ATV61HC63Y SCHNEIDER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 5

Technical content

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Aug 9, 2019 Product data sheet Characteristics ATV61HC63Y variable speed drive ATV61 - 630kW / 690V - 700HP / 575V - IP20 Product availability: Non-Stock - Not normally stocked in distribution facility Main Range of product Altivar 61 Product or component type Variable speed drive Product specific applica- tion Pumping and ventilation machine Component name ATV61 Motor power kW 500 kW 3 phasesat 500 V 630 kW 3 phases at 690 V Motor power hp 700 hp 3 phasesat 575 V Phase 3 phases Line current 613 Afor 600 V 3 phases 500 kW / 700 hp

616 Afor 690 V 3 phases 500 kW / 700 hp

673 Afor 500 V 3 phases 500 kW / 700 hp

EMC filter Level 3 EMC filter Assembly style With heat sink Maximum prospective line Isc 42 kA 3 phases Maximum transient cur- rent

888 Afor 60 s 3 phases

2.5 kHz Asynchronous motor control Voltage/Frequency ratio, 2 points Voltage/Frequency ratio, 5 points Flux vector control without sensor, standard Voltage/frequency ratio - Energy Saving, quadratic U/f Synchronous motor control profile Vector control without sensor, standard Communication port protocol CANopen Modbus Type of polarization No impedance Modbus Option card APOGEE FLN communication card BACnet communication card CC-Link communication card Controller inside programmable card DeviceNet communication card Ethernet/IP communication card Fipio communication card I/O extension card Interbus-S communication card LonWorks communication card METASYS N2 communication card Modbus Plus communication card Modbus TCP communication card Modbus/Uni-Telway communication card Multi-pump card Profibus DP communication card Profibus DP V1 communication card

Product destination Asynchronous motors Synchronous motors Power supply voltage limits 425...759 V Power supply frequency limits 47.5...63 Hz Continuous output current 672 Aat 2.5 kHz, 575 V 3 phases 675 A at 2.5 kHz, 690 V 3 phases 740 A at 2.5 kHz, 500 V 3 phases Output frequency 0.1...500 Hz Speed range 1...100 in open-loop mode, without speed feedback Speed accuracy +/- 10 % of nominal slip 0.2 Tn to Tn torque variation without speed feedback Torque accuracy +/- 15 % in open-loop mode, without speed feedback Transient overtorque 130 % of nominal motor torque, +/- 10 %for 60 s Braking torque 30 % without braking resistor <= 125 % with braking resistor Regulation loop Frequency PI regulator Motor slip compensation Adjustable Automatic whatever the load Can be suppressed Not available in voltage/frequency ratio (2 or 5 points) Diagnostic 1 LED red presence of drive voltage Output voltage <= power supply voltage Electrical isolation Between power and control terminals Type of cable for mounting in an enclosure With an IP21 or an IP31 kit: 3-strand IEC cableat 104 °F (40 °C), copper 70 °C PVC Without mounting kit: 1-strand IEC cableat 113 °F (45 °C), copper 70 °C PVC Without mounting kit: 1-strand IEC cableat 113 °F (45 °C), copper 90 °C XLPE/ EPR With UL Type 1 kit: 3-strand UL 508 cableat 104 °F (40 °C), copper 75 °C PVC mm² / AWG 14 PC/-, PO, PA/+ terminal 8 x 185 mm² / 5 x 500 kcmil 500 kcmil U/T1, V/T2, W/T3 terminal 6 x 185 mm² / 5 x 500 kcmil Tightening torque PC/-, PO, PA/+ 362.83 lbf.in (41 N.m) / 360 lb.in U/T1, V/T2, W/T3 362.83 lbf.in (41 N.m) / 360 lb.in N.m) Supply Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <= 10 mAfor overload and short-circuit protection Internal supply 24 V DC (21...27 V), <= 200 mAfor overload and short-circuit pro- tection External supply 24 V DC (19...30 V) Analogue input number 2 Analogue input type AI1-/Al1+ bipolar differential voltage +/- 10 V DC, input voltage 24 V max, resolu- tion 11 bits + sign AI2 software-configurable current 0...20 mA, impedance 242 Ohm, resolution 11 bits AI2 software-configurable voltage 0...10 V DC, input voltage 24 V max, im- pedance 30000 Ohm, resolution 11 bits Sampling time Discrete input LI6 (if configured as logic input) 2 ms, +/- 0.5 ms Analog input AI1-/Al1+ 2 ms, +/- 0.5 ms Analog input Al2 2 ms, +/- 0.5 ms Analog output AO1 2 ms, +/- 0.5 ms Discrete input LI1...LI5 2 ms, +/- 0.5 ms AI2 +/- 0.6 % for a temperature variation 60 °C AO1 +/- 1 % for a temperature variation 60 °C Linearity error AI1-/Al1+ +/- 0.15 % of maximum value AI2 +/- 0.15 % of maximum value AO1 +/- 0.2 % Analogue output number 1

Analogue output type AO1 software-configurable current, analogue output range 0...20 mA, impedance

500 Ohm, resolution 10 bits

AO1 software-configurable logic output 10 V, <= 20 mA AO1 software-configurable voltage, analogue output range 0...10 V DC, im- pedance 470 Ohm, resolution 10 bits Discrete output number 2 Discrete output type (R1A, R1B, R1C) configurable relay logic NO/NC, electrical durability 100000 cy- cles (R2A, R2B) configurable relay logic NO, electrical durability 100000 cycles Maximum response time <= 100 ms in STO (Safe Torque Off) R1A, R1B, R1C <= 7 ms, tolerance +/- 0.5 ms R2A, R2B <= 7 ms, tolerance +/- 0.5 ms Minimum switching current Configurable relay logic 3 mAat 24 V DC Maximum switching current R1, R2 on resistive load, 5 A at 30 V DC, cos phi = 1, 0 ms R1, R2 on inductive load, 2 A at 30 V DC, cos phi = 0.4, 7 ms R1, R2 on resistive load, 5 A at 250 V AC, cos phi = 1, 0 ms R1, R2 on inductive load, 2 A at 250 V AC, cos phi = 0.4, 7 ms Discrete input number 7 Discrete input type (LI1...LI5) programmable, 24 V DC, voltage limits <= 30 V, with level 1 PLC, im- pedance 3500 Ohm (LI6) switch-configurable, 24 V DC, voltage limits <= 30 V, with level 1 PLC, im- pedance 3500 Ohm (LI6) switch-configurable PTC probe, 0...6, impedance 1500 Ohm (PWR) safety input, 24 V DC, voltage limits <= 30 V, impedance 1500 Ohm Discrete input logic LI1...LI5 positive logic (source), < 5 V (state 0), > 11 V (state 1) LI1...LI5 negative logic (sink), > 16 V (state 0), < 10 V (state 1) LI6 (if configured as logic input) negative logic (sink), > 16 V (state 0), < 10 V (state 1) LI6 (if configured as logic input) positive logic (source), < 5 V (state 0), > 11 V (state 1) Acceleration and deceleration ramps Automatic adaptation of ramp if braking capacity exceeded, by using resistor Linear adjustable separately from 0.01 to 9000 s S, U or customized Braking to standstill By DC injection Protection type Drive against exceeding limit speed Drive against input phase loss Drive break on the control circuit Drive input phase breaks Drive line supply overvoltage Drive line supply undervoltage Drive overcurrent between output phases and earth Drive overheating protection Drive overvoltages on the DC bus Drive power removal Drive short-circuit between motor phases Drive thermal protection Motor motor phase break Motor power removal Motor thermal protection Insulation resistance > 1 mOhm at 500 V DC for 1 minute to earth Frequency resolution Analog input 0.024/50 Hz Display unit 0.1 Hz Connector type 1 RJ45 Modbus on front face

1 RJ45 Modbus on terminal

Male SUB-D 9 on RJ45 CANopen Physical interface 2-wire RS 485 Modbus Transmission frame RTU Modbus Transmission rate 20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps CANopen 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps Modbus on terminal 9600 bps, 19200 bps Modbus on front face Data format 8 bits, 1 stop, even parity Modbus on front face 8 bits, odd even or no configurable parity Modbus on terminal Number of addresses 1...247 Modbus 1...127 CANopen Method of access Slave CANopen Marking CE Operating position Vertical +/- 10 degree Product weight 844.37 lb(US) (383 kg) Width 44.09 in (1120 mm)

Height 54.72 in (1390 mm) Depth 14.84 in (377 mm) Environment Noise level 77 dB conforming to 86/188/EEC Dielectric strength 3110 V DC between earth and power terminals

5345 V DC between control and power terminals

Electromagnetic compatibility Conforming to IEC 61000-4-2 level 3 Conforming to IEC 61000-4-11 Conforming to IEC 61000-4-6 level 3 Conforming to IEC 61000-4-3 level 3 Conforming to IEC 61000-4-4 level 4 Standards EN 55011 class A group 2 EN 61800-3 environments 1 category C3 EN 61800-3 environments 2 category C3 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 60721-3-3 class 3C2 UL Type 1 Product certifications CSA C-Tick DNV GOST NOM 117 UL Pollution degree 3 conforming to EN/IEC 61800-5-1 3 conforming to UL 840 Degree of proctection IP00 conforming to EN/IEC 60529 IP00 conforming to EN/IEC 61800-5-1 IP30 on side parts conforming to EN/IEC 60529 IP30 on side parts conforming to EN/IEC 61800-5-1 IP30 on the front panel conforming to EN/IEC 60529 IP30 on the front panel conforming to EN/IEC 61800-5-1 IP41 on upper part conforming to EN/IEC 60529 IP41 on upper part conforming to EN/IEC 61800-5-1 Vibration resistance 1.5 mm peak to peak (f = 3...10 Hz) conforming to EN/IEC 60068-2-6 0.6 gn (f = 10...200 Hz) conforming to EN/IEC 60068-2-6 Shock resistance 4 gn 11 ms conforming to EN/IEC 60068-2-27 Relative humidity 5...95 % without condensation conforming to IEC 60068-2-3 5...95 % without dripping water conforming to IEC 60068-2-3 Operating altitude <= 3280.84 ft (1000 m) without derating Ordering and shipping details Category 22140 - ATV61 500 THRU 900 HP DRIVES Discount Schedule CP4C GTIN 003389119215114 Nbr. of units in pkg. 1 Package weight(Lbs) 1045 Returnability N Country of origin CN Offer Sustainability Sustainable offer status Green Premium product RoHS (date code: YYWW) Compliant - since 1601 - Schneider Electric declaration of conformity Schnei- der Electric declaration of conformity REACh Reference not containing SVHC above the threshold Product environmental profile Available End Of Life Information Product end of life instructions Need no specific recycling operations California proposition 65 WARNING: This product can expose you to chemicals including:

  • - - - - - - Substance 1 Lead and lead compounds, which is known to the State of California to cause can- cer and birth defects or other reproductive harm. - - - - - - - More information For more information go to www.p65warnings.ca.gov Contractual warranty Warranty period 18 months