 0.8 V max. at 50 mA load current and 0.32 V max. at 10 mA load current, Open collector output (NPN) Response time Operate/reset: 1 ms max. Ambient illumination Illumination on the surface of the receiver Incandescent lamp: 3,000 lx max., Sunlight: 10,000 lx max. Ambient temperature range Operating: -10 to +60°C, Storage: -25 to +80°C (with no icing or condensation) Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 h each in X, Y, and Z directions Shock resistance 500 m/s2 3 times each in X, Y and Z directions Degree of protection IEC IP50 (not including terminals) Connecting method Connector models Weight (unit only) Approx. 1.6 g Materials Case Polycarbonate (PC) Lens Acrylic (PMMA) Cover Polycarbonate (PC) Model Operating mode Timing charts Output circuit B5W-DB1452-1 B5W-DB1452-2 Light-ON Incident light No incident light ON OFF Operate Reset Output transistor Load DC12V Main circuit Load Sensor Terminal No. Name (1) GND (2) Vout (3) Vcc
Engineering Data (Reference Value) ■ Operating Range (Left and Right) Operating Range (Up and Down) ■ Receiver Output-Sensing Distance Characteristics ■ Size of Sensing Object-Distance Characteristics ■ Angle Characteristics (Left and Right) Angle Characteristics (Up and Down) -30.0 -20.0 -10.0 0.0 10.0 20.0 30.0 0 200 400 600 800 1000 Sensing object: white paper Distance X Distance Y Sensing object Sensor Distance X (mm) Distance Y (mm) -30.0 -20.0 -10.0 0.0 10.0 20.0 30.0 0 200 400 600 800 1000 Sensing object: white paper Distance X Sensing object Distance Y Distance X (mm) Sensor Distance Y (mm) Distance (mm)Sensing object: white paper Operating level 0.1 100 0 200 400 600 800 1000 Excess gain (multiple) 200 400 600 800 1000 0 50 100 150 200 250 300 350 Side length (one side) of sensing object: d (mm) d d Sensing object: white paper Sensing distance (mm) Angle (deg.) 200 400 600 800 1000 1200 1400 -20 -15 -10 -5 0 5 10 15 20 White paper Transparent Sensing object Sensor Distance (mm) Angle (deg.) 200 400 600 800 1000 1200 1400 -20 -15 -10 -5 0 5 10 15 20 Distance (mm)Sensor Sensing object +θ-θ White paper Transparent
Connector with cable (order separately) marked products, 2D drawings and 3D CAD models are available. For CAD information, please visit our website, which is noted on the last page. CAD Data (Unit: mm) Unspecified dimension tolerance: tolerance class IT16 3.9 (Center of receiver lens) 3.6 (Center of emitter lens) ø3.2 (2) BM03B-GHLE-TBT manufactured by JST (3) (1) R3.76 3.2 8.4 3.4 Mark (Brand mark, model name, Lot No. QR code) Terminal No. Name (1) GND (2) Vout (3) Vcc B5W-DB1452-1 B5W-DB1452-2 CAD Data (3)(1) (2) 1,000±10 3±0.5 EE-5002 1M No. Product Name Model/specifications Quantity Manufacturer (1) Connector, HS for 101-150 harness GHR-03V-S 1 JST (2) Connector, CT for 101-150 harness SSHL-002TP0.2 3 JST (3) Lead wire UL1061 AWG26 3- Wiring Table Connector circuit number Lead wire color 1B lue 2B lack 3B rown
To ensure safe operation, be sure to read and follow the Terms and Conditions Agreement. This product cannot be used in safety devices for presses or other safety devices used to protect human life. This product is designed for use in applications for sensing workpieces and workers that do not affect safety. This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes. To ensure safety, observe the following precautions.
- Wiring Power Supply Voltage Do not use the product with voltage or current in excess of the operating voltage or current. Applying any excessive voltage or current or supplying AC power to a DC-type sensor may cause the sensor to explode or burn. Load Short-Circuit Do not short-circuit the load. Otherwise the product may be damaged or it may burn. Faulty Wiring Do not miswire such as the polarity of the power supply voltage. Otherwise, the product may be damaged or it may burn. Example 1) Wrong polarity Connection without load If the power supply is connected directly without a load, the internal elements may explode or burn. Be sure to insert a load when connecting the power supply. AND Connection With an AND connection as shown in the figure below, a voltage is applied to Vcc while GND of sensor 2 is not securely grounded. A failure may occur. Do not make this kind of connection. Also in some models, an inrush current may occur in sensor 2 when sensor 1 is turned on, causing failure or malfunction. Storage and Operating Environment (1 ) Places where the product is not exposed to corrosive gases, such as hydrogen sulfide gas, or salty wind. (2 ) Places where it is not exposed to direct sunlight. (3 ) Make sure that flux, oil, or other chemicals do not adhere to the surface of the emitter and receiver. (4 ) Do not apply a load that may deform or deteriorate the product in any circumstances. (5 ) Store the product in a normal temperature, humidity, and pressure environment. ( 6 ) The product should be used without freezing or condensation. (7 ) Do not use the product in atmospheres or environments that exceed product ratings. (8 ) This product does not have a water-proof structure. Therefore, do not use it in an application or environment where it will be subjected to plashes from water, oil, or any other liquid. Warning Caution Precautions for Safe Use Load Vcc OUT GND Sensor Load Vcc OUT GND Sensor ++ (Load short-circuit) Load Load Vcc OUT GND Sensor (Load short-circuit) LoadVcc OUT GND Sensor Load Vcc OUT GND Sensor cuit) UT GND Vcc OUT GND Sensor ++ Vcc OUT GND Sensor 1 Vcc OUT GND Sensor 2 ++ Load
- Mounting (1 ) Ambient light may cause the sensor to malfunction. In such case, mount the sensor at an angle that ambient light does not enter the receiver lens. Make sure that the sensor is not affected by ambient light. (2 ) Mount the sensor securely on a flat surface. (3 ) Use M3 screws to secure the sensor (use together with spring washers and 6-mm-diameter flat washers to prevent screws from loosening). Use a tightening torque of 0.54 N·m max. (4 ) Take care that nothing comes into contact with the detected part of the sensor. Damage to the sensing element will result in poor performance. (5 ) Before using the sensor, check to make sure that it has not become loose due to vibration or shock.
- Wiring Surge Prevention (1 ) If there is a surge in the power supply line, try connecting a Zener diode or a capacitor (with a capacitance of 0.1 to 1 µF), depending on the operating environment. Use the sensor only after confirming that the surge has been removed. We recommended use of 20 to 25 V Zener diodes for a 12 VDC power supply. (2 ) Do not use a small inductive load, such as a relay. (3 ) Separate the wiring for the sensor from high-voltage lines or power lines. If the wiring is routed in the same conduit or duct as such lines, the sensor may malfunction or may be damaged by inductive interference. (4 ) Make sure that the connectors are securely locked.
- Handling During Wiring (1 ) If a force is applied to the connection area between the terminal and connector by bending or pulling the cable after the wiring is completed, the connector contact part or connection area with the cable may be damaged, resulting in contact failure. Make sure that a stress (external force) as shown in the figure below is not applied to the connection area between the terminal and connector when routing and connecting cables or harnesses. (2 ) Do not perform cord wiring when power supply voltage is applied. Doing so may result in breakage.
- Design Precautions about this sensor A modulated-light type of the sensors is used. When designing, give proper consideration to the power supply and cable lengths used. The sensors are more easily affected than the sensors with Nonmodulated Light. Reasons for Interference from Power and Cable Length on the Sensors with Modulated Light An LED emitter is pulse-lighted to produce modulated light. A large current momentarily flows to the sensors in sync with this pulse timing. This causes a pulsating consumption current. A photoelectric sensor incorporates a capacitor with sufficient capacity, and is virtually unaffected by the pulse of the consump- tion current. With this sensor, however, it is difficult to have a capacitor with a sufficient capacity. Accordingly, when the cable length is long or depending on the type of power source, it may become impossible to keep up with the pulse of the consumption current and operation may become unstable. Countermeasures <Adding a Capacitor> Attach a capacitor of 10 µF min. to the wires as close as possi- ble to the sensor. (Use a capacitor with a dielectric strength that is at least twice the sensor's power supply voltage. Do not use tantalum capacitors. A short-circuit may cause the capaci- tor to ignite due to the large current flow.) Precautions for Correct Use Vcc ZD ZD : Zener diode 0.1 to 1 µFOUT GND Sensor Vcc D Relay OUT GND Sensor D External force External force External force Emitter (LB) Main circuit 10 µF min. Current Vcc OUT GND
12 VDC
<Extending Cable Length>
- Design the configuration so that the maximum cable length for the sensor is 2 m.
- When using a cable longer than 2 m, attach a capacitor (e.g., an aluminum electrolytic capacitor) with a capacity of 10 μF min. to the wires. The distance between the sensor and the capacitor must be within 2 m. Make sure that the total cable length is no longer than 5 m. To use a cable length longer than 5 m, use a PLC or other means to read the sensor output and then transmit the signals using a PLC's communications.
- Although cables are capable of being extended longer than 5 m, performance is likely to be affected by cable specifications and noise interference from adjacent cables and other devices. Voltage drops due to the resistance of the cable material itself will also influence performance. Therefore, factors such as the difference in voltage between the end of the cable and the sensor and noise levels, must be given full consideration. <Countermeasures for Switching Power Supplies>
- Take either of the following countermeasures as required if connecting a sensor to a switching power supply. (1)Attach a capacitor of 10 μ F min. to the wires as close as possible to the sensor. (Use a capacitor with a dielectric strength that is at least twice the sensor's power supply voltage. Do not use tantalum capacitors. A short-circuit may cause the capacitor to ignite due to the large current flow.) (2)Connect to the 0-V line of the power source or connect to the power source via a capacitor of approximately 0.47 μF to reduce the impedance of the mounting base to prevent inductive noise from entering the mounting base. (3)Connect the noise filter terminal (neutral terminal to ACG) of the switching power supply to the case (FG) and 0-V terminal of the power supply. <Countermeasures to Handle Inductive Noise> (4)Insert a plastic insulator of approximately 10 mm between the sensor and the mounting base. <Effects of Inductive Noise>
- When there is inductive noise in the sensor mounting base (metal), the sensor may enter the same state as light receiving. In this case, ensure that there is no electrical potential difference between the sensor 0 V terminal and the sensor mounting base (metal), or put a 0.47 μF capacitor between the 0 V terminal and the base (metal). <Effects When the Power Supply is Turned On> An output pulse may occur when the power supply is turned ON depending on the power supply and other conditions. Use the sensor in the stable ready-for-detection state reached in 100 ms after turning on the power supply. 2 m max.
10 µF min. Extension cable 2 m max. 10 µF min. Extension cable GC (0.47 µF) Switching Power Supplies Mounting base Sensor +V Mounting base Sensor Sensor Power Supplies G ACG FG Grounding Switching Power Supplies Input Power supplySensor Mounting base 0.47 µF 0 V
Please check each region's Terms & Conditions by region website. OMRON Corporation Device & Module Solutions Company Regional Contact Cat. No. E601-E1-02 0522 (1220) Americas Europe https://components.omron.com/us https://components.omron.com/eu Asia-Pacific China Korea Japan https://components.omron.com/kr https://components.omron.com/jp In the interest of product improvement, specifications are subject to change without notice. © OMRON Corporation 2018-2022 All Rights Reserved.