variable speed drive ATV212 - 11kW - 15hp - 480V - 3ph - EMC class C2 - IP55 ATV212WD11N4 Product availability : Stock - Normally stocked in distribution facility Price* : 1,456.00 USD Main Device short name ATV212 Product destination Asynchronous motors Phase 3 phase Motor power kW 11 kW Maximum Horse Power Rating 15 hp Supply voltage limits 323…528 V Line current 16.9 A 480 V

21.2 A 380 V

Range of Product Altivar 212 Product or Component Type Variable speed drive Product specific application Pumps and fans in HVAC Communication Port Protocol BACnet METASYS N2 Modbus LonWorks APOGEE FLN EMC filter Class C2 EMC filter integrated IP degree of protection IP55 Complementary Apparent power 17.1 kVA 380 V Continuous output current 22.5 A 380 V

22.5 A 460 V

Maximum transient current 24.8 A 60 s Speed drive output frequency 0.5…200 Hz Speed range 1…10 Speed accuracy +/- 10 % of nominal slip 0.2 Tn to Tn Local signalling for DC bus energized 1 LED (red) Output voltage <= power supply voltage Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications * Price is “List Price” and may be subject to a trade discount – check with your local distributor or retailer for actual price. Apr 20, 2022

Isolation Electrical between power and control Type of cable Without mounting kit 1 IEC cable 113 °F (45 °C), copper 90 °C / XLPE/EPR Without mounting kit 1 IEC cable 113 °F (45 °C), copper 70 °C / PVC With UL Type 1 kit 3 UL 508 cable 104 °F (40 °C), copper 75 °C / PVC Electrical connection VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 0.00 in² (2.5 mm²) / AWG 14 L1/R, L2/S, L3/T terminal 0.02 in² (16 mm²) / AWG 4 Tightening torque 5.31 lbf.in (0.6 N.m) VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES) Supply Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection Internal supply 24 V DC 21…27 V), <200 A overload and short-circuit protection Sampling duration 2 ms +/- 0.5 ms F discrete 2 ms +/- 0.5 ms R discrete 2 ms +/- 0.5 ms RES discrete 3.5 ms +/- 0.5 ms VIA analog 22 ms +/- 0.5 ms VIB analog Response time FM 2 ms +/- 0.5 ms analog FLA, FLC 7 ms +/- 0.5 ms discrete FLB, FLC 7 ms +/- 0.5 ms discrete RY, RC 7 ms +/- 0.5 ms discrete Accuracy +/- 0.6 % VIA) for a temperature variation 60 °C +/- 0.6 % VIB) for a temperature variation 60 °C +/- 1 % FM) for a temperature variation 60 °C Linearity error VIA +/- 0.15 % of maximum value input VIB +/- 0.15 % of maximum value input FM +/- 0.2 % output Analogue output type FM switch-configurable voltage 0...10 V DC 7620 Ohm 10 bits FM switch-configurable current 0...20 mA 970 Ohm 10 bits Discrete output type Configurable relay logic FLA, FLC) NO - 100000 cycles Configurable relay logic FLB, FLC) NC - 100000 cycles Configurable relay logic RY, RC) NO - 100000 cycles Minimum switching current 3 mA 24 V DC configurable relay logic Maximum switching current 5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R)

5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R)

2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R) 2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R) Discrete input type F programmable 24 V DC level 1 PLC 4700 Ohm R programmable 24 V DC level 1 PLC 4700 Ohm RES programmable 24 V DC level 1 PLC 4700 Ohm Discrete input logic Positive logic (source) F, R, RES), <= 5 V, >= 11 V Negative logic (sink) F, R, RES), >= 16 V, <= 10 V Dielectric strength 3535 V DC between earth and power terminals

5092 V DC between control and power terminals

Insulation resistance >= 1 mOhm 500 V DC for 1 minute Frequency resolution Display unit 0.1 Hz Analog input 0.024/50 Hz Communication service Write multiple registers (16) 2 words maximum Read device identification (43) Time out setting from 0.1 to 100 s Write single register (06) Monitoring inhibitable Read holding registers (03) 2 words maximum Option card Communication card LonWorks Functionality Mid Specific application HVAC Discrete output number 2 Analogue input number 2 Analogue input type VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits VIB configurable PTC probe 0...6 probes 1500 Ohm VIA switch-configurable current 0...20 mA 250 Ohm 10 bits Analogue output number 1 Physical interface 2-wire RS 485 Apr 20, 2022

Transmission rate 9600 bps or 19200 bps Transmission frame RTU Number of addresses 1…247 Data format 8 bits, 1 stop, odd even or no configurable parity Type of polarization No impedance Asynchronous motor control profile Voltage/frequency ratio, 5 points Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) Voltage/frequency ratio - Energy Saving, quadratic U/f Flux vector control without sensor, standard Voltage/frequency ratio, 2 points Torque accuracy +/- 15 % Transient overtorque 120 % of nominal motor torque +/- 10 % 60 s Acceleration and deceleration ramps Linear adjustable separately from 0.01 to 3200 s Automatic based on the load Motor slip compensation Automatic whatever the load Adjustable Not available in voltage/frequency ratio motor control Switching frequency 6...16 kHz adjustable 12...16 kHz with derating factor Nominal switching frequency 12 kHz Braking to standstill By DC injection Network Frequency 47.5...63 Hz Prospective line Isc 22 kA Protection type Overheating protection drive Thermal power stage drive Short-circuit between motor phases drive Input phase breaks drive Overcurrent between output phases and earth drive Overvoltages on the DC bus drive Break on the control circuit drive Against exceeding limit speed drive Line supply overvoltage and undervoltage drive Line supply undervoltage drive Against input phase loss drive Thermal protection motor Motor phase break motor With PTC probes motor Width 11.42 in (290 mm) Height 22.05 in (560 mm) Depth 12.40 in (315 mm) Net Weight 66.80 lb(US) (30.3 kg) Environment Pollution degree 2 IEC 61800-5-1 IP degree of protection IP55 EN/IEC 61800-5-1 IP55 EN/IEC 60529 Vibration resistance 1.5 mm 3…13 Hz)EN/IEC 60068-2-6 1 gn 13…200 Hz)EN/IEC 60068-2-8 Shock resistance 15 gn 11 ms IEC 60068-2-27 Environmental characteristic Classes 3C1 IEC 60721-3-3 Classes 3S2 IEC 60721-3-3 Noise level 57.4 dB 86/188/EEC with current derating 1 % per 100 m <= 3280.84 ft (1000 m) without derating Relative humidity 5…95 % without condensation IEC 60068-2-3 Apr 20, 2022

5…95 % without dripping water IEC 60068-2-3 Ambient air temperature for operation 14…104 °F (-10…40 °C) without derating) 104…122 °F (40…50 °C) with derating factor) Operating position Vertical +/- 10 degree Product certifications C-tick UL NOM 117 CSA Marking CE Standards EN 61800-3 environments 1 category C3 IEC 61800-3 environments 1 category C2 IEC 61800-3 category C2 EN 61800-3 environments 2 category C1 IEC 61800-3 category C3 EN 61800-5-1 IEC 61800-3 environments 1 category C1 EN 61800-3 environments 1 category C1 IEC 61800-3 environments 2 category C2 IEC 61800-3 environments 1 category C3 IEC 61800-3 environments 2 category C3 EN 55011 class A group 1 IEC 61800-5-1 EN 61800-3 category C2 EN 61800-3 category C3 EN 61800-3 EN 61800-3 environments 1 category C2 EN 61800-3 environments 2 category C3 EN 61800-3 environments 2 category C2 IEC 61800-3 environments 2 category C1 IEC 61800-3 Assembly style With heat sink Electromagnetic compatibility Electrostatic discharge immunity test level 3 IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5 Conducted radio-frequency immunity test level 3 IEC 61000-4-6 Voltage dips and interruptions immunity test IEC 61000-4-11 Regulation loop Adjustable PI regulator Ambient Air Temperature for Storage Ordering and shipping details Category 22157-ATV212 1 - 25 HP 460 VOLT Discount Schedule CP4D GTIN 3606480322235 Nbr. of units in pkg. 1 Package weight(Lbs) 70.11 lb(US) (31.8 kg) Returnability No Country of origin FR Packing Units Unit Type of Package 1 PCE Package 1 Height 29.53 in (75 cm) Package 1 width 23.62 in (60 cm) Package 1 Length 31.50 in (80 cm) Unit Type of Package 2 P06 Number of Units in Package 2 1 Package 2 Weight 70.11 lb(US) (31.8 kg) Package 2 Height 29.53 in (75 cm) Package 2 width 23.62 in (60 cm) Apr 20, 2022

Package 2 Length 31.50 in (80 cm) Offer Sustainability Sustainable offer status Green Premium product California proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov REACh Regulation REACh Declaration EU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration Mercury free Yes RoHS exemption information Yes China RoHS Regulation China RoHS declaration Environmental Disclosure Product Environmental Profile Circularity Profile End of Life Information WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. Contractual warranty Warranty 18 months Apr 20, 2022

ATV212W a b c G H K ø D11N4, D15N4 D11N4C, D15N4C 290 560 315 250 544 8 6 D18N4 D18N4C 310 665 315 270 650 10 6 D22N4, D30N4 D22N4C, D30N4C 284 720 315 245 700 10 7 D37N4, D45N4 D37N4C, D45N4C 284 880 343 245 860 10 7 D55N4, D75N4 D55N4C, D75N4C 362 1000 364 300 975 10 9 Dimensions in in. ATV212W a b c G H K ø D11N4, D15N4 D11N4C, D15N4C D18N4 D18N4C D22N4, D30N4 D22N4C, D30N4C D37N4, D45N4 D37N4C, D45N4C D55N4, D75N4 D55N4C, D75N4C Apr 20, 2022

Depending on the conditions in which the drive is to be used, its installation will require certain precautions and the use of appropriate accessories. Install the unit vertically:

  • Do not place it close to heating elements.
  • Leave sufficient free space to ensure that the air required for cooling purposes can circulate from bottom to the top of the unit. Type A Mounting Apr 20, 2022

Recommended Wiring Diagram 3-Phase Power Supply A1: ATV 212 drive KM1: Contactor Q1: Circuit breaker Q2: GV2 L rated at twice the nominal primary current of T1 Q3: GB2CB05 S1, S2: XB4 B or XB5 A pushbuttons T1: 100 VA transformer 220 V secondary (1) Fault relay contacts for remote signalling of the drive status (2) Connection of the common for the logic inputs depends on the positioning of the switch (Source, PLC, Sink) (3) Reference potentiometer SZ1RV1202 NOTE: All terminals are located at the bottom of the drive. Install interference suppressors on all inductive circuits near the drive or connected on the same circuit, such as relays, contactors, solenoid valves, fluorescent lighting, etc. Switches (Factory Settings) Voltage/current selection for analog I/O (VIA and VIB) Voltage/current selection for analog I/O (FM) Selection of logic type (1) negative logic (2) positive logic Apr 20, 2022

Other Possible Wiring Diagrams Logic Inputs According to the Position of the Logic Type Switch “Source” position “Sink” position “PLC” position with PLC transistor outputs (1) PLC (1) PLC 2-wire control F: Forward R: Preset speed (2) ATV 212 control terminals 3-wire control F: Forward R: Stop RES: Reverse (2) ATV 212 control terminals PTC probe (2) ATV 212 control terminals (3) Motor Analog Inputs Voltage analog inputs External +10 V (2) ATV 212 control terminals (4) Speed reference potentiometer 2.2 to 10 kΩ (2) ATV 212 control terminals Analog input configured for current: 0-20 mA, 4-20 mA, X-Y mA (2) ATV 212 control terminals (5) Source 0-20 mA, 4-20 mA, X-Y mA Apr 20, 2022

Analog input VIA configured as positive logic input (“Source” position) (2) ATV 212 control terminals Analog input VIA configured as negative logic input (“Sink” position) (2) ATV 212 control terminals Apr 20, 2022

The derating curves for the drive nominal current (In) depend on the temperature and the switching frequency. For intermediate temperatures (45°C for example), interpolate between 2 curves. X Switching frequency Apr 20, 2022