Drain Separator for Vacuum Removes water droplets from air by simply installing in vacuum lines. Prevents damage of vacuum pumps and ejectors. Cleaning water Pad OUT side IN side Drain separator for vacuum 2 port solenoid valve Drain To ejector 1391 SP ZCUK AMJ AMV ZH -X185 Related Equipment AMJ A

Drain Separator for Vacuum Series AMJ RoHS AMJ 30 Body size Thread type Rc G NPT Nil F N Port size Accessory (Option) None Bracket Nil B AMJ3000 200 1/4, 3/8 0.3 AMJ4000 300 3/8, 1/2 0.6 AMJ5000 500 3/4, 1 1.1 Fluid Operating pressure Proof pressure Ambient and fluid temperature Water drop removal ratio Element life Air –100 kPa to 1.0 MPa

1.5 MPa

5 to 60°C 90% 2 years or when pressure drops to 0.02 MPa AMJ3000 AMJ4000 AMJ5000 Semi-standard Drain cock Metal bowl Nylon bowl Drain guide (Rc 1/4)∗ Flow: Right → Left Nil J R AF30P-050AS AF40P-050AS AF50P-050AS Symbol Nil J R Nil 2 6 J R 03 2R Model Recommended flow rate (L/min (ANR)) Port size (Nominal size B) Weight (kg) Applicable model Bracket assembly (With 2 mounting screws) Option Drain cock Metal bow Nylon bowl Drain guide Flow: Right → Left Model Specifications Accessory (Option) Semi-standard/Combinations If ordering two symbols or more, indicate symbols numerically and alphabetically. ∗ Without valve function (It needs drain piping and piping for a stop valve like ball valves, etc.) Over 90% of water droplets can be removed through the use of a special water droplet removing element. The provision of a drain cock makes it possible to dis- charge the drain manually after breaking the vacuum. Even when the element is saturated with water, there is almost no drop in pressure (increase in resistance). The element can be replaced with a single touch. Combination available Combination not available How to Order 1392

0.0001 0.0005 0.001 0.005 0.01 500 1000 AMJ3000 AMJ4000 AMJ5000 Air flow rate (L/min (ANR)) Supply pressure (MPa) OUTIN IN OUT q t w y r e q y r w e Construction Body size Symbol Applicable body size AMJ3000 AMJ4000, 5000 Semi-standard Polycarbonate bowl (1) Metal bowl Nylon bowl (1) Nil Thread type(3) Rc G NPT Nil F N Drain discharge Drain cock Drain guide (Rc 1/4)(2) A J AMJ CA 30 A 2 Note 2) Without valve function (It needs drain piping and piping for a stop valve like ball valves, etc.) Note 1) The bowl assembly includes a bowl guard (Material: Steel strip). Note 3) Select in line with the thread type on the body. Component Parts No. Description Body1 Material Aluminum alloy Note Platinum silver coated Drain Separator for Vacuum Series AMJ How to Order Bowl Assembly Replacement Parts No. Description Element assembly Bowl assembly Note) O-ring O-ring Spacer Material Part no. AMJ3000 AMJ4000 AMJ5000 AMJ-EL3000 AMJ-CA30- C3SFP-260S AMJ-SA001 AMJ-EL4000 AMJ-CA40- C4SFP-260S AMJ-SA002 AMJ-EL5000 AMJ-CA40- C4SFP-260S 111710 AMJ-SA003 Note) • Refer to the above for “How to Order Bowl Assembly”.

  • The spacer y is not included in the bowl assembly. NBR NBR NBR Flow Characteristics Fluid: Air Measured pressure: Downstream release to atmosphere 1393 SP ZCUK AMJ AMV ZH -X185 Related Equipment AMJ

1/4, 3/8 3/8, 1/2 3/4, 1 Model Port size Q 165 (166) 199 (202) 278 (280) 6.5 8.5 10.5 2.3 2.3 3.2 158 (159) 192 (195) 271 (273) A C D With drain guide R Bracket mounting dimensions Note) ( ) is the case for metal bowl. E F G H J K L M (mm) M Maintenance space 40 B P H F D J L A K G EC Drain 2 x port size Q Rc 1/8 Bracket (Option) Vacuum OUTIN R Hexagon width across flats 24 1/4 female thread without valve function C M F Maintenance space 20 H D B E L A G J K Drain 2 x port size Q IN Rc 1/8 Bracket (Option) MAX.DRAIN LEVEL Vacuum OUT AMJ3000, 4000 AMJ5000 Drain Discharge Drain guide (-J) Note) Series AMJ Dimensions B Note) 1394

AMJ4000, 5000 45 cm3 105 cm3 Bowl Capacity Mounting Operating Environment Maintenance Caution Caution Warning 1. Air piping should be thoroughly flushed before mounting. 2. When piping and fittings, etc. are being screwed together , be certain that cutting chips from the pipe threads, sealing material, and other debris do not get inside the piping. Further, when pipe tape is used, leave 1.5 to 2 thread ridges exposed at the end of the pipe. 3. The unit should be mounted vertically. 4. When piping is being installed, connect IN for work side and OUT for ejector or vacuum pump. 5. When drainage is discharged automatically, install 2 port solenoid valve and activate it in such an operation cycle like the drainage should be discharged by the time it reaches the upper limit. But when discharging it, return the case interior to atmospheric pressure before proceeding. Caution on Design Caution 1. When using with repeating positive pressure and negative pressure: Use at 0.1 MPa or less of positive pressure when the repeating tact is fast. The vessel may be hotter depending on the pressure and repeating tact conditions. Since the case material is polycarbonate, avoid using chemicals such as thinner, carbon tetrachloride, chloroform, aniline, cyclohexan, trichloroethylene, sulfric acid, lactic acid or water-miscible cutting fluid (alkaline), etc. Operation of the product in an atmosphere containing any of these chemicals should also be avoided. A neutral detergent may be used for cleaning the bowl. 2. Avoid use exposed to direct sunlight. 1. The element should be replaced after 2 years of use, or before the pressure drops to 0.02 MPa (0.2 kgf/cm 2). The spacer and O-ring should also be replaced at the same time that the element is replaced. Sometimes when the bowl is removed for a purpose other than replacing the element, the spacer may stick to the bowl and come off. In this case however, it may be returned to its installed position and used again. 2. Drainage should be discharged by the time it reaches the upper limit. Furthermore, when drainage is to be discharged or the element replaced, first confirm that all equipment, etc is stopped, and return the interior of the bowl to atmospheric pressure before proceeding. Series AMJ Specific Product Precautions Be sure to read before handling. Refer to front matter 35 for Safety Instructions and pages 899 to 901 for Vacuum Equipment Precautions. To ejector 1395 SP ZCUK AMJ AMV ZH -X185 Related Equipment AMJ A