Features
Low Forward Voltage: 0.5V @ +25C High Surge Current Capacity +125C Operating Junction Temperature 1A Total Guard-Ring for Stress Protection DO-41 Lead-Free Finish; RoHS Compliant (Notes 1 & 2) Available in “Green” Packages: DO-214AC, DO-41 Lead-Free Finish; RoHS Compliant (Notes 1 & 2) Halogen and Antimony Free. “Green” Device (Note 3) Mechanical Data Case: DO-214AC, DO-41 Case Ma terial: Molded Plastic, “Green” Molding Compound. UL Flammability Classification Rating 94V-0 Moisture Sensitivity: Level 1 per J-STD-020 Terminals: Finish - Matte Tin Annealed over Copper Leadframe. Solderable per MIL-STD-202, Method 208 Weight DO-41 – 0.33Grams (Approximately) DO-214AC – 0.062Grams (Approximately) DO-41 DO-214AC Notes: 1. EU Directive 2002/95/EC (RoHS) & 2011/65/EU (RoHS 2) compliant. All applicable RoHS exemptions applied. 2. See http://www.diodes.com/quality/lead_free.html for more information about Diodes Incorporated’s definitions of Halogen- and Antimony-free, "Green" and Lead-free. 3. Halogen- and Antimony-free "Green” products are defined as those which contain <900ppm bromine, <900ppm chlorine (<1500ppm total Br + Cl) and <1000ppm antimony compounds. Pin Assignments (Top View) (Top View) DO-41 DO-214AC Cathode line by marking Cathode line by marking Cathode Anode Cathode Anode
Document number: DS36974 Rev. 3 - 2 2 of 9 www.diodes.com July 2014 © Diodes Incorporated APD140 Ordering Information (Note 4) PackingPackageProduct Name E1/G1 APD140 XX XX - XX Blank: BulkVD: DO-41 G1: GreenVR: DO-214AC TR: Tape & Reel E1 : RoHS Compliant or Ammo Note 4: Diodes Inc’s Pb-free products, as designated with " E1" suffix in the part number, are RoHS compliant . Products with "G1" suffix are available in green packages. Package Temperature Range Part Number Marking ID Packing DO-41 -65 to +125oC APD140VD-E1 D140VD 1000/Bulk DO-41 -65 to +125oC APD140VD-G1 140VDG 1000/Bulk DO-41 -65 to +125oC APD140VDTR-E1 D140VD 2500/Ammo DO-41 -65 to +125oC APD140VDTR-G1 140VDG 2500/Ammo DO-214AC -65 to +125oC APD140VRTR-G1 140VRG 7500/Tape & Reel Marking Information (1) DO-214AC (Top View) Pb Green First Line: Logo and Date Code Y: Year WW: Work Week of Molding A: Assembly House Code Second Line: Marking ID (See Ordering Information) Pb Green Green YWWA XXXXXX
Document number: DS36974 Rev. 3 - 2 3 of 9 www.diodes.com July 2014 © Diodes Incorporated APD140 Marking Information (Cont.) (2) DO-41 (Top View) Maximum Ratings (TA = +25oC, unless otherwise noted.) (Note 5) Characteristic Symbol Rating Unit Maximum Repetitive Reverse Voltage VRRM 40 V Maximum DC Blocking Voltage VDC Maximum RMS Voltage VRMS 28 V Average Rectified Forward Current 0.375 " (9.5mm) Lead Length (See Figure 1) IF(AV) 1.0 A Non-Repetitive Peak Forward Surge Current 8.3ms Single Half Sine-wave on Rated Load IFSM 35 A Voltage Rate of Change (Rated VR) dv/dt 10000 V/μS Operating Junction Temperature Range (Note 6) TJ -65 to +125 oC Storage Temperature Range TST -65 to +150 oC Notes: 5. Stresses greater than those listed under “Absolute Maximum Ratin gs” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “Recommended Operating Condi tions” is not implied. Exposure to “Absolute Maximum Ratings” for extended periods may affect device reliability. 6. The heat generated must be less than the thermal conductivity from Junction to Ambient : dPD/dTJ < 1/θJA. First Line: Logo and Date Code Y: Year WW: Work Week of Molding A: Assembly House Code Second Line: Marking ID (See Ordering Information) YWWA XXXXXX
Document number: DS36974 Rev. 3 - 2 4 of 9 www.diodes.com July 2014 © Diodes Incorporated APD140 Thermal Characteristics (TA = +25oC, unless otherwise noted.) Characteristic Symbol Rating Unit Typical Thermal Resistance (Note 7) RθJA DO-41 65 oC/W DO-214AC 100 Note 7: Device mounted on heat sink, with minimum recommended pad layout per http://www.diodes.com Electrical Characteristics (TA = +25oC, unless otherwise noted.) Characteristic Symbol Rating Unit Test Condition Forward Voltage @ IF = 1.0A VF 0.5 V – Reverse Current @ Rated VR (Note 8) IR 0.5 mA TA = +25oC
10 TA = +100oC
Note 8: Short duration pulse test used to minimize self-heating effect, Pulse Test: 300μs pulse width, 1.0% duty cycle.
Document number: DS36974 Rev. 3 - 2 6 of 9 www.diodes.com July 2014 © Diodes Incorporated APD140 Package Outline Dimensions (All dimensions in mm(inch).) (1) Package Type: DO-41 0.700(0.028) 4.200(0.165) 5.200(0.205) 2.000(0.080) 2.700(0.107) DIA. DIA. 25.400(1.000) MIN Cathode line by marking
Document number: DS36974 Rev. 3 - 2 7 of 9 www.diodes.com July 2014 © Diodes Incorporated APD140 Package Outline Dimensions (Cont. All dimensions in mm(inch).) (2) Package Type: DO-214AC 3.990(0.157) 4.750(0.187) 2.400(0.094) 2.830(0.111) 1.250(0.049) 1.650(0.065) 4.800(0.189) 5.280(0.208) 0.760(0.030) 1.520(0.060) 1.900(0.075) 2.290(0.090) 0.080(0.003) 0.310(0.012) 0.150(0.006) 0.310(0.012) Cathode line by marking
Document number: DS36974 Rev. 3 - 2 8 of 9 www.diodes.com July 2014 © Diodes Incorporated APD140 Suggested Pad Layout (1) Package Type: DO-214AC G X Y Dimensions Y (mm)/(inch) (mm)/(inch) G (mm)/(inch) X (mm)/(inch)
Document number: DS36974 Rev. 3 - 2 9 of 9 www.diodes.com July 2014 © Diodes Incorporated APD140 IMPORTANT NOTICE DIODES INCORPORATED MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARDS TO THIS DOCUMENT, INCLUDING, BUT NOT LIMITED TO, THE IM PLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE (AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION). Diodes Incorporated and its subsidiaries reserve the right to make modifications, enhancements, improvements, correction s or other changes without further notice to this document and any product described herein. Diodes Incorporated does not assume any liability a rising out of the application or use of this document or any product described herein; neither does Diodes Incor porated convey any license under its patent or trademark rights, nor the rights of others. Any Customer or user of this document or products described herein in such appli cations shall assume all risks of such use and will agree to hold Diodes Incorporate d and all the companies whose products are represented on Diodes Incorporated website, harmless against all damages. Diodes Incorporated does not warrant or accept any liability whatsoever in respect of any products purchased through unauthorized sales channel. Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorn ey fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized application. Products described herein may be covered by one or more United States, international or foreign patents pend ing. Product names and markings noted herein may also be covered by one or more United States, international or foreign trademarks. This document is written in English but may be translated into multiple languages for reference. Only the English version of this document is the final and determinative format released by Diodes Incorporated. LIFE SUPPORT Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or system s without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform w hen properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in significant injury to the user. B. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or to affect its safety or effectiveness. Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life suppo rt devices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of Diodes Incorporated products in such safety -critical, life support devices or systems, notwithstanding any devices - or systems -related information or support that may be provided by Diodes Incorporated. Further, Customers must fully indemnify Diodes Incorpora ted and its representatives against any damages arising out of the use of Diodes Incorporated products in such safety-critical, life support devices or systems. Copyright © 2014, Diodes Incorporated www.diodes.com