ATV212HU22N4 SCHNEIDER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 15

Technical content

variable speed drive, Altivar 212, 2.2kW, 3hp, 480V, 3 phases, with EMC, IP21 ATV212HU22N4 Product availability: Stock - Normally stocked in distribution facility Price*: 726.00 USD Main Device Short Name ATV212 Product Destination Asynchronous motors Phase 3 phase Motor Power Kw 2.2 kW Maximum Horse Power Rating 3 hp Supply Voltage Limits 323…528 V Line Current 3.6 A 480 V

4.6 A 380 V

Range Of Product Altivar 212 Product Or Component Type Variable speed drive Product Specific Application Pumps and fans in HVAC Communication Port Protocol BACnet LonWorks Modbus METASYS N2 APOGEE FLN Emc Filter Class C2 EMC filter integrated Ip Degree Of Protection IP21 Complementary Apparent Power 3.9 kVA 380 V Continuous Output Current 5.1 A 380 V

5.1 A 460 V

Maximum Transient Current 5.6 A 60 s Speed Drive Output Frequency 0.5…200 Hz Speed Range 1…10 Speed Accuracy +/- 10 % of nominal slip 0.2 Tn to Tn Local Signalling for DC bus energized 1 LED (red) Output Voltage <= power supply voltage Isolation Electrical between power and control Product data sheet Specifications May 27, 2024 Price is “List Price” and may be subject to a trade discount – check with your local distributor or retailer for actual price. Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications

Type Of Cable Without mounting kit 1 IEC cable 113 °F (45 °C), copper 90 °C / XLPE/EPR Without mounting kit 1 IEC cable 113 °F (45 °C), copper 70 °C / PVC With UL Type 1 kit 3 UL 508 cable 104 °F (40 °C), copper 75 °C / PVC Electrical Connection VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 0.00 in² (2.5 mm²) / AWG L1/R, L2/S, L3/T terminal 0.01 in² (6 mm²) / AWG 10 5.31 lbf.in (0.6 N.m) VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES) Supply Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection Internal supply 24 V DC 21…27 V), <200 A overload and short-circuit protection Sampling Duration 2 ms +/- 0.5 ms F discrete 2 ms +/- 0.5 ms R discrete 2 ms +/- 0.5 ms RES discrete 3.5 ms +/- 0.5 ms VIA analog 22 ms +/- 0.5 ms VIB analog Response Time FM 2 ms +/- 0.5 ms analog FLA, FLC 7 ms +/- 0.5 ms discrete FLB, FLC 7 ms +/- 0.5 ms discrete RY, RC 7 ms +/- 0.5 ms discrete Accuracy +/- 0.6 % VIA) for a temperature variation 60 °C +/- 0.6 % VIB) for a temperature variation 60 °C +/- 1 % FM) for a temperature variation 60 °C Linearity Error VIA +/- 0.15 % of maximum value input VIB +/- 0.15 % of maximum value input FM +/- 0.2 % output Analogue Output Type FM switch-configurable voltage 0...10 V DC 7620 Ohm 10 bits FM switch-configurable current 0...20 mA 970 Ohm 10 bits Discrete Output Type Configurable relay logic FLA, FLC) NO - 100000 cycles Configurable relay logic FLB, FLC) NC - 100000 cycles Configurable relay logic RY, RC) NO - 100000 cycles Minimum Switching Current 3 mA 24 V DC configurable relay logic Maximum Switching Current 5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R)

5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R)

2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R) 2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R) Discrete Input Type F programmable 24 V DC level 1 PLC 4700 Ohm R programmable 24 V DC level 1 PLC 4700 Ohm RES programmable 24 V DC level 1 PLC 4700 Ohm Discrete Input Logic Positive logic (source) F, R, RES), <= 5 V, >= 11 V Negative logic (sink) F, R, RES), >= 16 V, <= 10 V Dielectric Strength 3535 V DC between earth and power terminals

5092 V DC between control and power terminals

Insulation Resistance >= 1 mOhm 500 V DC for 1 minute Frequency Resolution Display unit 0.1 Hz Analog input 0.024/50 Hz Communication Service Write single register (06) Read device identification (43) Time out setting from 0.1 to 100 s Read holding registers (03) 2 words maximum Write multiple registers (16) 2 words maximum Monitoring inhibitable Option Card Communication card LonWorks Power Dissipation In W 103 W Air Flow 9246.19 Gal/hr(US) (35 m3/h) Functionality Mid Specific Application HVAC May 27, 2024

Variable Speed Drive Application Selection Building - HVAC compressor for scroll Building - HVAC fan Building - HVAC pump Motor Power Range Ac-3 2.2…3 kW 380…440 V 3 phase 2.2…3 kW 480…500 V 3 phase Motor Starter Type Variable speed drive Discrete Output Number 2 Analogue Input Number 2 Analogue Input Type VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits VIB configurable PTC probe 0...6 probes 1500 Ohm VIA switch-configurable current 0...20 mA 250 Ohm 10 bits Analogue Output Number 1 Physical Interface 2-wire RS 485 Connector Type 1 open style

1 RJ45

Transmission Rate 9600 bps or 19200 bps Transmission Frame RTU Number Of Addresses 1…247 Data Format 8 bits, 1 stop, odd even or no configurable parity Type Of Polarization No impedance Asynchronous Motor Control Profile Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) Voltage/frequency ratio, 5 points Flux vector control without sensor, standard Voltage/frequency ratio - Energy Saving, quadratic U/f Voltage/frequency ratio, 2 points Torque Accuracy +/- 15 % Transient Overtorque 120 % of nominal motor torque +/- 10 % 60 s Acceleration And Deceleration Ramps Automatic based on the load Linear adjustable separately from 0.01 to 3200 s Motor Slip Compensation Not available in voltage/frequency ratio motor control Adjustable Automatic whatever the load Switching Frequency 6...16 kHz adjustable 12...16 kHz with derating factor Nominal Switching Frequency 12 kHz Braking To Standstill By DC injection Network Frequency 47.5...63 Hz Prospective Line Isc 5 kA Protection Type Overheating protection drive Thermal power stage drive Short-circuit between motor phases drive Input phase breaks drive Overcurrent between output phases and earth drive Overvoltages on the DC bus drive Break on the control circuit drive Against exceeding limit speed drive Line supply overvoltage and undervoltage drive Line supply undervoltage drive Against input phase loss drive Thermal protection motor Motor phase break motor With PTC probes motor Width 4.21 in (107 mm) May 27, 2024

Height 5.63 in (143 mm) Depth 5.91 in (150 mm) Net Weight 4.41 lb(US) (2 kg) Environment Pollution Degree 3 IEC 61800-5-1 Ip Degree Of Protection IP20 on upper part without blanking plate on cover IEC 61800-5-1 IP20 on upper part without blanking plate on cover IEC 60529 IP21 IEC 61800-5-1 IP21 IEC 60529 IP41 on upper part IEC 61800-5-1 IP41 on upper part IEC 60529 Vibration Resistance 1.5 mm 3…13 Hz)IEC 60068-2-6 1 gn 13…200 Hz)EN/IEC 60068-2-8 Shock Resistance 15 gn 11 ms IEC 60068-2-27 Environmental Characteristic Classes 3C1 IEC 60721-3-3 Classes 3S2 IEC 60721-3-3 Noise Level 51 dB 86/188/EEC distribution network with current derating 1 % per 100 m <= 3280.84 ft (1000 m) without derating Relative Humidity 5…95 % without condensation IEC 60068-2-3 5…95 % without dripping water IEC 60068-2-3 Ambient Air Temperature For Operation 14…104 °F (-10…40 °C) without derating) 104…122 °F (40…50 °C) with derating factor) Operating Position Vertical +/- 10 degree Product Certifications CSA NOM 117 UL C-tick Marking CE Standards IEC 61800-3 IEC 61800-5-1 IEC 61800-3 environments 1 category C2 IEC 61800-3 environments 1 category C2 IEC 61800-3 IEC 61800-3 environments 2 category C3 IEC 61800-3 environments 1 category C1 IEC 61800-3 environments 1 category C3 IEC 61800-3 category C3 IEC 61800-3 environments 2 category C1 UL Type 1 EN 61800-3 category C3 IEC 61800-3 environments 1 category C3 IEC 61800-3 category C2 IEC 61800-3 environments 2 category C2 IEC 61800-3 environments 2 category C3 EN 55011 class A group 1 IEC 61800-3 environments 2 category C2 IEC 61800-3 environments 2 category C1 IEC 61800-5-1 IEC 61800-3 category C2 IEC 61800-3 environments 1 category C1 Assembly Style With heat sink Electromagnetic Compatibility Electrostatic discharge immunity test level 3 IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5 Conducted radio-frequency immunity test level 3 IEC 61000-4-6 Voltage dips and interruptions immunity test IEC 61000-4-11 Regulation Loop Adjustable PI regulator May 27, 2024

Ambient Air Temperature For Storage Ordering and shipping details Category US1CP4D22157 Discount Schedule CP4D Gtin 3606480322464 Returnability Yes Country Of Origin FR Packing Units Unit Type Of Package 1 PCE Number Of Units In Package 1 1 Package 1 Height 7.09 in (18.000 cm) Package 1 Width 7.28 in (18.500 cm) Package 1 Length 8.35 in (21.200 cm) Package 1 Weight 4.30 lb(US) (1.950 kg) Unit Type Of Package 2 P06 Number Of Units In Package 2 27 Package 2 Height 29.53 in (75.000 cm) Package 2 Width 23.62 in (60.000 cm) Package 2 Length 31.50 in (80.000 cm) Package 2 Weight 145.57 lb(US) (66.028 kg) Contractual warranty Warranty 18 months May 27, 2024

Green PremiumTM label is Schneider Electric’s commitment to delivering products with best-in- class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products. Guide to assessing product sustainability is a white paper that clarifies global eco-label standards and how to interpret environmental declarations. Well-being performance Mercury Free Rohs Exemption Information Yes Reach Regulation REACh Declaration Eu Rohs Directive Pro-active compliance (Product out of EU RoHS legal scope) China Rohs Regulation China RoHS declaration Weee The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. California Proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov Learn more about Green Premium  Guide to assess a product’s sustainability  May 27, 2024

ATV212H a b G H J K Ø 075M3X...U22M3X U30M3X, U40M3X Dimensions in in. ATV212H a b G H J K Ø 075M3X...U22M3X U30M3X, U40M3X Plate for EMC mounting (supplied with the drive) (1) 2 x M5 screws Dimensions in mm ATV212H b1 c 075M3X...U22M3X 075N4...U22N4 49 67.3 U30M3X, U40M3X U30N4...U55N4 48 88.8 Dimensions in in. ATV212H b1 c 075M3X...U22M3X Product data sheet ATV212HU22N4 May 27, 2024

U30M3X, U40M3X Product data sheet ATV212HU22N4 May 27, 2024

Depending on the conditions in which the drive is to be used, its installation will require certain precautions and the use of appropriate accessories. Install the unit vertically: Do not place it close to heating elements. Leave sufficient free space to ensure that the air required for cooling purposes can circulate from bottom to the top of the unit. Mounting Types Type A mounting Type B mounting Type C mounting By removing the protective blanking cover from the top of the drive, the degree of protection for the drive becomes IP21. The protective blanking cover may vary according to the drive model, see opposite. Product data sheet ATV212HU22N4 May 27, 2024

Specific Recommendations for Mounting in an Enclosure To help ensure proper air circulation in the drive: Fit ventilation grilles. Check that there is sufficient ventilation. If there is not, install a forced ventilation unit with a filter. The openings and/or fans must provide a flow rate at least equal to that of the drive fans (refer to the product characteristics). Use special filters with UL Type 12/IP54 protection. Remove the blanking cover from the top of the drive. Sealed Metal Enclosure (IP54 Degree of Protection) The drive must be mounted in a dust and damp proof enclosure in certain environmental conditions, such as dust, corrosive gases, high humidity with risk of condensation and dripping water, splashing liquid, etc.This enables the drive to be used in an enclosure where the maximum internal temperature reaches 50°C. Product data sheet ATV212HU22N4 May 27, 2024

Recommended Wiring Diagram 3-Phase Power Supply A1: ATV 212 drive KM1: Contactor Q1: Circuit breaker Q2: GV2 L rated at twice the nominal primary current of T1 Q3: GB2CB05 S1, S2: XB4 B or XB5 A pushbuttons T1: 100 VA transformer 220 V secondary (1) Fault relay contacts for remote signalling of the drive status (2) Connection of the common for the logic inputs depends on the positioning of the switch (Source, PLC, Sink) (3) Reference potentiometer SZ1RV1202 NOTE: All terminals are located at the bottom of the drive. Install interference suppressors on all inductive circuits near the drive or connected on the same circuit, such as relays, contactors, solenoid valves, fluorescent lighting, etc. Switches (Factory Settings) Voltage/current selection for analog I/O (VIA and VIB) Voltage/current selection for analog I/O (FM) Product data sheet ATV212HU22N4 May 27, 2024

(1) negative logic (2) positive logic Product data sheet ATV212HU22N4 May 27, 2024

Other Possible Wiring Diagrams Logic Inputs According to the Position of the Logic Type Switch “Source” position “Sink” position “PLC” position with PLC transistor outputs (1) PLC (1) PLC 2-wire control F: Forward R: Preset speed (2) ATV 212 control terminals 3-wire control F: Forward R: Stop RES: Reverse (2) ATV 212 control terminals PTC probe Product data sheet ATV212HU22N4 May 27, 2024

(2) ATV 212 control terminals (3) Motor Analog Inputs Voltage analog inputs External +10 V (2) ATV 212 control terminals (4) Speed reference potentiometer 2.2 to 10 kΩ (2) ATV 212 control terminals Analog input configured for current: 0-20 mA, 4-20 mA, X-Y mA (2) ATV 212 control terminals (5) Source 0-20 mA, 4-20 mA, X-Y mA Analog input VIA configured as positive logic input (“Source” position) (2) ATV 212 control terminals Analog input VIA configured as negative logic input (“Sink” position) (2) ATV 212 control terminals Product data sheet ATV212HU22N4 May 27, 2024

The derating curves for the drive nominal current (In) depend on the temperature, the switching frequency and the mounting type (A, B or C). For intermediate temperatures (45°C for example), interpolate between 2 curves. X Switching frequency Product data sheet ATV212HU22N4 May 27, 2024