Business-Critical Continuity ASA Series
10 Watts
- E n c a p s u l a t e d
- 2:1 input range
- 1.25" X 0.8” DIP package
- 1500Vdc I/O isolation
- Single output Total Power: 10 Watts Input Voltage: 24V or 48V # of Outputs: Single Electrical Specifications Safety Input Input ra nge 18 to 36 VDC; 36 to 75 VDC Efficiency2 83%@12Vo Output Voltage tolerance ±2.0% Line regulation ±0.8% Load regulation ±1.2% Noise/ripple 100mV for 2.5Vo, 3.3Vo and 5.0Vo 120mV for 12Vo Short circuit protection Auto-restart Switching frequency 350KHz Temperature coefficient ±0.02 /°C Isolation I/O isolation 1500 VDC min. Insulation resistance 10Mohm Insulation capacitance 1000pF CE Mark Rev. 01.30.08 ASA 10W Series 1 of 2 Operating ambient temperature range -40°C to +60°C (no derating) Storage temperature -55°C to +105°C Humidity 5% to 95% (non-condensing) MTBF 1 Mhrs demonstrated MTBF RoHS Compliant Environmental Specifications RoHS
Business-Critical Continuity Mechanical Drawing
Ordering Information
Voltage Output 1 Voltage Output 2 Voltage Maximum Power Model Number 18 - 36 V 2.5 V @ 3 A 7.5 W ASA03G24-L 18 - 36 V 3.3 V @ 3 A 10 W ASA03F24-L 18 - 36 V 5 V @ 2 A 10 W ASA02A24-L 18 - 36 V 12 V @ 0.835 A 10 W ASA00B24-L 36 - 75 V 2.5 V @ 3 A 7.5 W ASA03G48-L 36 - 75 V 3.3 V @ 3 A 10 W ASA03F48-L 36 - 75 V 5 V @ 2 A 10 W ASA02A48-L 36 - 75 V 12 V@ 0.835 A 10 W ASA00B48-L Please contact Astec for information on other output voltages, power ranges and configurations. Available in RoHS 6 version only. Rev. 01.30.08 ASA 10W Series 2 of 2 2.54 (0.10) 20.32 (0.80) 3.05 (0.12) Label 10.16 (0.40) 31.75 (1.25) Bottom View 22.86 (0.90) ӽ0.50 (0.02) 15.24 (0.60) ASTEC ASA02A48-L IN=48Vdc Nom. OUT=5Vdc RoHS Date Code Dot Dot -Vin NC NCˀVin +Vin -Vout +Vout+Vin Top View 5.08 (0.20) Pb Notes: 1. All specifications subject to change without notice. Mechanical drawings are for reference only. 2. Warranty: 1 yr 3. Label and logo appearance may vary from what is shown on mechanical drawings. Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2008 Emerson Electric Co. EmersonNetworkPower. com Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection Americas
5810 Van Allen Way
Carlsbad, CA 92008 USA Telephone: +1 (760) 930 4600 Facsimile: +1 (760) 930 0698 Europe (UK) Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 Asia (HK) 14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888 For global contact, visit: www.powerconversion.com techsupport.embeddedpower @emerson.com While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power