AQW210HL NAIS | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 3
Technical content
GU (General Use) Type 2-Channel (Form A) Current Limit Function Type 3.2 .126 6.4 .252 9.86 .388 2.9 .114 6.4 .252 9.86 .388
FEATURES
- Current Limit Function To control an over current from flowing, the current limit function has been real- ized. It keeps an output current at a con- stant value when the current reaches a specified current limit value. 2. Enhancing the capability of surge re- sistance between output terminals The current limit function controls the ON time surge current to enhance the capa- bility of surge resistance between output terminals. 3. Reinforced insulation 5,000 V type More than 0.4 mm internal insulation dis- tance between inputs and outputs. Con- forms to EN41003, EN60950 (reinforced insulation). 4. Compact 8-pin DIP size The device comes in a compact (W)6.4 (L)9.86 (H) 3.2mm (W).252 (L).388 (H).126inch, 8-pin DIP size (through hole terminal type) 5. Applicable for 2 Form A use as well as two independent 1 Form A use. 6. Controls low-level analog signals 7. High sensitivity, high speed re- sponse. Can control a maximum 0.12 A load cur- rent with a 5 mA input current. Fast oper- ation speed of 0.5ms (typ.) 8. Low-level off state leakage current TYPICAL APPLICATIONS
- Telephone equipment
- Modem TYPES *Indicate the peak AC and DC values. Note: For space reasons, the SMD terminal shape indicator "A" and the package type indicator "X" and "Z" are omitted from the seal. Type I/O isolation voltage Output rating* Part No. Packing quantityThrough hole terminal Surface-mount terminal Load voltage Load current Tube packing style Tape and reel packing style Tube Tape and reelPicked from the 1/2/3/4-pin side Picked from the 5/6/7/8-pin side AC/DC type Reinforced 5,000 V AC 350 V 120 mA AQW210HL AQW210HLA AQW210HLAX AQW210HLAZ 1 tube contains 40 pcs. 1 batch contains 400 pcs. 1,000 pcs. RATING 1. Absolute maximum ratings (Ambient temperature: 25 C 77 Item Symbol AQW210HL(A) Remarks Input LED forward current I F 50 mA LED reverse voltage V R 3 V Peak forward current I FP 1 A f = 100 Hz, Duty factor = 0.1% Power dissipation P in 75 mW Output Load voltage (peak AC) V L 350 V Continuous load current I L 0.1 A (0.12 A) ( ): in case of using only 1 channel Peak AC, DC Power dissipation P out 800 mW Total power dissipation P T 850 mW I/O isolatiom voltage V iso 5,000 V AC Temperature limits Operating T opr –40 C to +85 C –40 F to +185 F Non-condensing at low temperatures Storage T stg –40 C to +100 C –40 F to +212 F mm inch TESTING
- Electrical characteristics (Ambient temperature: 25 C 77 Note: Recommendable LED forward current I F = 5 to 10 mA. For type of connection, see page 32. *Turn on/Turn off time Item Symbol AQW210HL(A) Condition Input LED operate current Typical I Fon 1.2 mA I L = Max.Maximum 3.0 mA LED turn off current Minimum I Foff 0.4 mA I L = Max.Typical 1.1 mA LED dropout voltage Minimum V F 1.14 (1.25 V at I F = 50mA) I F = 5 mATypical 1.5 V Output On resistance Typical R on W I F = 5 mA I L = Max. Within 1 s on timeMaximum 25 W Off state leak- age current Maximum I Leak m A I F = 0 V L = Max. Current limit Typical — 0.18 A I F = 5 mA Transfer characteristics Turn on time* Typical T on 0.5 ms I F = 5 mA I L = Max.Maximum 2.0 ms Turn off time* Typical T off 0.08 ms I F = 5 mA I L = Max.Maximum 1.0 ms I/O capacitance Typical C iso 0.8 pF f = 1 MHz V B = 0Maximum 1.5 pF Initial I/O isola- tion resistance Minimum R iso 1,000 M W
500 V DC
Output 10% 90% Toff REFERENCE DATA 1. Load current vs. ambient temperature char- acteristics Allowable ambient temperature: –40 C to +85 C –40 F to +185 F 2. On resistance vs. ambient temperature char- acteristics Measured portion: between terminals 5 and 6, 7 and 8; LED current: 5 mA; Load voltage: Max. (DC) Continuous load current: Max.(DC) 3. Turn on time vs. ambient temperature char- acteristics LED current: 5 mA; Load voltage: Max.(DC); Continuous load current: Max.(DC) Load current, mA Ambient temperature, °C 200 150 100 02 0 4 0 6 0 80 85 100–20–40 On resistance, Ω Ambient temperature, °C –40 –20 02 0 4 0 6 0 80 85 Turn on time, ms Ambient temperature, °C 0.5 1.5 –20–40 2.5 02 0 4 0 6 0 80 85 n For Dimensions, see Page 27. n For Schematic and Wiring Diagrams, see Page 32. n For Cautions for Use, see Page 36.
- Turn off time vs. ambient temperature char- acteristics LED current: 5 mA; Load voltage: Max.(DC); Continuous load current: Max.(DC) 5. LED operate current vs. ambient tempera- ture characteristics Load voltage: Max.(DC); Continuous load current: Max.(DC) 6. LED turn off current vs. ambient temperature characteristics Load voltage: Max.(DC); Continuous load current: Max.(DC) Turn off time, ms Ambient temperature, °C 0.05 0.1 0.15 0.2 0.3 –20–40 0.25 02 0 4 0 6 0 80 85 LED operate current, mA Ambient temperature, °C –20–40 02 0 4 0 6 0 80 85 LED turn off current, mA Ambient temperature, °C –40 –20 02 0 4 0 6 0 80 85 7. LED dropout voltage vs. ambient tempera- ture characteristics LED current: 5 to 50 mA 8. Voltage vs. current characteristics of output at MOS portion Measured portion: between terminals 5 and 6, 7 and 8; Ambient temperature: 25 C 77 F 9. Off state leakage current Measured portion: between terminals 5 and 6, 7 and 8; Ambient temperature: 25 C 77 F 0–40 –20 20 40 60 80 85 LED dropout voltage, V Ambient temperature, °C 1.5 1.4 1.3 1.2 1.1 1.0 50mA 30mA 20mA 10mA 5mA 531 –5 –3 140 120 –20 –40 –60 –80 –100 –120 –140 100 –2–4 Voltage, V Current, mA Off state leakage current, A Load voltage, V –12 0 60 10020 40 80 10. LED forward current vs. turn on time char- acteristics Measured portion: between terminals 5 and 6, 7 and 8; Load voltage: Max.(DC); Continuous load current: Max.(DC); Ambient temperature: 25 C 77 F 11. LED forward current vs. turn off time char- acteristics Measured portion: between terminals 5 and 6, 7 and 8; Load voltage: Max.(DC); Continuous load current: Max.(DC); Ambient temperature: 25 C 77 F 12. Applied voltage vs. output capacitance characteristics Measured portion: between terminals 5 and 6, 7 and 8; Frequency: 1 MHz; Ambient temperature: 25 C 77 F Turn on time, ms LED forward current, mA 0.5 1.5 2.5 10 20 30 40 50 60 Turn off time, ms LED forward current, mA 0.05 0.1 1002 0 3 0 4 0 0.2 50 60 0.15 Output capacitance, pF Applied voltage, V 10 20 30 40 500 What is current limit When a load current reaches the speci- fied output control current, a current limit function works against the load current to keep the current a constant value. The current limit circuit built into the Pho- toMOS relay thus controls the instanta- neous load current to effectively ensure circuit safety. This safety feature protects circuits down- stream of the PhotoMOS relay against over-current. But, if the current-limiting feature is used longer than the specified time, the Photo- MOS relay can be destroyed. Therefore, set the output loss to the max. rate or less.
- Comparison of output voltage and output current characteristics V-I Characteristics Output current Output voltage 5/7/2001 All Rights Reserved, © Copyright Matsushita Electric Works, Ltd. Go To Online Catalog