VER : PA_1 update : 2012.03.09 AC-DC Switching Power Supply AQF600 SERIES 600 Watts http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -1- ELECTRICAL SPECIFICATIONS Model No. AQF600-12S AQF600-24S AQF600-28S AQF600-36S AQF600-48S AQF600-54S Max Output Wattage (Convection) (W) 480W 600W 600W 600W 600W 600W Voltage 90-264 VAC or 120-370 VDC Frequency (Hz) 47-63 Hz Current (Full load) < 0.8 A max. (115 VAC) / < 4.0 A max. (230 VAC) Inrush Current (<2ms) < 30 A max. (115 VAC) / < 60 A max. (230 VAC) Leakage Current < 3.5 mA max.(240VAC 63Hz) Input Power Factor PF>0.98 (115 VAC) / PF>0.93 (230 VAC) at Full Load Voltage (V.DC.) 12V 24V 28V 36V 48V 54V Trim ±5% Voltage Accuracy ±2% Current (Convection) (A) max 40 25 21.4 16.6 12.5 11.1 Line Regulation (LL-HL) (typ.) ±1% Load Regulation (5-100%) (typ.) ±1% Minimum Load 5% Maximum Capacitive Load 70,000 uF 60,000 uF 48,000 uF 30,000 uF 20,000 uF 10,000 uF Ripple & Noise (max.) < 1% Efficiency (typ.) 90% 91% 92% 92% 93% 93% Hold-up Time 12 ms min. Output Switching Frequency 100 kHz Over Power Protection Auto recovery Over Voltage Protection Auto recovery Over Temperature Auto recovery Protection Short Circuit Protection Auto-recovery Input-Output (V.AC) 3000V Input-FG (V.AC) 1500V Isolation Output-FG . (V.AC) 500V 5V Stand by (18CFM FAN) 5VSB: 5V@0.6A ; Tolerance ±10% , Ripple & Noise: 100m Vp-p (max.) DC OK Signal Turn ON: 4~6V ; Turn OFF: 0~1V Remote Control +RC / -RC: Power ON=open ; Power OFF=short Function FAN Control 12VDC / 0.5A max. Operating Temperature -25°C…+70°C (with derating) Storage Temperature -25°C…+85°C Temperature Coefficient ±0.03%/°C ( 0~50°C ) Humidity 95% RH MTBF >120,000 h @ 25°C (MIL-HDBK-217F) Environment Vibration 10~500Hz, 2G 10min./1cycle, 60min. each along X, Y , Z axes. KEY FEATURES Universal Input: 90-264 VAC With P.F.C. Function, PF>0.95 Remote Sense Function Remote ON/OFF Function Current Share Function Power Good Function Protections: Over Load / Over Voltage / Over Temperature / S h o r t C i r c u i t A l l b y A u t o - r e c o v e r y High Power Density RoHS Compliant Design 3-Years Product Warranty 1. All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated. 2. Ripple & Noise are measured at 20MHz of bandwidth with 0.1uF & 47uF parallel capacitor.
VER : PA_1 update : 2012.03.09 AC-DC Switching Power Supply AQF600 SERIES 600 Watts http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -2- ELECTRICAL SPECIFICATIONS Model No. AQF600-12S AQF600-24S AQF600-28S AQF600-36S AQF600-48S AQF600-54S Weight 1200 g Physical Cooling Convection Cooled Safety Agency Approvals CE, UL60950 (Pending) EMI (Conducted & Radiated Emission) EN 55022 class B, Radiated Class A (Pending) EMC EMS (Noise Immunity) EN 55024 (Pending) BLOCK DIAGRAM DERATING 1. All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated. 2. Ripple & Noise are measured at 20MHz of bandwidth with 0.1uF & 47uF parallel capacitor.
VER : PA_1 update : 2012.03.09 AC-DC Switching Power Supply AQF600 SERIES 600 Watts http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -3- MECHANICAL DIMENSION AC Input Terminal Pin PIN# SINGLE
1 AC IN
PIN# SINGLE 2~4 +DC OUT 5~7 -DC OUT Connector Pin (CN4) PIN# SINGLE C1 +S C2 -S C3 +RC C4 -RC C5 +PG C6 GND C7 +5V SB C8 -5V SB C9 N.C C10 CS ASSEMBLY INSTRUCTIONS *U Case T=2.0mm Customer screws into the length of the case no higher than 0.5mm (Namely screw length for load plate thickness plus 2.5mm
VER : PA_1 update : 2012.03.09 AC-DC Switching Power Supply AQF600 SERIES 600 Watts http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -4- FUNCTION DESCRIPITON of CN4 : Pin No. Function Description C1 +S Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V. (max.) C2 -S Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V. (max.) C3 +RC Turns the output on and off by electrical or dry c ontact between pin C4 (-RC), Short: Power OFF, Open: Power ON. C4 -RC Remote control ground. C5 DC-OK DC-OK Signal is a DC output , referenced to pinC6(DC-OK GND). C6 GND This pin connects to the negative te rminal(-V). Return for DC-OK signal output. C8 -5V SB Stand by voltage output ground. C9 N.C No Pin C10 CS Current Share Function Pin FUNCTION MANUAL : 1. Remote Sense The remote sensing compensates voltage drop on the load wiring up to 0.5V. (max.) 2. DC-OK Signal Between DC-OK(pinC5) and GND(pinC6) Output Status 4~6V ON 0~1V OFF 3. Remote Control It can be turned ON/OFF by using the "Remote Control" function. Between RC+(pinC3) and RC-(pinC4) Output Status SW ON (Short) OFF SW OFF (Open) ON