B48611A5903Q012 EPCOS | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

The following products presented in this data sheet are being withdrawn. For further information please contact your nearest EPCOS sales office, which will also support you in selecting a suitable substitute. The addresses of our worldwide sales network are presented at www.epcos.com/sales. Ordering Code Substitute ProductDate of Withdrawal Deadline Last Orders Last Shipments B48611A5903Q012 2006-09-26 2006-12-31 2007-03-31

Features

Passive cell voltage balancing Case material polyethylene, black Power type 12 serial single cells of 110 F Maintenance-free Short-circuit-proof Fast-acting blowout fuse 20 A Dimensional drawing Dimensions in mm Electrical specifications 1) DCC: discharging with constant current. 2) Requirements: ΔC/CR ≤ 30%, ESR ≤ 2 times of specified limit, Ileak ≤ 2 times of initial value. 3) Requirements: ΔC/CR ≤ 30%, ESR ≤ 2 times of specified limit, Ileak ≤ 2 times of initial value (1 cycle: charging to VR, 30 s rest, discharging to VR/2, 30 s rest). Rated capacitance (TA = 25 °C; DCC) 1) CR 9 F Tolerance of CR 10/+30 % Rated voltage (T A = 25 °C) VR 28 V Capacity 70 mAh Specific power (P spez = 0.12 VR2 / ESRDC / m) 1.0 kW/kg Specific power (P spez = 0.12 VR2 / ESRDC / v) 0.9 kW/l Stored energy (V = V R) E 3528 J Specific energy (V = V R) 1.3 Wh/kg Specific energy (V = V R) 1.1 Wh/l Surge voltage Vsurge 32 V Maximum series resistance (T A = 25 °C; 1 kHz) ESR 60 mΩ Maximum series resistance (T A = 25 °C; 50 mHz) ESRDC 120 mΩ Mass m 0.75 kg Volume v 0.9 l Operating temperature range Top 30/+70 °C Storage temperature (V = 0 V) Tst 40/+70 °C Lifetime (hours) 2) (TA = 25 °C; V = VR) 90000 h Lifetime (cycles) 3) (TA = 25 °C; I = 10 A) 500000 cycles UltraCap B48611A5903Q012 Module, 9 F/ 28 V Page 2 of 4Please read Cautions and warnings and Important notes at the end of this document.

Transportation of hazardous substances Any shipment of UltraCaps from customers, whatever the means of transportation, must be provided with a declaration of hazardous substances and packed accordingly if the quantity of electrolyte per item packed exceeds 0.5 liters. We will be glad to assist you in clarifying details. For transportation on streets in Europe detailed regulations are given in ADR/RID / UN 1648 Acetonitrile. Customers outside the European Union should refer to their local regulations. For transportation by sea freight please refer to IMDG regulations, for transportation by air freight please refer to IATA regulations. Waste regulations UltraCaps must be disposed of according to the European waste catalog, code number 160213 "Waste from electrical and electronic products ". In addition, we request customers to consult their refuse disposal facilities and local or national authorities. Users outside of the European Union should refer to the waste disposal regulations of their own particular country. Warning Do not put into fire! Do not open the capacitor! To avoid health and fire hazards, do not operate the capacitor beyond the voltage or temperature limits given in the data sheet. Any excess may also result in a reduction of lifetime. UltraCap B48611A5903Q012 Module, 9 F/ 28 V Page 3 of 4Please read Cautions and warnings and Important notes at the end of this document.

The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical re- quirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incum- bent on the customer to check and decide whether an EPCOS product with the properties de- scribed in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of passive electronic compon- ents or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applica- tions requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of a passive electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of a passive electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as “hazardous”). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an or- der. We also reserve the right to discontinue production and delivery of products. Con- sequently, we cannot guarantee that all products named in this publication will always be available. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current ver- sion of the “General Terms of Delivery for Products and Services in the Electrical In- dustry” published by the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, CeraDiode, CSSP , PhaseCap, PhaseMod, SilverCap, SIFI, SIMID, SIKOREL, SIOV, SIP5D, SIP5K, TOPcap, UltraCap, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks. Important Notes Page 4 of 4