(PASSIVE INFRARED TYPE) AMP Series Motion-Detecting Sensor (AMP)

ORDERING INFORMATION

FEATURES

  • Detects even slight motion of a per- son (e.g. a 20 cm 7.87 inchmove- ment of the hand) With our unique motion detector—high- ly sensitive type, even slight motions made by people will be detected easily.
  • Compact lens We have decreased the exposed por- tion of the lens, and at the same time maintained a detection ability that is as good or better than other motion sen- sors on the market. Lens dimensions: Standard sensitive type
  • 20 mm .630·.787 inch TYPES PERFORMANCE Highly sensitive type 24·24 mm .945·.945 inch
  • High detection ability This sensor is a stable, sensitive sensor that detects 2°C 3.6°Ftemperature changes regardless of the location or speed of the subject. In other words, this sensor ensures detection whether a person is at the edge of the detection area or in the middle, regardless of how fast they are moving.
  • Low current consumption The standard model consumes 260 µA (during stand-by), while the low con- sumption current type consumes 30 µA (during stand-by). This makes battery operation possible.
  • Wide operation voltage range (2.6 to

5.5 V DC)

The usable range extends from a standard 5 V DC for microcomputers to 3 V DC and 4.5 V DC for battery opera- tion.

  • Varied operation in accordance with the surrouding brightness If used together with a brightness sensor (CdS), you can make the sensor operate only during bright hours or dark hours.
  • Output time can easily be changed By simply changing the resistor attached to the outside of the sensor, the output time can be changed from approximately 10 seconds to 6 minutes.
  • Lighting and ventilation control of con- ference rooms
  • Control of illumination and exhaust fans in toilets
  • Lighting control of halls
  • Nighttime lighting control of vending machines
  • Lightning control around cash dispens- ing machines (ATMs) Detection performance Current consumption Lead wire Operating voltage 1: Standard sensitive type: 0.3 to 2.0 m/s 2: Highly sensitive type: 0.3 to 1.0 m/s 0: Standard type 1: Low current consumption type 0: No lead wire type 9: 2.6 to 5.5 V DC Ex. AMP Detection performance Standard sensitive type Highly sensitive type Current consumption Standard type Low current consumption type Standard type Low current consumption type Rated operating voltage 2.6 to 5.5 V DC Part No. AMP1009 AMP1109 AMP2009 AMP2109 Packing quantity Inner Outer 20 pcs. 200 pcs. 1. Detection performance (Measuring conditions: ambient temp.: 25°C 77°F; operating voltage: 5V DC) 2. Absolute maximum rating (Measuring condition: ambient temp.: 25°C 77°F) Items Rated detection distance Detection range Horizontal Vertical Detection zone Standard sensitive type 5 m min. 95° 55° 34 zones Highly sensitive type 2 m min. 73° 73° 64 zones Conditions of objects to be detected 1. To have more than 2°C 36°F of temperature 1. difference from background 2. Movement speed
  • Standard sensitive type: 0.3 to 2.0 m/s
  • Highly sensitive type: 0.3 to 1.0 m/s 3. Detection object = human body Items Power supply voltage Output (Open collector) Voltage Usable ambient temperature Storage temperature Specified value 7 V 30 V Current 50 mA –20 to +55°C –4 to +131°F –30 to +80°C –22 to +176°F No freezing and condensing at low temperature. Remarks AMP series 2002.10.23 7:57 PM Page 10

9.843ft 6.562 3.281 0–1 –3.281 –6.562 –9.843 –4m –13.123ft 3.281 6.562 9.843 13.123ft –3.281 –6.562 –3m –9.843ft X 47° 25.4° 47° 16.404ft X Y 16.404ft 2.5m 8.202ft 2.5m 8.202ft 16.404ft 16.404ft 2.5m 8.202ft 2.5m 8.202ft 25.4° 28.7° –28.7° 0° 0° TOP VIEW SIDE VIEW 3. Electrical characteristics (Measuring conditions: ambient temp.: 25°C 77°F; operating voltage: 5V) Items Rated operating voltage Rated consumption current Mask time* Circuit stability time Timer time Standby ON Minimum Typical Maximum Minimum Typical Maximum Minimum Typical Maximum Minimum Typical Maximum Minimum Typical Maximum Minimum Typical Maximum Sym- bol V dd Iw Ia Tm Twu Td Specified value Measured conditions

2.6 V DC

5.5 V DC

Standard type: 200 µA; Low consumption current type: 12 µA Standard type: 260 µA; Low consumption current type: 30 µA Standard type: 560 µA; Low consumption current type: 96 µA Standard type: 1,000 µA; Low consumption current type: 1,000 µA Standard type: 1,250 µA; Low consumption current type: 1,200 µA Standard type: 1,600 µA; Low consumption current type: 1,400 µA 0.8 s 1.3 s 1.8 s 15 s 30 s 45 s 5 s 10 s 15 s When power is ON. Externally mounted resistor R set to 0 kΩ DETECTION PERFORMANCE 1. Standard sensitive type [Timing chart] Top view Side view Motion-Detecting Sensor (AMP) AMP series 2002.10.23 7:57 PM Page 11

DataSheet4U.com 1.5m 4.921ft 3.281ft 6.562ft 3.281 0.5 1.640 –0.5 –1.640 –3.281 –1.5m –4.921ft 3.281ft 6.562ft 31.2° X –31.2° 11.1° –11.1° 1.5m 4.921ft 3.281ft 6.562ft 3.281 0.5 1.640 –0.5 –1.640 –3.281 –1.5m –4.921ft 3.281ft 6.562ft 31.2° Y –31.2° 11.1° –11.1° X-Y cross section Y X 0.5 1.640 –0.5 –1.640 1.5m 4.921ft –1.5m –4.921ft 0 0.5 1.640 –0.5 –1.640 –3.281 –1.5m –4.921ft 3.281 1.5m 4.921ft HO W TO USE Top view Side view 1. Wiring diagram 2. Highly sensitive type 2. Time setting Standard sensitive type/Highly sensitive type Timer time and external mounted resistor 3. Installation Install the sensor so that people will be enter- ing from the X or Y direction shown below. If persons approch the sensor from the Z direc- tion, detection distance will be shortened. Time calculation: Td = 0.3465·(20+R) R: External mounted resistor (KΩ ) Sensor module Motion-Detecting Sensor (AMP) DIMENSIONS mm inch 1. Standard sensitive type 2. Highly sensitive type 43.5 1.713 4-2.5 dia. 4-.098 dia. 22.5 .886 .787 .630 35.8 1.409 14.0 .551 1.6±0.3 .063±.012 1.102 26.8 1.055 1.929 43.5 1.713 4-2.5 dia. 4-.098 dia. 21.6 .850 17.6 .693 8.5 .335 R11.3 .445 R14.1 .555 11.25 .44322.5 .886 43.5 1.713 4-2.5 dia. 4-.098 dia. 22.5 .886 43.5 1.71318.3 .720 22.5 .886 .945 26.8 1.055 .945 18.4 .724 1.6 .063 1.102 25.6 1.008 25.6 1.008 18.3 .720 7.0 .276 11.25 .443 3.4±0.3 .134±.012 35.8 1.409 1.929 4-2.5 dia. 4-.098 dia. 15.3 .602 General tolerance: ±0.4 ±.016 General tolerance: ±0.4 ±.016 Note 1: In order to ensure proper detection, install it with the lens exposed at least 8.5 mm .335 inch. Note 2: In order to ensure proper detection, install it with the lens exposed at least 7.0 mm .276 inch. 3.4±0.3 .134±.012 Timer time (Td) 10 sec. 8.86 KW Short 30 sec. 66.6 KW 68 KW 1 min. 153.2 KW 160 KW 2 min. 326.3 KW 330 KW 3 min. 499.5 KW 510 KW 4 min. 672.6 KW 680 KW 5 min. 845.8 KW 820 KW 6 min. 1,019 KW 1 MW R-value External mounted resistor Note Timer time, 1 sec. is available as a custom ordered product. Load power source Sensor power source 15.3 .602 AMP series 2002.10.23 7:57 PM Page 12

This product is mainly designed for use indoors with general electronic devices. If it is to be used outdoors, take suitable precautions to protect it from water, dust, dew condensation, and freezing. Example: 1. Safety devices 2. Security equipment 3. Traffic signal equipment 4. Miscellaneous safety devices and control equipment for trains, automobiles. 1. Operation environment 1) Shown below are ambient tempera- ture, humidity and air pressure condi- tions for operation, transportation, and storage of the sensor. a Usable ambient temperature: –20 to 55°C –4 to +131°F a Storage temperature: –30 to 80°C –22 to +176°F b Humidity: 15 to 85% R.H. (with no freezing and condensation) c Air pressure: 86 to 106 kPa

  • Condensation Condensation may occur if the relay is exposed to sudden temperature change in a high-temperature, high- humidity environment. This may result in problems such as sensing performance deterioration, non- operation or insulation failure.
  • Freezing At temperature below 0°C 32°F, con- densation and moisture may freeze onto the sensor and cause problems such as sensing performance deterioration, non-operation or insula- tion failure.
  • Low-temperature, low-humidity atmosphere If the relay is exposed to a low- temperature, low-humidity environ- ment for an extended period of time, the plastic components may become brittle and fragile. 2) Be sure to use a stable power source for the sensor. The sensor may operate incorrectly if it receives voltage ripples of more than 40 mV P-P. 3) Be sure to employ an absorber ele- ment to prevent the internal circuit from being destroyed if an external voltage surge of more than 500 V occurs (mono- polarized all-wave voltage of ±1.2·50 µsec). 4) Static electricity or lightning may cause the sensor to operate incorrectly. 5) Avoid using the sensor in the following locations: a Locations exposed to direct sunlight or other bright light sources. b Locations where a heater lies within the detection range. c Locations subject to direct air from an air conditioner. d Locations with high humidity (e.g., bathrooms, etc.). e Locations subject to sudden, extreme temperature changes. f Locations subject to strong vibrations or shocks. g Locations containing objects that block infra-red rays such as glass. h Locations where blinds or curtains are located near the detection range. i Locations near to a heat source or switching device. j Locations containing dust or corrosive gases. k Outdoors. 2. Detection characteristics 1) Since this sensor works by detecting fluctuations in infrared rays, it will also detect non-human heat sources (e.g., small animals, etc.) if they enter the detection range. 2) Since this sensor works by detecting fluctuations in infra-red rays, it will not detect a person that is motionless, even if within the detection range. 3. Drop damage If the sensor is dropped, damage can occur resulting in incorrect operation. If dropped, be sure to do a visual check of the exterior for noticeable damage and check the operation characteristics for faulty operation. 4. Other handling cautions 1) When installing the sensor, be sure not to apply stress to the printed circuit board. 2) Be careful not to allow dust or dirt to accumulate on the lens as this will adver- sely affect the detection sensitivity. 3) When soldering the lead wire, perform the operation within 3 seconds at 350°C 662°F. 4) In order to avoid adverse effects from noise, we recommend the use of shielded wire when wiring. 5) In order to protect the internal cir- cuitry, keep wire to a length of 1 m 3.3 ft maximum from the sphere. Motion-Detecting Sensor (AMP) AMP series 2002.10.23 7:57 PM Page 13 12/1/2002 All Rights Reserved, © Copyright Matsushita Electric Works, Ltd. Go To Online Catalog