0.4 0.5 0.1 0.3 0.2 300kHz 1.5GHz 2.5GHz3GHz COM-NC COM-NO Insertion loss, dB Frequency Arrangement Contact Coil (at 20°C, 68°F) Contact material Max. switching voltage Isolation Max. switching current Insertion loss 10mA 24 V DC (resistive load) 10W 2.5 GHz, Impedance 50W 3·105 105 V.S.W.R.(Return loss) Min. 60 dB Max. 0.2 dB Max. 1.2 (Min. 20.8dB) Input power Max. 20W (at 40°C, 2 coil latching Single side stable 200 mW Nominal operating power 1 coil latching 400 mW 200 mW Initial contact resistance

1 Form C

Max. 100 mW Contact carrying power High frequency characteristics (~2.5GHz, Impedance 50W ) Expected life (min. operations) 5·10 Electrical Mechanical (at 180 cpm) Rating Contact rating

30 V DC

0.5 A DC

Initial insulation resistance*1 Operate time [Set time]*3 (at 20°C) Max. 10ms (Approx. 6ms) [Max. 10ms (Approx. 5ms)] Max. 6ms (Approx. 3ms) [Max. 10ms (Approx. 5ms)] Max. 60°CTemperature rise (at 20°C)*4 Initial breakdown voltage* Between open contacts Between contact and coil Between contact and earth terminal

500 Vrms

1,000 Vrms Min. 100 MW (at 500 V DC) Shock resistance Vibration resistance Unit weight Approx. 5 g .18 oz Min. 200 m/s2 {20 G} Min. 1,000 m/s2 {100 G} Functional*5 Destructive*6 Functional*7 Destructive 10 to 55 Hz at double amplitude of 3 mm 10 to 55 Hz at double amplitude of 5 mm Conditions for operation, transport and storage*8 (Not freezing and condensing at low temperature) Ambient temp. Humidity –40°C to 60°C –40°F to 140°F 5 to 85% R.H. Release time (without diode) [Reset time]*3 Max. 20W(at 40°C, 10W (2.5 GHz, Impedance 10mA 24V DC(resistive load) Remarks * Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as “Initial breakdown voltage” section. *2 Detection current: 10mA *3 Nominal operating voltage applied to the coil, excluding contact bounce time. *4 By resistive method, nominal voltage applied to the coil: Contact carrying power: *5 Half-wave pulse of sine wave: 11ms, detection time: 10ms. *6 Half-wave pulse of sine wave: 6ms *7 Detection time: 10ms *8 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 61) 10RXAEx. Contact arrangement 1: 1 Form C Product name RX Note: Standard packing; Carton: 50 pcs. Case 500 pcs. 0: Single side stable 1: 1 coil latching 2: 2 coil latching 03: 3 4H: 4.5 06: 6 09: 9 12: 12 24: 24 Operating function Coil voltage, V DC 1. Excellent high frequency character- istics (~2.5GHz, Impedance 50 W

  • Insertion loss: 0.2 dB or less
  • Isolation: 60 dB or more 20.8dB or more 2. High sensitivity
  • Nominal operating power: 200 mW 3. Small size
  • Size: 20.5(L) 12.4(W) 9.4(H) mm .807(L) .488(W) .370(H) inch *Also available for unit support (contact us for more details). SMALL MICRO WAVE RELAY RX-RELAYS 20.5 .807 9.4 .370 12.4 .488 TYPICAL APPLICATIONS
  • Cellular phone base station (W-CDMA, FPLMTS, IMT -2000, PCS, DCS)
  • Cellular phone-related measurement devices (SP3T/SP4T switches, etc)
  • Wireless LAN
  • Wireless Local Loop SPECIFICATIONS mm inch
  • Insertion loss

ORDERING INFORMATION

Part No. ARX1003 ARX104H ARX1006 ARX1009 ARX1012 ARX1024 ARX1103 ARX114H ARX1106 ARX1109 ARX1112 ARX1124 ARX1203 ARX124H ARX1206 ARX1209 ARX1212 ARX1224 3 2.25 0.3 45 66.7 200 3.3 6 4.5 0.6 180 33.3 200 6.6 9 6.75 0.9 405 22.2 200 9.9 24 18 2.4 2,880 8.3 200 26.4 12 9 1.2 720 16.7 45 66.7 101 44.4 180 33.3 405 22.2 2,880 8.3 720 22.5 50.6 202.5 1,440 360 16.7 133.3 88.9 66.7 44.4 16.7 33.3 200 200 200 200 200 200 200 400 400 400 400 400 400 13.2 Nominal voltage, V DC Pick-up voltage, V DC (max.)(initial) Drop-out voltage, V DC (min.)(initial) Nominal voltage, V DC Set voltage, V DC (max.)(initial) Reset voltage, V DC (max.)(initial) Coil resistance, W (–10%) Nominal operating current, mA (–10%) Nominal operating power, mW Max. allowable voltage, V DC Max. allowable voltage, V DC

  • Single side stable type Part No. 3 2.25 3.3 4.5 3.375 4.95 6 4.5 6.6 9 6.75 9.9 24 18 26.4 12 9 13.2 Coil resistance, W (–10%) Nominal operating current, mA (–10%) Nominal operating power, mW Nominal voltage, V DC Set voltage, V DC (max.)(initial) Reset voltage, V DC (max.)(initial) Max. allowable voltage, V DCPart No. Coil resistance, W (–10%) Nominal operating current, mA (–10%) Nominal operating power, mW
  • 1 coil latching type 3 2.25 3.3 4.5 3.375 4.95 6 4.5 6.6 9 6.75 9.9 24 18 26.4 12 9 2.25 3.375 4.5 6.75 2.25 3.375 4.5 6.75 9 13.2
  • 2 coil latching type TYPES ANE COIL DATA (at 20°C 68°F) DIMENSIONS mm inch Schematic (Bottom view) Tolerance: –0.1 –.004 General tolerance: –0.3 –.012 (Reset condition) PC board pattern (Bottom view) (Reset condition)(Deenergized condition) (2.74) (.108) (2.04) (.080) 2.54 .100 2-0.6·0.3 2-.024·.012 7-0.40 to 0.45 dia. 7-.016 to .018 dia. 2.63 .104 Solder to the PC board earth. 9.2 .362 0.2 .008 3.0 .118 20.5 .807 12.4 .488 0.9 dia hole .035 dia hole 7.62 .300 2.54 .1007.62 .300 0.90 .035 (2 coil latching type only) R 0.45 14 13 12 11 10 9 8 NC COM NO 891011121314 RESET COM SET 1 76 891011121314 RESET COM SET Single side stable 1 coil latching 2 coil latching

0.4 0.5 0.1 0.3 0.2 300kHz 1.5GHz 2.5GHz3GHz COM-NC COM-NO Insertion loss, dB Frequency 100 300kHz 1.5GHz 2.5GHz 3GHz COM-NC COM-NO Isolation, dB Frequency 300kHz 1.5GHz 2.5GHz 3GHz COM-NO 5.0 2.0 1.5 1.2 1.1 COM-NC Return loss, dB Frequency V.S.W.R. 1. High frequency characteristics Sample: ARX1012 Measuring method: Measured with HP network analyzer (HP8753C). The details for the high freqency characteristics and the measurement procedures and conditions are listed in the RX relay test report.

  • Insertion loss • Isolation • V.S.W.R. (Return loss) NOTES 1. Coil operating power Pure DC current should be applied to the coil. The wave form should be rectangu- lar. lf it includes ripple, the ripple factor should be less than 5%. However, check it with the actual circuit since the characteristics may be slightly different. The nominal operating voltage should be applied to the coil for more than 30 ms to set/reset the latching type relay. 2. Coil connection When connecting coils, refer to the wiring diagram to prevent mis-operation or mal- function. 3. External magnetic field Since RX relays are highly sensitive po- larized relays, their characteristics will be affected by a strong external magnetic field. Avoid using the relay under that condition. 4. Cleaning For automatic cleaning, the boiling meth- od is recommended. Avoid ultrasonic cleaning which subjects the relays to high frequency vibrations, which may cause the contacts to stick. lt is recommended that a fluorinated hy- drocarbon or other alcoholic solvents be used. 5. Soldering The soldering shall be performed under following condition. Max. 260°C 500°F 10s Max. 350°C 662°F 3s In addition, when soldering the case to the PC board, the plating may swell depending on the soldering conditions. For Cautions for Use, see Relay Technical Information (Page 48 to 76). 9/1/2000 All Rights Reserved, © Copyright Matsushita Electric Works, Ltd. Go To Online Catalog