ATV212HU30M3X SCHNEIDER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 12

Technical content

variable speed drive ATV212 - 3kW - 240V - 3ph - wo EMC - IP21 ATV212HU30M3X Discontinued on: 14 February 2023 Main Device short name ATV212 Product destination Asynchronous motors Network number of phases 3 phases Motor power kW 3 kW Motor power hp 4 hp Supply voltage limits 170…264 V Line current 10 A at 240 V

11.9 A at 200 V

Range of product Altivar 212 Product or component type Variable speed drive Product specific application Pumps and fans in HVAC Communication port protocol Modbus LonWorks METASYS N2 BACnet APOGEE FLN EMC filter Without EMC filter IP degree of protection IP21 Complementary Apparent power 5.2 kVA at 240 V Continuous output current 13.7 A at 230 V Maximum transient current 15.1 A for 60 s Speed drive output frequency 0.5…200 Hz Speed range 1…10 Speed accuracy +/- 10 % of nominal slip 0.2 Tn to Tn Local signalling 1 LED (red) for DC bus energized Output voltage <= power supply voltage Isolation Electrical between power and control Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications Feb 20, 2023

Type of cable Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 90 °C / XLPE/EPR Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 70 °C / PVC With UL Type 1 kit: 3 wire(s)UL 508 cable at 40 °C, copper 75 °C / PVC Electrical connection VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES: terminal 2.5 mm² / AWG 14 L1/R, L2/S, L3/T: terminal 6 mm² / AWG 10 Tightening torque 1.3 N.m, 11.5 lb.in (L1/R, L2/S, L3/T) 0.6 N.m (VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES) Supply Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 A, protection type: overload and short-circuit protection Internal supply: 24 V DC (21…27 V), <200 A, protection type: overload and short-circuit protection Sampling duration 2 ms +/- 0.5 ms F discrete 2 ms +/- 0.5 ms R discrete 2 ms +/- 0.5 ms RES discrete 3.5 ms +/- 0.5 ms VIA analog 22 ms +/- 0.5 ms VIB analog Response time FM 2 ms, tolerance +/- 0.5 ms for analog output(s) FLA, FLC 7 ms, tolerance +/- 0.5 ms for discrete output(s) FLB, FLC 7 ms, tolerance +/- 0.5 ms for discrete output(s) RY, RC 7 ms, tolerance +/- 0.5 ms for discrete output(s) Accuracy +/- 0.6 % (VIA) for a temperature variation 60 °C +/- 0.6 % (VIB) for a temperature variation 60 °C +/- 1 % (FM) for a temperature variation 60 °C Linearity error VIA: +/- 0.15 % of maximum value for input VIB: +/- 0.15 % of maximum value for input FM: +/- 0.2 % for output Analogue output type FM switch-configurable voltage 0...10 V DC, impedance: 7620 Ohm, resolution 10 bits FM switch-configurable current 0...20 mA, impedance: 970 Ohm, resolution 10 bits Discrete output type Configurable relay logic: (FLA, FLC) NO - 100000 cycles Configurable relay logic: (FLB, FLC) NC - 100000 cycles Configurable relay logic: (RY, RC) NO - 100000 cycles Minimum switching current 3 mA at 24 V DC for configurable relay logic Maximum switching current 5 A at 250 V AC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R)

5 A at 30 V DC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R)

2 A at 250 V AC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R) 2 A at 30 V DC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R) Discrete input type F programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm R programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm RES programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm Discrete input logic Positive logic (source) (F, R, RES), <= 5 V (state 0), >= 11 V (state 1) Negative logic (sink) (F, R, RES), >= 16 V (state 0), <= 10 V (state 1) Dielectric strength 2830 V DC between earth and power terminals

4230 V DC between control and power terminals

Insulation resistance >= 1 mOhm 500 V DC for 1 minute Frequency resolution Display unit: 0.1 Hz Analog input: 0.024/50 Hz Communication service Time out setting from 0.1 to 100 s Read device identification (43) Monitoring inhibitable Read holding registers (03) 2 words maximum Write single register (06) Write multiple registers (16) 2 words maximum Option card Communication card for LonWorks Power dissipation in W 146 W Air flow 50 m3/h Specific application HVAC Variable speed drive application selection Compressor for scroll Building - HVAC Fan Building - HVAC Pump Building - HVAC Motor power range AC-3 2.2…3 kW at 200…240 V 3 phases Motor starter type Variable speed drive Discrete output number 2 Analogue input number 2 Analogue input type VIA switch-configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bits Feb 20, 2023

VIB configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bits VIB configurable PTC probe: 0...6 probes, impedance: 1500 Ohm VIA switch-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 10 bits Analogue output number 1 Physical interface 2-wire RS 485 Connector type 1 RJ45 1 open style Transmission rate 9600 bps or 19200 bps Transmission frame RTU Number of addresses 1…247 Data format 8 bits, 1 stop, odd even or no configurable parity Type of polarization No impedance Asynchronous motor control profile Voltage/frequency ratio, 5 points Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) Voltage/frequency ratio, 2 points Flux vector control without sensor, standard Voltage/frequency ratio - Energy Saving, quadratic U/f Torque accuracy +/- 15 % Transient overtorque 120 % of nominal motor torque +/- 10 % for 60 s Acceleration and deceleration ramps Automatic based on the load Linear adjustable separately from 0.01 to 3200 s Motor slip compensation Not available in voltage/frequency ratio motor control Automatic whatever the load Adjustable Switching frequency 6...16 kHz adjustable 12...16 kHz with derating factor Nominal switching frequency 12 kHz Braking to standstill By DC injection Network frequency 47.5...63 Hz Prospective line Isc 5 kA Protection type Overheating protection: drive Thermal power stage: drive Short-circuit between motor phases: drive Input phase breaks: drive Overcurrent between output phases and earth: drive Overvoltages on the DC bus: drive Break on the control circuit: drive Against exceeding limit speed: drive Line supply overvoltage and undervoltage: drive Line supply undervoltage: drive Against input phase loss: drive Thermal protection: motor Motor phase break: motor With PTC probes: motor Width 142 mm Height 184 mm Depth 150 mm Net weight 3.05 kg Environment Pollution degree 3 conforming to IEC 61800-5-1 IP20 on upper part without blanking plate on cover conforming to EN/IEC 61800-5-1 IP20 on upper part without blanking plate on cover conforming to EN/IEC 60529 IP21 conforming to EN/IEC 61800-5-1 IP21 conforming to EN/IEC 60529 IP41 on upper part conforming to EN/IEC 61800-5-1 IP41 on upper part conforming to EN/IEC 60529 Vibration resistance 1.5 mm (f= 3…13 Hz) conforming to EN/IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-8 Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27 Feb 20, 2023

Environmental characteristic Classes 3C1 conforming to IEC 60721-3-3 Classes 3S2 conforming to IEC 60721-3-3 Noise level 51 dB conforming to 86/188/EEC Operating altitude 1000...3000 m limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m <= 1000 m without derating Relative humidity 5…95 % without condensation conforming to IEC 60068-2-3 5…95 % without dripping water conforming to IEC 60068-2-3 Ambient air temperature for operation -10…40 °C (without derating) 40…50 °C (with derating factor) Operating position Vertical +/- 10 degree Product certifications NOM 117 C-Tick UL CSA Marking CE Standards IEC 61800-3 environments 1 category C2 EN 61800-3 environments 1 category C3 IEC 61800-3 environments 2 category C1 EN 61800-3 environments 2 category C3 EN 61800-3 environments 2 category C2 IEC 61800-3 environments 2 category C2 EN 61800-3 IEC 61800-3 environments 1 category C3 IEC 61800-3 EN 61800-5-1 EN 61800-3 environments 1 category C1 IEC 61800-3 environments 2 category C3 IEC 61800-5-1 IEC 61800-3 environments 1 category C1 UL Type 1 EN 61800-3 environments 1 category C2 EN 61800-3 environments 2 category C1 Assembly style With heat sink Electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11 Regulation loop Adjustable PI regulator Ambient air temperature for storage -25…70 °C Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 24 cm Package 1 Width 24.5 cm Package 1 Length 24.5 cm Package 1 Weight 2.797 kg Unit Type of Package 2 P06 Number of Units in Package 2 12 Package 2 Height 75 cm Package 2 Width 60 cm Package 2 Length 80 cm Package 2 Weight 46.564 kg Offer Sustainability Sustainable offer status Green Premium product Feb 20, 2023

REACh Regulation REACh Declaration EU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration Mercury free Yes China RoHS Regulation China RoHS declaration RoHS exemption information Yes Environmental Disclosure Product Environmental Profile Circularity Profile End of Life Information WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins California proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov Contractual warranty Warranty 18 months Feb 20, 2023

ATV212H a b G H J K Ø 075M3X...U22M3X 075N4...U22N4 107 143 93 121.5 5 16.5 2 x Ø5 U30M3X, U40M3X U30N4...U55N4 142 184 126 157 6.5 20.5 4 x Ø5 Dimensions in in. ATV212H a b G H J K Ø 075M3X...U22M3X 075N4...U22N4 U30M3X, U40M3X U30N4...U55N4 Plate for EMC mounting (supplied with the drive) (1) 2 x M5 screws Dimensions in mm ATV212H b1 c 075M3X...U22M3X 075N4...U22N4 49 67.3 U30M3X, U40M3X U30N4...U55N4 48 88.8 Dimensions in in. ATV212H b1 c 075M3X...U22M3X 075N4...U22N4 1.93 2.65 U30M3X, U40M3X U30N4...U55N4 1.89 3.50 Feb 20, 2023

Depending on the conditions in which the drive is to be used, its installation will require certain precautions and the use of appropriate accessories. Install the unit vertically:

  • Do not place it close to heating elements.
  • Leave sufficient free space to ensure that the air required for cooling purposes can circulate from bottom to the top of the unit. Mounting Types Type A mounting Type B mounting Type C mounting By removing the protective blanking cover from the top of the drive, the degree of protection for the drive becomes IP21. The protective blanking cover may vary according to the drive model, see opposite. Feb 20, 2023

Specific Recommendations for Mounting in an Enclosure To help ensure proper air circulation in the drive:

  • Fit ventilation grilles.
  • Check that there is sufficient ventilation. If there is not, install a forced ventilation unit with a filter. The openings and/or fans must provide a flow rate at least equal to that of the drive fans (refer to the product characteristics).
  • Use special filters with UL Type 12/IP54 protection.
  • Remove the blanking cover from the top of the drive. Sealed Metal Enclosure (IP54 Degree of Protection) The drive must be mounted in a dust and damp proof enclosure in certain environmental conditions, such as dust, corrosive gases, high humidity with risk of condensation and dripping water, splashing liquid, etc.This enables the drive to be used in an enclosure where the maximum internal temperature reaches 50°C. Feb 20, 2023

Recommended Wiring Diagram 3-Phase Power Supply A1: ATV 212 drive KM1: Contactor Q1: Circuit breaker Q2: GV2 L rated at twice the nominal primary current of T1 Q3: GB2CB05 S1, S2: XB4 B or XB5 A pushbuttons T1: 100 VA transformer 220 V secondary (1) Fault relay contacts for remote signalling of the drive status (2) Connection of the common for the logic inputs depends on the positioning of the switch (Source, PLC, Sink) (3) Reference potentiometer SZ1RV1202 NOTE: All terminals are located at the bottom of the drive. Install interference suppressors on all inductive circuits near the drive or connected on the same circuit, such as relays, contactors, solenoid valves, fluorescent lighting, etc. Switches (Factory Settings) Voltage/current selection for analog I/O (VIA and VIB) Voltage/current selection for analog I/O (FM) Selection of logic type (1) negative logic (2) positive logic Feb 20, 2023

Other Possible Wiring Diagrams Logic Inputs According to the Position of the Logic Type Switch “Source” position “Sink” position “PLC” position with PLC transistor outputs (1) PLC (1) PLC 2-wire control F: Forward R: Preset speed (2) ATV 212 control terminals 3-wire control F: Forward R: Stop RES: Reverse (2) ATV 212 control terminals PTC probe (2) ATV 212 control terminals (3) Motor Analog Inputs Voltage analog inputs External +10 V (2) ATV 212 control terminals (4) Speed reference potentiometer 2.2 to 10 kΩ (2) ATV 212 control terminals Analog input configured for current: 0-20 mA, 4-20 mA, X-Y mA (2) ATV 212 control terminals (5) Source 0-20 mA, 4-20 mA, X-Y mA Feb 20, 2023

Analog input VIA configured as positive logic input (“Source” position) (2) ATV 212 control terminals Analog input VIA configured as negative logic input (“Sink” position) (2) ATV 212 control terminals Feb 20, 2023

The derating curves for the drive nominal current (In) depend on the temperature, the switching frequency and the mounting type (A, B or C). For intermediate temperatures (45°C for example), interpolate between 2 curves. X Switching frequency Recommended replacement(s) ATV212HU30M3X is replaced by the following product range: Altivar Machine ATV320 Smart variable speed drive from 0.18 to 15kW (0.25 to 20Hp) Products: 285 Feb 20, 2023