DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 10

Technical content

SMD, EIA case sizes 0402, 0603 and 0805, superior series Series/Type: Date: January 2010 © EPCOS AG 2010. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited.

Applications

Over-temperature protection of power components DC/DC converters SMPS Notebooks Home appliances Dimmers Electronic ballasts Automotive electronics Secondary protection of battery packs

Features

Qualification based on AEC-Q200 rev. C Suitable for reflow and wave soldering (up to 280°C) Fast and reliable response RoHS-compatible UL approval to UL1434 expected 2010 Lead-free tinned terminations Options Other Tsense or resistance values on request Delivery mode Blister tape (case size 0805) or cardboard tape (case sizes 0402 and 0603), 180-mm reel with 8-mm tape, taping to IEC 60286-3 Packing unit: 10.000 pcs. (case size 0402), 4.000 pcs. (case size 0805 and 0603) General technical data Max. operating voltage Vmax 32 V DC Minimum operating temperature (V ≤ Vmax) Tmin 40 °C Maximum operating temperature (V ≤ Vmax) Tmax 125 °C or Tsense,1 +25 °C whichever is higher Sensors Limit temperature sensors, EIA sizes 0402, 0603 and 0805 Superior series Preliminary data Page 2 of 10Please read Cautions and warnings and Important notes at the end of this document.

Electrical specifications and ordering codes RR (V ≤ Vmax) Ω ΔRR Tsense,1 (@ 4.7 kΩ ) Tsense,2 (@ 47 kΩ ) Ordering code EIA case size 0402 470 ±50 75 ±5 - B59421A0075A062 470 ±50 85 ±5 - B59421A0085A062 470 ±50 95 ±5 - B59421A0095A062 470 ±50 105 ±5 - B59421A0105A062 470 ±50 115 ±5 - B59421A0115A062 470 ±50 125 ±5 - B59421A0125A062 470 ±50 135 ±5 - B59421A0135A062 EIA case size 0603 470 ±50 85 ±5 100 ±7 B59641A0085A062 470 ±50 95 ±5 110 ±7 B59641A0095A062 470 ±50 105 ±5 120 ±7 B59641A0105A062 470 ±50 115 ±5 130 ±7 B59641A0115A062 470 ±50 125 ±5 140 ±7 B59641A0125A062 470 ±50 135 ±5 150 ±7 B59641A0135A062 470 ±50 145 ±5 - B59641A0145A062 Sensors Limit temperature sensors, EIA sizes 0402, 0603 and 0805 Superior series Preliminary data Page 3 of 10Please read Cautions and warnings and Important notes at the end of this document.

Electrical specifications and ordering codes RR (V ≤ Vmax) Ω ΔRR Tsense,1 R (Tsense,1 5°C) kΩ R (Tsense,1 +5°C) kΩ R (Tsense,1 +15°C) kΩ Ordering code EIA case size 0805 680 ±50 70 ≤ 5.7 ≥ 5.7 - B59721A0070A062 680 ±50 80 ≤ 5.7 ≥ 5.7 - B59721A0080A062 680 ±50 90 ≤ 5.5 ≥ 13.3 ≥ 40 B59721A0090A062 680 ±50 100 ≤ 5.5 ≥ 13.3 ≥ 40 B59721A0100A062 680 ±50 110 ≤ 5.5 ≥ 13.3 ≥ 40 B59721A0110A062 680 ±50 120 ≤ 5.5 ≥ 13.3 ≥ 40 B59721A0120A062 680 ±50 130 ≤ 5.5 ≥ 13.3 ≥ 40 B59721A0130A062 Sensors Limit temperature sensors, EIA sizes 0402, 0603 and 0805 Superior series Preliminary data Page 4 of 10Please read Cautions and warnings and Important notes at the end of this document.

Dimensional drawings in mm EIA case size 0402 Solder pad EIA case size 0603 Solder pad EIA case size 0805 Solder pad Recommended maximum dimensions (mm) Sensors Limit temperature sensors, EIA sizes 0402, 0603 and 0805 Superior series Preliminary data Page 5 of 10Please read Cautions and warnings and Important notes at the end of this document.

EPCOS thermistors are designed for specific applications and should not be used for purposes not identified in our specifications, application notes and data books unless otherwise agreed with EPCOS during the design-in-phase. Ensure suitability of thermistor through reliability testing during the design-in phase. The ther- mistors should be evaluated taking into consideration worst-case conditions. Storage Store thermistors only in original packaging. Do not open the package before storage. Storage conditions in original packaging: storage temperature 25 °C ... +45 °C, relative hu- midity ≤75% annual mean, maximum 95%, dew precipitation is inadmissible. Avoid contamination of thermistors surface during storage, handling and processing. Avoid storage of thermistor in harmful environment with effect on function on long-term opera- tion (examples given under operation precautions). Use thermistor within the following period after delivery: Through-hole devices (housed and leaded PTCs): 24 months Motor protection sensors, glass-encapsulated sensors and probe assemblies: 24 months Telecom pair and quattro protectors (TPP, TQP): 24 months Leadless PTC thermistors for pressure contacting: 12 months Leadless PTC thermistors for soldering: 6 months SMDs in EIA sizes 3225 and 4032, and for PTCs with metal tags: 24 months SMDs in EIA sizes 0402, 0603, 0805 and 1210: 12 months Handling PTCs must not be dropped. Chip-offs must not be caused during handling of PTCs. Components must not be touched with bare hands. Gloves are recommended. Avoid contamination of thermistor surface during handling. Soldering (where applicable) Use rosin-type flux or non-activated flux. Insufficient preheating may cause ceramic cracks. Rapid cooling by dipping in solvent is not recommended. Complete removal of flux is recommended. Standard PTC heaters are not suitable for soldering. Sensors Limit temperature sensors, EIA sizes 0402, 0603 and 0805 Superior series Preliminary data Page 6 of 10Please read Cautions and warnings and Important notes at the end of this document.

Electrode must not be scratched before/during/after the mounting process. Contacts and housing used for assembly with thermistor have to be clean before mounting. Es- pecially grease or oil must be removed. When PTC thermistors are encapsulated with sealing material, the precautions given in chapter "Mounting instructions", "Sealing and potting" must be observed. When the thermistor is mounted, there must not be any foreign body between the electrode of the thermistor and the clamping contact. The minimum force of the clamping contacts pressing against the PTC must be 10 N. During operation, the thermistor’s surface temperature can be very high. Ensure that adjacent components are placed at a sufficient distance from the thermistor to allow for proper cooling at the thermistors. Ensure that adjacent materials are designed for operation at temperatures comparable to the surface temperature of thermistor. Be sure that surrounding parts and materials can withstand this temperature. Avoid contamination of thermistor surface during processing. Operation Use thermistors only within the specified temperature operating range. Use thermistors only within the specified voltage and current ranges. Environmental conditions must not harm the thermistors. Use thermistors only in normal at- mospheric conditions. Avoid use in deoxidizing gases (chlorine gas, hydrogen sulfide gas, am- monia gas, sulfuric acid gas etc), corrosive agents, humid or salty conditions. Contact with any liquids and solvents should be prevented. Be sure to provide an appropriate fail-safe function to prevent secondary product damage caused by abnormal function (e.g. use VDR for limitation of overvoltage condition). Sensors Limit temperature sensors, EIA sizes 0402, 0603 and 0805 Superior series Preliminary data Page 7 of 10Please read Cautions and warnings and Important notes at the end of this document.

Ir,oil Residual currrent in oil (for level sensors) Ir,air Residual currrent in air (for level sensors) IRMS Root-mean-square value of current IS Switching current ISmax Maximum switching current LCT Lower category temperature N Number (integer) Nc Operating cycles at Vmax, charging of capacitor Nf Switching cycles at Vmax, failure mode P Power P25 Maximum power at 25 °C Pel Electrical power Pdiss Dissipation power Rmin Minimum resistance RR Rated resistance ΔRR Tolerance of RR RP Parallel resistance RPTC PTC resistance Rref Reference resistance RS Series resistance R25 Resistance at 25 °C R25,match Resistance matching per reel/ packing unit at 25 °C ΔR25 Tolerance of R25 T Temperature t Time TA Ambient temperature ta Thermal threshold time TC Ferroelectric Curie temperature Sensors Limit temperature sensors, EIA sizes 0402, 0603 and 0805 Superior series Preliminary data Page 8 of 10Please read Cautions and warnings and Important notes at the end of this document.

tE Settling time (for level sensors) TR Rated temperature Tsense Sensing temperature Top Operating temperature TPTC PTC temperature tR Response time Tref Reference temperature TRmin Temperature at minimum resistance tS Switching time Tsurf Surface temperature UCT Upper category temperature V or Vel Voltage (with subscript only for distinction from volume) VRMS Root-mean-square value of voltage VBD Breakdown voltage Vins Insulation test voltage Vlink,max Maximum link voltage Vmax Maximum operating voltage Vmax,dyn Maximum dynamic (short-time) operating voltage Vmeas Measuring voltage Vmeas,max Maximum measuring voltage VR Rated voltage VPTC Voltage drop across a PTC thermistor α Temperature coefficient Δ Tolerance, change δth Dissipation factor τth Thermal cooling time constant λ Failure rate Lead spacing (in mm) Abbreviations / Notes Surface-mount devices * To be replaced by a number in ordering codes, type designations etc. + To be replaced by a letter All dimensions are given in mm. The commas used in numerical values denote decimal points. Sensors Limit temperature sensors, EIA sizes 0402, 0603 and 0805 Superior series Preliminary data Page 9 of 10Please read Cautions and warnings and Important notes at the end of this document.

The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application . These statements are based on our knowledge of typical re- quirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application . As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incum- bent on the customer to check and decide whether an EPCOS product with the properties de- scribed in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified . In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health (e.g. in accident prevention or lifesaving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of an electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous). Useful information on this will be found in our Ma- terial Data Sheets on the Internet (www.epcos.com/material). Should you have any more de- tailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time . The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products . Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the fore- going for customer-specific products. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current ver- sion of the "General Terms of Delivery for Products and Services in the Electrical In- dustry" published by the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSMP, CSSP, CTVS, DeltaCap, DigiSiMic, DSSP, MiniBlue, MiniCell, MKK, MLSC, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks. Important notes Page 10 of 10