Up to 50 Watt | DC-DC Converter www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 055e R3.C 1 of 9 North America only FEATURES: Models Single output Model Nom. Input Voltage (V) Output Voltage (V) Output Current max (A) Efficiency (%) Input Specifications Parameters Nominal Typical Maximum Units Voltage range 5 3~5.5 10~14 V Output Specifications Parameters Conditions Typical Maximum Units Set point Voltage accuracy ±2 % Trim range Full Resistive load 0.75~3.63 V Remote sense compensation 0.5 V Short Circuit protection R<10Ω Continuous Short Circuit restart Auto recovery Line voltage regulation Full Resistive load ±0.5 % of Vin Load voltage regulation NL-FL ±0.5 % Turn-on delay time Full Resistive load 2 ms Rise time (0.1~0.9) of Vout 1.5 ms Temperature coefficient ±0.02 %/oC Ripple & Noise At 20MHz Bandwidth 50 m Vp-p Load transient voltage 160 mV Setting time Vout < 10% Peak Deviation 50 μs Maximum capacitive load Min ESR >10mΩ 5000 μF General Specifications Parameters Conditions Typical Maximum Units Switching frequency 100% load 300 KHz Operating temperature -40 to +85 oC Storage temperature -55 to +125 oC Cooling Free air convection Humidity 10 ~ 90 % Weight 7 g MTBF > 5,000,000hrs, Bellcore TR332, 25 oC NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified.
- POL delivering 10A output current • Output Over current protection
- Programmable output voltage • Over temperature protection
- Remote output sense • Operating temperature -40 to 85ºC
- Remote On/Off Control Function • Industry standard SMD footprint
Up to 50 Watt | DC-DC Converter www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 055e R3.C 2 of 9 North America only Pin Out Specifications Dimensions Voltage Adjustment Typical Application: With not using a Control function: Pin Single 1 +V Input
2 On/Off Control
3 Sense
4 Trim
6 GND
Vout (VDC) R trim value in KΩ for 3~5.5V Vin (VDC) R trim value in KΩ for 10~14V Vin (VDC)
0.75 Open Open
1.0 80.6 41.2 1.2 42.2 22.6 1.5 23.2 13 1.8 15 9.09 2.0 11.8 7.32 2.5 6.98 4.99 3.3 3.16 3.09 5.0 2.21 1.47
Up to 50 Watt | DC-DC Converter www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 055e R3.C 3 of 9 North America only With using a Control option: Output ripple and Noise Measurement – test set up: Note: This test set up configuration for measuring the output voltage ripple and the reflected input ripple current is using C1 and C3 tantalum capacitors with ESR<150mΩ and C2 and C4 ceramic capacitors. Efficiency curves versus load current, at 3 ~ 5.5V input for each output voltage setting (25˚C): V o u t 0 . 7 5 V : V o u t 1 V :
Up to 50 Watt | DC-DC Converter www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 055e R3.C 4 of 9 North America only Efficiency curves versus load current, at 3 ~ 5.5V input for each output voltage setting (25˚C): (continued): Vout 1.2V Vout 1.5V V o u t 1 . 8 V V o u t 2 V Vout 2.5V Vout 3.3V
Up to 50 Watt | DC-DC Converter www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 055e R3.C 5 of 9 North America only Derating curve at 3 ~ 5.5V input: Output Power (%) V o u t 1 . 8 , 2 V Output Power (%)
Up to 50 Watt | DC-DC Converter www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 055e R3.C 6 of 9 North America only V o u t 2 . 5 , 3 . 3 V Output Power (%) Efficiency curves versus load current, at 10 ~ 14V input for each output voltage setting (25˚C): V o u t 0 . 7 5 V : V o u t 1 V : Vout 1.2V Vout 1.5V
Up to 50 Watt | DC-DC Converter www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 055e R3.C 7 of 9 North America only Efficiency curves versus load current, at 10 ~ 14V input for each output voltage setting (25˚C) (continued): V o u t 1 . 8 V V o u t 2 V Vout 2.5V Vout 3.3V Vout 5V
Up to 50 Watt | DC-DC Converter www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 055e R3.C 8 of 9 North America only Derating curve at 10 ~ 14V input: Vout 1.8, 2, 2.5V 20 30 40 50 60 70 80 90 100 Safe Operating Area Ambient Temperature º C A B C C
2.0 M/S
70 Cº B
1.5 M/S
70 Cº A
1.0 M/S
60 º C
Up to 50 Watt | DC-DC Converter www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 055e R3.C 9 of 9 North America only Derating curve at 10 ~ 14V input (continued): Vout 3.3, 5V Output Power (%) NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified.5..Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 5. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet.