ATV71HD37N4Z SCHNEIDER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 14

Technical content

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Aug 9, 2019 Product data sheet Characteristics ATV71HD37N4Z variable speed drive ATV71 - 37kW-50HP - 480V - EMC filter-w/o graphic terminal Product availability: Non-Stock - Not normally stocked in distribution facility Main Range of product Altivar 71 Product or component type Variable speed drive Product specific applica- tion Complex, high-power machines Component name ATV71 Motor power kW 37 kWat 380...480 V 3 phases Motor power hp 50 hpat 380...480 V 3 phases Motor cable length <= 328.08 ft (100 m) Shielded cable <= 656.17 ft (200 m) Unshielded cable Phase 3 phases Line current 69 Afor 480 V 3 phases 37 kW / 50 hp

84 Afor 380 V 3 phases 37 kW / 50 hp

Assembly style With heat sink Variant Without remote graphic terminal Apparent power 55.3 kVAat 380 V 3 phases 37 kW / 50 hp Prospective line Isc <= 22 kA, 3 phases Nominal output current 65 Aat 2.5 kHz 460 V 3 phases 37 kW / 50 hp 79 Aat 2.5 kHz 380 V 3 phases 37 kW / 50 hp Maximum transient cur- rent

130 Afor 2 s 3 phases 37 kW / 50 hp

118.5 Afor 60 s 3 phases 37 kW / 50 hp

Output frequency 0.1...599 Hz Nominal switching fre- quency 2.5 kHz Switching frequency 1...16 kHz adjustable 2.5...16 kHz with derating factor Asynchronous motor control profile ENA (Energy adaptation) system for unbalanced loads Flux vector control (FVC) with sensor (current vec- tor) Sensorless flux vector control (SFVC) (voltage or current vector) Voltage/frequency ratio (2 or 5 points) Type of polarization No impedance Modbus Complementary Product destination Asynchronous motors Synchronous motors Power supply voltage limits 323...528 V Power supply frequency limits 47.5...63 Hz Speed range 1...100 asynchronous motor in open-loop mode, without speed feedback 1...50 synchronous motor in open-loop mode, without speed feedback 1...1000 asynchronous motor in closed-loop mode with encoder feedback Speed accuracy +/- 0.01 % of nominal speed 0.2 Tn to Tn torque variation in closed-loop mode with encoder feedback +/- 10 % of nominal slip 0.2 Tn to Tn torque variation without speed feedback Torque accuracy +/- 15 % in open-loop mode, without speed feedback +/- 5 % in closed-loop mode with encoder feedback

Transient overtorque 220 % of nominal motor torque +/- 10 %for 2 s 170 % of nominal motor torque +/- 10 %for 60 s every 10 minutes Braking torque <= 150 % with braking or hoist resistor 30 % without braking resistor Synchronous motor control profile Vector control without speed feedback Regulation loop Adjustable PI regulator Motor slip compensation Adjustable Automatic whatever the load Not available in voltage/frequency ratio (2 or 5 points) Suppressable Diagnostic 1 LED red presence of drive voltage Output voltage <= power supply voltage Insulation Electrical between power and control Type of cable for mounting in an enclosure With a NEMA Type1 kit: 3-strand UL 508 cableat 104 °F (40 °C), copper 75 °C PVC With an IP21 or an IP31 kit: 3-strand IEC cableat 104 °F (40 °C), copper 70 °C PVC Without mounting kit: 1-strand IEC cableat 113 °F (45 °C), copper 70 °C PVC Without mounting kit: 1-strand IEC cableat 113 °F (45 °C), copper 90 °C XLPE/ EPR mm² / AWG 14 L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB terminal 50 mm² / AWG 1/0 Tightening torque L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB 106.19 lbf.in (12 N.m) / 102.2 lb.in N.m) Supply Internal supply for reference potentiometer (1 to 10 kOhm), 10.5 V DC +/- 5 %, <= 10 mAfor overload and short-circuit protection Internal supply, 24 V DC, voltage limits 21...27 V, <= 200 mAfor overload and short-circuit protection Analogue input number 2 Analogue input type AI1-/Al1+ bipolar differential voltage +/- 10 V DC, input voltage 24 V max, resolu- tion 11 bits + sign AI2 software-configurable current 0...20 mA, impedance 242 Ohm, resolution 11 bits AI2 software-configurable voltage 0...10 V DC, input voltage 24 V max, im- pedance 30000 Ohm, resolution 11 bits Input sampling time AI1-/Al1+ 2 ms, +/- 0.5 ms analog input(s) Al2 2 ms, +/- 0.5 ms analog input(s) LI1...LI5 2 ms, +/- 0.5 ms discrete input(s) LI6 (if configured as logic input) 2 ms, +/- 0.5 ms discrete input(s) Response time <= 100 ms in STO (Safe Torque Off) AO1 2 ms, tolerance +/- 0.5 ms analog output(s) R1A, R1B, R1C 7 ms, tolerance +/- 0.5 ms discrete output(s) R2A, R2B 7 ms, tolerance +/- 0.5 ms discrete output(s) AI2 +/- 0.6 % for a temperature variation 60 °C AO1 +/- 1 % for a temperature variation 60 °C Linearity error AI1-/Al1+, AI2 +/- 0.15 % of maximum value AO1 +/- 0.2 % Analogue output number 1 Analogue output type AO1 software-configurable current 0...20 mA, impedance 500 Ohm, resolution 10 bits AO1 software-configurable logic output 10 V <= 20 mA AO1 software-configurable voltage 0...10 V DC, impedance 470 Ohm, resolution 10 bits Discrete output number 2 Discrete output type R1A, R1B, R1C configurable relay logic NO/NC, electrical durability 100000 cy- cles R2A, R2B configurable relay logic NO, electrical durability 100000 cycles Minimum switching current Configurable relay logic 3 mAat 24 V DC Maximum switching current R1, R2 on resistive load, 5 Aat 250 V AC, cos phi = 1, R1, R2 on resistive load, 5 Aat 30 V DC, cos phi = 1, R1, R2 on inductive load, 2 Aat 250 V AC, cos phi = 0.4, R1, R2 on inductive load, 2 Aat 30 V DC, cos phi = 0.4, Discrete input number 7

Discrete input type LI6: switch-configurable 24 V DC with level 1 PLC, impedance: 3500 Ohm PWR: safety input 24 V DC, impedance: 1500 Ohm conforming to ISO 13849-1 level d LI1...LI5: programmable 24 V DC with level 1 PLC, impedance: 3500 Ohm LI6: switch-configurable PTC probe 0...6, impedance: 1500 Ohm Discrete input logic LI1...LI5 positive logic (source), < 5 V (state 0), > 11 V (state 0) LI1...LI5 negative logic (sink), > 16 V (state 0), < 10 V (state 0) LI6 (if configured as logic input) positive logic (source), < 5 V (state 0), > 11 V (state 0) LI6 (if configured as logic input) negative logic (sink), > 16 V (state 0), < 10 V (state 0) Acceleration and deceleration ramps Automatic adaptation of ramp if braking capacity exceeded, by using resistor Linear adjustable separately from 0.01 to 9000 s S, U or customized Braking to standstill By DC injection Protection type Drive against exceeding limit speed Drive against input phase loss Drive break on the control circuit Drive input phase breaks Drive line supply overvoltage Drive line supply undervoltage Drive overcurrent between output phases and earth Drive overheating protection Drive overvoltages on the DC bus Drive short-circuit between motor phases Drive thermal protection Motor motor phase break Motor power removal Motor thermal protection Insulation resistance > 1 mOhm at 500 V DC for 1 minute to earth Frequency resolution Analog input 0.024/50 Hz Display unit 0.1 Hz Communication port protocol CANopen Modbus Connector type 1 RJ45 Modbus on front face

1 RJ45 Modbus on terminal

Male SUB-D 9 on RJ45 CANopen Physical interface 2-wire RS 485 Modbus Transmission frame RTU Modbus Transmission rate 20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps CANopen 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps Modbus on terminal 9600 bps, 19200 bps Modbus on front face Data format 8 bits, 1 stop, even parity Modbus on front face 8 bits, odd even or no configurable parity Modbus on terminal Number of addresses 1...247 Modbus 1...127 CANopen Method of access Slave CANopen Marking CE Operating position Vertical +/- 10 degree Height 21.65 in (550 mm) Depth 10.47 in (266 mm) Width 9.45 in (240 mm) Product weight 81.57 lb(US) (37 kg) Option card CC-Link communication card Controller inside programmable card DeviceNet communication card Ethernet/IP communication card Fipio communication card I/O extension card Interbus-S communication card Interface card for encoder Modbus Plus communication card Modbus TCP communication card Modbus/Uni-Telway communication card Overhead crane card Profibus DP communication card Profibus DP V1 communication card

Noise level 64 dB conforming to 86/188/EEC Dielectric strength 3535 V DC between earth and power terminals

5092 V DC between control and power terminals

Electromagnetic compatibility Conducted radio-frequency immunity test conforming to IEC 61000-4-6 level 3 Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 level 4 Electrostatic discharge immunity test conforming to IEC 61000-4-2 level 3 Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 level 3 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11 1.2/50 µs - 8/20 µs surge immunity test conforming to IEC 61000-4-5 level 3 Standards EN 55011 class A group 2 EN 61800-3 environments 1 category C3 EN 61800-3 environments 2 category C3 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 60721-3-3 class 3C1 IEC 60721-3-3 class 3S2 UL Type 1 Product certifications CSA C-Tick NOM 117 UL Pollution degree 2 conforming to EN/IEC 61800-5-1 3 conforming to UL 840 IP degree of protection IP20 on upper part without blanking plate on cover conforming to EN/IEC 60529 IP20 on upper part without blanking plate on cover conforming to EN/IEC 61800-5-1 IP21 conforming to EN/IEC 60529 IP21 conforming to EN/IEC 61800-5-1 IP41 on upper part conforming to EN/IEC 60529 IP41 on upper part conforming to EN/IEC 61800-5-1 IP54 on lower part conforming to EN/IEC 60529 IP54 on lower part conforming to EN/IEC 61800-5-1 Vibration resistance 1.5 mm peak to peak (f = 3...13 Hz) conforming to EN/IEC 60068-2-6 1 gn (f = 13...200 Hz) conforming to EN/IEC 60068-2-6 Shock resistance 15 gn 11 ms conforming to EN/IEC 60068-2-27 Relative humidity 5...95 % without condensation conforming to IEC 60068-2-3 5...95 % without dripping water conforming to IEC 60068-2-3 Operating altitude <= 3280.84 ft (1000 m) without derating Ordering and shipping details Category 22131 - ATV71 - 7.5 THRU 50HP Discount Schedule CP4C GTIN 00785901643333 Nbr. of units in pkg. 1 Package weight(Lbs) 64.900000000000006 Returnability N Country of origin IN Offer Sustainability Sustainable offer status Green Premium product RoHS (date code: YYWW) Compliant - since 0946 - Schneider Electric declaration of conformity Schnei- der Electric declaration of conformity REACh Reference contains SVHC above the threshold - Go to CaP for more details- Go to CaP for more details Product environmental profile Available Product Environmental Profile Product end of life instructions Available California proposition 65 WARNING: This product can expose you to chemicals including:

  • - - - - - - Substance 1 Lead and lead compounds, which is known to the State of California to cause can- cer and birth defects or other reproductive harm. - - - - - - - Substance 2 Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. - - - - - - - More information For more information go to www.p65warnings.ca.gov Contractual warranty Warranty period 18 months

Variable Speed Drives without Graphic Display Terminal Dimensions without Option Card Dimensions in mm a b c G H K Ø 240 550 230 206 531.5 11 6 Dimensions in in. a b c G H K Ø Dimensions with 1 Option Card (1) Dimensions in mm a c1 G H K Ø 240 233 206 531.5 11 6 Dimensions in in. a c1 G H K Ø (1) Option cards: I/O extension cards, communication cards or "Controller Inside” programmable card.

Dimensions with 2 Option Cards (1) Dimensions in mm a c2 G H K Ø 240 276 206 531.5 11 6 Dimensions in in. a c2 G H K Ø (1) Option cards: I/O extension cards, communication cards or "Controller Inside” programmable card.

Depending on the conditions in which the drive is to be used, its installation will require certain precautions and the use of appropriate accessories. Install the unit vertically:

  • Avoid placing it close to heating elements
  • Leave sufficient free space to ensure that the air required for cooling purposes can circulate from the bottom to the top of the unit. Clearance Mounting Types Type A Mounting Type B Mounting Type C Mounting By removing the protective blanking cover from the top of the drive, the degree of protection for the drive becomes IP 20. The protective blanking cover may vary according to the drive model (refer to the user guide). The protective blanking cover must be removed from ATV 71P•••N4Z drives when they are mounted in a dust and damp proof enclosure. Specific Recommendations for Mounting the Drive in an Enclosure Ventilation To ensure proper air circulation in the drive:
  • Fit ventilation grilles.
  • Ensure that there is sufficient ventilation. If there is not, install a forced ventilation unit with a filter. The openings and/or fans must provide a flow rate at least equal to that of the drive fans (refer to the product characteristics).
  • Use special filters with IP 54 protection.
  • Remove the blanking cover from the top of the drive. Dust and Damp Proof Metal Enclosure (IP 54) The drive must be mounted in a dust and damp proof enclosure in certain environmental conditions: dust, corrosive gases, high humidity with risk of condensation and dripping water, splashing liquid, etc. This enables the drive to be used in an enclosure where the maximum internal temperature reaches 50°C.

Wiring Diagram Conforming to Standards EN 954-1 Category 1, IEC/EN 61508 Capacity SIL1, in Stopping Category 0 According to IEC/EN 60204-1 Three-Phase Power Supply with Upstream Breaking via Contactor A1 ATV71 drive KM1 Contactor L1 DC choke Q1 Circuit-breaker Q2 GV2 L rated at twice the nominal primary current of T1 Q3 GB2CB05 S1, XB4 B or XB5 A pushbuttons T1 100 VA transformer 220 V secondary (1) Line choke (three-phase); mandatory for ATV71HC11Y…HC63Y drives (except when a special transformer is used (12-pulse)). (2) For ATV71HC40N4 drives combined with a 400 kW motor, ATV71HC50N4 and ATV71HC40Y…HC63Y, refer to the power terminal connections diagram. (3) Fault relay contacts. Used for remote signalling of the drive status. (4) Connection of the common for the logic inputs depends on the positioning of the SW1 switch. The above diagram shows the internal power supply switched to the “source” position (for other connection types, refer to the user guide). (5) There is no PO terminal on ATV71HC11Y…HC63Y drives. (6) Optional DC choke for ATV71H•••M3, ATV71HD11M3X…HD45M3X, ATV71•075N4…•D75N4 and ATV71P•••N4Z drives. Connected in place of the strap between the PO and PA/+ terminals. For ATV71HD55M3X, HD75M3X, ATV71HD90N4…HC50N4 drives, the choke is supplied with the drive; the customer is responsible for connecting it. (7) Software-configurable current (0…20 mA) or voltage (0…10 V) analog input. (8) Reference potentiometer. All terminals are located at the bottom of the drive. Fit interference suppressors on all inductive circuits near the drive or connected on the same circuit, such as relays, contactors, solenoid valves, fluorescent lighting, etc. Wiring Diagram Conforming to Standards EN 954-1 Category 1, IEC/EN 61508 Capacity SIL1, in Stopping Category 0 According to IEC/EN 60204-1

Three-Phase Power Supply with Downstream Breaking via Switch Disconnector A1 ATV71 drive L1 DC choke Q1 Circuit-breaker Q2 Switch disconnector (Vario) (1) Line choke (three-phase), mandatory for ATV71HC11Y…HC63Y drives (except when a special transformer is used (12-pulse)). (2) For ATV71HC40N4 drives combined with a 400 kW motor, ATV71HC50N4 and ATV71HC40Y…HC63Y, refer to the power terminal connections diagram. (3) Fault relay contacts. Used for remote signalling of the drive status. (4) Connection of the common for the logic inputs depends on the positioning of the SW1 switch. The above diagram shows the internal power supply switched to the “source” position (for other connection types, refer to the user guide). (5) There is no PO terminal on ATV71HC11Y…HC63Y drives. (6) Optional DC choke for ATV71H•••M3, ATV71HD11M3X…HD45M3X, ATV71•075N4…•D75N4 and ATV71P•••N4Z drives. Connected in place of the strap between the PO and PA/+ terminals. For ATV71HD55M3X, HD75M3X, ATV71HD90N4…HC50N4 drives, the choke is supplied with the drive; the customer is responsible for connecting it. (7) Software-configurable current (0…20 mA) or voltage (0…10 V) analog input. (8) Reference potentiometer. All terminals are located at the bottom of the drive. Fit interference suppressors on all inductive circuits near the drive or connected on the same circuit, such as relays, contactors, solenoid valves, fluorescent lighting, etc. Wiring Diagram Conforming to Standards EN 954-1 Category 3, IEC/EN 61508 Capacity SIL2, in Stopping Category 0 According to IEC/EN 60204-1

Three-Phase Power Supply, Low Inertia Machine, Vertical Movement A1 ATV71 drive A2 Preventa XPS AC safety module for monitoring emergency stops and switches. One safety module can manage the “Power Removal” function for several drives on the same machine. In this case, each drive must connect its PWR terminal to its + 24 V via the safety contacts on the XPS AC module. These contacts are independent for each drive. F1 Fuse L1 DC choke Q1 Circuit-breaker S1 Emergency stop button with 2 contacts S2 XB4 B or XB5 A pushbutton (1) Power supply: 24 Vdc or Vac, 48 Vac, 115 Vac, 230 Vac. (2) S2: resets XPS AC module on power-up or after an emergency stop. ESC can be used to set external starting conditions. (3) Requests freewheel stopping of the movement and activates the “Power Removal” safety function. (4) Line choke (three-phase), mandatory for and ATV71HC11Y…HC63Y drives (except when a special transformer is used (12-pulse)). (5) The logic output can be used to signal that the machine is in a safe stop state. (6) For ATV71HC40N4 drives combined with a 400 kW motor, ATV71HC50N4 and ATV71HC40Y…HC63Y, refer to the power terminal connections diagram. (7) Fault relay contacts. Used for remote signalling of the drive status. (8) Connection of the common for the logic inputs depends on the positioning of the SW1 switch. The above diagram shows the internal power supply switched to the “source” position (for other connection types, refer to the user guide). (9) Standardized coaxial cable, type RG174/U according to MIL-C17 or KX3B according to NF C 93-550, external diameter (10) There is no PO terminal on ATV71HC11Y…HC63Y drives. (11) Optional DC choke for ATV71H•••M3, ATV71HD11M3X…HD45M3X, ATV71•075N4…•D75N4 and ATV71P•••N4Z drives. Connected in place of the strap between the PO and PA/+ terminals. For ATV71HD55M3X, HD75M3X, ATV71HD90N4…HC50N4 drives, the choke is supplied with the drive; the customer is responsible for connecting it. (12) Software-configurable current (0…20 mA) or voltage (0…10 V) analog input. (13) Reference potentiometer. All terminals are located at the bottom of the drive. Fit interference suppressors on all inductive circuits near the drive or connected on the same circuit, such as relays, contactors, solenoid valves, fluorescent lighting, etc. Wiring Diagram Conforming to Standards EN 954-1 Category 3, IEC/EN 61508 Capacity SIL2, in Stopping Category 1 According to IEC/EN 60204-1

Three-Phase Power Supply, High Inertia Machine A1 ATV71 drive (5) Preventa XPS ATE safety module for monitoring emergency stops and switches. One safety module can manage the "Power Removal” safety function for several drives on the same machine. In this case the time delay must be adjusted on the drive controlling the motor that requires the longest stopping time. In addition, each drive must connect its PWR terminal to its + 24 V via the safety contacts on the XPS ATE module. These contacts are independent for each drive. F1 Fuse L1 DC choke Q1 Circuit-breaker S1 Emergency stop button with 2 N/C contacts S2 Run button (1) Power supply: 24 Vdc or Vac, 115 Vac, 230 Vac. (2) Requests controlled stopping of the movement and activates the “Power Removal” safety function. (3) Line choke (three-phase), mandatory for ATV71HC11Y…HC63Y drives (except when a special transformer is used (12-pulse)). (4) S2: resets XPS ATE module on power-up or after an emergency stop. ESC can be used to set external starting conditions. (5) For stopping times requiring more than 30 seconds in category 1, use a Preventa XPS AV safety module which can provide a maximum time delay of 300 seconds. (6) The logic output can be used to signal that the machine is in a safe state. (7) For ATV71HC40N4 drives combined with a 400 kW motor, ATV71HC50N4 and ATV71HC40Y…HC63Y, refer to the power terminal connections diagram. (8) Fault relay contacts. Used for remote signalling of the drive status. (9) Connection of the common for the logic inputs depends on the positioning of the SW1 switch. The above diagram shows the internal power supply switched to the “source” position (for other connection types, refer to the user guide). (10) Standardized coaxial cable, type RG174/U according to MIL-C17 or KX3B according to NF C 93-550, external diameter (11) Logic inputs LI1 and LI2 must be assigned to the direction of rotation: LI1 in the forward direction and LI2 in the reverse direction. (12) There is no PO terminal on ATV71HC11Y…HC63Y drives. (13) Optional DC choke for ATV71H•••M3, ATV71HD11M3X…HD45M3X, ATV71•075N4…•D75N4 and ATV71P•••N4Z drives. Connected in place of the strap between the PO and PA/+ terminals. For ATV71HD55M3X, HD75M3X, ATV71HD90N4…HC50N4 drives, the choke is supplied with the drive; the customer is responsible for connecting it. (14) Software-configurable current (0…20 mA) or voltage (0…10 V) analog input. (15) Reference potentiometer. All terminals are located at the bottom of the drive. Fit interference suppressors on all inductive circuits near the drive or connected on the same circuit, such as relays, contactors, solenoid valves, fluorescent lighting, etc.

The derating curves for the drive nominal current (In) depend on the temperature, the switching frequency and the mounting type. For intermediate temperatures (e.g. 55°C), interpolate between 2 curves. X Switching frequency (1) Mounting type Above 50ºC, the drive should be fitted with a control card fan kit.