S37K5N-A ABB | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 20
Technical content
Datasheet sections
- 3 Enclosed Switching Products 0115 ABB Low Voltage
Enclosed switch disconnectors, switch fuses and transfer switches Short form catalogue
3 Enclosed Switching Products 0115 ABB Low Voltage
4 Enclosed Switching Products 0115 ABB Low Voltage 5 Enclosed Switching Products 0115 ABB Low Voltage
Load Break Switches 3 - 4 - 6 pole 16...125 amps
Description
- IP65 rated
- Grey plastic enclosure
- Standard handle - Red/Yellow (padlockable in the off position)
- Cable entries top and bottom
- All OTP16 (excluding 3p) /25/32 all have 25/20mm reducers Rating@415v Dimensions mm Part Number Product Hierarchy 4000002 Order Code1th A AC22 AC23 kW No. Poles H W D 25 16 16 7.5 3 + solid neutral 150 130 60 OTP16BA3M OTP16BA3M
4 OTP16BA4MS OTP16BA4MS
6 OTP16BA6M OTP16BA6M
4 OTP25BA4M OTP25BA4M
6 OTP25BA6M OTP25BA6M
4 OTP32BA4M OTP32BA4M
6 OTP32BA6M OTP32BA6M
4 OTP45BA4M OTP45BA4M
6 OTP45BA6M OTP45BA6M
4 OTP63BA4M OTP63BA4M
6 OTP63BA6M OTP63BA6M
4 OTP125BA4U OTP125BA4U
6 OTP125BA6U OTP125BA6U
Polycarbonate Enclosure 9kW ... 37kW 4 pole 32 25 9 125 100 107 S47K5N-A S47K5N-A 40 40 11 S415KN-A S415KN-A 63 63 22 170 140 108 S418KN-A S418KN-A 80 80 37 S426KN-A S426KN-A Safety Switches 3 pole 16...40 amps Rating@415v Dimensions mm Part Number Product Hierarchy 4000002 Order Code1th A AC22 AC23 kW No. Poles H W D 25 16 16 7.5 3 150 130 60 OTP16B3M OTP16B3M 32 25 20 9 3 150 130 60 OTP16B3M OTP16B3M 40 40 23 11 3 150 130 60 OTP32B3U OTP32B3U Switchgear - Loadbreak & safety switches IP65 Double insulated enclosure Polycarbonate Enclosure 9kW ... 11kW 3 pole Rating@415v Dimensions mm Part Number Product Hierarchy 4000002 Order Code1th A AC22 kW H W D 32 25 9 125 100 107 S37K5N-A S37K5N-A 40 40 11 S315KN-A S315KN-A Load Break Switches 3 - 4 pole 9...37kW
- IP65 three and four-pole switch disconnectors suitable for load break switching or isolation.
- Polycarbonate enclosure. IEC 60947-3
5 Enclosed Switching Products 0115 ABB Low Voltage
Load Break Switches 3 - 4 pole 20 ... 800A
- IP65 rated (not suitable for external installation)
- Powder coated textured finish (RAL 7035)
- All 3 pole switches include detachable neutral link (OT160 solid link)
- Hinged lid complete with lock
- Padlockable pistol grip handle as standard
- Removable gland plates fitted top and bottom (see below for knockout configurations)
- Spreader boxes available see below Rating@415v [A] Dimensions Part Number Product Hierarchy 4000003 Order Code1th A AC22 AC23 H W D No. Poles 32 25 20 300 200 150 3 + solid neutral OT20TPN-A OT20TPN-A
4 OT20FP-A OT20FP-A
3+ solid neutral OT32TPN-A OT32TPN-A
4 OT32FP-A OT32FP-A
3+ solid neutral OT63TPN-A OT63TPN-A
4 OT63FP-A OT63FP-A
3+ solid neutral OT100TPN-A OT100TPN-A
4 OT100FP-A OT100FP-A
3+ solid neutral OT125TPN-A OT125TPN-A
4 OT125FP-A OT125FP-A
3 + solid neutral OT160TPN-A OT160TPN-A
4 OT160FP-A OT160FP-A
3+ solid neutral OT200TPN-A OT200TPN-A
4 OT200FP-A OT200FP-A
3+ solid neutral OT315TPN-A OT315TPN-A
4 OT400FP-A OT400FP-A
3+ solid neutral OT400TPN-A OT400TPN-A
4 OT400TPN-A OT400TPN-A
3+ solid neutral OT630TPN-A OT630TPN-A
4 OT630FP-A OT630FP-A
3+ solid neutral OT800TPN-A OT800TPN-A
4 OT800TPN-A OT800TPN-A
Switchgear - Loadbreak switches IP65 Steel enclosure Spreader Boxes Suitable for Loadbreak Switches Product Hierarchy 3200003 Spreader Box Order Code Spreader Box Gasket Order Code OT20, OT32, OT63, OT100, OT125 Not Required OT160, OT200, OT315, OT400 SRN5420K GZ4020 OT630, OT800 SRN6425K GZ4025 Wall Mounting Brackets (Pack of 4) AA1206 Auxiliary Contacts
1 N/O OA1G10 OA1G10
1 N/C - only for OT20-125_ OA1G01 OA1G01
1 N/C - only for OT200 and above OA3G01 OA3G01
1 N/O - 1 N/C - OT20-125 and OT160 only OA2G11 OA2G11
Mounting module for OA2G11 - for OT160 only OAZX1 OAZX1
6 Enclosed Switching Products 0115 ABB Low Voltage 7 Enclosed Switching Products 0115 ABB Low Voltage
3 - 4 pole 20 ... 800A AC23 [kW] Dimensions Part Number Product Hierarchy 4000003 Order Code1thA 400V 500V 690V H W D No. Poles Fuse Type 20 7.5 11 15 300 300 150 3+detach neutral OS20TPN-A OS20TPN-A
4 OS20FP-A OS20FP-A
4 OS32FP-A OS32FP-A
4 OS63FP-A OS63FP-A
4 OS100FP-A OS100FP-A
4 OS125FP-A OS125FP-A
4 OS160FP-A OS160FP-A
200 110 132 200 600 400 250 3+detach neutral B1/B2 OS200TPN-A OS200TPN-A
4 OS200FP-A OS200FP-A
315 160 220 220 600 400 250 3+detach neutral B1/B4 OS315TPN-A OS315TPN-A
4 OS315FP-A OS315FP-A
400 220 280 400 600 400 250 3+detach neutral B1/B4 OS400TPN-A OS400TPN-A
4 OS400FP-A OS400FP-A
630 355 450 560 600 600 300 3+detach neutral C1/C2 OS630TPN-A OS630TPN-A
4 OS630FP-A OS630FP-A
800 450 560 710 800 600 300 3+detach neutral C1/C2 OS800TPN-A OS800TPN-A
4 OS800FP-A OS800FP-A
- IP65 rated (not suitable for external installation)
- Powder coated textured finish (RAL 7035)
- All switches are supplied with fuses and removable gland plates
- All 3 pole switches include detachable neutral link (OT160 solid link)
- Switch Fuses are internally rated IP20 on incoming terminals up to 63A
- Hinged lid complete with lock
- Padlockable pistol grip handle as standard
- Switch Fuses 100A are supplied with incoming terminal shrouds (NOT FITTED) to allow customer connections
- Spreader boxes available see below Note: OT630 & OT800 TPN/FP products are made to order and are non-stock items Spreader Boxes Spreader Box Spreader Box Gasket Suitable for Loadbreak Switches Part Number Product Hierarchy 3200003 Order Code Part Number Product Hierarchy 3200003 Order Code OS20 - OS125 Not Required - Not Required - OS160 SRN5420K SRN5420K GZ4020 GZ4020 OS200 - OS400 SRN6425K SRN6425K GZ4025 GZ4025 OS630 - OS800 SRN8530K SRN8530K GZ6030 GZ6030 Wall Mounting Brackets (Pack of 4) AA1206 AA1206 Auxiliary Contacts
1 N/C OA3G01 OA3G01
1 N/O - 1 N/C OA2G11 OA2G11
1 x CO contact - only for products OS20_/OS32_ OA4B1C OA4B1C Mounting frame to fit OA1/OA3 aux on left side of OS20/0S32 switch fuse (only for OS20_/OS32_ OSZ4 OSZ4 Switchgear - Switch fuses IP65 Steel enclosure
7 Enclosed Switching Products 0115 ABB Low Voltage
HRC fuse links, BS-type OFFNC 2 MADE IN ABB 415V 630A 2 / gG >80kA S04083 S04082 OFFNA 3 MADE IN ABB 415V 63A 3 / gG >80kA S04081 OFFNA 4 MADE IN ABB 415V 125A 4 / gG >80kA S04080 OFFNA 2 MADE IN ABB 415V 32A 2 / gG >80kA S04079 OFFNB 4 MADE IN ABB 415V 400A 4 / gG >80kA S04078 OFFNB 3 MADE IN ABB 415V 315A 3 / gG >80kA OFFNB 2 MADE IN ABB 415V 200A 2 / gG >80kA S04076 OFFNB 1 MADE IN ABB 415V 63A 1 / gG >80kA S04075 OFFNF 1 MADE IN ABB 415V 32A 1 / gG >80kA OFFNF1 OFFNA1 OFFNA2 OFFNA3 OFFNA4 OFFNB1 OFFNB2 OFFNB3 OFFNB4 OFFNC2 BS-fuse type In [A] Ph [W] Part Number Product Hierarchy
0002100007 Order Code
Tag type: Offset 2 0.9 OFFNF1GG2 1SCA107786R1001 4 1.5 OFFNF1GG4 1SCA107787R1001 6 1.5 OFFNF1GG6 1SCA107788R1001 10 1.2 OFFNF1GG10 1SCA107789R1001 16 1.6 OFFNF1GG16 1SCA107790R1001 20 1.7 OFFNF1GG20 1SCA107791R1001 25 2.0 OFFNF1GG25 1SCA107792R1001 32 2.9 OFFNF1GG32 1SCA107793R1001 Tag type: Offset, two holes fixing 20 2 0.9 OFFNA1GG2 1SCN833065R2012 4 1.5 OFFNA1GG4 1SCN833066R2012 6 1.5 OFFNA1GG6 1SCN833067R2012 10 1.2 OFFNA1GG10 1SCN833068R2012 16 1.6 OFFNA1GG16 1SCN833069R2012 20 1.7 OFFNA1GG20 1SCN833061R2012 25 2.0 OFFNA1GG25 1SCN833070R2012 32 2.9 OFFNA1GG32 1SCN833062R2012 6 1.5 OFFNA2GG6 1SCA107795R1001 10 1.2 OFFNA2GG10 1SCA107796R1001 16 1.6 OFFNA2GG16 1SCA107798R1001 20 1.7 OFFNA2GG20 1SCA107827R1001 25 2.0 OFFNA2GG25 1SCA107800R1001 32 2.9 OFFNA2GG32 1SCA107801R1001 40 3.0 OFFNA3GG40 1SCA107803R1001 50 3.6 OFFNA3GG50 1SCA107804R1001 63 4.7 OFFNA3GG63 1SCA107805R1001 50 3.6 OFFNA4GG50 1SCA107806R1001 63 4.7 OFFNA4GG63 1SCA107807R1001 80 6.5 OFFNA4GG80 1SCA107808R1001 100 7.5 OFFNA4GG100 1SCA107809R1001 125 11.5 OFFNA4GG125 1SCA107810R1001 160 14.5 OFFNA4GG160 1SCN833063R2012 200 16.2 OFFNA4GG200 1SCN833064R2012 50 4.8 OFFNB1GG50 1SCA107811R1001 63 5.9 OFFNB1GG63 1SCA107812R1001 80 6.5 OFFNB1GG80 1SCA107813R1001 100 7.5 OFFNB1GG100 1SCA107814R1001 125 11.5 OFFNB2GG125 1SCA107816R1001 160 14.5 OFFNB2GG160 1SCA107817R1001 200 16.2 OFFNB2GG200 1SCA107818R1001 Tag type: Central, two holes fixing 10 250 24.0 OFFNB3GG250 1SCA107819R1001 315 31.0 OFFNB3GG315 1SCA107820R1001 400 38.0 OFFNB4GG400 1SCA107822R1001 Tag type: Central, four holes fixing C1 400 38.0 OFFNC1GG400 1SCA107823R1001 500 48.0 OFFNC2GG500 1SCA107824R1001 630 54.0 OFFNC2GG630 1SCA107825R1001 C3 800 68.0 OFFNC3GG800 1SCA107826R1001 S04082 OFFNA 1 MADE IN ABB 415V 32A 1 / gG >80kA BS Fuses
8 Enclosed Switching Products 0115 ABB Low Voltage 9 Enclosed Switching Products 0115 ABB Low Voltage Securing your power supply | 5 In today’s world, electrical power plays a key role in almost every activity of our life. For some equipment a reliable, uninterruptible and free of disturbance power supply is an absolute need. From this point of view, a fault in the power supply of communications systems, hospital apparatus, security systems, water and gas distribution devices, banking computers and many other crucial appliance may bring about serious problems, with consequences that can easily be imagined. All these applications can be identified as “Critical Power” applications: they are specifically designed to leverage a constant and secure power supply, for example using UPS equipment or power generators. In the area of “Critical Power” ABB can offer a wide range of products, including both components for on board installation and complete power distribution systems. These products range from low voltage generators for generator sets (Gen-set) to iPDU (intelligent Power Distribution Units) switchboards, and include all types of equipment specifically required to provide safety and reliability: air, moulded-case and miniature circuit breakers, protections against overvoltages, isolators and switch-disconnectors, contactors, manual and motorized change-over switches, automatic transfer switches and automatic control units, current sensors and many other devices. ABB products comply with the most important international standards - either European or North American - and with the requirements of the Navy Registry; they are also designed and built on the basis of the most modern and advanced environmental standards. ABB products are backed by a consolidated experience in power and automation technologies. They are supported through a global assistance and service network which covers more than 100 countries all over the world. 4 | Securing your power supply Constant commitment ABB’s solutions and products to ensure continuity of operation Critical applications require a constant and reliable power supply to keep fundamental services running and prevent serious consequences due to interruption or absence of the electrical grid. This need is even stronger nowadays because of the increasing significance of key role, capacity and features of these systems. In order to ensure the high level of reliability requested, the system must include generators and UPS equipment which ensure the right power supply to the critical loads in case of grid failure. Critical power applications require a constant and reliable power supply to keep fundamental services running and prevent serious consequences caused by the interruption or absence of the electrical grid. Selection of a source of switching, control and protection capable of sustaining the needs of a critical power application is paramount, ABB has a well proven track record within this environment. Enclosed manual and automatic transfer switches ABB low voltage component capabilities for critical power applications
9 Enclosed Switching Products 0115 ABB Low Voltage Securing your power supply | 5
In today’s world, electrical power plays a key role in almost every activity of our life. For some equipment a reliable, uninterruptible and free of disturbance power supply is an absolute need. From this point of view, a fault in the power supply of communications systems, hospital apparatus, security systems, water and gas distribution devices, banking computers and many other crucial appliance may bring about serious problems, with consequences that can easily be imagined. All these applications can be identified as “Critical Power” applications: they are specifically designed to leverage a constant and secure power supply, for example using UPS equipment or power generators. In the area of “Critical Power” ABB can offer a wide range of products, including both components for on board installation and complete power distribution systems. These products range from low voltage generators for generator sets (Gen-set) to iPDU (intelligent Power Distribution Units) switchboards, and include all types of equipment specifically required to provide safety and reliability: air, moulded-case and miniature circuit breakers, protections against overvoltages, isolators and switch-disconnectors, contactors, manual and motorized change-over switches, automatic transfer switches and automatic control units, current sensors and many other devices. ABB products comply with the most important international standards - either European or North American - and with the requirements of the Navy Registry; they are also designed and built on the basis of the most modern and advanced environmental standards. ABB products are backed by a consolidated experience in power and automation technologies. They are supported through a global assistance and service network which covers more than 100 countries all over the world. In today’s world, electrical power plays a key role in almost every activity of our life. For some equipment a reliable, uninterruptible and free of disturbance power supply is an absolute essential. From this point of view, a fault in the power supply of communications systems, hospital apparatus, security systems, water and gas distribution devices, banking computers and many other crucial applications may bring about serious problems, with consequences that can be devastating. All these applications can be identified as “Critical Power” applications: ABB can offer a wide range of components for on board installation and complete power distribution systems. These products include:- automatic transfer switches (ATS) and automatic control units (ACU), manual and motorised change-over switches, isolators, switch-disconnectors, Air and moulded-case circuit breakeres and miniature circuit breakers, protection devices against overvoltages, contactors, current sensors and many other devices. ABB products comply with the most important international standards and European or North American - and with the requirements of the Navy Registry; they are also designed and built on the basis of the most modern and advanced environmental standards. ABB products are backed by a consolidated experience in power and automation technologies. They are supported through a global assistance and service network which covers more than 100 countries all over the world. 4 | Securing your power supply Constant commitment ABB’s solutions and products to ensure continuity of operation Critical applications require a constant and reliable power supply to keep fundamental services running and prevent serious consequences due to interruption or absence of the electrical grid. This need is even stronger nowadays because of the increasing significance of key role, capacity and features of these systems. In order to ensure the high level of reliability requested, the system must include generators and UPS equipment which ensure the right power supply to the critical loads in case of grid failure.
10 Enclosed Switching Products 0115 ABB Low Voltage 11 Enclosed Switching Products 0115 ABB Low Voltage
Enclosed manual & automatic transfer switches Functionality & features As industrial processes and IT applications diversify, a secure power supply is becoming an increasingly important asset in the drive to cut production and maintenance costs. In emergency situations, the system logic of power distribution can become complex with mechanical devices looking after the making, breaking, conducting and isolating of power. Loads may sometimes need to be transferred from one supply to another — this will be the case when energy use is restricted or when the supply source is overloaded. High performance level In change-over applications where the loaded switch may need to be operated remotely, adequate durability has been ensured by testing against the IEC 60947-6-1 standard in the specification of endurance requirements. Utillisation categories: − AC-31 for non-inductive or slightly inductive load − AC-33 for motor loads or mixed loads including motors ABB change-over switches are rated according to IEC 60947-6-1 standard. ATS isolator Bypass supply selection switch Closed transition ATS bypass switch Automatic transfer controller Automatic transfer switch ABB products for GEN SET Circuit breaker - ACB, MCCB - MCB Control panel - ATS Panels (Change-over switch, monitoring relays, push buttons) 6 | GEN SET and UPS manufacturers Alternator Paralleling Switchgears GEN SET and UPS manufacturers | 7
11 Enclosed Switching Products 0115 ABB Low Voltage
Fig. 1 ATS automatic transfer switch with dual supply bypass Standard ATS without bypass with blank door with pilot lights showing healthy supplies ATS controller mounted on door OMD300 controller OMD800 controller
12 Enclosed Switching Products 0115 ABB Low Voltage
Enclosed automatic transfer switches General information Automatic transfer switches Automatic transfer switches comply with the standards listed below.
- IEC 60947-1: Low voltage switchgear and control gear Part 1: General rules
- IEC 60947-3: Low voltage switchgear and control gear Part 3: Switches, disconnectors, switch-disconnectors and fuse-combination
- IEC 60947-6-1-PC: Low voltage switchgear and control gear Part 6: Multiple function equipment – Transfer switching equipment Application The automatic transfer switch is managing different power supplies to one or more load circuits and guarantees the continuity of performance. The automatic transfer switch ensures the switching and isolation between the primary network supply and the alternate network supply or a standby generator. Type of operation is open transition, i.e. break-before-make. The automatic transfer switches can be operated in three ways, local manual operation with handle, local manual operation with the automatic control unit or full automatic operation done by the automatic control unit. Manual operation, using a handle is the simplest type of operation. Local manual operation with the control unit enables to operate the switch electrically. Full automatic operation ensures that loads are transferred automatically to the secondary source in case of mains failure. Both local operation with the control unit and full automatic operation enables a short switch-off time between the normal and the alternative supply. Automatic transfer switches shall be used for switching I, 0 and II positions following types of loads:
- Off load application (AC 20A)
- Resistive loads (AC 21 or AC31)
- Mixed resistive and inductive loads (AC 22)
- Motor loads Design & safety Automatic transfer switches are available as 3 or 4 pole versions. All three positions I, 0 and II shall be stable and keep its positions in case of supply failure or mechanical shocks. The switch mechanism is located on the left hand side to the switch’s power poles. The operating mechanism is of “quick make / quick break” construction. The position indication markings on the mechanism shall always show reliably the true position of the main contacts. Automatic transfer switchs can be operated by direct mounted handle and the handle shall be showing reliably the real position of the main contacts of the transfer switch. The handle will allow the switch to be padlocked in the off position. The automatic transfer switch is constructed with a motor operator. The motor operator is protected against overloads with a separate overload fuse (160A to 1600A). The fuse is situated at the bottom of the Motor. The 40A to 125A motor is protected by a resettable overload button. The accessories, i.e. terminal shrouds and auxiliary contacts shall be mountable without any special tools (i.e. snap on mounting). The terminals of the 160A to 1600A automatic transfer switch it is possible to connect two parallel cables for easier installation and space saving. All the terminals shall be finger protected with or without separate terminal shrouds. All the metal parts shall be protected against corrosion. The contact surfaces shall be silver- plated to minimise contact resistance. The automatic transfer switches meet the ROHS requirements and only recyclable material is used. The current carrying plastic parts shall have high thermal, mechanical and electrical properties and have V0 classification. The voltage sensing wiring from the switch’s power poles to the automatic control unit is done by the automatic transfer switch manufacturer. Voltage sensing wires are double insulated. Enclosed automatic transfer switches with current ratings 40A … 1600A. The enclosure complies with IP65 EN 60529 and finished in a RAL 7035 colour. The ATS enclosures are designed to allow adequate cabling space to allow installers to terminate oversized cables.
Enclosed automatic transfer switches General & technical specification Specific ratings according to IEC 60947-3 40A to 125A Rated free air thermal current (Ith) and operational current in AC20 at 40°C ambient temperature A 40 63 80 115 125 Rated enclosed thermal current (Ith) and operational current in AC20 at 40°C ambient temperature A 40 63 80 115 125 Rated operational current AC 21A and AC 22A at voltages up to 500V A 40 63 80 100 125 Rated operational current AC23A at voltages up to 415V A 40 63 80 80 90 Rated AC 23 breaking capacity at 415V A 320 504 640 640 720 and corresponding max. allowed cut-off current of gG A 125 125 125 125 125 Mechanical endurance / switch Oper 20000 20000 20000 20000 20000 Rated short-time withstand current Icw (r.m.s.) 690V, 0,1 sec kA 5 5 5 5 5 Rated operational current, AC-31B, up to 415V A 40 63 80 100 125 Rated operational current, AC-33B, up to 415V A 40 63 80 80 80 The handle is a direct mounted type, and it shall be padlockable in the “0” position with three padlocks with 5 …6 mm. It is possible to operate switch with the manual handle in case of emergency, regardless of the position of switch and without any supply power. Technical specifications according to IEC 60947-3 and IEC 60947-6-1
- Type of equipment ATSE
- Class of equipment PC
- Rated operational voltage, Ue Max. 415 V
- Rated impulse withstand voltage, Uimp 6 kV
- Rated frequency 50 - 60 Hz
- EMC environment A and B Bypass Requirement In order to comply with BS8519 which states “Where the availability of the life safety and fire-fighting equipment is conditional to the occupation of the building, a bypass arrangement should be incorporated to enable the changeover device to be maintained without loss of service from the critical plant”. The bypass switches consist of the following; Single or mains bypass A closed transition manual changeover switch is included to allow for the seamless (no 0 position giving no break in supply when moving to bypass) transition to bypass. The front of the panel should indicate that the ATS has been bypassed and is safe to carry out maintenance. Dual Bypass A closed transition manual changeover switch is included to allow for the seamless (no 0 position giving no break in supply when moving to bypass) transition to bypass. Together with a standard manual changeover switch to allow you to choose between supply 1 or supply 2. The front of the panel should indicate that the ATS has been bypassed and which supply is feeding the load and is safe to carry out maintenance. Specific ratings according to IEC 60947-3 160A to 1600A Rated free air thermal current (Ith) and operational current in AC20 at 40°C ambient temperature A 160 200 250 315 400 630 800 1000 1250 1600 Rated enclosed thermal current (Ith) and operational current in AC20 at 40°C ambient temperature A 160 200 250 315 400 630 800 1000 120 1600 Rated operational current AC 21A and AC 22A at voltages up to 415V A 160 200 250 315 400 630 800 1000 1250 1600 Rated operational current AC23A at voltages up to 415V A 160 200 250 315 400 630 800 1000 1250 1250 Rated AC 23 breaking capacity at 415V A 1280 1600 2000 2520 3200 5040 6400 10000 10000 10000 and corresponding max. allowed cut-off current of gG A 355 355 355 500 500 800 800 1250 1250 1250 Rated short time withstand current Icw 690v (1sec), (r.m.s. value) kA 8 8 8 15 15 20 20 50 50 50 Rated short time making capacity Icm, peak value 690v kA 30 30 30 65 65 80 80 92 92 92 Mechanical endurance / switch Oper 16000 16000 16000 16000 16000 10000 10000 6000 6000 6000 Rated short-time withstand current Icw (r.m.s.) 690V, 0,1 sec kA 15 15 15 25 25 38 38 50 50 50 Rated operational current, AC-31B, up to 415V A 160 200 250 315 400 650 720 1000 1250 1600 Rated operational current, AC-33B, up to 415V A 160 200 250 315 400 650 650 1000 1000 1000
14 Enclosed Switching Products 0115 ABB Low Voltage 15 Enclosed Switching Products 0115 ABB Low Voltage
OTM_C3D OTM_C8D 1. Automatic transfer switch products overview 1.1. Automatic control unit OMD300 OMD800 1.1. Manual operation with handle X X 1.2. Local operation with front panel keypad X X 1.3. Automatic transfer switching equipment (ATSE) X X 1.4. Dual power source for the motor operator 1) X O 2. Measurements 2.1. Three phase voltage measurement on LINE1 X X 2.2. Single phase voltage measurement on LINE1 X X 2.3. Three phase voltage measurement on LINE2 X X 2.4. Single phase voltage measurement on LINE2 X X 2.5. Frequency on LINE1 X X 2.6. Frequency on LINE2 X X 2.7. Possibility to check measurements on LCD X 3. Source failure detections 3.1. No voltage X X 3.2. Undervoltage X X 3.3. Overvoltage X X 3.4. Phase missing X X 3.5. Voltage unbalance X X 3.6. Invalid frequency X X 3.7. Incorrect phase sequence X 4. Configuration 4.1. By DIP switches X 4.2. By rotary switches X 4.3. By keypad and LCD X 4.4. Voltage threshold setting X X 4.5. Voltage hysteresis setting X 4.6. Frequency threshold setting X 4.7. Frequency hysteresis setting X 5. Time delays 5.1. Switching delay X 2) X 5.2. Delay on transfer 3) X 5.3. Dead band time I-II (stop switching to position O) X 5.4. Back-switching delay X 4) X 5.5. Dead band time II-I (stop switching to position O) X 5.6. Generator stop delay X 5) X 5.7. Status of time delays on the LCD X In the enclosed ATS the dual power source is included Comments 1) Dual power source allows the motor operator to be supplied by two separate voltage supplies. This way the motor operator is always energized. 2) Four options: 0, 5, 10 or 30 seconds. 3) Delaying the switching sequence before transferring to generator, guaranteeing that in cold locations the generator is properly heated up. 4) Two options: the duration of back-switching delay is the same as switching delay, i.e. the time delay is same for I - II and II - I, or the back-switching delay is fixed 300 seconds. 5) Two options: the duration of generator stop delay is the same as Switching delay or fixed 5 min. 6) Menus available in eight languages; English, French, German, Italian, Spanish, Russian, Chinese and Finnish. 7) Two-way communication, bus communication protocol is Modbus 8) In case of source failure, the controller can be supplied with an external auxiliary supply with 24…110 V DC. 9) Automatic control unit requires an external signal before allowing the transfer to secondary. 10) Two options for the operating mode after receiving the alarm: control unit either works normally, or initiates generator stop with operation to position O. 11) Two options: No line priority, or Source 1 is the priority source. 12) Three options: No line priority, Source 1 or Source 2 is the priority source. 13) Automatic back-switching to primary source is prevented. 14) Automatic control unit and motor operator must be energized. X = includes as standard O = as an accessory Enclosed automatic transfer switches Controllers technical specification
15 Enclosed Switching Products 0115 ABB Low Voltage
OTM_C3D OTM_C8D 6.1. Features 6.2. Generator start and stop X X 6.3. OFF-load test sequence X X 6.4. ON-load test sequence X X 6.5. Source status via front panel X X 6.6. Source status via digital outputs X 6.7. Switch position via front panel X X 6.8. LCD 6) X 6.9. Fieldbus interface 7) X 6.10. Event/alarm log X 6.11. Counter for number of operations X 6.12. Auxiliary voltage supply 8) X 6.13. Programmable digital inputs (eight) and digital outputs (six) X 6.14. Secondary load control (load shedding) X 6.15. Digital input – Allow transfer to secondary 9) X 6.16. Digital input - Generator alarm 10) X 6.17. Digital input - Remote control to positions I, O and II X 7. Operating mode 7.1. Line priority X 11) X 12) 7.2. Manual back-switching 13) X X 7.3. Automatic operation to position O, in case of source failure 14) X 8. Applications 8.1. Transfer between two transformers X X 8.2. Transfer between a transformer and a generator X X In the enclosed ATS the dual power source is included Comments 1) Dual power source allows the motor operator to be supplied by two separate voltage supplies. This way the motor operator is always energized. 2) Four options: 0, 5, 10 or 30 seconds. 3) Delaying the switching sequence before transferring to generator, guaranteeing that in cold locations the generator is properly heated up. 4) Two options: the duration of back-switching delay is the same as switching delay, i.e. the time delay is same for I - II and II - I, or the back-switching delay is fixed 300 seconds. 5) Two options: the duration of generator stop delay is the same as Switching delay or fixed 5 min. 6) Menus available in eight languages; English, French, German, Italian, Spanish, Russian, Chinese and Finnish. 7) Two-way communication, bus communication protocol is Modbus 8) In case of source failure, the controller can be supplied with an external auxiliary supply with 24…110 V DC. 9) Automatic control unit requires an external signal before allowing the transfer to secondary. 10) Two options for the operating mode after receiving the alarm: control unit either works normally, or initiates generator stop with operation to position O. 11) Two options: No line priority, or Source 1 is the priority source. 12) Three options: No line priority, Source 1 or Source 2 is the priority source. 13) Automatic back-switching to primary source is prevented. 14) Automatic control unit and motor operator must be energized. X = includes as standard O = as an accessory Enclosed automatic transfer switches Controllers technical specification
16 Enclosed Switching Products 0115 ABB Low Voltage 17 Enclosed Switching Products 0115 ABB Low Voltage
Enclosed manual & automatic transfer switches Selection (A) Enclosure Size (mm) Order CodeH W D MTS 40A 40 400 300 150 OT40FPC-B MTS 63A 63 400 300 150 OT63FPC-B MTS 80A 80 400 300 150 OT80FPC-B MTS 100A 100 500 400 250 OT100FPC-B MTS 125A 125 500 400 250 OT125FPC-B MTS 160A 160 600 400 250 OT160FPC-B MTS 200A 200 600 400 250 OT200FPC-B MTS 250A 250 600 400 250 OT250FPC-B MTS 315A 315 800 600 300 OT315FPC-B MTS 400A 400 800 600 300 OT400FPC-B MTS 630A 630 1000 600 400 OT630FPC-B MTS 800A 800 1000 600 400 OT800FPC-B (A) Enclosure Size (mm) Controller OMD300 H W D Part Number Order Code ATS 40A 40 600 600 250 OTA40E4C3SR 1TVC004014S3000 ATS 63A 63 600 600 250 OTA63E4C3SR 1TVC006314S3000 ATS 125A 125 600 600 250 OTA125E4C3SR 1TVC012514S3000 ATS 160A 160 600 600 250 OTA160E4C3SR 1TVC016014S3000 ATS 250A 250 600 600 250 OTA250E4C3SR 1TVC025014S3000 ATS 400A 400 800 600 300 OTA400E4C3SR 1TVC040014S3000 ATS 630A* 630 1000 800 400 OTA630E4C3AM 1TVC063024S3000 ATS 800A* 800 1000 800 400 OTA800E4C3AM 1TVC080024S3000 ATS 1000A* 1000 1400 800 500 OTA1000E4C3AM 1TVC100024S3000 ATS 1250A* 1250 1400 800 500 OTA1250E4C3AM 1TVC125024S3000 ATS 1600A* 1600 1400 800 500 OTA1600E4C3AM 1TVC160024S3000 (A) Enclosure Size (mm) Controller OMD800 H W D Part Number Order Code ATS 40A 40 600 600 250 OTA40E4C8SR 1TVC004014S8000 ATS 63A 63 600 600 250 OTA63E4C8SR 1TVC006314S8000 ATS 125A 125 600 600 250 OTA125E4C8SR 1TVC012514S8000 ATS 160A 160 600 600 250 OTA160E4C8SR 1TVC016014S8000 ATS 250A 250 600 600 250 OTA250E4C8SR 1TVC025014S8000 ATS 400A 400 800 600 300 OTA400E4C8SR 1TVC040014S8000 ATS 630A* 630 1000 800 400 OTA630E4C8AM 1TVC063024S8000 ATS 800A* 800 1000 800 400 OTA800E4C8AM 1TVC080024S8000 ATS 1000A* 1000 1400 800 500 OTA1000E4C8AM 1TVC100024S8000 ATS 1250A* 1250 1400 800 500 OTA1250E4C8AM 1TVC125024S8000 ATS 1600A* 1600 1400 800 500 OTA1600E4C8AM 1TVC160024S8000 * Floor standing - plinths from accessories below. Bypass options are available on request. Other wall mounting and floor standing versions available on request. Enclosed manual transfer switches, I-O-II operation, open transition
- MTS 4 pole 40 to 800A with blank door, wall mountable Enclosed automatic transfer switches, I-O-II operation, open transition
- ATS 4 pole 40 to 1600A with OMD300 & OMD800 controller, blank door, wall mountable
17 Enclosed Switching Products 0115 ABB Low Voltage
Enclosed single bypass switches, I-O-II operation, open transition
- BPS 4 pole 40 to 630A with OMD800 controller, blank door, wall mountable
(A) Enclosure Size (mm) Single Bypass Controller OMD800 H W D Order Code BPS 40A 40 1000 800 300 OTA40E4C8SBSR BPS 63A 63 1000 800 300 OTA63E4C8SBSR BPS 100A 100 1000 800 300 OTA100E4C8SBSR BPS 125A 125 1000 800 300 OTA125E4C8SBSR BPS 160A 160 1200 1000 400 OTA160E4C8SBSR BPS 250A 250 1200 1000 400 OTA250E4C8SBSR BPS 400A 400 1200 1000 400 OTA400E4C8SBSR BPS 630A 630 1600 1200 600 OTA630E4C8DBAM Enclosed dual bypass switches, I-O-II operation, open transition
- BPS 4 pole 40 to 630A with OMD800 controller, blank door, wall mountable
(A) Enclosure Size (mm) Dual Bypass Controller OMD800 H W D Order Code BPS 40A 40 1000 800 300 OTA40E4C8DBSR BPS 63A 63 1000 800 300 OTA63E4C8DBSR BPS 100A 100 1000 800 300 OTA100E4C8DBSR BPS 125A 125 1000 800 300 OTA125E4C8DBSR BPS 160A 160 1200 1000 400 OTA160E4C8DBSR BPS 250A 250 1200 1000 400 OTA250E4C8DBSR BPS 400A 400 1200 1000 400 OTA400E4C8DBSR BPS 630A 630 1600 1200 600 OTA630E4C8DBAM Enclosed manual & automatic transfer switches Selection
18 Enclosed Switching Products 0115 ABB Low Voltage
Enclosed manual & automatic transfer switches Accessories Optional extras Description Part Number Order Code 2 pilot lights ATS2PL 1TVC151800S2311 Door mounted controller complete with IP54 cover plate ATSDMC 1TVC151800S2312 Energy meter ATSEM 1TVC151800S2313 Aniti-condensation heater with thermostat ATSHT 1TVC151800S2314 Accessories Description Suitable switch Part Number Order Code N/O auxiliary for on right hand side of switch OTA40-1600 OA1G10 1SCA022673R1140 N/O auxiliary for on left hand side of switch OTA40-125 OA7G10 1SCA022744R2240 N/C auxiliary for on right hand side of switch OA8G01 1SCA022353R4890 N/C auxiliary for on left hand side of switch OA1G01 1SCA022456R1710 N/C auxiliary for on right hand side of switch OTA160-1600 OA3G01 1SCA022456R7410 Direct mounting handle, padlockable with 3 padlocks in ‘0‘ position. Includes shaft and mech cover OTA40-125 OHB65D6CM 1SCA022870R9430 OTA160-250 OTV250ECMK 1SCA022804R0570 OTA400 OTV400ECMK 1SCA022843R2900 OTA630-800 OTV800ECMK 1SCA022804R3410 OTA1000-1600 OTV1000ECMK 1SCA111301R1001 Handle and spare fuse storage clip OTA40-125 OTVS0 1SCA117524R1001 OTA160-250 OTVS1 1SCA111413R1001 OTA400-1600 OTVS2 1SCA111414R1001 IP54 cover plate for door mounting ATS controller All OMZC2 1SCA101001R1001 Yale type key, 19mm dia box with security insert OTA40-400 AA8002 AA8002 Unique coded Yale insert lock OTA630-1600 EV1036 EV1036 A4 Document pocket All EV1075K EV1075K Blind plinth flanges (pair) H100 x W800mm OTA630-1600 ZN8000 ZN8000 Blind plinth flanges (pair) H100 x D400mm OTA630-800 ZN4011 ZN4011 Blind plinth flanges (pair) H100 x D500mm OTA1000-1600 ZN5011 ZN5011 Wall mounting brackets (4 off) OTA40-400 AA1206 AA1206 Anti tilting brackets (pair) OTA630-1600 TA1207 TA1207 Enclosed Automatic Transfer Switch with ATS2PL & ATSDMC optional extras
20 Enclosed Switching Products 0115 ABB Low Voltage
© Copyright ABB Ltd 9AKK106354A1406 Contact us ABB Ltd Tower Court Foleshill Enterprise Park Courtaulds Way Coventry CV6 5NX Tel: 0333 999 9900 Fax: 0333 999 9901 Email: LV.Enquiries@gb.abb.com Twitter: @ABBUKLVP www.abb.co.uk/lowvoltage Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB Ltd does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents – in whole or in parts – is forbidden without prior written consent of ABB Ltd. Copyright © 2015 ABB Ltd All rights reserved Power and productivity for a better world TM