AVQ100 ADVANCEDENERGY | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 5

Technical content

©2020 Advanced Energy Industries, Inc. ARTESYN AVQ100 WIDE INPUT

100 Watt Quarter Brick DC-DC Converter

Total Power:

100 Watts

(3V3 @ 25 A) Input Voltage: 18 - 36 V # of Outputs: Single (3V3 nom) DATA SHEETAdvanced Energy's Artesyn AVQ100-36S3V3 is a single output DC/DC converter with standard quarterbrick outline and pin configuration. It delivers up to 25A output current with 3.3V output voltage. SPECIAL FEATURES  100 W continuous power  High efficiency: 90 %  18-60 Vdc wide range Telecom input range  Baseplate optimised for contact cooling or heatsink mounting  Open frame version optimised for aircooling  Low ripple and noise  Fixed switching frequency  High capacitive load capability  Pre-bias start-up capability  High reliability  RoHS 6/6 compliant  UL94 V-0 materials  DOSA footprint compliant  Two year warranty (consult factory for extended terms) SAFETY  TUV/CE 62368-1  UL/cUL 60950-1

2 advancedenergy.com AVQ100-WIDE-INPUT ELECTRICAL SPECIFICATIONS ENVIRONMENTAL SPECIFICATIONS Input Input ra nge 18 - 60 VDC Input surge 80 V / 100 mSec Input UVLO Turn-on: 17.7 Vdc nom Turn-off: 15.1 Vdc nom Hysteresis: 1.6 Vdc Input currrent maximum 6 Amps Efficiency (48 Vin, 25 °C ambient) 90% at 3V3 peak efficiency I/O insulation I/O isolation Basic insulation

1500 Vdc

Output voltage 3V3 nominal set point Output voltage regulation 3V3 ± 1% Output current maximum 25 A @ 3V3 output voltage Noise & ripple 40 mV pk-pk max (@ 3V3) Overtemperature protection Baseplate: 110 °C baseplate Open frame: 130 °C hotspot Overvoltage protection Method / OVP operation

4.2 V nominal

35 A nominal

Enable Positive or Negative option Output voltage trim range -20% to +10% Vout Switching frequency 300 KHz Storage temperature -40 °C to +105 °C Ambient temperature -40 °C to +85 °C Baseplate operating temperature -40 °C to +100 °C (no power derating) MTBF 1 million hours target

advancedenergy.com 3 AVQ100-WIDE-INPUT

ORDERING INFORMATION

Model number Input voltage Output voltage set-point Output Current Efficiency AVQ100-36S3V3-6L 18 - 60 Vdc 3V3 dc 25 A max 90% full load AVQ100-36S3V3B-6L 18 - 60 Vdc 3V3 dc 25 A max 90% full load “-6” = 3.8 mm pin length “-L” = RoHS 6/6 compliant MECHANICAL DRAWINGS

4 advancedenergy.com AVQ100-WIDE-INPUT PIN LENGTH OPTION PIN ASSIGNMENTS Device Code Suffix L -4 4.8 mm+/-0.5 mm -6 3.8 mm+/-0.5 mm NONE 5.8 mm+/-0.5 mm Pin # Function 1 +V in 5 -Sense

2 Enable 6 Trim

Notes: 1. All specifications are subject to change without notice. Mechanical drawings are for reference only. 2. Warranty: 2 years 3. Label and logo appearance may vary from what is shown on mechanical drawings.

ENG-AVQ100-WIDE-INPUT-235-01 12.16 For international contact information, visit advancedenergy .com. powersales@aei.com (Sales Support) productsupport.ep@aei.com (Technical Support) +1 888 412 7832 ABOUT ADVANCED ENERGY Advanced Energy (AE) has devoted more than three decades to perfecting power for its global customers. AE designs and manufactures highly engineered, precision power conversion, measurement and control solutions for mission-critical applications and processes. Our products enable customer innovation in complex applications for a wide range of industries including semiconductor equipment, industrial, manufacturing, telecommunications, data center computing, and medical. With deep applications know-how and responsive service and support across the globe, we build collaborative partnerships to meet rapid technological developments, propel growth for our customers, and innovate the future of power. Specifications are subject to change without notice. Not responsible for errors or omissions. ©2020 Advanced Energy Industries, Inc. All rights reserved. Advanced Energy®, AE® and Artesyn™ are U.S. trademarks of Advanced Energy Industries, Inc.