GU (General Use) Type 1-Channel (Form A) Current Limit Function 4-Pin Type 3.2 .126 6.4 .252 4.78 .188 2.9 .114 6.4 .252 4.78 .188
FEATURES
- Current Limit Function To control an over current from flowing, the current limit function has been real- ized. It keeps an output current at a con- stant value when the current reaches a specified current limit value. 2. Enhancing the capability of surge re- sistance between output terminals The current limit function controls the ON time surge current to enhance the capa- bility of surge resistance between output terminals. 3. Reinforced insulation 5,000 V type More than 0.4 mm internal insulation dis- tance between inputs and outputs. Con- forms to EN41003, EN60950 (reinforced insulation). 4. Compact 4-pin DIP size The device comes in a compact (W)6.4 (L)4.78 (H) 3.2mm (W).252 (L).188 (H).126inch, 4-pin DIP size 5. Controls low-level analog signals PhotoMOS relays feature extremely low closed-circuit offset voltage to enable control of low-level analog signals without distortion. 6. High sensitivity, low ON resistance 7. Low-level off state leakage current TYPICAL APPLICATIONS
- Telephone equipment
- Modem TYPES *Indicate the peak AC and DC values. Note: For space reasons, the initial letters of the product number "AQY", the SMD terminal shape indicator "A" and the package type indicator "X" and "Z" are omitted from the seal. Type I/O isolation voltage Output rating* Part No. Packing quantityThrough hole terminal Surface-mount terminal Load voltage Load current Tube packing style Tape and reel packing style Tube Tape and reelPicked from the 1/2-pin side Picked from the 3/4-pin side AC/DC type Reinforced 5,000 V 350 V 120 mA AQY210HL AQY210HLA AQY210HLAX AQY210HLAZ 1 tube contains 100 pcs. 1 batch contains 1,000 pcs. 1,000 pcs. RATING 1. Absolute maximum ratings (Ambient temperature: 25 C 77 Item Symbol AQY210HL(A) Remarks Input LED forward current I F 50 mA LED reverse voltage V R 3 V Peak forward current I FP 1 A f = 100 Hz, Duty factor = 0.1% Power dissipation P in 75 mW Output Load voltage (peak AC) V L 350 V Continuous load current I L 0.12 A Power dissipation P out 500 mW Total power dissipation P T 550 mW I/O isolatiom voltage V iso 5,000 V AC Temperature limits Operating T opr –40 C to +85 C –40 F to +185 F Non-condensing at low temperatures Storage T stg –40 C to +100 C –40 F to +212 F mm inch TESTING
- Electrical characteristics (Ambient temperature: 25 C 77 Note: Recommendable LED forward current I F = 5 to 10 mA. For type of connection, see page 31. *Turn on/Turn off time Item Symbol AQY210HL(A) Condition Input LED operate current Typical I Fon 1.2 mA I L = Max.Maximum 3.0 mA LED turn off current Minimum I Foff 0.4 mA I L = Max.Typical 1.1 mA LED dropout voltage Minimum V F 1.14 (1.25 V at I F = 50mA) I F = 5 mATypical 1.5 V Output On resistance Typical R on W I F = 5 mA I L = Max. Within 1 s on timeMaximum 25 W Off state leak- age current Maximum I Leak m A I F = 0 V L = Max. Current limit Typical — 0.18 A I F = 5 mA Transfer char- acteristics Turn on time* Typical T on 0.5 ms I F = 5 mA I L = Max.Maximum 2.0 ms Turn off time*Typical T off 0.08 ms I F = 5 mA I L = Max.Maximum 1.0 ms I/O capacitanceTypical C iso 0.8 pF f = 1 MHz V B = 0Maximum 1.5 pF Initial I/O isola- tion resistanceMinimum R iso 1,000 M W
500 V DC
Output 10% 90% Toff REFERENCE DATA 1. Load current vs. ambient temperature char- acteristics Allowable ambient temperature: –40 C to +85 C –40 F to +185 F 2. On resistance vs. ambient temperature char- acteristics Measured portion: between terminals 3 and 4; LED current: 5 mA; Load voltage: Max. (DC) Continuous load current: Max.(DC) 3. Turn on time vs. ambient temperature char- acteristics LED current: 5 mA; Load voltage: Max.(DC); Continuous load current: Max.(DC) Ambient temperature, °C Load current, mA 200 150 100 02 0 4 06 0 80 85100–20–40 On resistance, W Ambient temperature, °C –40 –20 02 0 4 0 6 0 80 85 Ambient temperature, °C Turn on time, ms 0.5 1.5 –40 –20 2.5 02 0 4 0 6 0 80 85 n For Dimensions, see Page 27. n For Schematic and Wiring Diagrams, see Page 31. n For Cautions for Use, see Page 36.
- Turn off time vs. ambient temperature char- acteristics LED current: 5 mA; Load voltage: Max.(DC); Continuous load current: Max.(DC) 5. LED operate current vs. ambient tempera- ture characteristics Load voltage: Max.(DC); Continuous load current: Max.(DC) 6. LED turn off current vs. ambient temperature characteristics Load voltage: Max.(DC); Continuous load current: Max.(DC) Ambient temperature, °C Turn off time, ms 0.05 0.1 0.15 0.2 –40 –20 0.25 02 0 4 06 0 80 85 Ambient temperature, °C LED operate current, mA –40 –20 02 0 4 0 6 0 80 85 Ambient temperature, °C LED turn off current, mA –40 –20 02 0 4 0 6 0 80 85 7. LED dropout voltage vs. ambient tempera- ture characteristics LED current: 5 to 50 mA 8. Voltage vs. current characteristics of output at MOS portion Measured portion: between terminals 3 and 4; Ambient temperature: 25 C 77 F 9. Off state leakage current Measured portion: between terminals 3 and 4; Ambient temperature: 25 C 77 F 0–40 –20 20 40 60 80 85 Ambient temperature, °C LED dropout voltage, V 1.5 1.4 1.3 1.2 1.1 1.0 50mA 30mA 20mA 10mA 5mA 531 –5 –3 140 120 –20 –40 –60 –80 –100 –120 –140 100 –2–4 Voltage, V Current, mA Load voltage, V Off state leakage current, A 0 60 100 10–3 10–6 10–9 10–12 20 40 80 10. LED forward current vs. turn on time char- acteristics Measured portion: between terminals 3 and 4; Load voltage: Max.(DC); Continuous load current: Max.(DC); Ambient temperature: 25 C 77 F 11. LED forward current vs. turn off time char- acteristics Measured portion: between terminals 3 and 4; Load voltage: Max.(DC); Continuous load current: Max.(DC); Ambient temperature: 25 C 77 F 12. Applied voltage vs. output capacitance characteristics Measured portion: between terminals 3 and 4; Frequency: 1 MHz; Ambient temperature: 25 C 77 F LED forward current, mA Turn on time, ms 0.5 1.5 2.5 1002 0 3 0 4 0 50 60 LED forward current, mA Turn off time, ms 0.05 0.1 1002 0 3 0 4 0 0.2 50 60 0.15 Applied voltage, V Output capacitance, pF 10 20 30 40 500 What is current limit When a load current reaches the speci- fied output control current, a current limit function works against the load current to keep the current a constant value. The current limit circuit built into the Pho- toMOS relay thus controls the instanta- neous load current to effectively ensure circuit safety. This safety feature protects circuits down- stream of the PhotoMOS relay against over-current. But, if the current-limiting feature is used longer than the specified time, the Photo- MOS relay can be destroyed. Therefore, set the output loss to the max. rate or less.