ORDERING INFORMATION
1: Digital output 2: Analog output Detection performance 1: Standard detection type 2: Slight motion detection type 3: Spot detection type 4: 10m detection type Feature 1: PC board mounting type Operating voltage 1: 5V DC Lens color 1: Black 2: White
FEATURES
- The world’s smallest with a built-in amplifier Extremely compact. Ideal for use in miniaturized devices. 2. Dual lens colors (white and black) are provided With an ultrasmall design and dual lens colors (white and black), it is inconspicu- ous, allowing the user to select either white or black to match the equipment color. This provides greater flexibility in equipment design. 3. Both digital output and analog out- put (with adjustable sensitivity) are available. 4. Built-in amplifier for easy use Has a built-in amplifier, and can be con- nected directly to a microcomputer.
- Block diagram of the digital output circuit
- Block diagram of the analog output circuit 5. Detects even slight motion of a per- son With our sensor, even slight motions made by people will be detected easily.
- Fine motion detection capability within approximately 2 meters of sensor. Standard type: Detects movement of approximately 30cm 11.811inch. Slight motion detection type: Detects movement of approximately 20cm 7.874inch. 6. Noise withstanding capability Circuitry is contained in a TO5 metal package, providing at least twice the noise withstanding capability as conven- tional type.
- Comparison example of noise withstand- ing capability
APPLICATIONS
- Home appliances Useful for saving energy in air conditioner, television, personal computer, or ventilator and air purifier 2. Amusement machine market Useful for saving energy and for automated guidance in theme parks and large video games 3. Equipment in service market Useful for automated guidance, automated announcements and energy saving in vending machines, ATMs, etc. 4. Lighting market Automated on/off controls, etc. for lamps, desk lamps, indoor lights, halls, stairway lights, etc. Distance at which motion sensor is not affected by cellular phone noise Conventional type Min. 1 to 2m 3.281 to 6.562ft MP Motion Sensor Min. 1 to 2cm .394 to .787inch Movement Sensor Infrared radiation Temperature difference Infrared radiation What is passive infrared type? This sensor detects changes in infrared radiation which occur when there is movement by a person (or object) which is different in temperature from the surroundings. Q As this sensor detects temperature differences, it is well suited to detecting the motion of people by their body temperature. W Wide sensing area. Vdd Output Single-chip IC TO5 metal package (9.8mm × 9mm .386inch × .354inch dia.) Gnd Stabilized power supply Amplifier circuit Comparator output circuit Quad type PIR element Multi lens Optical filter Infrared radiation Vdd Output Single-chip IC TO5 metal package (9.8mm × 9mm .386inch × .354inch dia.) Gnd Stabilized power supply Amplifier circuit Quad type PIR element Multi lens Optical filter Infrared radiation Standard type Slight motion detection type Spot type 10 m detection type MOTION SENSOR (PASSIVE INFRARED TYPE) MP MOTION SENSOR MP Motion Sensor (AMN1) NaPiOn web page URL: http://www.napion.com/
- Digital output 2. Analog output PERFORMANCE 1. Detection performance 2. Rating (Measuring condition: ambient temp. = 25°C 77°F) (Common to All types) 3. Electrical characteristics (Measuring condition: ambient temp. = 25°C 77°F; operating voltage = 5V) (Common to All types) 1) Digital output Rated operating voltage Items Items Items Symbol Specified value Measured conditions Reted operating voltage Minimum Typical Maximum Vdd
3.0 V DC
6.0 V DC
(Standby) *Remark Typical Maximum Iw 170 µA 300 µA Iout = 0 Output (when detecting) Current Maximum Iout 100 µA Vout 7Vdd–0.5 Voltage Minimum Maximum Vout Vdd –5 Vdd (Same as operating voltage) Open when not detect- ing Circuit stability time Typical Maximum Twu 7 s 30 s Specified value Remarks Power supply voltage –0.3 to 7 V DC Usable ambient temperature –20 to 60°C –4 to +140°F No freezing and condensing at low temperature. Storage temperature –20 to 70°C –4 to +158°F Standard detection type Slight motion detection type Conditions of objects to be detected Rated detection distance* Remark 1 Detection range 5m 16.404ft (Max.) 2m 6.562ft (Max.) 1. Detectable difference in temperature between the target and background for the spot type is more than 4°C 39.2°F. 2. Movement speed
- Standard detection type/Spot detection type/ 10m detection type: 1.0 m/s
- Slight motion detection type: 0.5 m/s 3. Detection object = human body (size is 700mm × 250mm 27.559inch × 9.843inch, but for the slight motion detection type the size is 200mm × 200mm 7.874inch × 7.874inch) Horizontal*Remark 2 100° 91° Vertical*Remark 2 82° 91° Detection zone*Remark 3 64 zones 104 zones Spot detection type 10m detection type 5m 16.404ft (Max.) 10m 32.808ft (Max.) 38° 110° 22° 93° 24 zones 80 zones Detection performance Ambient temperature Lens color Part No. Packing quantity Inner 50 pcs. 1,000 pcs. Outer 3 to 6 V DC Standard detection type –20 to +60°C –4 to +140°F Black AMN11111 White AMN11112 Slight motion detection type Spot detection type 10m detection type Black AMN12111 White AMN12112 Black AMN13111 White AMN13112 Black AMN14111 White AMN14112 Rated operating voltage Detection performance Ambient temperature Lens color Part No. Packing quantity Inner 50 pcs. 1,000 pcs. Outer 4.5 to 5.5 V DC Standard detection type –20 to +60°C –4 to +140°F Black AMN21111 White AMN21112 Slight motion detection type Spot detection type 10m detection type Black AMN22111 White AMN22112 Black AMN23111 White AMN23112 Black AMN24111 White AMN24112 2. *Remarks1. Depending on the difference in temperature between the background and detection target and the speed at which the target moves, these sensors may be capable of detection beyond the detection distances stated above. Nevertheless, they should be used within the prescribed detection distances. For further details, refer to the detection range diagram on page 7. 3. Regarding of detection zone, please refer to “DETECTION PERFORMANCE” on page 7. Remark: The current which is consumed during detection consists of the standby consumed current plus the output current. Vertical Horizontal (Standard detection/ Slight motion detection type) (Spot detection type/ 10 m detection type) Cut out Vertical Horizontal Cut out MP Motion Sensor (AMN1)
Remark: Circuit stability time: 45s max. (45s max. for the 10m detection type) While the circuitry is stabilizing after the power is turned on, the sensor output is not fixed in the “on” state or “off” state. This is true regardless of whether or not the sensor has detected anything. [Timing chart] 1) Digital output ON OFF Power supply Detection state ON OFF Detect Not detect Sensor output Circuit stability time 2) Analog output Items Symbol Specified value Measured conditions Reted operating voltage Minimum Maximum Vdd 4.5 V DC
5.5 V DC
2.5 V Vdd Output offset average voltage Minimum Typical Maximum Voff 2.3 V 2.5 V 2.7 V Steady-state output voltage when not detecting Reted consumption current Typical Maximum Iw 0.17 mA 0.3 mA Iout = 0 Steady-state noise Typical Maximum Vn 130 m Vp-p 300 m Vp-p Output current Maximum Iout 50 µA Circuit stability time Typical Maximum Twu 7 s 45 s Remark: Circuit stability time: 30s max. While the circuitry is stabilizing after the power is turned on, the sensor output is not fixed in the “on” state or “off” state. This is true regardless of whether or not the sensor has detected anything. 2) Analog output Vdd GND (Comparator decision output) Vdd Voff V h V n V l GND Circuit stability time Body movement Threshold voltage 1 (comparator) Threshold voltage 2 (comparator) Power supply Detection state Detect Not detect Output waveform V out MP Motion Sensor (AMN1)
MP Motion Sensor (AMN1) DETECTION PERFORMANCE 1. Standard detection type X-Y cross section 2. Slight motion detection type X5m 16.404ft 16.404ft 2.5m 8.202ft 2.5m 8.202ft 50° 50° TOP VIEW 3.281ft 1.5 4.921 6.562 2.5m 8.202ft –1.5 –4.921 –6.562 –2.5m –8.202ft 3.281 0.5 1.640 –0.5 –1.640 –3.281 6.562ft Y 46° 46° 0°1m 2m 3.281ft 6.562ft Y5m 16.404ft 16.404ft 2.5m 8.202ft 2.5m 8.202ft 41° 41° SIDE VIEW Y Detection zone 3.281 (Max. 7.42m) (Max. 24.344ft) (Max. 5.66m) (Max. 18.570ft) X 6.562 6.562 9.843 9.843 13.123ft 13.123ft 3.281 3.281 3.281 6.562 6.562 9.843ft 9.843ft X-Y cross sectionY Detection zone X –0.5 –1.640 –0.5 –1.640 –3.281 –1.5 –4.921 –6.562 0.5 1.640 0.5 1.640 3.281 1.5 4.921 6.562 –3.281 3.281 –1.5 –4.921 1.5 4.921 –6.562 6.562–2.5m –8.202ft 2.5m 8.202ft –2.5m –8.202ft 2.5m 8.202ft (Max. 5m dia.) (Max. 16.404ft dia.) Remarks: 1. The X-Y cross-sectional diagram shows the detection area. 2. The differences in the detection zone patterns are indicative of the projec- tions of the 16 lenses with single focal point and with five optical axes. An object whose temperature differs from the background temperature and which crosses inside the detection zone will be detected. Remarks: 1. The X-Y cross-sectional diagram shows the detection area. 2. The differences in the detection zone patterns are indicative of the projections of the 26 lenses with single focal point and with three optical axes. An object whose temperature differs from the background temperature and which crosses inside the detection zone will be detected.
MP Motion Sensor (AMN1) 3. Spot detection type 4. 10m detection type 5. Notes regarding the detection zone The detection zone has the polarity shown in the diagram on the right. When targets enter both the + and – zones with the same timing, the signals are cancelled each other, thus in this case there is a possibility that the object cannot be detected at the maximum specified detection distance. X-Y cross section X-Y cross section TOP VIEW 5.562ft 1.25 4.101 2.5m 8.202ft 2.5 8.202 1.25 4.101 16.404ft X 19° 19° 0°2.5 8.202 16.404ft TOP VIEW 55° 16.404ft 10m 32.808ft 16.404ft 10m 32.808ft X SIDE VIEW 46.5° Y 16.404ft 10m 32.808ft 16.404ft 10m 32.808ft Detection zone 13.123 19.685 13.123 Y X 19.685ft 19.685ft (15.9m 52.165ft) 13.123 13.123 6.562 6.562 26.247 10m 32.808ft 19.685 26.247 10m 32.808ft 6.562 6.562 (12.3m 40.354ft) SIDE VIEW Y 11° 11° 5.562ft 1.25 4.101 2.5m 8.202ft 2.5 8.202 1.25 4.101 16.404ft 2.5 8.202 16.404ft Y X 3.281ft 3.281ft (Max. 2m) (Max. 6.562ft) (Max. 1.4m) (Max. 4.593ft) 0.5 1.640 0.5 1.640 0.5 1.640 0.5 1.640 3.281ft 3.281ft Remarks: 1. The X-Y cross-sectional diagram shows the detection area. 2. The differences in the detection zone patterns are indicative of the projections of the 6 lenses with single focal point and with two optical axes. An object whose temperature differs from the background temperature and which crosses inside the detection zone will be detected. Remarks: 1. The X-Y cross-sectional diagram shows the detection area. 2. The differences in the detection zone patterns are indicative of the projec- tions of the 20 lenses with single focal point and with five optical axes. An object whose temperature differs from the background temperature and which crosses inside the detection zone will be detected. Detection zone Target
MP Motion Sensor (AMN1) HOW TO USE 1. Wiring diagram 1) Digital output 2. Timer circuit example 1) Digital output Vdd GND Out Iout: Max.100 µA Sensor Load Vdd: Input power source (DC) GND: GND Out: Output (Comparator) 2) Analog output Vdd GND Out Sensor Microcomputer, A/D converter etc. GND The transistor turns on when the sensor detects something Select a transistor to match the relayTimer IC Timer time = RXC Connection to motion sensor Relay Input voltage Vdd10 µ ++ 10 µ 0.1 µ 0.1 µ 0.1 µ 0.1 µ 0.1 µ Out GND 10k 1113 16 1 47k 47 µ (5VDC) C R REG 74HC 123 3. Installation Install the sensor so that people will be entering from the X or Y direc- tion shown below. If persons approch the sensor from the Z direction, detection distance will be shortened. Y direction ❍ X direction ❍ X direction ❍ Z direction ∆ Z Note: This is the reference circuit which drives the MP motion sensor. Install a noise filter for applications requiring enhanced detection reliability and noise withstanding capability. Differences in the specifications of electronic components to which the units are connected sometimes affect their correct operation; please check the units' performance and reliability for each application. 2) Analog output ++Input voltage GND Vdd10 µ 0.1 µ Out Connection to motion sensor GND 0.1 µ 0.1 µ Relay 47 µ (5VDC) REG Timer IC Window comparator Select a transistor to match the relay The transistor turns on when the sensor detects something Timer time = RXC +10 µ 0.1 µ 0.1 µ 10k 1113 16 1 47k C R 74HC 123 Note: This circuit is a sample of a drive circuit for the MP Motion Sensor. Its noise resistance and long-term reliability are not considered or investigat- ed. To improve the detection reliability and noise resistance of the circuit, consider adding a noise filter. Matsushita Electric Works, Ltd. accepts no responsibility for damages resulting from the use of this circuit.
MP Motion Sensor (AMN1) DIMENSIONS mm inch General tolerance ±0.5 ±.020 1. Standard detection type 45°±4° 45°±4° Vdd OUT GND .200±.008 dia. .433 11 .571 14.5 4.5 .177 .433 dia. 11 dia. .374 dia. 9.5 dia. .018±.002 dia. 0.45±0.05 dia. Notes 3) Molding gate .138 3.5 Note 1) 5.08 ±0.1 dia. .200 ±.004 dia. Note 2) 11.0 .433 Sensing area 45° +0.10 +.0040 10 dia.+0.2 .394 dia.+.008 Recommended PC board pattern (BOTTOM VIEW) Notes: 1. In order to ensure proper detection, install it with the lens exposed at least 3.5mm .138inch. 2. As for panel mounting hole, tapering or making a large size hole should be done. 3. The height dimension does not include the remain- ing molding gate. 2. Slight motion detection type 45°±4° 45°±4° Vdd OUT GND .200±.008 dia. 4.5 .177 8.9 .350 15.2 .59812.8 .504 .018±.002 dia. 0.45±0.05 dia. 12.7 dia. .500 dia. 11 dia. .433 dia. 11.9 dia. .469 dia.7.4 dia. .291 dia. Note 3) Molding gate Note 2) 12.8 .504 2.4 .094 Sensing area Note 1) 12.4 dia.+0.2 .488 dia.+.008 5.08 ±0.1 dia. .200 ±.004 dia. 3-0.65 dia.3-.026 dia. +0.10 +.0040 45° 45° Recommended PC board pattern (BOTTOM VIEW) Notes: 1. In order to ensure proper detection, install it with the lens exposed at least 2.4mm .094inch. 2. As for panel mounting hole, tapering or making a large size hole should be done. 3. The height dimension does not include the remaining molding gate.
- Checkpoints relating to principle of operation MP motion sensors are passive infrared sensors which detect changes in the infrared rays. They may fail to detect successfully if a heat source other than a human being is detected or if there are no temperature changes in or movement of a heat source. Care must generally be taken in the following cases. The perfor- mance and reliability of the sensors must be checked out under conditions of actu- al use. <1> Cases where a heat source other than a human being is detected. 1) When a small animal enters the detec- tion range. 2) When the sensor is directly exposed to sunlight, a vehicle’s headlights, an incandescent light or some other source of far infrared rays. 3) When the temperature inside the detection range has changed suddenly due to the entry of cold or warm air from an air-conditioning or heating unit, water vapor from a humidifier, etc. <2> Cases where it is difficult to detect the heat source 1) When an object made of glass, acrylic or other subject which far infrared rays have difficulty passing through is located between the sensor and what is to be detected. 2) When the heat source inside the detection range hardly moves or when it moves at high speed; for details on the movement speed, refer to the section on the performance ratings. 2. When the detection area becomes larger When the difference between the ambi- ent temperature and body temperature is large (more than 20°C 68°F), detection may occur in isolated areas outside the specified detection range. 3. Other handling cautions 1) Be careful not to allow dust or dirt to accumulate on the lens as this will adversely affect the detection sensitivity. 2) The lens is made of a soft material (polyethylene). Avoid applying a load or impact since this will deform or scratch the lens, mak- ing proper operation impossible and causing a deterioration in its perfor- mance. 3) The sensor may be damaged if it is exposed to static with a voltage exceed- ing ±200V. Therefore, do not touch its terminals directly, and exercise adequate care in the handling of the sensor. 4) When the leads are to be soldered, solder them by hand for less than 3 sec- onds at a temperature of less than 350°C 662°F at the tip of the soldering iron. Avoid using a solder bath since this will causing a deterioration in the sensor’s performance. 5) Do not attempt to clean the sensor. Cleaning fluid may enter inside the lens area causing a deterioration in perfor- mance. 6) When using the sensors with cables, it is recommended that cables which are shielded and as short as possible be used in order to safeguard against the effects of noise. For the general precautions, refer to the Notes for Motion Sensors on page 24. 3. Spot detection type 4. 10m detection type Recommended PC board pattern (BOTTOM VIEW) Notes: 1. In order to ensure proper detection, install it with the lens exposed at least 5.6mm .220inch. 2. As for panel mounting hole, tapering or making a large size hole should be done. 3. The height dimension does not include the remaining mold- ing gate. Notes: 1. As for panel mounting hole, tapering or making a large size hole should be done. 2. The height dimension does not include the remaining molding gate. MP Motion Sensor (AMN) mm inch General tolerance ±0.5 ±.020 8.9 dia. .350 dia. .433 ±0.05 0.45 dia. ±.002 .018 dia. 15.1 .594 4.5 .177 GNDOUT Vdd ±0.2 ±.008 .200 dia. ±4° 45°45°±4° Note 2)Molding gate 9.4 dia. +0.2 .370 dia. +.008 Note 1) 45° 3-0.65 dia. ±.004 .200 dia. ±0.1 5.08 dia. +0.1 3-.026 dia.-0 +.004 Recommended PC board pattern (BOTTOM VIEW) Note 3)17.0 dia. .670 dia. 17.4 dia. .685 dia. 18.53 .730 4.5 .177 8.6 .339 11 dia. .433 dia. ±0.05 0.45 dia. ±.002 .018 dia. GNDOUT Vdd ±0.2 ±.008 .200 dia. ±4° 45°45°±4° Molding gate Note 2) .705 dia.-0 +.008 17.9 dia.-0 +0.2 12.9 .508 45° 3-0.65 dia. ±.004 .200 dia. ±0.1 5.08 dia. +0.1 3-.026 dia. +.004 5.6 Note 1) Sensing area
Electric Works, Ltd. Automation Controls Group Europe Matsushita Electric Works Copyright © 2001 • Printed in Germany Please contact our Global Sales Companies in: Europe /L50298Austria Matsushita Electric Works Austria GmbH Stojanstraße 12, A-2344 Maria Enzersdorf, Tel. (0 22 36) 2 68 46, Fax (0 22 36) 4 61 33, http://www.matsushita.at /L50298Germany Matsushita Electric Works Rudolf-Diesel-Ring 2, D-83607 Holzkirchen, Tel. (08024) 648-0, Fax (08024) 648-555, http://www.matsushita.de /L50298Ireland Matsushita Electric Works UK Ltd. Irish Branch Office, Waverley, Old Naas Road, Bluebell, Dublin 12, Republic of Ireland, Tel: (01) 4600969, Fax: (01) 4601131 /L50298Portugal Matsushita Electric Works España S.A. Portuguese Branch Office, Avda 25 de Abril, Edificio Alvorada 5-ºE, 2750-512 Cascais, Portugal, Tel. (21) 4828266, Fax (21) 4827421 /L50298Scandinavia Matsushita Electric Works Scandinavia AB Sjöä ngsvä gen 10, 19272 Sollentuna, Sweden, Tel. (08) 59476680, Fax (08) 59476690 /L50298Spain Matsushita Electric Works Espa ñ a S.A. Barajas Park, San Severo 20, E-28042 Madrid, Tel. (91) 3293875, Fax (91) 3292976 /L50298Switzerland Matsushita Electric Works Schweiz AG Grundstrasse 8, CH-6343 Rotkreuz, Tel. (041) 7997050, Fax (041) 7997055, http://www.matsushita.ch North & South America Asia /L50298China Matsushita Electric Works Ltd. China Office 2013, Beijing Fortune, Building No. 5, Dong San Huan Bei Lu, Chaoyang District, Beijing, Tel. 86-10-6590-8646, Fax 86-10-6590-8 647 /L50298Hong Kong Matsushita Electric Works Ltd. Hong Kong Rm1601, 16/F, Tower 2, The Gateway, 25 Canton Road, Tsimshatsui, Kowloon, Hong Kong, Tel. (852) 2956-3118, Fax (852) 2956-0398 Automation Controls Group /L50298Singapore Matsushita Electric Works Pte. Ltd. (Asia Pacific) 101 Thompson Road, #25-03/05, United Square, Singapore 307591, Tel. (65) 255-5473, Fax (65) 253-5689 Matsushita Electric Works