AMLDW-6070-RZ AIMTEC | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 3
Technical content
Up to 1000mA | LED Driver www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12.C 1 of 3 North America only FEATURES: Models Single output Model Input Voltage (V) Output Voltage (V) Maximum Rated Current (mA) Max Capacitive Load (uF) Efficiency (%) Ripple & Noise (mV p-p) AMLDW-6030-RZ 9-60 2-56 300 2.2 97 250 AMLDW-6035-RZ 9-60 2-56 350 2.2 97 300 AMLDW-6050-RZ 9-60 2-56 500 2.2 97 350 AMLDW-6060-RZ 9-60 2-56 600 2.2 97 400 AMLDW-6070-RZ 9-60 2-56 700 2.2 97 400 AMLDW-60100-RZ 9-60 2-56 1000 2.2 97 450 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Nominal Typical Maximum Units Voltage range 48 9-60 VDC Filter Capacitor Absolute Maximum Rating 65 VDC Peak Input Voltage time 500 ms DC/DC ON (Leave open if not used) ON –Open or 2.5V< Vadj <5V DC/DC OFF (or short pins 2,3,4) OFF(shutdown) – Vadj <0.8 Maximum Remote pin drive current Vadj = 0 - 5V <1 mA Quiescent Current in Shutdown mode Vin = 60V 3 mA On/Off Control (Digital Control) Max PWM Frequency 1KHz Output current adjustment 1 to 100 % Output Specifications Parameters Conditions Typical Maximum Units Current accuracy ±5 % Output Voltage range V input = 60V 2-56 VDC Output current Vin – Vout > 4V Short Circuit protection Regulated at the rated current for each model Temperature coefficient ±0.03 %/oC General Specifications Parameters Conditions Typical Maximum Units Switching frequency 100% load 40-1000 KHz Operating temperature See derating chart -40 to +85 oC Storage temperature -40 to +125 oC Maximum case temperature 105 oC Thermal Impedance Free air convection +30 oC/W Cooling Free air convection Humidity 95 % RH Case material Non-Conductive Black Plastic (UL94V-0 rated) Weight 17.7 g MTBF > 2 000 000hrs (MIL-HDBK-217 F at +25 oC) Maximum Soldering Temperature 1.5 mm from case for 10sec. 260 oC NOTES: 1. Reversed polarity at the input power will damage the driver. The input ground must not be connected to the negative output. 2. Maximum output open voltage is equal to input voltage.
- Step Down DC/DC LED driver • Operating Temperature range -40ºC to +85ºC
- Constant current output • Open and Short LED Protection
- Ultra Wide (7:1) input voltage range • PWM / Digital Voltage dimming
- High efficiency up to 97%
- IP67 Case
- Output power up to 56 Watts Click on Series name for product info on aimtec.com
Up to 1000mA | LED Driver www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12.C 2 of 3 North America only Safety Specifications Parameters Standards CE EN 55015 : 2006+A1 : 2007+A2 : 2009 EN 61547 : 2009 (Designed to meet EN 60950-1) Pin Out Specifications Dimensions 20.32 (0.80) 31.75 (1.25) Bottom View 12.45 (0.49) 20.32 (0.80) 100.00 (3.94) 10.00 (0.39) 1 2 24 12.45 (0.49) 20.32 (0.80) 100.00 (3.94) 10.00 (0.39) 12 13 All Wires are Stripped & Tinned Lead Wires are under the specifications of general lamps: Wire is UL 1015/CSATEM listed #22AWG / 600V / 105ºC Pin Single Description 1(Black) - V Input - DC Supply 2(White) Vadj PWM/ON/OFF or not used 12(Blue) -V Output LED Cathode Connection 13(Yellow) + V Output LED Anode connection 24 (Red) + V Input + DC Supply
Up to 1000mA | LED Driver www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12.C 3 of 3 North America only Derating Free Air Convection - 40 - 20 0 20 40 60 80 100 100 Safe Operating Area Output Power (%) Ambient Temperature º C AMLDW-6050-RZ AMLDW-6060-RZ AMLDW-6070-RZ AMLDW-60100-RZ AMLDW-6030-RZ AMLDW-6035-RZ Typical Application Circuits Vin+ Vin- (or GND) Vadj (PWM / Dim / On / Off) LED Strings14 Vout+ Vout- AIMTEC AMLDW-60xx-RZ PWM NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.