AMS3011 ANALOGMICRO | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 8

Technical content

Miniaturized pressure transmitter with 0 .. 5 V output Analog Microelectronics GmbH An der Fahrt 13, D – 55124 Mainz April 2016 – Rev. 1.0 Phone:+49 (0)6131/91 0730-0 Fax: +49 (0)6131/91 073-30 Internet: www.analogmicro.de E–Mail: info@analogmicro.de

FEATURES

 Amplified pressure sensor with standardized 0 .. 5 V output  Calibrated and temperature compensated  Wide variety of pressure ranges: 25 mbar up to 10 bar  Differential / gage, bidirectional differential, absolute and barometric versions  Piezoresistive sensing element  High precision digital signal conditioning  High accuracy at room temperature  Low overall error within a temperature range of -25 .. +85 °C  Supply voltage range: 8 .. 36 V  Robust and miniaturized metal package  Pressure connection: M5 female thread  Electrical connection: M5 sensor connector  Simple and quick installation  Dust- and water-tight (IP67)  RoHS and REACH compliant TYPICAL APPLICATIONS  Static and dynamic pressure sensing  Barometric pressure sensing  Vacuum measurement  Level measurement  Medical instrumentation  Indoor and outdoor measurement  Pneumatic system monitoring  Test benches GENERAL DESCRIPTION AMS 3011 is a series of robust pressure transmitters in a matchbox -sized IP67 metal package. This series is suitable for high preci sion measurements in industrial indoor and outdoor applications as well as in medical instrumentation. All sensors in this series provide an analog output signal of 0 .. 5 V and can be powered within a wide supply voltage range of VS = 8 .. 36 V . They are calibrated and temperature compensated in a wide temperature range of -25 .. +85°C. AMS 3011 comes in a r ugged metal package with M5 female thread s for pressure connection. Using standard M5 pressure fittings like barbed ports, hose or push -in fittings a w ide variety of pressure connections can be established. The sensor’s electrical connection is realized with a n M5 circular sensor c onnector. AMS 3011’s package is dust- and water-tight conforming to IP67. The pressure transmitters in the AMS 3011 series are available for various pressure types and ranges: differential (relative) devices in pressure ranges from 0 .. 50 mbar up to 0 .. 10 bar, absolute pressure variants for 0 .. 1 bar and 0 .. 2 bar as Bidirectional-differential devices for measurement of positive and negative differential pressure are Customized pressure ranges and output voltage ranges are available on request.

Miniaturized pressure transmitter with 0 .. 5 V output April 2016 – Rev. 1.0 Page 2/8 www.analogmicro.de PRESSURE RANGES Pressure transmitter type (code) Pressure type Pressure range in mbar Burst pressure1) in bar Pressure range in PSI Burst pressure1) in PSI Low pressure Standard pressure Medium pressure Table 1: AMS 3011 standard pressure ranges (other ranges on request) MAXIMUM RATINGS Parameter Minimum Typical Maximum Units Maximum supply voltage: VS,max 36 V Operating and storage temperature: T -25 85 °C Common mode pressure: pCM 2) 16 bar Table 2: Maximum ratings Notes: 1) Burst pressure is defin ed as the maximum pressure, which can be applied to one pressure port relative to the other port (or while only one pressure port is connected) without causing damages / leaks. 2) Common mode pressure is defined as the maximum pressure, which can be applied simultaneously on both pressure ports of a differential or bidirectional transmitter without causing damages, while no differential pressure is applied.

Miniaturized pressure transmitter with 0 .. 5 V output April 2016 – Rev. 1.0 Page 3/8 www.analogmicro.de SPECIFICATIONS All parameters apply to VS = 24 V, Top = 25°C and RL = 10 kΩ, unless otherwise stated. Parameter Minimum Typical Maximum Units Analog output signal @ specified minimum pressure (see “pressure ranges”)1) @ specified maximum pressure (see “pressure ranges”)1) Full span output (FSO)2) without pressure (only bidirectional differential types) < 0.025 2.5 0.05 V V V V Accuracy3) @ Top = 25°C Low pressure types (50, 100 mbar) Standard pressure types (200, 350, 500, 1000, 1200 mbar) Medium pressure types (> 1200 mbar) ±0.5 ±0.5 ±0.5 ±1.0 ±1.0 ±1.0 %FSO %FSO %FSO Overall error4) @ Top = -25 .. 85°C Low pressure types (50, 100 mbar) Standard pressure types (200, 350, 500, 1000, 1200 mbar) Medium pressure types (> 1200 mbar) ±1.0 ±0.7 ±0.7 ±2.0 ±1.5 ±1.5 %FSO %FSO %FSO Long term stability < 0.5 %FSO/a Nonlinearity5) -0.3 < 0.1 0.3 %FSO Resolution analog output signal 0.05 %FSO Supply voltage (VS to GND) 8 24 36 V Current consumption 5 mA Response time (10% .. 90% rise time) 1 2 ms Load resistor RL 2 kΩ Capacitive load 50 nF Dependency of VOUT on VS 6) < 0.1 %FSO Pressure Changes 106 Compensated operating temperature range TOP -25 85 °C Weight without cable 45 gram Package material standard: hard-eloxed aluminum on request: stainless steel 316 Media compatibility See notes7), 8) Protection classification9) IP67 Table 3: Specifications Specification Notes: 1) Pressure ranges are specified in Table 1. 2) The Full Span Output (FSO) is the algebraic difference between the output voltage at the specified minimum pressure and the output voltage at the specified maximum pressure (nominal FSO = 5 V). 3) The accuracy is defined as the maximum deviation of the measurement value from the ideal transfer function at room temperature (RT) in %FSO including the adjustment error (offset and span), nonlinearity, pre ssure hysteresis and repeatability. Nonlinearity is the measured deviation from the best fit straight line (BFSL) across the entire pressure range. Pressure hysteresis is the maximum deviation of the output value at any pressure within the specified range when the pressure is cycled to and from the specified minimum or maximum pressure. Repeatability is the maximum variation of the output value at any pressure within the specified range over 10 pressure cycles.

Miniaturized pressure transmitter with 0 .. 5 V output April 2016 – Rev. 1.0 Page 4/8 www.analogmicro.de 4) The overall error is defined as the maximum deviation of the measurement value from the ideal transfer function in %FSO across the entire temperature range (-25 … 85 °C). 5) Defined as best fit straight line (BFSL). 6) The given value is the maximum deviation from the output voltage at VS = 24 V over the complete supply voltage range at any pressure in the specified range. It is normalized to the FSO. 7) Media compatibility of pressure port 1 (for a description of port 1, see Figure 3): fluids and gases non-corrosive to ceramics, silicon, Pyrex, RTV silicone rubber, NBR rubber and package material (aluminum or stainless steel). 8) Media compatibility of pressure port 2 (for a description of port 2, see Figure 3): clean, dry gases, non-corrosive to ceramics, silicon, Pyrex, RTV silicone rubber, gold , tin , silver palladium, NBR rubber and package material (alkaline or acidic liquids can destroy AMS 3011). 9) With pressure and electrical connection established. FUNCTIONAL DESCRIPTION AMS 3011 combines a piezoresistive silicon chip and a mixed-signal integrated circuit (ASIC) on a ceramic substrate housed in a robust metal package. The piezoresistive silicon chip acts as pressure sensing element and the ASIC is used for amplification and signal-conditioning. The physical pressure, which is applied to AMS 3011’s pressure ports, is converted into a differential voltage signal by the sensing element. This differential voltage signal , which is almost proportional to the applied pressure, is converted into a standardized , temperature independent analog output voltage of VOUT = 0 .. 5 V by the signal-conditioning ASIC. The signal-conditioning is done in the following way (see Figure 1): At first the sensing element’s differential voltage signal is pre-amplified and converted into a digital signal using a 14-bit A/D converter (ADC). This digitized pressure signal is processed mathematically by the ASIC’s integrated microcontroller unit. To achieve a calibrat ed and temperature compensated output signal the microcontroller unit uses individual correction coefficients and a mathematical correction algorithm, which are stored in the ASIC’s EEPROM during AMS 3011’s factory calibration process . The temperature valu e needed for the temperature compensation is measured directly at the piezoresistive sensing element, too. To obtain an analog output voltage the corrected digital signal is converted back into an analog voltage by an 11-bit D/A converter (DAC). The standardized output voltage VOUT = 0 .. 5 V (or 2.5 V ± 2.5 V for bidirectional differential types) is a linear function of the applied pressure.1 It is independent of the applied supply voltage. 1 The applied pressure is the pressure difference between port 1 and port 2 for differential and bidirectional differentia l pressure transmitters. For relative pressure types it is the pressure difference between port 1 and ambient pressure and for absolute and barometric pressure types it is the pressure at port 2 (for the definition of ports see Figure 3). Figure 1: AMS 3011’s block diagram

Miniaturized pressure transmitter with 0 .. 5 V output April 2016 – Rev. 1.0 Page 5/8 www.analogmicro.de INITIAL OPERATION The pressure transmitters of the series AMS 3011 can be screw mounted in a fast and easy way using the two integrated through bores (Ø 4.3 mm) at the sensor’s metal package’s edges. The electrical connection is established using the integrated M5 circular sensor connector and a suita ble cable with female M5 sensor connector (see “additional equipment”). Pin 1 (Vs) is directly connected to the power supply’s positive output and pin 4 (GND) is connected to GND (see Figure 2). Pin 3 (OUT) can be connected to a voltmeter directly to measure the output signal voltage VOUT (referenced to GND) or a load resistor RL can be connected between pin 3 and GND and VOUT can be measured parallel to RL. The output voltage VOUT = 0 .. 5 V at pin 3 is a linear function of the applied pressure and does not depend on the supply voltage. Please ensure that the supply voltage is in the specified range of 8 and 36 V and that the power supply is able to source at least 5 mA (for RL ≥ 10 kΩ) The pressure connection is made using the package’s M5 female thread pressure ports, where a multitude of pressure fittings can be connected (see “ additional equipment ”). Depending on the type of pressure transmitter and the application one or two of the pressure ports have to be connected to the measuring media/volume. For the pressu res at AMS 3011’s pressure ports the following requirements have to be fulfilled, wherein p1 is the pressure at port 1 and p2 is the pressure at port 2 (for port definition see Figure 3): for differential pressure (type AMS 3011-XXXX-D): p1 > p2 for relative / gage pressure (type AMS 3011-XXXX-D): p1 > pambient, p1 = measuring pressure for bidirectional differential pressure (type AMS 3011-XXXX-D-B): p1 > p2 or p1 < p2 possible for absolute pressure (type AMS 3011-XXXX-A): p2 = measuring pressure for barometric pressure (type AMS 3011-XXXX-B): p2 = measuring pressure The maximum pressures (see Table 1) and the guidelines concerning media compatibility (see specification notes 7) and 8)) have to be taken into account. AMS 3011’s package is dust - and water-tight according to IP6 7. Please keep in mind that AMS 3011 is on ly dust- and watertight if the electrical and the pressure connections are established. Figure 2: Electrical connection of AMS 3011

Miniaturized pressure transmitter with 0 .. 5 V output April 2016 – Rev. 1.0 Page 6/8 www.analogmicro.de DIMENSIONS AND PINOUT Notes: 1) For absolute and barometric pressure transmitters only port 2 is available. 2) The electrical connection is established using an M5 sensor connector series 707 from Binder GmbH. 3) For pressure connection Analog Microelectronics recommends the pressure fittings listed in “additional equipment”. Figure 3: Dimensions and pinout of AMS 3011's package

Miniaturized pressure transmitter with 0 .. 5 V output April 2016 – Rev. 1.0 Page 7/8 www.analogmicro.de INFORMATION FOR ORDERING Ordering code: Pressure range: Pressure range code mbar PSI kPa 0025 25 0.362 2.5 0050 50 0.725 5 0100 100 1.450 10 0200 200 2.901 20 0350 350 5.076 35 0500 500 7.251 50 1000 1000 14.50 100 1200 1200 17.40 120 2000 2000 29.01 200 4000 4000 58.02 400 7000 7000 101.52 700 10000 10000 145.0 1000 Table 4: Pressure ranges Pressure type: Pressure type code Available pressure ranges D differential / relative (gage) 0 .. 50 mbar to 0 .. 10000 mbar D-B bidirectional differential -25 .. +25 mbar to -1000 .. +1000 mbar A absolute 0 .. 1000 mbar and 0 .. 2000 mbar B barometric (absolute) 700 .. 1200 mbar Table 5: Pressure types ADDITIONAL EQUIPMENT ORDER NUMBER DELIVERY FORM AMS3011-CABLE 3-wire cable with mating M5 sensor connector (2 m long) wiring: brown – Vs, blue – OUT, black – GND

Miniaturized pressure transmitter with 0 .. 5 V output April 2016 – Rev. 1.0 Page 8/8 www.analogmicro.de Matching pressure fittings ORDER NUMBER DELIVERY FORM AMS3011-Barb-3 M5 barbed fitting with Ø = 3 mm, type: Festo CN-M5-PK-3 AMS3011-Barb-4 M5 barbed fitting with Ø = 4 mm, type: SMC M-5AN-6 AMS3011-Hose-4 M5 hose nipple with cap nut for tubing with Ø = 2.4 / 4 mm, type: SMC M-5H-4 AMS3011-Hose-6 M5 hose nipple with cap nut for tubing with Ø = 4 / 6 mm, type: SMC M-5H-6 AMS3011-PushIn-3 Push-In fitting for tubing with ØOD = 3 mm, type: Festo QSM-M5-3-I AMS3011-PushIn-4 Push-In fitting for tubing with ØOD = 4 mm, type: Festo QSM-M5-4-I AMS3011-PushIn-6 Push-In fitting for tubing with ØOD = 6 mm, type: Festo QSM-M5-6-I NOTES Analog Microelectronics GmbH reserves the right to amend any dimensions, technical data or other information contained herein without prior notifi cation.