MODEL: AS4V AS4V SPECIFICATIONS ES-1609 Rev.20 Page 1/5 https://www.m-system.co.jp/ Plug-in Signal Conditioners M-UNIT DC ALARM (dual or quad alarm trip; field-configurable) Functions & Features

  • Provides relay outputs at preset DC input levels
  • Quad or dual trip
  • Setting and display in engineering unit values
  • Setpoint adjustments with the front keypad
  • Software lock
  • Adjustable hysteresis (deadband)
  • On-delay timer
  • Hi/Lo trip and energized/de-energized coil independently selectable for each setpoint
  • Enclosed relays
  • Relays can be powered by 200 V AC and 100 V DC
  • High-density mounting on DIN rail Typical Applications
  • Annunciator
  • Various alarm applications (1.97) 132 (5.20) (3.15) mm (inch) MODEL: AS4V–[1][2]–[3][4]

ORDERING INFORMATION

  • Code number: AS4V-[1][2]-[3][4] Specify a code from below for each of [1] through [4]. (e.g. AS4V-S22-R/UL/Q)
  • Specify the specification for option code /Q (e.g. /C01/SET) [1] INPUT Current Z1: Range 0 – 50 mA DC (Input resistance 100 Ω) Voltage S1: Range -1 – +1 V DC (Input resistance 1 MΩ min.) S2: Range -10 – +10 V DC (Input resistance 1 MΩ min.) [2] OUTPUT 2: 4 points; N.O. or make contact 3: 4 points; N.C. or break contact 5: 2 points; SPDT or transfer contact 2A: 4 points; N.O. or make contact (small load current) (CE not available. Option /UL Not selectable.) 3A: 4 points; N.C. or break contact (small load current) (CE not available. Option /UL Not selectable.) 5A: 2 points; SPDT or transfer contact (small load current) (CE not available. Option /UL Not selectable.) [3] POWER INPUT AC Power M2: 100 – 240 V AC, 50 – 60 Hz (Operational voltage range 85 – 264 V, 47 – 66 Hz) DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) P: 110 V DC (Operational voltage range 85 – 150 V, ripple 10 %p-p max.) [4] OPTIONS (multiple selections) Standards & Approvals blank: CE marking /UL: UL approval, CE marking Other Options blank: none /Q: Option other than the above (specify the specification) SPECIFICATIONS OF OPTION: Q (multiple selections) COATING (For the detail, refer to M-System's web site.) /C01: Silicone coating /C02: Polyurethane coating /C03: Rubber coating (UL not available) TERMINAL SCREW MATERIAL /S01: Stainless steel (UL not available) EX-FACTORY SETTING /SET: Preset according to the Ordering Information Sheet (No. ESU-1609) GENERAL SPECIFICATIONS Construction: Plug-in Connection: M3.5 screw terminals Screw terminal: Chromated steel (standard) or stainless steel Housing material: Flame-resistant resin (black) Isolation: Input to output to power Sampling cycle: 100 msec. User-configurable items: Front key pad
  • Alarm setpoint

MODEL: AS4V AS4V SPECIFICATIONS ES-1609 Rev.20 Page 2/5 https://www.m-system.co.jp/

  • Display range scaling
  • Power ON-delay time
  • Alarm ON-delay time
  • Moving average
  • Hi/Lo trip operation
  • Coil at alarm
  • Hysteresis (deadband)
  • 0 %, 100 % input setting
  • Latching control
  • Others (Refer to the instruction manual) ■ DISPLAY LED: 8 mm (.31”) 7 segment, red Number of display digits: 4 digits for DATA display; 2 digits for ITEM display Range: -1999 to 9999 (decimal point position selectable) PV indication: Input signal in engineering unit Overrange indication: LEDs blinking Power saving mode: Displays turn off if the keys are untouched for a preset time period LEDs: Red LEDs turn on when coils are energized. (L1 and L2 for 2-point alarm. L1, L2, L3 and L4 for 4-point alarm.) INPUT SPECIFICATIONS ■ DC Current: 0 – 50 mA DC; shunt resistor attached to input terminals (0.5 W) Operational range: 0 – 70 mA DC (with 100 Ω / 0.5 W) Minimum increment: 0.1 mA Default setting: 4 – 20 mA DC ■ DC Voltage: -1 – +1 V DC for S1; -10 – +10 V DC for S2 Operational range: -1.15 – +1.15 V DC for S1; -11.5 – +11.5 V DC for S2 Minimum increment: 10 mV for S1; 100 mV for S2 Default setting: -1 – +1 V DC for S1; -10 – +10 V DC for S2 OUTPUT SPECIFICATIONS ■ Quad Alarm Relay rating:

120 V AC @ 1 A (cos ø = 1)

240 V AC @ 0.5 A (cos ø = 1)

30 V DC @ 1 A (resistive load)

Maximum switching voltage(Note): 380 V AC or 125 V DC Maximum switching power(Note): 120 VA or 30 W Minimum load: 5 V DC @ 10 mA Mechanical life: 5 × 107 cycles ■ Dual Alarm Relay rating:

120 V AC @ 5 A (cos ø = 1)

240 V AC @ 2.5 A (cos ø = 1)

30 V DC @ 5 A (resistive load)

Maximum switching voltage(Note): 380 V AC or 125 V DC Maximum switching power(Note): 600 VA or 150 W Minimum load: 5 V DC @ 10 mA Mechanical life: 5 × 107 cycles ■ Small load current type Relay rating: 30 V DC @ 1 A (resistive load) Maximum switching voltage(Note): 220 V DC Maximum switching power(Note): 30 W (resistive load) Minimum load: 1 V DC @ 1 mA Mechanical life: 5 × 107 cycles (Note): The value indicate capacity of output relay in equipment. Use within relay rating for EU and UL. 0 50 100 ▲ Input (%) LL L ▲ ▲ HH H L2 (1–2) ON L3 (1–3) ON L4 (9–11) ON OFF OFF L1 (9–10) ON OFF OFF Alarm Trip Operation Terminal No. in parentheses Example with quad N.O. contacts (LL, L, H, HH) Trip Operation in Power Failure

  • Output code 2, 2A: All relays turn off.
  • Output code 3, 3A: All relays turn on.
  • Output code 5, 5A: Terminals 1 – 3, 9 – 11 turn on. INSTALLATION Power consumption
  • AC: ≤ 6 VA
  • DC: ≤ 3.5 W Operating temperature: -5 to +55°C (23 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 500 g (1.1 lb) PERFORMANCE in percentage of FS input Setpoint accuracy (trip point accuracy): ±(0.1 % of FS + 1 digit) Display accuracy: ±(0.1 % of FS + 1 digit) Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) Response time: ≤ 0.5 sec. (0 – 100 % at 90 % setpoint) Line voltage effect: ±0.1 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @1 minute (input to output to power to ground)

MODEL: AS4V AS4V SPECIFICATIONS ES-1609 Rev.20 Page 3/5 https://www.m-system.co.jp/ STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 Low Voltage Directive EN 61010-1 Measurement Category II (output) Installation Category II (power) Pollution Degree 2 Input to output to power: Basic insulation (300 V) RoHS Directive Approval: UL/C-UL general safety requirements (UL 61010-1, CAN/CSA-C22.2 No.61010-1) EXTERNAL VIEW ALARM DATA ITEM DATAITEM ITEM No. Display DATA UP-DOWN Keys ITEM No. UP-DOWN Keys *Monitor LEDs DATA Display *L3 or L4 does not turn on for dual output type. Refer to the instruction manual for detailed procedures. EXTERNAL DIMENSIONS unit: mm [inch] 80 (3.15) 132 (5.20) (.79)

  • When mounting, no extra space is needed between units. 5678 2111 10 [3.3 (.13)] 80 (3.15) 40 (1 .57) 50 (1 .97) 7 .8 (.31) CLAMP (top & bottom) DIN RAIL 35mm wide2–4.5 (.18) dia. MTG HOLE 25 (.98) deep 11 –M3.5 SCREW

MODEL: AS4V AS4V SPECIFICATIONS ES-1609 Rev.20 Page 4/5 https://www.m-system.co.jp/ TERMINAL ASSIGNMENTS unit: mm (inch) 2111 10 12 (.47) INPUT RESISTOR (model: REM) Input shunt resistor attached for current input. SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM LOAD Inductive Load (Coil) Varistor or Spark Quenching Circuit

  • DC Powered LOAD Inductive Load (Coil) Diode, Varistor or CR Circuit ■ Relay Protection
  • AC Powered U Ry Ry Ry Ry Ry Ry Base Socket U(+) V(–) POWER Digital Computation Circuit *INPUT

5 Low Drift

*Input shunt resistor attached for current input. L2 OUTPUT L1 OUTPUT N.C. N.O. COM N.C. N.O. COM L1 L2 DATA ITEM

  • SPDT Relay Output n OUTPUT CODE: 5, 5A Base Socket U(+) V(–) POWER Digital Computation Circuit *INPUT

*Input shunt resistor attached for current input. L4 OUTPUT L1 OUTPUT COM L3 OUTPUT L2 OUTPUT COM L1 L3 DATA ITEM

  • N.O. Relay Output L2 L4 n OUTPUT CODE: 2, 2A
  • N.C. Relay Output n OUTPUT CODE: 3, 3A L4 OUTPUT L1 OUTPUT COM L3 OUTPUT L2 OUTPUT COM

MODEL: AS4V AS4V SPECIFICATIONS ES-1609 Rev.20 Page 5/5 https://www.m-system.co.jp/ Specifications are subject to change without notice.