Datasheet search site | www.alldatasheet.com

Document overview

  • Manufacturer or author: Diodes Incorporated
  • PDF pages: 16

Technical content

Features

  • Primary Side Control for Eliminating Optocoupler
  • Built-In 650V Power MOSFET of AP3981D2
  • 75mW No-Load Input Power
  • Flyback Topology in DCM Operation
  • External Adjustable Line Compensation for CC
  • Fixed Internal Cable Compensation
  • Multiple Segment AM/PFM Control Mode to Improve Audio Noise and Efficiency
  • Frequency Jitter to Improve System EMI
  • Capacitive Load Start-Up Capability
  • Valley-On for the Higher Efficiency and Better EMI Behavior
  • Multiple Protections:
  • Secondary-Side Overvoltage Protection (SOVP)
  • Secondary-Side Undervoltage Protection (SUVP)
  • Output Short-Circuit Protection (SCP)
  • Transformer Saturation Protection (TSP) via Primary Peak Current Limitation
  • Internal Overtemperature Protection (OTP)
  • SO-8 Package
  • Totally Lead-Free & Fully RoHS Compliant (Notes 1 & 2)
  • Halogen and Antimony Free. “Green” Device (Note 3) Pin Assignments (Top View) SO-8

Applications

  • Routers
  • Set-Top Box (STB) Power Supply
  • Network Adaptors Notes: 1. No purposely added lead. Fully EU Directive 2002/95/EC (RoHS), 2011/65/EU (RoHS 2) & 2015/863/EU (RoHS 3) compliant . 2. See https://www.diodes.com/quality/lead-free/ for more information about Diodes Incorporated’s definitions of Halogen- and Antimony-free, "Green" and Lead-free. 3. Halogen- and Antimony-free "Green” products are defined as those which contain <900ppm bromine, <900ppm chlorine (<1500ppm total Br + Cl) and <1000ppm antimony compounds. FB VCC SOURCE GND DRAIN DRAIN DRAIN DRAIN AP3981D2 Document number: DS41421 Rev. 2 - 2 1 of 16 www.diodes.com May 2019 © Diodes Incorporated

Typical Applications Circuit AC C13 T 1 R17 C12 CY1 GND DRAIN SOURCE VCC AP3981D2 FB VOUT GND 5,6,7,8 R18 R2D1 DB1 R13R16R15 C10 R7 R9 C14 Pin Descriptions Pin Number Pin Name Function

1 GND IC ground

Connect to the auxiliary winding through a divider network. Used as a multi-function pin to realize output voltage sample for CV control, tons detection for CC control, line voltage sense for line compensation, and FB-negative-protection detection.

3 VCC IC power supply

4 SOURCE SOURCE terminal of the integrated MOSFET

5, 6,7,8 DRAIN DRAIN terminal of the integrated MOSFET AP3981D2 Document number: DS41421 Rev. 2 - 2 2 of 16 www.diodes.com May 2019 © Diodes Incorporated

Controller Functional Block Diagram Regulator Bias PFM t ONS UVLO CV_CTRL PFM Valley ON R Q S R Q S FB VCC GND Constant Voltage Control Constant Current Control tONS Detector 0.1V VCS_REF COMP EA Peak Current Control & LEB tONS Pro CC_CTRL ShutdownLine Compensation DRAIN 5, 6, 7, 8 Low Pass VCPC VREF Driver VLINE VCC OVP FB OVP/SUVP/SCP RFB Short/Open Protection Rcs Short/Open Protection Transformer Saturation Protection VCC VCS Square Root Function Cable Compenstaion VCPC VCPC

4 SOURCE

VCS_REF AP3981D2 Document number: DS41421 Rev. 2 - 2 3 of 16 www.diodes.com May 2019 © Diodes Incorporated

Absolute Maximum Ratings (Note 4) Symbol Parameter Rating Unit VCC Supply Voltage -0.3 to 35 V VSOURCE SOURCE Input Voltage -0.3 to 8 V VFB FB Input Voltage -0.3 to 8 V VDS Drain-Source Voltage (TJ=+25°C) 650 V TJ Operating Junction Temperature -40 to +150 °C TSTG Storage Temperature -65 to +150 °C TLEAD Lead Temperature (Soldering, 10 sec) +300 °C ϴJC Thermal Resistance (Junction to Case) (Note 5) 3 °C/W ϴJA Thermal Resistance (Junction to Ambient) (Note 5) 65 °C/W — ESD (Human Body Model) 2000 V — ESD (Charged Device Model) 1000 V Notes: 4. Stresses greater than those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions is not implied. Exposure to Absolute Maximum Ratings for extended periods may affect device reliability. 5. Test condition: Device mounted on FR-4 substrate PC board, 2oz copper, with 1in2 cooling area. Recommended Operating Conditions Symbol Parameter Min Max Unit VCC Supply Voltage 10 28 V TA Ambient Temperature -40 +85 °C AP3981D2 Document number: DS41421 Rev. 2 - 2 4 of 16 www.diodes.com May 2019 © Diodes Incorporated

Electrical Characteristics (@TA =+25°C, VCC = 15V, unless otherwise specified.) Symbol Parameter Condition Min Typ. Max Unit STARTUP AND UVLO SECTION VTH_ST Startup Threshold — 14.5 16 17.5 V VOPR(MIN) Minimum Operating Voltage — 6.1 6.8 7.5 V STANDBY CURRENT SECTION IST Startup Current VCC=VTH_ST-1V before Startup — 1 3 µA ICC_OPR Minimum Operating Current Static Current 450 550 650 µA CURRENT SENSE SECTION VCS_H Peak Current Sense Threshold Voltage 40% to 100% CC Load 560 630 700 mV VCS_L No Load to 2% CC Load 160 180 200 mV RLINE Built-In Line Compensation Resistor — 45 55 65 Ω tLEB Leading Edge Blanking — 370 470 570 ns CONSTANT VOLTAGE SECTION VFB Feedback Threshold Voltage Closed Loop Test of VOUT 2.35 2.4 2.45 V RatioSAMPLE_L Sample Ratio No Load to 2% CC Load 45 50 55 % RatioSAMPLE_H Sample Ratio 40% to 100% CC Load 75 80 85 % CONSTANT CURRENT SECTION tONS/tSW Below SUVP Tested @ VFB=1V — 0.75 — — Above SUVP Tested @ VFB=2V — 0.5 — — FREQUENCY JITTER ΔVCS/VCS VCS Modulation 10% Load to Full Load 1.5 2 2.5 % Cable Compensation VCABLE/VOUT Fixed Cable Compensation Ratio — — 4 — % VALLEY-ON SECTION tVAL-ON Valid Off Time of Valley-on From the End of tONS 26 32 38 µs DYNAMIC SECTION tOFF(MAX) Maximum Off Time — 1.8 2 2.2 ms PROTECTION FUNCTION SECTION VFB(SOVP) Overvoltage Protection at FB Pin — 3.3 3.6 3.9 V VFB(SUVP) Undervoltage Protection at FB Pin — 1.22 1.35 1.48 V tDELAY(SUVP) Delay Time of SUVP — 116 128 140 ms VFB(SCP) Output Short Protection at FB Pin — 680 750 820 mV tDELAY(SCP) Delay Time of SCP — 58 64 70 ms VCC(OVP) Overvoltage Protection at VCC Pin — 29.5 32 34.5 V tONP(MAX) Maximum Turn-on Time — 12 16 20 µs VCS(MIN) Minimum Peak Current Sense Voltage at tONP=4µs — 120 150 180 mV VCS(MAX) Maximum CS Voltage — 720 800 880 mV AP3981D2 Document number: DS41421 Rev. 2 - 2 5 of 16 www.diodes.com May 2019 © Diodes Incorporated

Electrical Characteristics (continued) (@TA =+25°C, VCC = 15V, unless otherwise specified.) Symbol Parameter Condition Min Typ Max Unit PROTECTION FUNCTION SECTION VFB_NEG_L Low Threshold for FB Negative Voltage Protection — 11 14 17 mV VFB_NEG_H High Threshold for FB Negative Voltage Protection — 27 36 45 mV TOTP Shutdown Temperature — +130 +145 +160 °C THYS Temperature Hysteresis — +27 +30 +33 °C POWER MOSFET SECTION BVDSS Integrated MOSFET Drain-Source Break-Down Voltage (Note 6) — 650 — — V RDS(ON) Static Drain-Source On-Resistance — — 1.7 2.5 Ω ID Drain Current -Continuous — — — 4 A Note: 6. The aging condition of drain-source voltage is 80% of BVDSS. AP3981D2 Document number: DS41421 Rev. 2 - 2 6 of 16 www.diodes.com May 2019 © Diodes Incorporated

Performance Characteristics Start-Up Voltage vs. Ambient Temperature -40 -20 0 20 40 60 80 100 120 140 15.0 15.5 16.0 16.5 17.0 17.5 18.0 Ambient Temperature ( o Start-up Voltage (V) Start-Up Current vs. Ambient Temperature -40 -20 0 20 40 60 80 100 120 140 Start-up Current (µA) Ambient Temperature ( o Minimal Operating Voltage vs. Ambient Temperature -40 -20 0 20 40 60 80 100 120 140 Ambient Temperature ( o Minimun Operating Voltage (V) Operating Current vs. Ambient Temperature -40 -20 0 20 40 60 80 100 120 140 300 350 400 450 500 550 600 650 700 Ambient Temperature ( o Operating Current (µA) VCS_H vs. Ambient Temperature -40 -20 0 20 40 60 80 100 120 140 600 620 640 660 680 700 Ambient Temperature ( o VCS_H (mV) tONS/tSW Above SUVP vs. Ambient Temperature -40 -20 0 20 40 60 80 100 120 140 0.2 0.3 0.4 0.5 0.6 0.7 0.8 Ambient Temperature ( o tONS/tSW AP3981D2 Document number: DS41421 Rev. 2 - 2 7 of 16 www.diodes.com May 2019 © Diodes Incorporated

Performance Characteristics (continued) Feedback Voltage vs. Ambient Temperature -40 -20 0 20 40 60 80 100 120 140 2.20 2.25 2.30 2.35 2.40 2.45 2.50 Ambient Temperature ( o Feedback Voltage (V) VCC OVP Voltage vs. Ambient Temperature -40 -20 0 20 40 60 80 100 120 140 Ambient Temperature ( o Vcc OVP voltage (V) Line Compensation Resistance vs. Ambient Temperature -40 -20 0 20 40 60 80 100 120 140 100 Ambient Temperature ( o Line Compensation Resistance (Ω) Maximum Off Time vs. Ambient Temperature -40 -20 0 20 40 60 80 100 120 140 1.0 1.5 2.0 2.5 3.0 Ambient Temperature ( o Maximum Off Time (ms) Low Threshold Voltage for FB_Negative Protection vs. Ambient Temperature -40 -20 0 20 40 60 80 100 120 140 Ambient Temperature ( o Low Threshold Voltage for FB_Neg Protection (mV) Feedback Voltage of SUVP vs. Ambient Temperature -40 -20 0 20 40 60 80 100 120 140 1.2 1.3 1.4 1.5 1.6 1.7 1.8 Ambient Temperature ( o VFB of SUVP (V) AP3981D2 Document number: DS41421 Rev. 2 - 2 8 of 16 www.diodes.com May 2019 © Diodes Incorporated

Operation Principle Description (continued) As shown in Figure 1, when the current ip(t) rises up to IPK, the primary MOSFET turns off. The constant peak current is given by: (2) CS CS PK R VI = Therefore, the energy stored in the magnetizing inductance LM each cycle is: (3) PKM ILEg ⋅×= So the power transferring from the input to the output is given by: (4) SWPKM fILP ×××= Where the fSW is the switching frequency. When the peak current IPK is constant, the output power depends on the switching frequency fSW. 2. Constant Voltage Operation The output voltage is proportional to the auxiliary winding voltage during tONS period indicated by Equation 5, this auxiliary winding voltage is divided by resistors RFB1 and RFB2 (refer to Figure 5) before inputting to the FB PIN. As shown in Figure 2, AP3981D2 detects the FB voltage at the end of tSAMPLE during tONS period, the detected voltage that reflects the output voltage is regulated to VFB of 2.4V with the help of the constant voltage control block in AP3981D2. For system design, adjust the ratio of RFB1 and RFB2 can get the target output voltage value. (5) ( )VdVoN NV S AUX AUX +×= tONS tSAMPLE tSW Figure 2: Auxiliary Voltage Waveform 3. Constant Current Control In AP3981D2, Equation 6 shows the related parameters that determine the output current. To get a constant output current, the V CS and tONS/tSW is fixed in AP3981D2 during CC mode. Meanwhile, a reliable control logic is integrated within AP3981D2 to ensure the system swift smoothly between CC mode and CV mode. (6) 4. Multiple Segment Peak Current In the original PFM PSR system, the switching frequency decreases with the decreasing output current, which will encounter audible noise issue when switching frequency decreases below 20kHz. SW ONS SW ONS t t Rcs Vcs Ns Np t tIpkNs NpIout *2 1*2 1 == AP3981D2 Document number: DS41421 Rev. 2 - 2 10 of 16 www.diodes.com May 2019 © Diodes Incorporated

rises above 20kHZ at a varying slope. Figure 3. Segment Peak Current and Operating Frequency at CV Mode ratio rises linearly from 50% to 80%.

  1. Capacitive Load Start-Up Capability

MOSFET cannot be turned off. achieve the better radiative EMI performance.

Operation Principle Description (cont.) The final compensated VCS is: (8) In the above equations, VPP is 1.8V at CC mode, RLC is 55Ω, R2 is 60kΩ, R1 is two times of R2, VAUX is the value of the auxiliary winding voltage during primary-on period, which proportional to bus voltage. Based on the equation, it can be concluded that a smaller RFB1 results in deeper line compensation. If the delay time, tDELAY, is known—typically 150ns in AP3981D2, the RFB1 can be calculated as a reference for the system design. 11. Protection AP3981D2 provides versatile protections to prevent the system from damage under various fault conditions. Most protections trigger auto-recovery mode in which the system restarts as soon as the VCC drops to VOPR(MIN). When the fault conditions are removed, the system recovers to normal operation automatically. VCC OVP A VCC OVP threshold is set to protect the IC from damage. When the VCC OVP protection is triggered, the IC stops outputting drive signal immediately, and the system enters auto-recovery mode. Output Overvoltage Protection (SOVP) As previously described, the FB pin voltage during tons reflects the output voltage proportionally . This voltage can be used to realize SOVP. AP3981D2 sets a higher threshold, VFB(OVP), to shutdown the system if the sampled voltage reaches the threshold continuously for three switching cycles. The SOVP is then triggered, and the system enters auto-recovery mode. Output Undervoltage Protection (SUVP) Like SOVP, the AP3981D2 also integrated the SUVP protection. If the detected voltage on FB pin is lower than VFB(SUVP) for 128ms, the SOVP is triggered, and the system enters auto-recovery mode. Output Short Protection (SCP) A much lower threshold is set on FB pin to protect the system when output short condition occurs . If the detected FB voltage is lower than 0.78V for 64ms, the SCP is triggered, and the system enters auto-recovery mode. Transformer Anti-Saturation Protection Under some fault condition s or bad system design, the transformer may approach saturation, and the current increases dramatically. To avoid power device damage due to transformer saturation, AP3981D2 integrates a maximum VCS threshold VCS(MAX) to protect the system. If there are three consecutive pulses where VCS exceeds the threshold, the controller shuts down and enters auto-recovery mode. Overtemperature Protection (OTP) If the IC junction temperature exceeds the threshold of TOTP, AP3981D2 shuts down immediately and enters auto-recovery mode. Note that even when the VCC reaches VTH_ST, the IC does not output any drive pulse until the junction temperature falls at a hysteresis temperature of +30°C. Brown-In/ Brown-Out Protection AP3981D2 detects the bus voltage at each switching cycle through FB p in during tONP period. When the V CC reaches VTH_ST after power on, AP3981D2 outputs one switching pulse to check if the detected bus voltage on FB pin is higher than VFB_NEG_H. In this case, the system starts up normally; otherwise, AP3981D2 stops outputting following pulses. The V CC then drops below VOPR(MIN), and the system repeat s the process described above until the detected FB voltage is higher than VFB_NEG_H. When the power is off or there is a ditch in bus voltage, and if the detected voltage is lower than VFB_NEG_L for three consecutive switching cycles, the IC shuts down and enters auto-recovery mode. This function is very useful when the bulk capacitor is open or when the heavy load suddenly releases after power off. LCPPREF_CS V*3 2V*3 1V += AP3981D2 Document number: DS41421 Rev. 2 - 2 13 of 16 www.diodes.com May 2019 © Diodes Incorporated

Ordering Information

13 : 13" Tape & ReelS: SO-8 Product Name Package Part Number Marking ID 13’Tape and Reel Quantity Part Number Suffix SO-8 AP3981D2S-13 3981D2 4000/Tape and Reel -13 Marking Information SO-8 3981D2 (Top View) YY WW X X Logo WW : Week : 01~52; 52 YY : Year : 18, 19, 20~ X X : Internal Code 8 7 6 5 1 2 3 4 represents 52 and 53 week Marking ID AP3981D2 Document number: DS41421 Rev. 2 - 2 14 of 16 www.diodes.com May 2019 © Diodes Incorporated

Package Outline Dimensions (All dimensions in mm (inch).) Please see http://www.diodes.com/package-outlines.html for the latest version. SO-8 SO-8 Dim Min Max Typ A 1.40 1.50 1.45 A1 0.10 0.20 0.15 b 0.30 0.50 0.40 c 0.15 0.25 0.20 D 4.85 4.95 4.90 E 5.90 6.10 6.00 E1 3.80 3.90 3.85 E0 3.85 3.95 3.90 e — — 1.27 h — — 0.35 L 0.62 0.82 0.72 Q 0.60 0.70 0.65 All Dimensions in mm Suggested Pad Layout Please see http://www.diodes.com/package-outlines.html for the latest version. SO-8 Dimensions Value (in mm) C 1.27 X 0.802 X1 4.612 Y 1.505 Y1 6.50 Note: The suggested land pattern dimensions have been provided for reference only, as actual pad layouts may vary depending on appl ication. These dimensions may be modified based on user equipment capability or fabrication criteria. A more robust pattern may be desired for wave soldering and is calculated by adding 0.2 mm to the ‘Z’ dimension. For further information, please reference document IPC-7351A, Naming Convention for Standard SMT Land Patterns, and for International grid details, please see document IEC, Publication 97. Note: For high voltage applications, the appropriate industry sector guidelines should be considered with regards to creepage and c learance distances between device Terminals and PCB tracking. b e E A 9° ( All sides) 4°±3° c Q h 45° R 0.1 D L Seating Plane Gauge Plane C X Y AP3981D2 Document number: DS41421 Rev. 2 - 2 15 of 16 www.diodes.com May 2019 © Diodes Incorporated

DIODES INCORPORATED MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARDS TO THIS DOCUMENT, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE (AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION). Diodes Incorporated and its subsidiaries reserve the right to make modifications, enhancements, improvements, corrections or o ther changes without further notice to this document and any product described herein. Diodes Incorporated does not assume any liability arising out of the application or use of this document or any product described herein; neither does Diodes Incorporated convey any license under its patent or trademark rights, nor the rights of others. Any Customer or user of this document or products described herein in such applications shall assume all risks of such use and will agree to hold Diodes Incorporated and all the companies whose products are represented on Diodes Incorporated website, harmless against all damages. Diodes Incorporated does not warrant or accept any liability whatsoever in respect of any products purchased through unauthorized sales channel. Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customer s shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized application. Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings noted herein may also be covered by one or more United States, international or foreign trademarks. This document is written in English but may be translated into mul tiple languages for reference. Only the English version of this document is the final and determinative format released by Diodes Incorporated. LIFE SUPPORT Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided i n the labeling can be reasonably expected to result in significant injury to the user. B. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or to affect its safety or effectiveness. Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of Diodes Incorporated products in such safety -critical, life support devices or systems, notwithstanding any devices - or systems -related information or support that may be pr ovided by Diodes Incorporated. Further, Customers must fully indemnify Diodes Incorporated and its representatives against any damages arising out of the use of Diodes Incorporated products in such safety-critical, life support devices or systems. Copyright © 2019, Diodes Incorporated www.diodes.com AP3981D2 Document number: DS41421 Rev. 2 - 2 16 of 16 www.diodes.com May 2019 © Diodes Incorporated