DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
THIS CATALOG PAGE IS FOR REFERENCE ONLY. REQUEST A CERTIFIED UMPCO DRAWING FOR ACTUAL SPECIFICATIONS. ANY CONFLICT BETWEEN THIS DOCUMENT AND THE CERTIFIED DRAWING, THE CERTIFIED DRAWING WILL TAKE PRESIDENCE. IF THE DOCUMENT IS CONTROLLED BY ANY OTHER SOURCE THAN UMPCO, THE CERTIFIED DRAWING MUST BE PURCHASED THROUGH THAT ORGANIZATION. UMPCO, INC CAGE CODE No. 18076 REV N/C 01/29/09 AS21919 CLAMP, LOOP CUSHIONED PART NUMBER 7100 LAMPSON AVE * PO BOX 5158 * GARDEN GROVE, CA 92846-5158 SALES: (714) 897-3531 * BUS: (714) 897-3536 * FAX: (714) 897-2611 .228/.218 DIA HOLE THRU .360/. 390R (TYP) .500 R Ǿ D WEDGE /8/ G T VIEW A-A .219 E CUSHION S 2 X .225 MIN .045 MIN BAND JOGGLE R.06 MIN STIFFENING BEAD TO EXTEND TO CENTERLINE /5/ 110°/85° ENLARGED ACCEPTABLE WEDGE CONFIGURATION B RAD MIN VIEW B CLAMP CENTERLINE 01 /8/ /8/ 02 - 03 0.046 0.110 04 - 08 09 - 10 11 - 17 18 - 30 0.094 0.125 31 - 48 50 - 66 /8/ /8/ 0.109 0.125 0.040 0.060 TABLE 2 - DIMENSIONS 0.093 0.155 0.125 0.312 0.062 0.125 0.078 0.156 0.062 S +.020 -.000 R ±.016G MAXG MINB MAXB MIN DASH NO RANGE /16/ 2X R .09 R .09 .05 VIEW B-B B B B B A A B B
THIS CATALOG PAGE IS FOR REFERENCE ONLY. REQUEST A CERTIFIED UMPCO DRAWING FOR ACTUAL SPECIFICATIONS. ANY CONFLICT BETWEEN THIS DOCUMENT AND THE CERTIFIED DRAWING, THE CERTIFIED DRAWING WILL TAKE PRESIDENCE. IF THE DOCUMENT IS CONTROLLED BY ANY OTHER SOURCE THAN UMPCO, THE CERTIFIED DRAWING MUST BE PURCHASED THROUGH THAT ORGANIZATION. UMPCO, INC CAGE CODE No. 18076 REV N/C 01/29/09 AS21919 CLAMP, LOOP CUSHIONED PART NUMBER 7100 LAMPSON AVE * PO BOX 5158 * GARDEN GROVE, CA 92846-5158 SALES: (714) 897-3531 * BUS: (714) 897-3536 * FAX: (714) 897-2611 SIZE CODE /16/ TUBE DIA OD (REF) D ±.015 ALUM ALLOY E ±.015 ALUM ALLOY T CRES E ±.015 CRES T TABLE 1 - SIZE CODE AND DIMENSIONS
THIS CATALOG PAGE IS FOR REFERENCE ONLY. REQUEST A CERTIFIED UMPCO DRAWING FOR ACTUAL SPECIFICATIONS. ANY CONFLICT BETWEEN THIS DOCUMENT AND THE CERTIFIED DRAWING, THE CERTIFIED DRAWING WILL TAKE PRESIDENCE. IF THE DOCUMENT IS CONTROLLED BY ANY OTHER SOURCE THAN UMPCO, THE CERTIFIED DRAWING MUST BE PURCHASED THROUGH THAT ORGANIZATION. UMPCO, INC CAGE CODE No. 18076 REV N/C 01/29/09 AS21919 CLAMP, LOOP CUSHIONED PART NUMBER 7100 LAMPSON AVE * PO BOX 5158 * GARDEN GROVE, CA 92846-5158 SALES: (714) 897-3531 * BUS: (714) 897-3536 * FAX: (714) 897-2611 NOTES: 1. MATERIAL: BAND: a. CODE LETTER C - TYPE 321 CORROSION RESISTANT STEEL PER AMS 5510 b. CODE LETTER D - 2024-0 ALUMINUM ALLOY PER AMS-QQ-A-250/5 CUSHION: a. CODE LETTER E - ETHYLENE PROPYLENE PER MIL-C-85052/2 b. CODE LETTER F - NITRILE PER MIL-C-85052/1 c. CODE LETTER G - CHLOROPRENE PER AMS 3209 AND OZONE RESISTANCE REQUIREMENTS PER NOTE 11 d. CODE LETTER H - SILICONE PER AMS 3310 e. CODE LETTER J - FLUOROSILICONE PER MIL-R-25988, TYPE II, CLASS 1, GRADE 60 2. HEAT TREATMENT: a. CODE LETTER D - HEAT TREAT TO T42 TEMPER IN ACCORDANCE WITH AMS-H-6088 3. FINISH: a. CODE LETTER C - PASSIVATE PER AMS-QQ-P-35 b. CODE LETTER D - CHEMICAL CONVERSION COATING PER MIL-C-5541, CLASS 1A /4/ MATERIAL COMBINATION CODES: LETTERS INDICATE BAND AND CUSHION MATERIAL CODES. DO NOT SPECIFY BAND/CUSHION COMBINATIONS NOT LISTED. MAXIMUM RECOMMENDED TEMPERATURE IS INDICATED IN PARENTHESIS. a. DE = ALUMINUM ALLOY BAND WITH ETHYLENE PROPYLENE CUSHION (212 °F) b. DF = ALUMINUM ALLOY BAND WITH NITRILE CUSHION (275 °F) c. DG = ALUMINUM ALLOY BAND WITH CHLOROPRENE CUSHION (212 °F) d. CE = CRES BAND WITH ETHYLENE PROPYLENE CUSHION (275 °F) e. CF = CRES BAND WITH NITRILE CUSHION (275 °F) f. CG = CRES BAND WITH CHLOROPRENE CUSHION (212 °F) g. CH = CRES BAND WITH SILICONE CUSHION (400 °F) h. CJ = CRES BAND WITH FLUOROSILICONE CUSHION (392 °F) /5/ STIFFENING BEAD SHALL BE REQUIRED ON SIZE -06 THRU -24. ALL RADII ON THE STIFFENING BEAD SHALL BE SMOOTH AND BLEND. NO SHARP TOOL MARKS ARE ALLOWED. 6. IDENTIFICATION: MARK PART NUMBER AND MANUFACTURER’S NAME, TRADEMARK OR CAGE CODE PER AS478-2A1. DO NOT MARK IN RADIUS. 7. CUSHION APPLICATION AND COLOR INFORMATION: a. CODE LETTER E - FOR USE IN AREAS EXPOSED TO PHOSPHATE ESTER HYDRAULIC FLUID. EXCELLENT OZONE RESISTANCE. NOT RESISTANT TO PETROLEUM BASED FLUIDS. COLOR SHALL BE PURPLE. b. CODE LETTER F - FOR USE PRIMARILY IN FUEL IMMERSION AND FUEL VAPORS. GOOD OZONE RESISTANCE. NOT RESISTANT TO PHOSPHATE ESTER BASED FLUIDS. NOT FOR USE ON TITANIUM TUBING. COLOR SHALL BE SOLID YELLOW. c. CODE LETTER G - FOR GENERAL PURPOSE USE IN AREAS EXPOSED TO PETROLEUM BASED HYDRAULIC FLUIDS AND OCCASIONAL FUEL SPLASH. EXCELLENT OZONE RESISTANCE. NOT RESISTANT TO PHOSPHATE ESTER BASED FLUIDS. NOT FOR USE ON TITANIUM TUBING. COLOR SHALL BE BLACK WITH A BLUE IDENTIFIER. SEE NOTE 10. d. CODE LETTER H - FOR ELEVATED TEMPERATURE USAGE IN AREAS EXPOSED TO PHOSPHATE ESTER BASED FLUID AND OTHER SYNTHETIC FLUIDS. UNAFFECTED BY OZONE. NOT RESISTANT TO PETROLEUM BASED FLUIDS. COLOR SHALL BE NATURAL WHITE. e. CODE L ETTER J - FOR ELEVATED TEMPERATURE USAGE IN AREAS EXPOSED TO PETROLEUM BASED FLUIDS. UNAFFECTED BY OZONE. NOT RESISTANT TO PHOSPHASE ESTER BASED FLUIDS. COLOR SHALL BE SOLID BLUE. /8/ CODE LETTER “W” INDICATES WEDGE TYPE CUSHION. WEDGE IS MANDATORY FOR -02 THRU -48 SIZE CLAMPS. WEDGE IS PROHIBITED ON -01 AND -50 THRU -66 SIZE CLAMPS. WEDGE SHALL BE INTERGRALLY MOLDED TO CUSHION OR VULCANIZED USING PRESSURE AND HEAT TO ACCOMPLISH A BOND BETWEEN CUSHION AND WEDGE. WEDGE SHALL OVERLAP AND TOUCH OPPOSITE END OF CUSHION WHEN CLAMP MOUNTING HOLES ARE ALIGNED AND DIMENSION G IS 0.00 (CLAMP COMPLETELY CLOSED). 9. CLOSURE TEST: THE CLAMP SHALL BE INSTALLED ON A BAR HAVING A DIAMETER EQUAL TO THE NOMINAL D DIMENSION WITHIN ± .001. DIMENSION G (GAP) SHALL BE RESTRAINED WITHIN THE SPECIFIED TOLERANCE LIMITS AND THE HOLES SHALL BE IN ALIGNMENT WITHIN .010. THE BAND WIDTH STRAIGHTNESS (PARALLEL TO THE BAR AXIS) SHALL BE WITHIN .010 EXCEPT IN THE AREA OF THE STIFFENING BEAD.
THIS CATALOG PAGE IS FOR REFERENCE ONLY. REQUEST A CERTIFIED UMPCO DRAWING FOR ACTUAL SPECIFICATIONS. ANY CONFLICT BETWEEN THIS DOCUMENT AND THE CERTIFIED DRAWING, THE CERTIFIED DRAWING WILL TAKE PRESIDENCE. IF THE DOCUMENT IS CONTROLLED BY ANY OTHER SOURCE THAN UMPCO, THE CERTIFIED DRAWING MUST BE PURCHASED THROUGH THAT ORGANIZATION. UMPCO, INC CAGE CODE No. 18076 REV N/C 01/29/09 AS21919 CLAMP, LOOP CUSHIONED PART NUMBER 7100 LAMPSON AVE * PO BOX 5158 * GARDEN GROVE, CA 92846-5158 SALES: (714) 897-3531 * BUS: (714) 897-3536 * FAX: (714) 897-2611 TABLE 3 UNSTRAINED SPECIMEN THICKNESS EXPOSURE TIME .041 IN TO .050 IN 2 H 50 MIN .051 IN TO .060 IN 3 H 30 MIN .061 IN TO .070 IN 4 H 10 MIN .071 IN TO .080 IN 4 H 50 MIN /10/ EXTRUDED MATERIAL SHALL BE IDENTIFIED BY A BLUE STRIPE EXTENDING LENGTHWISE ALONG BOTH EDGES OF THE CUSHION. THE STRIPE WIDTH SHALL BE EQUAL TO THE WIDTH OF THE CUSHION EDGE. MOLDED MATERIAL SHALL BE IDENTIFIED BY A BLUE AREA AT THE WEDGE END. THE BLUE AREA SHALL BE ON ONE OR BOTH EDGES OF THE CUSHION AND MAY INCLUDE THE WEDGE AND SHALL HAVE A MINIMUM LENGTH OF .125 In TO A MAXIMUM OF .750 in. THE BLUE AREA SHALL BE LOCATED WITHIN AN AREA NOT TO EXCEED 1.50 in OR 50% OF THE TOTAL CUSHION LENGTH, WHICHEVER IS SMALLER, WHEN MEASURED FROM THE WEDGE END. IN NO CASE SHALL THE BLUE AREA EXTEND BEYOND 50% OF THE CUSHION LENGTH. THE MATERIAL USED FOR THE BLUE IDENTIFIER SHALL BE THE SAME AS THE CUSHION MATERIAL EXCEPT COLOR BLUE. INKING OR OTHER SURFACE COLORING METHODS SHALL NOT BE USED. /11/ CHLOROPRENE RUBBER MATERIAL SHALL BE SUBJECTED TO THE OZONE RESISTANCE AS FOLLOWS: a. THE TEST SPECIMEN SHALL BE CUT FROM AN ACTUAL CLAMP CUSHION. IF THE PARTICULAR CLAMP CUSHION IS NOT SUFFICIENTLY LONG TO OBTAIN THE SPECIMEN, A LONGER SECTION MAY BE USED AS LONG AS IT IS VERIFIED THAT THE LONGER SECTION COMES FROM THE SAME LOT AND CURE AS THE SHORT CUSHION SECTION. b. THE TEST SPECIMEN SHALL BE CONDITIONED BY EXPOSURE TO DRY AIR AT A TEMPERATURE OF 212 °F ± 5 °F FOR A PERIOD OF 70 h. c. THE TEST SPECIMEN SHALL BE CUT PARALLEL TO THE LONGITUDINAL DIRECTION OF THE CLAMP CUSHION. THE SPECIMEN SHALL BE A DUMBBELL SHAPE AND SHALL HAVE A REDUCED SECTION WIDTH d. THE INITIAL THICKNESS OF THE SPECIMENS SHALL BE MEASURED AND RECORDED. MOUNT THE SPECIMENS IN A SUITABLE FIXTURE AND LONGITUDINALLY STRAIN TO 70% ± 3%. THE FIXTURE HOLDING THE STRAINED TEST SPECIMENS SHALL BE PLACED IN A TEST CHAMBER HAVING AN OZONE CONCENTRATION OF 600 ± 30 PARTS PER HUNDRED MILLION AND A TEMPERATURE OF 125 °F ± 5 °F. THE OZONE GENERATION AND MEASUREMENT TECHNIQUE SHALL BE IN ACCORDANCE WITH ASTM D 1149. THE DURATION OF THE TEST FOR VARIOUS THICKNESS SHALL BE AS FOLLOWS: NOTES (Continued): e. CRITERIA FOR CONFORMANCE TO THE CHLOROPRENE OZONE RESISTANCE TEST IS THE ABILITY OF THE STRAINED SPECIMEN TO MEET THE REQUIREMENTS OF THE TEST WITHOUT COMPLETE BREAKAGE. SURFACE DETERIORATION OR SEVERE CRACK PROPAGATION WITHOUT COMPLETE BREAKAGE SHALL NOT BE CAUSE FOR FAILURE. 12. REMOVE BURRS AND SHARP EDGES. 13. DIMENSIONING AND TOLERANCING: ASME Y14.5M-1994. 15. INTENDED USE: THESE CLAMPS ARE INTENDED FOR GENERAL PURPOSE CLAMPING APPLICATIONS INCLUDING ELECTRICAL WIRE BUNDLE CLAMPING. FOR HIGH PERFORMANCE LOOP STYLE CLAMPS FOR USE IN MIL-H-5540 HYDRAULIC SYSTEMS SEE MIL-C-85052. /16/ EXAMPLE OF PART NUMBER: COPYRIGHT SAE AS21919 W DG 08 SIZE CODE (FROM TABLE 1) MATERIAL & CUSHION CODE LETTERS /4/ WEDGE, OMIT FOR NON-WEDGE CLAMP /8/ BASIC PART NUMBER