VER : C_6 update : 2015.11.16 AC-DC Switching Power Supply AQF360E SERIES 360 Watts http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -1- ELECTRICAL SPECIFICATIONS All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated. Model No. AQF360E-12S AQF360E-24S AQ F360E-36S AQF360E-48S AQF360E-54S Max Output Wattage (W) 360W Voltage 90-264 VAC or 120-370 VDC Frequency (Hz) 47-63 Hz Current (Full load) < 4.0 A max. (115 VAC) / < 2.0 A max. (230 VAC) Inrush Current (<2ms) < 30 A max. (115 VAC) / < 60 A max. (230 VAC) Leakage Current < 0.3 mA max.(240VAC 63Hz) Input Power Factor PF>0.98 (115 VAC) / PF>0.93 (230 VAC) at Full Load Voltage (V.DC.) 12V 24V 36V 48V 54V Voltage Accuracy ±2% Current (Convection) (A) max 30 15 10 7.5 6.66 Line Regulation (LL-HL) (typ.) ±1% Load Regulation (5-100%) (typ.) ±1% Minimum Load 1% Maximum Capacitive Load 85000 uF 48000 uF 21000 uF 13000 uF 7000 uF Ripple & Noise (max.) 150mVp-p 200mVp-p Efficiency (typ.) 89% 91% 92% 93% 93% Hold-up Time 12 ms min. Output Switching Frequency 75 kHz Over Power Protection Auto recovery Over Voltage Protection Auto recovery Over Temperature Auto recovery Protection Short Circuit Protection Auto-recovery Input-Output (V.AC) 3000VAC or 4242VDC Input-FG (V.AC) 1500V Isolation Output-FG . (V.AC) 500V Operating Temperature -25°C…+70°C (with derating) Storage Temperature -25°C…+85°C Temperature Coefficient ±0.03%/°C ( 0~50°C ) Humidity 95% RH MTBF >120,000 h @ 25°C (MIL-HDBK-217F) Environment Vibration 10~500Hz, 2G 10min./1cycle, 60min. each along X, Y , Z axes. KEY FEATURES  Enclosed Switching Power Supply  Universal Input: 90-264 VAC  With P.F.C. Function, PF>0.95  Cooling by Built-in 12 VDC FAN  240W Convection without FAN  Protections: Over Load / Over Voltage / Over Temperature / Short Circuit .All by Auto-recovery  Leakage Current <300uA  High Power Density  High Efficiency up to 93%  RoHS Compliant Design  Ultra Compact Size: 6.8 x 3.2 x 2.1 Inches  3-Year Product Warranty Standard A Type

VER : C_6 update : 2015.11.16 AC-DC Switching Power Supply AQF360E SERIES 360 Watts http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -2- ELECTRICAL SPECIFICATIONS All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated. Model No. AQF360E-12S AQF360E-24S AQ F360E-36S AQF360E-48S AQF360E-54S Weight 729 g Physical Cooling Method Cooling by Built-in DC FAN Safety Agency Approvals CE, UL60950, CB EMI (Conducted & Radiated Emission) EN 55022 class B EMC EMS (Noise Immunity) EN 55024 NOTE 1. Ripple & Noise are measured at 20MHz of bandwidth with 0.1uF & 47uF parallel capacitor. 2. Strongly recommend to conduct this test with DC Voltage. If customer wishes to test with AC Voltage, please disconnect all Y-Capacitors within Arch power supply. BLOCK DIAGRAM DERATING

VER : C_6 update : 2015.11.16 AC-DC Switching Power Supply AQF360E SERIES 360 Watts http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -3- MECHANICAL DIMENSION ( Top View ) Standard PIN# Single 1 FG

2 AC IN (N)

3 AC IN (L)

4~6 +DC OUT 7~9 -DC OUT A Type PIN# Single 1 FG 4~9 +DC OUT 10~15 -DC OUT ASSEMBLY INSTRUCTIONS *U Case T=2.0mm Customer screws into the length of the case no higher than 0.5mm (Namely screw length for load plate thickness plus 2.5mm

VER : C_6 update : 2015.11.16 AC-DC Switching Power Supply AQF360E SERIES 360 Watts http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -4- EFFICIENCY VERSUS LOAD AQF360E-12S VIN VS Efficiency LOAD VS Efficiency Input Voltage (V) 90 115 180 230 264 Load (%) 0 10 20 30 40 50 Load (%) 60 70 80 90 100 75.00% 77.50% 80.00% 82.50% 85.00% 87.50% 90.00% 92.50% 95.00% 90V 115V 180V 230V 264V VIN EFF% 0.00% 10.00% 20.00% 30.00% 40.00% 50.00% 60.00% 70.00% 80.00% 90.00% 100.00% LOAD EFF% AQF360E-24S VIN VS Efficiency LOAD VS Efficiency Input Voltage (V) 90 115 180 230 264 Load (%) 0 10 20 30 40 50 Load (%) 60 70 80 90 100 75.00% 77.50% 80.00% 82.50% 85.00% 87.50% 90.00% 92.50% 95.00% 90V 115V 180V 230V 264V VIN EFF% 0.00% 10.00% 20.00% 30.00% 40.00% 50.00% 60.00% 70.00% 80.00% 90.00% 100.00% LOAD EFF%

VER : C_6 update : 2015.11.16 AC-DC Switching Power Supply AQF360E SERIES 360 Watts http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -5- EFFICIENCY VERSUS LOAD AQF360E-36S VIN VS Efficiency LOAD VS Efficiency Input Voltage (V) 90 115 180 230 264 Load (%) 0 10 20 30 40 50 Load (%) 60 70 80 90 100 75.00% 77.50% 80.00% 82.50% 85.00% 87.50% 90.00% 92.50% 95.00% 90V 115V 180V 230V 264V VIN EFF% 0.00% 10.00% 20.00% 30.00% 40.00% 50.00% 60.00% 70.00% 80.00% 90.00% 100.00% LOAD EFF% AQF360E-48S VIN VS Efficiency LOAD VS Efficiency Input Voltage (V) 90 115 180 230 264 Load (%) 0 10 20 30 40 50 115V (%) 0 86.43 89.33 9143 92.17 92.58 230V (%) 0 8680 90.87 92.74 93.47 94.02 Load (%) 60 70 80 90 100 75.00% 77.50% 80.00% 82.50% 85.00% 87.50% 90.00% 92.50% 95.00% 90V 115V 180V 230V 264V VIN EFF% 0.00% 10.00% 20.00% 30.00% 40.00% 50.00% 60.00% 70.00% 80.00% 90.00% 100.00% LOAD EFF%

VER : C_6 update : 2015.11.16 AC-DC Switching Power Supply AQF360E SERIES 360 Watts http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -6- EFFICIENCY VERSUS LOAD AQF360E-54S VIN VS Efficiency LOAD VS Efficiency Input Voltage (V) 90 115 180 230 264 Load (%) 0 10 20 30 40 50 Load (%) 60 70 80 90 100 75.00% 77.50% 80.00% 82.50% 85.00% 87.50% 90.00% 92.50% 95.00% 9 0 V 1 1 5 V1 8 0 V2 3 0 V2 6 4 V VIN EFF% 0.00% 10.00% 20.00% 30.00% 40.00% 50.00% 60.00% 70.00% 80.00% 90.00% 100.00% LOAD EFF%