Features
- Single and Three Phase Circuits
- 3 Different Circuits to Choose from
- Up to 1600 Volt Blocking Standard
- UL Recognized E72445 Symbol Single Phase Three Phase Maximum DC Output Current (Tc = 85°C) ID 35A 50A Maximum Voltage Drop @ Amps Peak VF 1.25V @ 35A 1.35V @ 50A Operating Junction Temperature Range TJ -40 - 125°C -40 - 125°C Repetitive Peak Reverse Voltage (AC Line Nominal) [Vpk] 600 (240 VAC) 1200 (480 VAC) Maximum Non-Repetitive Surge Current (1/2 Cycle, 60 Hz) ITSM 600 600 Maximum I²t for Fusing (t=8.3ms) [A²sec] I2t 1500 1500 Maximum Thermal Resistance, Junction to Ceramic Base per Chip [°C/W] RJC 0.9°C/W 0.9°C/W Isolation Voltage [Vrms] VISOL 2500 Description Parameters Weight (typical) 1.5 oz (42.5g) SPECIFICATIONS Output General
www.sensata.com Page 2 Copyright © 2024 Sensata Technologies, Inc. MECHANICAL SPECIFICATIONS CIRCUIT DIAGRAMS *Tolerances: ±0.02 in / 0.5 mm All dimensions are in: inches [millimeters] B48-2B48-2T B48-2B48-2T B48-2T B48-2 2.50 (63.5) 1.90 (48.2) 2.50 (63.5) 1.90 (48.2) .25 (6.3) MOUNTING HOLE/SLOT 0.21 (5.2) DIA. TERMINAL TERMINAL MOUNTING HOLE/SLOT 0.21 (5.2) DIA. 1.25 [31.7] 1.00 [25.4] .25 (6.3) 1.06 [26.9] .50 [12.9] .55 [14.0] .10 [2.5] .10 [2.5] .78 [19.7]
www.sensata.com CONTACT US Americas +1 (877) 502 5500 sales.crydom@sensata.com Europe, Middle East & Africa +44 (1202) 416170 ssr-info.eu@sensata.com Asia Pacific sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 Copyright © 2024 Sensata Technologies, Inc. Datasheets provided by Sensata Technologies, Inc., its subsidiaries and/or affiliates (“Sensata”) are solely intended to assist third parties (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, valuation, and judgment in designing Buyer’s systems and products. Sensata datasheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular datasheet. Sensata may make corrections, enhancements, improvements, and other changes to its datasheets or components without notice. Buyers are authorized to use Sensata datasheets with the Sensata component(s) identified in each particular datasheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATASHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATASHEETS OR USE OF THE DATASHEETS, EXPRESS, IMPLIED, OR STATUTORY , INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY , FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATASHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com. SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY , AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA Rev.04/23/2024 ECN 20395 FDE-07-01 Rev. B B48 2 C -2T Series B48 Circuit Type 2 3 5 (see schematic diagrams) AC Line Voltage C: 600 (240VAC) F: 1200 (480VAC) Case Style -2T: Standard -2: With Isolation Barriers AVAILABLE OPTIONS Example : B482C-2T NOTE: Not all combinations are available. Consult factory for information on the availability of a specific part number. Required for valid part number For options only and not required for valid part number WARNINGS E72445 AGENCY APPROVALS & CERTIFICATIONS RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE
- The product’s side panels may be hot, allow the product to cool before touching
- Follow proper mounting instructions including torque values
- Do not allow liquids or foreign objects to enter this product Failure to follow these instructions can result in serious injury, or equipment damage. HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
- Disconnect all power before installing or working with this equipment
- Verify all connections and replace all covers before turning on power Failure to follow these instructions will result in death or serious injury.